26 Jul 2022, 6:00 pmClosed
GE South Delhi Cantt 10
Garrison Engineer South Delhi Cantt 110010
Repair/Replacement of DBs, submain wiring, earthing, building security lights and misc works alongwith connected fitting and fixture at OTM and Md Accn at Anuj Vihar, Vikram Vihar, Shankar Vihar, Bana Singh, Yogender Vihar, 180 Mahipalpur, 35 Inf
2022_MES_532265_1
GE/DS-33/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹84,000
Yes
26 Aug 2022
20 Jun 2022
28 Jul 2022
20 Jun 2022
26 Jul 2022
4 Jul 2022
Amount
S&F in replacement of VTPN distribution board 8 way double door, vertical type for fixing MCCB up to 250 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections and connecting complete all as specified and directed by Engr-in-Charge.
S&F in replacement VTPN DB 4 way double door type for fixing MCCB upto 200 Amps as incomer and MCB as out goinging with metal door and IP 43 protetions & connecting complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-2 Way, 240V without busbar as per site requirement all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-4 Way, 240V without busbar complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-8 Way, 240V with 200 Amp rated busbar complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-12 Way, 240V with 200 Amp rated busbar complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-16 Way, 240V with 200 Amp rated busbar complete all as specified and directed by Engr-in-Charge.
S&F in replacement single pole and neutral metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 16 Amps as per site requirement of existing type for geyser complete all as specified and directed by Engr-in-Charge.
S&F in replacement single pole and neutral metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SPN upto 32 Amps as per site requirement of existing type for ACs complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 160 Amps 3 pole 415 volts fixed type with breaking capacity 25 KA 415 volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 125 Amps 3 pole 415 volts fixed type with breaking capacity 16 KA 415 volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB TPN/ 4 Pole 63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB TPN/ 4 Pole 100 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB 3 Pole 63Amps 240 volts, 'C' Series as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SPN 63 Amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SPN 40 Amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SPN 32Amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCB SP 6 to 32 Amps 240 Volts, 10kA, `C' curve complete all as specified and directed by Engr-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, floors etc. complete all as specified and directed by Engr-in-Charge.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surface of walls including necessary touch up with thw adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engr-in-Charge. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per item No 20 above but One 3 pin socket outlet, 5/6 Amps, independent, with cables 1.5 sq. mm size with through existing concealed PVC/MS conduit.
All as per item No 20 but here-in-before 5 Amp socket outlet on same board.
All as Item No 20 but here-in-before for one socket outlet 5/15 Amps on Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit.
All as Item No 20 but here-in-before for one socket outlet 5/15 Amps on Independent board with cables 4 sqmm size for phase and neutral and 4 Sqmm for earthing with through existing concealed PVC/MS conduit.
All as Item No 20 but here-in-before for one One light controlled by 2-way switches using cable of 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing with through existing concealed PVC/MS conduit.
S&F switch piano flush type 5/6 Amps SP one way complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type 5/6 Amps SP two way complete all as specified and directed by Engr-in-Charge.
S&F bell push, flush type 5/6 Amps complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engr-in-Charge.
S&F switch piano type 15/16 Amps SP one way complete all as specified and directed by Engr-in-Charge.
S&F universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and directed by Engr-in-Charge.
S&F 0-4 step type electronic regulators for ceiling fan 1200/1400mm3 sweep, 240V complete all as specified and directed by Engr-in-Charge.
S&F in replacement ,Decorative wall light mounting suitable for LED Lamp upto 15 Watt complete with all connections complete all as specified and directed by Engr-in-Charge.
S&F Electric bell ding dong any type with fliexble wire complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Engr-in-charge.
S&F wall mounted LED Integrated batten T5 20Watt -4ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 36/40Watt FTL fitting any type, complete all as specified and directed by Engr-in-Charge.
S&F wall mounted LED Integrated batten T5 10Watt -2ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 18/14 watt FTL fitting any type, complete all as specified and directed by Engr-in-Charge.
S&F Surface mounting Round/ Square shaped LED downlighter 6 Watt any type including new fliexble wire as required on site in replacement of old unsv existing ceiling light fitting complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including required LED bulb and all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and directed by Engr-in-Charge.
S&F LED Building security light fitting 30 Watts including taking down of old unsv existing building security light fitting any type, from existing bracket with and including replacement of unsv bolts, nuts and washers etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement GI pipe's bracket suitable for fixing of bldg security LED light fitting of 35 Watts including grouting and fixing the same on wall for installation of light fitting with necessary clamps, nut, bolts & washer and applying painting synthetic enameled paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket complete all as specified and directed by Engr-in-Charge. Note : GI pipe should be 40 mm bore dia with medium grade and the same to be moulded in 45 degree angle at the 1 Mtr height to fix the building security light fitting.
S&F Recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed by Engineer-in-Charge.
S&F LED Post top 25 Watt made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection round shape , PF> 0.90 completed with all accessories including MS Pipe 40mm dia and necessary connections with suitble size of copper cable complete all as specified and directed by Engr-in-Charge.
S&F in replacement Sheet metal enclosure of size 350 x 300 x 150 mm suitable for mounting pre paid electronic meter with device fabricated from CRCA sheet with anti corrosive dust and vermin proof. Note:- The meter cover shall have a transparent window . The window shall be of transparent, high grade UV stabilized engineering plastic for easy reading of all the displayed values/parameters and observation of operation indicator. The window shall preferably be an integral part of meter cover complete all as specified and directed by Engr-in-Charge.
Taking down and re fixing electronic/ pre paid meter in meter box with consultation with pre paid meter authorities including necessary connections of incoming and out going cables for light and power complete all as specified and directed by Engr-in-Charge.
S&F in replacement earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI wire 4 mm as earthing lead by means of nut, bolts and check nuts and washers, GI light grade protection pipe 15 mm dia upto 7.5 M, GI watering pipe 20 mm dia medium grade, RCC cover with funnel, excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 5 of SSR Part I, including earth test point upto panel board, all as specified or indicated including testing on completion complete all as specified and directed by Engr-in-Charge.
M&L for painting of VTPN DB/ Panel box including meter box of complete block in situ with one coat of synthetic enamel piaint of existing colour by spraying after cleaning, scrapping all dust complete and writing of Qtr No on each Meter Box complete all as specified and directed by Engr-in-Charge.
S&F in rerplacement submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 10 Sqmm in 2 runs and 10Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and directed by Engr-in-Charge. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
All as per item No.48 but cable size 6 Sqmm in 2 runs and 6 Sqmm one run for earth.
All as per item No.48 but cable size 4 Sqmm in 2 runs and 4 Sqmm one run for earth.
All as per item No.48 but cable size 2.5 Sqmm in 2 runs and 2 Sqmm one run for earth.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
verma enterprises
M/s Adhikari construction co.
GAUTAM ELECTRIC WORKS
Surjit and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .