| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹23.6 L+₹33,296.60 (1.43%)Rejected-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹25.8 L+₹2.5 L (10.8%)Rejected-Finance 158 PADRI BAZAR TINKONIYA NO 1 PARVATIPURAM GORAKHPUR GORAKHPUR UTTAR PRADESH 273014 | GORAKHPUR | UTTAR PRADESH | 273014 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹27.6 L+₹4.3 L (18.7%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹29.7 L+₹6.5 L (27.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid |
Tender Value
₹40.9 L
EMD Value
₹81,880
Closing Date
17 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER EAST JALANDHAR CANTT
GARRISON ENGINEER EAST JALANDHAR CANTT
AUGMENTATION OF EXTERNAL ELECTRIC SUPPLY AT 350 INF BDE AND CERTAIN OTHER SANCTIONED WORK UNDER GE (EAST) JALANDHAR CANTT
2020_MES_354454_1
GE/JULL/ET-30/2020-21
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER EAST JALANDHAR CANTT
₹81,880
Yes
16 Oct 2020
17 Jul 2020
19 Sept 2020
17 Jul 2020
17 Sept 2020
1 Aug 2020
60 days
Amount
Material and labour for point wiring with 1.5 sqmm (nominal area), 1100 volt grade PVC insulated FRLS type multi stranded copper conductor cable drawn in and including concealed rigid PVC conduit ISI marked with accessories including cutting chases for laying of conduit/ fixing of boxes in walls/ floors etc including making good to disturbed surfaces as per adjoining specification and terminated in concealed terminal boxes including MS concealed terminal boxes with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with washers and earth continuity PVC insulated FRLS type cable with stranded copper conductor of size 1.5 sqmm (nominal area) green colour as earth wire connected with earth dolly for one fan point controlled one switch complete all as specified and directed and as directed.
All as per item No. 1.00 but 3 pin 15 Amp socket outlet with 4 sqmm PVC insulated FRLS copper cable and 2.5 sqmm PVC insulated FRLS copper cable for continuous earth continuity conductor all as specified and directed
Supply and fixing switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified and directed.
Supply and fixing switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified and directed.
Supply and fixing ceiling rose surface type bakelite 65 x 50mm three terminal complete all as specified and directed.
Supply and fixing metallic body exhaust fan, 300mm sweep, 900 RPM, single phase, 230 Volt, heavy duty with louvered shutter including provision of three core copper conductor cable of required length of size 23/ 0.0076 from ceiling rose/ connector to fan terminal, fixing the fan on wall with suitable size of nuts, bolts & washers, making the hole in wall including necessary civil/ plastering work to match the disturbed surface complete all as specified and directed.
Supply and fixing exhaust fan, metallic body 225mm sweep, 1400 RPM, single phase, 230 Volt, heavy duty with louvered shutter including provision of three core copper conductor cable of required length of size 23/ 0.0076 from ceiling rose/ connector to fan terminal, fixing the fan on wall with suitable size of nuts, bolts & washers, making the hole in wall including necessary civil/ plastering work to match the disturbed surface complete all as specified and directed.
Material and labour for cutting holes for exhaust fan of size 300mm dia sweep in brick walls built in cement mortar or cement lime mortar and stone walls built in cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required complete all as specified and directed.
Material and labour for cutting holes for exhaust fan of size 250mm dia sweep in brick walls built in cement mortar or cement lime mortar and stone walls built in cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required complete all as specified and directed.
Material and labour for sub main wiring with PVC insulated cable copper conductor FRLS two single core 2.5 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 2.5 Sqmm PVC insulated with green insulation complete all as specified and directed.
Material and labour for sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 2.5 Sqmm PVC insulated with green insulation complete all as specified and directed.
Material and labour for sub main wiring with PVC insulated cable copper conductor FRLS two single core 6 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified and directed.
Supply, installation and commissioning step down distribution transformer of capacity 200 KVA copper wound outdoor type 11000/ 433 volt 3 phase 4 wire 50 cycles, naturally oil cooled type suitable for outdoor installation, connected delta on HV side and star on LV side with neutral brought out LT side with solid earthing bush with brass nut, check nut system with off load tap changing switch on HT side to vary secondary voltage with in limit in steps of 2.5% each and with standard accessories like oil temperature with indicator for highest temperature gauge, silica gel, breather assembly, oil conservator tank with oil filling hole duly plugged, with bare HV and LV bushing, CI roller wheel, lifting lugs, explosion vent, air release plug, body earthing terminals, oil drain valve of gun metal with plug, oil filling valve with plug, name rating and diagram plate, oil level indicator and arching horn set and other required fittings/ accessories including first fill of oil upto required level all as per IS:2026 (with upto date amended) including connections complete all as specified and directed. Note :-(i) Pre-commissioning test shall be carried out by the SEI for which all arrangements shall be made by the contractor without any extra cost. (ii) Standard connected accessories/ fittings in addition to above as required shall be provided and cost is deemed to be included in the quoted rate. (iii) Contractor will submit specification from approved manufacturer comprising of the above specification to GE and take approval before placing order
Supplying, laying, jointing and testing LT underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade earthed system of size 300 sqmm 3½ core conforming to IS laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supplying, laying, jointing and testing LT underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade earthed system of size 185 sqmm 3½ core complete all as specified and directed.
Supplying, laying, jointing and testing LT underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade earthed system of size 120 sqmm 3½ core complete all as specified and directed.
Supplying, laying, jointing and testing LT underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade earthed system of size 35 sqmm 3½ core complete all as specified and directed.
Supplying, laying, jointing and testing LT underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts grade earthed system of size 95 sqmm 3 core complete all as specified and directed.
Supply and fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 10 Sqmm flat twin core cable in service connection all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in foundation of stay/ coping of poles including necessary form work and fair finish to exposed surface without using extra cement complete all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation of electric pole, etc, including necessary form work and fair finish to exposed surface without using extra cement complete all as specified and directed.
Material and labour for manual boring hole under the road/ pavement/ hard standing with the help of trenchless technology and inserting GI pipe of suitable dia at a depth not less than one metre below ground level complete all as specified and directed
Excavation in trenches in soft/ loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erecting poles, stay assembly etc. and getting out complete all as specified and directed.
All as per item No. 23.00 here-in-before but depth exc. 1.5 but n.exc 3.0m
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25 cm thick each layer complete all as specified and directed.
Removal of surplus soil to a distance n. exc. 50 mtr and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning with 8cm thick layer of sand before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length complete all as specified and directed
Supply & laying in replacement un-reinforced pre-cast concrete cable cover, Class HV, type-I, flat, size 300mm x 180mm x 40mm laid flat in trenches over the cable length, adjacent/ abutting each other complete all as specified and directed
Supply and fixing 80mm bore galvanised pipe light grade fixed along poles/ to walls/ laid under floor complete with and including fittings and clamps as required complete all as specified and directed.
All as per item No. 30.00 her-in-before but 50mm bore pipe
All as per item No. 30.00 her-in-before but 40mm bore pipe
All as per item No. 30.00 her-in-before but 32mm bore pipe
All as per item No. 30.00 her-in-before but 25mm bore pipe
Supplying, erecting and fixing pre-stressed concrete pole 11 metre long, 152 x 152mm at top and 152 x 260mm at bottom, class 9, complete all as specified and directed including painting of poles with two coats of synthetic enamel paint over a coat of primer, black & white strips upto 1.5mtr height from top of PCC coping and numbering of poles fixed in repairs of old broken pole complete all as specified and directed. (PCC and earth work shall be measured & paid for separately)
Supplying, erecting and fixing pre-stressed concrete pole 9.0 metre long having x-sectional area 102 x 172mm at top and 102 x 279mm at bottom, class 10, complete all as specified and directed including painting of poles with two coats of synthetic enamel paint over a coat of primer, black & white strips upto 1.5mtr height from top of PCC coping and numbering of poles fixed in repairs of old broken pole complete all as specified and directed. (PCC and earth work shall be measured & paid for separately)
Supply and fixing in replacement pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed
Supply and fixing in replacement lightening arrester expulsion type complete all fittings, transmission class, discharge capacity 65 Kilo amp rupturing capacity 65 Kilo Amps porcelain conforming to IS 3070 Pt-I suitable for 11 KV, HT over head line complete including nuts, bolts, clamps, bracket etc and connecting with GI earth wire, discharge capacity 65 Kilo Amp complete all as specified and directed.
Supply and fixing switch air break gang operated switch outdoor type HT 11 KV triple poles of rating 200 Amps with fixed contacts of phosphorus bronze and moving contacts of copper with mechanically operating system from ground level vertical mounted complete with HT insulators on mild steel frame and operating rod made out of 25mm GI pipe medium grade worked from ground level with handle and locking arrangements with 12 insulators of 11 KV with drop out fuses including two coats of aluminium paint on steel structure complete including submission of test certificate from manufacturer all as specified and directed. Note: Clamps/ cross arms shall be measured and paid for separately.
Supply and fixing in replacement aluminium conductor steel reinforced for overhead lines on poles including aluminium binding wire 14 SWG, jumpers, line tapes etc including taking out unserviceable conductor complete all as specified and directed. Note: For payment purpose weight of ACSR conductor only shall be considered.
Supply, fixing and testing after jointing cable end jointing kit for 11 KV grade cable for outdoor type termination cold shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminium cable for size 95 sqmm 3 core complete all as specified and directed.
Supply and fixing cross arms, bracings, brazing stiffness, supports clamps and back plated fabricated from structural steel section including nuts, bolts and washers, welding, bending, cold or hot drilling holes of any shape and size as directed including two coat of aluminium paint (under and finishing coat ) over a coat of red oxide or primer complete
Supply and fixing in repairs shackle type insulator size 100mm height, 115mm dia with bolts dia 14mm and strap section 31x5 mm for 1100 volts working pressure porcelain vitreous white, brown or green insulator including galvanised mild steel straps, two galvanised iron washer, insulator bolts and one galvanised iron nuts all as specified.
Supply and fixing in replacement bracket made out of 40mm dia medium grade GI tubing 2 metre long and bent to shape at 1200 angle with stiffener on bent portion made out of MS sheet 6mm fixed with clamps, nuts, bolts, washer including painting complete with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Note : Clamps, nut, bolts and washers will be measured and paid separately.
Taking down cross arms, channels, angle iron, clamps, nuts, bolts, stay wire, stay assembly, GI wire etc. complete all as specified and directed.
Taking down old LT cable of size 70 to 120 sqmm 3½ core complete all as specified and directed
Taking down old LT service wire off size complete all as specified and directed.
Taking down and refixing LED street light luminaire from old steel tubular/ PCC pole and refixing on new pole complete all as specified and directed.
Supply & fixing in replacement earthing complete for transformer/ VCB panels/ LT panels with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of the plate at a depth not less than 1.50 metre below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 50mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 Nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified and directed. Note: If result is not achieved satisfactory, contractor will have to do re-earthing at his own cost. Nothing shall be paid extra on this account
Supply, installing, testing and commissioning in-replacement feeder pillar, outdoor cubicle type weather and vermin proof totally enclosed made out of 3mm thick CRCA sheet machine pressed of suitable size, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement including inner independent enclosures for all switches/ MCCBs/ metering equipments with hinged (bottle type) shutters, bottom gland plate with sufficient numbers of circular cable entry holes with cable glands of suitable size of cable & with suitable cable glands as per number of outgoings, prewired complete duly powder coated with 7 tank process with base frame made of angle iron 50 mm x 50 mm x 6 mm, legs 100 cm long having openable apron on all three sides of panel 30 cm wide and grouted 45 cm in PCC (1:3:6) type C-1 including brick masonary platform 45cm above ground level all as specified and directedby Engr-in.charge, comprising with following complete:- (a) Bus bar suitable for 3 phase, 415 volts, 50 Hz, 4 wire system of rating 450 Amps made out copper strip of suitable size with coloured heat shrinkable sleaves in four colours (Red, yellow, blue and black) fixed on resin cast insulators including galvanised nuts, bolts and washers etc fitted with and including the following :-
(ii) INCOMING : - (a) MCCB 315/320 Amp, 415 V, 36 KA, 4 pole with thermal magnetic release, ICS=ICU=100% -01 No. (b) Panel meter of size 96x96 mm with LCD display , accuracy class 1.0, having parameters Voltage, Current, Frequency, Power factor, Power & Energy complete all as specified and directed, duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete. (c) Indicator with LED lamps for RYB , 3 Phase with MCBs set of three -01 set (iii) OUTGOING:- (a) MCCB 200 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release ICS=ICU=100% -01 No. (b) MCCB 160 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release, ICS=ICU=100% -01 No. (c) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release, ICS=ICU=100% -01 No. (d) MCB SPN 40 Amp, C series 230 Volt-02 Nos (e) Indicator with LED lamps for RYB , 3 Phase with MCBs set of three -03 sets
Supply, installed, connecting, commissioning and testing of water cooler Electric driven (single phase) 230 volts, 50 c/s having approx storage Capacity of 40 litres and nominal cooling capacity of 80 Litres per hour, Star rated with environmental friendly non CFC gas, full stainless steel with all accessories complete all as specified and directed
Supply, installed, connecting, commissioning and testing of water cooler Electric driven (single phase) 230 volts, 50 c/s having approx storage Capacity of 150 litres and nominal cooling capacity of 180 Litres per hour, Star rated with environmental friendly non CFC gas, full stainless steel with all accessories complete all as specified and directed
Supply and fixing socket outlet 15 Amp 6 pin flush type complete all as specified and directed.
Supply and fixing MCB SP 25 Amps, B-Curve, 240V, 10 KA complete all as specified and directed.
Supply, installation, commissioning and testing of voltage stabilizer copper wound for automatic operation, wall mounted type having connecting lead, 3 core PVC insulated stranded copper conductor and connection plate for input connection, single phase naturally air cooled indoor type and designed for input variation between 150 Volts to 290 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% having voltmeter, indicator for normal running and low and high cut out indicators of capacity 4 KVA complete all as specified and directed
Supply installation, testing and commissioning of solar water heating system (heat exchanger type0 of capacity 100 LPD consisting of flat plate collector ISI marked confirming to IS-13933 Part-I complete with copper riser tubes copper heater tube copper heat absorber complete with hot water storage tank of capacity 200 ltr which shall be fabricated from stainless steel in cylindrical shape and outer cover fabricated from aluminium sheet with glass wool media as insulation with necessary ceramic or enameled coated electric back up heating elements im 2 KW 02 Nos as per manufacturer recommendation with heat exchanger in hot water tank with necessary make up tank of stainless steel, 01 No float valve 20mm dia to maintain water in collector and heat exchanger, necessary piping between collector and hot water tank complete all as specified and directed
Supply and fixing 50mm gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed
Supply and fixing 25mm gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed
Supply and fixing hot water pipe duly insulated with glass wool and aluminium cladding 25mm bore complete all as specified and directed
Supply and fixing bib taps, cast copper alloy, with crutch or butterfly handles, fancy type screwed down, screwed for 15mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
Supply and fixing sheet metal enclosure for DBs when MCBs to be used, SPN 4 ways 240 V, with 200 Amps rated bus bar, double door, epoxy coated inside and outside with neutral and earth connection bar prewired complete all as specified and directed.
Supply and fixing MCB SPN 40 Amps , 240V 10 KA, B-Curve complete all as specified and directed.
Supply and fixing rotational moulded polyethylene water storage tanks, 500 liter capacity (cylindrical vertical with closed top), ISI marked, hoisted and fixed in position all as specified in SSR Part I, fixed in repairs complete all as specified and directed.
Material and labour for in replacement for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15mm dia GI pipe 'light grade', watering pipe 20mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed.
Material and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
GULSHAN SINGH GHAI AND SON
CHOUDHARY AND SONS
UNITED ENGINEERING CORPORATION
Shree Balaji Construction
AK Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .