Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
30 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE 866 EWS
GE 866 EWS CARNICOBAR PIN-913866 C/O 99APO
SPECIAL REPAIR/ REPLACEMENT OF BER COOLING APPLIANCES AT AF STN CARNICOBAR
2026_MES_793022_1
8878/E8
Open Tender
Civil Works
Item Rate
270 days
GE 866 EWS
as per tender documents
9 documents required · 9 mandatory
₹500
GE 866 EWS
₹96,000
Yes
9 Oct 2026
9 Oct 2026
6 Nov 2026
9 Oct 2026
30 Oct 2026
23 Oct 2026
9 Oct 2026 - 16 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old ACs split type of 1.5/2 TR capacity from site and transporting to AGE E/M store yard for depositing.
Note: (i) Rate including disconnecting all electrical cbles, makng shutdown and all kind of peventive measures deemed to be incuded in quoted rate.
(ii) Suitable veh for conveyance of taken down assets from the site upto AGE E/M salvage store shall deemed to be included in quoted rate.
(iii) Skilled manpower for dismountig and taking down shall be deployed by the contractor at site. | 35 | Each | - | - |
| 2 | Supply, installation, testing and commissioning of Split type Air Conditioner of Capacity 1.5 TR, 5 Star rating, Inverter type,Indoor unit with copper coiling coil and outdoor unit with copper tube condenser coil complete with cordless remote control, filled with the latest environment friendly refrigerant R-32 fitted with highly energy efficient rotary compressor of copper wound, including PVC FRLS grade multistranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, Copper connection pipes with insulation, GI brackets/stand for outdoor unit, clamps, nuts, bolts, washers, drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with PCC, white cement and painting work to match with the existing surface of wall complete all as specified and directed.
Make- Bluestar Model No-IC518DNU or equivalent in Voltas/ LG/ Daiken/ Hitachi.
Notes: -
(a) Installation work to be carried out by (OEM or Authorised dealer).
(b) Copper connection pipes with insulation exceeding 3 Mtrs and PVC drain pipes shall be measured and paid separately.
(c) Compressor Warranty 5 years. | 17 | Each | - | - |
| 3 | Supply, installation, testing and commissioning of Split type Air Conditioner of Capacity 2 TR, 5 Star rating, Inverter type,Indoor unit with copper coiling coil and outdoor unit with copper tube condenser coil complete with cordless remote control, filled with the latest environment friendly refrigerant R-32 fitted with highly energy efficient rotary compressor of copper wound, including PVC FRLS grade multistranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, Copper connection pipes with insulation, GI brackets/stand for outdoor unit, clamps, nuts, bolts, washers, drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with PCC, white cement and painting work to match with the existing surface of wall complete all as specified and directed.
Make- Bluestar Model No-IC518DNU or equivalent in Voltas/ LG/ Daiken/ Hitachi.
Notes: -
(a) Installation work to be carried out by (OEM or Authorised dealer).
(b) Copper connection pipes with insulation exceeding 3 Mtrs and PVC drain pipes shall be measured and paid separately.
(c) Compressor Warranty 5 years. | 18 | Each | - | - |
| 4 | Supply,testing and commissioning in replacement of water cooler electrically driven, stainless steel body, IEE raiting 3.5 min single phase with inbuilt purifier HIMA 7 NHC , dispencing capacity 125 Ltrs/hr and storage tank capacity 40 Ltrs normal, 40 Ltrs Cold, single phase 230 V AC power supply with all connecting accessories complete all as specified and as directed.
Note: The rate quoted by the contractor shall be deemed to include the disconnection, dismantling and removal of the existing old/unserviceable water cooler of any capacity from the site of installation, including handling, loading, transportation and unloading at the AGE E/M Store Yard, and depositing the same at the designated location as directed by the Engineer-in-Charge, complete in all respects.
Make:Voltas/Blue star/Godrej/Usha | 1 | Each | - | - |
| 5 | Supply, installation, commissioning in replacement of Deep Freezer, BEE 5 Star rated, electrically driven single phase 240 volt, 50 Hz. capacity of 320 ltr with complete fitting & fixture complete all as specified and directed by Engineer in charge
Make: Whirlpool/Samsung/LG
Note:-The rate quoted by the contractor shall be deemed to include the disconnection, dismantling and removal of the existing old/unserviceable deep freezer of any capacity from the site of installation, including handling, loading, transportation and unloading at the AGE E/M Store Yard, and depositing the same at the designated location as directed by the Engineer-in-Charge, complete in all respects. | 3 | Each | - | - |
| 6 | Supply, installation, commissioning in replacement of Deep Freezer, BEE 5 Star rated, electrically driven single phase 240 volt, 50 Hz. capacity of 405/425 ltr with complete fitting & fixture complete all as specified and directed by Engineer in charge
Make: Whirlpool/Samsung/LG
Note:-The rate quoted by the contractor shall be deemed to include the disconnection, dismantling and removal of the existing old/unserviceable deep freezer of any capacity from the site of installation, including handling, loading, transportation and unloading at the AGE E/M Store Yard, and depositing the same at the designated location as directed by the Engineer-in-Charge, complete in all respects. | 1 | Each | - | - |
| 7 | Supply, installation, commissioning in replacement of Refrigerator, BEE 5 Star rated, electrically driven single phase 240 volt, 50 Hz. capacity of 185 ltr with complete fitting & fixture. all as specified and directed by Engineer in charge
Make: Whirlpool/Samsung/LG
Note:-The rate quoted by the contractor shall be deemed to include the disconnection, dismantling and removal of the existing old/unserviceable Refrigerator of any capacity from the site of installation, including handling, loading, transportation and unloading at the AGE E/M Store Yard, and depositing the same at the designated location as directed by the Engineer-in-Charge, complete in all respects. | 3 | Each | - | - |
| 8 | Supply, installation, commissioning in replacement of Refrigerator, BEE 5 Star rated, electrically driven single phase 240 volt, 50 Hz. capacity of 315 ltr with complete fitting & fixture. all as specified and directed by Engineer in charge
Make: Whirlpool/Samsung/LG
Note:-The rate quoted by the contractor shall be deemed to include the disconnection, dismantling and removal of the existing old/unserviceable Refrigerator of any capacity from the site of installation, including handling, loading, transportation and unloading at the AGE E/M Store Yard, and depositing the same at the designated location as directed by the Engineer-in-Charge, complete in all respects. | 3 | Each | - | - |
| 9 | Supply, installation, commissioning in replacement of Refrigerator, BEE 5 Star rated, electrically driven single phase 240 volt, 50 Hz. capacity of 210 ltr with complete fitting & fixture. all as specified and directed by Engineer in charge
Make: Whirlpool/Samsung/LG
Note:-The rate quoted by the contractor shall be deemed to include the disconnection, dismantling and removal of the existing old/unserviceable Refrigerator of any capacity from the site of installation, including handling, loading, transportation and unloading at the AGE E/M Store Yard, and depositing the same at the designated location as directed by the Engineer-in-Charge, complete in all respects. | 1 | Each | - | - |
| 10 | Supply and fixing in replacement of portable floor-mounted De-Humidifier, having dehumidification capacity not less than 30 litres/day, power consumption 1700 W, with 8 litres capacity water collection tank, suitable for clothes drying/laundry drying application, provided with A++ rated filter screen, automatic humidity control, digital display, automatic cut-off on full tank, auto-defrost and condensate overflow protection, suitable for operation on 230 V, single phase, 50 Hz AC supply, complete with all standard accessories, controls, connections, installation, testing and commissioning, all as specified and as directed | 2 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.46 MB
8878Tender.pdf
Tender Documents • 0.86 MB
BOQ_889291.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .