| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹4.2 L+₹3,915 (0.94%)Rejected-Finance | L2 | Rejected-Finance Being NOT Lowest | |
| 3 | L3₹4.4 L+₹28,570.50 (6.89%)Rejected-Finance | L3 | Rejected-Finance Being NOT Lowest | |
| 4 | L4₹4.8 L+₹61,726 (14.9%)Rejected-Finance | L4 | Rejected-Finance Being NOT Lowest | |
| 5 | L5₹4.9 L+₹70,970 (17.1%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L5 | Rejected-Finance Being NOT Lowest |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
9 Mar 2020, 6:00 pmClosed
GE BHOPAL
GE BHOPAL
REPAIR/MAINT OF INTERNAL ELECTRIFICATION AND FIXTURES TO CERTAIN OTM ACCN AT BAIRAGARH UNDER GE BHOPAL.
2020_MES_323868_1
8624/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
BHOPAL
Class E Category b i
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹14,000
Yes
16 Mar 2020
11 Feb 2020
11 Mar 2020
11 Feb 2020
9 Mar 2020
25 Feb 2020
Amount
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
Taking down unserviceable sub main wiring including service connections, of any size and any description including conduit pipe complete all as specified and directed.
Taking down old unserviceable MCB DB of any size and capacity including wooden boards complete all as specified and directed.
M&L for point wiring for one light / fan / bell point/ one 3 pin 5 Amp socket outlet on independent board with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells] Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Rate includes chase cutting for concealed wiring.
All as per BOQ item No.4.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No.4.00 above, but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per BOQ item No.4.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on or 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per BOQ item No.4.00 above, but wiring with 4.0 Sq mm copper cable for 5/15 amp switch socket combination or 3 pin socket out let 15 amp on independent board and provision of 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring for one light / fan / bell point/one 3 pin 5 Amp socket outlet on independent board with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in existing concealed/surface conduit including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs and 3mm thick laminated hylum sheet cover including taking old point wiring (any type without conduit) complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.8.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No.8.00 above, but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per BOQ item No.8.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 2.5 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 2.5 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
S&F Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket oulet, multipurpose, 2 in 1, 3 pin, 5 & 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch piano, one way, single pole, 16/20 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F ceiling fan regulator electronic steped type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings with & including LED lamp white 9 watt retrofit, 230 volts complete all as specified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE] & LAMP : BAJAJ/PHILIPS/SYSKA]
S&F Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR / LEADER/ LEGRAND /HAVELLS as approved by GE]
S&F sheet metal enclosure for MCB DB TPNL (Horizontal type), 415 volts, 200 Amp rated bus bar having IP-43 protection and double metal door, RAL 9003 powder coated, with MCB as incomer and MCB SP/TP in outgoing complete all as specified and as directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 12 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 8 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
S&F MCB SPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F MCB TPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 40 to 63 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F single pole and neutral enclosure with two pin and earth, plug and socket, single phase, 240 V with & including 1 No single pole MCB, capacity 20 amps, `C` charactristic, breaking cap 10 KA and industial plug top complete all as specified and directed. [MAKE:-Legrand (Cat no. 607841)/ Siemens/ Schinder/L&T] as approved by GE]
S&F in replacement LED 20 W/21Watt tube light fitting (T8 type) with and including LED retrofit tube 20/21 W, 240V, PV > 0.90, colour Temp 6500 K, system luminious efficancy > 100Lm/W complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. [Make :- Crompton (Batten Cat no. DMLN 1LT 8-16, Integrated LED tube cat no.LT8-20-865-2) or equivalent in Wipro/ Philips/ Bajaj/SYSKA/HAVELLS as approved by GE.]
S&F in replacement LED 10/9 Watt tube light fitting, surface mounting fitting for mirror light with slik and light weight batton, 240 Volt, with PF >0.95, efficacy >95 , colour temp 6500K complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. [MAKE: HAVELLS (Cat no. LHEXBQP7PN1W009) or equivalent in Bajaj/Crompton/WIPRO/Philips/SYSKA as approved by GE.]
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
S&F in replacement single phase direct connection type KWH meter, temper proof, plastic body with optical port with box LCD display with polycarbonate temper proof cover, 230/240V, 10-60 Amp, accuracy class I, 50 Hz, conforming to IS-13779, IP 54, (with parameters to show date, time, current reading, KW, PF) fixed in existing position on and including wooden board first quality of size 250 mm x 300 mm and making elctric connections complete all as directed specifed and directed. [Make : L&T (Cat Part No.WMDDHBOX) or eqivelent in Legrand/ Havells/HPL/GE/SECURE METERS as approved by GE] Note : Old meter shall be deposited in AGE E/M store yard, Bairagrh.
S&F in repairs LED bulk head luminare weather proof of 10 watt and making connectioms with copper flexible three core 23/0.0076 complete all as specified and as directed. [Make: Bajaj ( Cat No.BIBWP10W LED- 112334) or equivalent in Crompton/Philips/ Wipro/ Havells as approved by GE]
S&F GI tubing light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed of following sizes:-
15 mm bore
Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 16 Sqmm x 4 core nominal cross section in service connections in culding taking down old service connections complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/ KEI/V-MARC as approved by GE]
Excavating in trenches, nott exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed
M&L for Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubings or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed.
Taking down & refixing connecting electric meters SP upto 40 Amps in existing or new position including S&F wooden board first quality, closed recessed type of size not less than 250 mm x 300 mm and 50mm deep covered with additional mica top and making elctric connections complete all as directed specifed and directed.
Taking down old ceiling fan/Exhaust fans/Wall mounting fan of any cap/sweep after disconnecting the electric supply from any site, carriying out over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing and re-assembling, and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin and connecting with flexible three core copper wire 0.5 sqmm complete all as specified and directed.
Deduct schedule of credit (calculation will be done off line) Rs.24,588.00
MODI CORPORATION
M S MEWALAL UPADHYAY
RAJPATI CONSTRUCTION
PRAGATI ELECTRICALS AND ELECTRONICS
ROYAL CONSTRUCTION
M/S Shanti Enterprises
M/s VIKAS TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .