Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.5 L+₹3.3 L (7.52%)Rejected-Finance | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹49.9 L+₹6.7 L (15.4%)Rejected-Finance H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L3 | Rejected-Finance Being not lowest tenderer | |
| 4 | Rejected-Technical C 223 MIANWALI COLONY GURUGRAM 122 001 HARYANA | GURUGRAM | GURUGRAM | HARYANA | 122001 | - | Rejected-Technical No WLR of HQ CE WC for QE Jun 2024 at Srl No 86 |
Tender Value
₹70 L
EMD Value
₹1.3 L
Closing Date
13 Sept 2024, 6:00 pmClosed
CWE AF TUGHLAKABAD
HQ CWE AF TUGHLAKABAD AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
REPAIR/REPLACEMENT OF FLOOR AND WALL TILES ,JOINERY, ROOF TREATMENT PLASTERING ,GRIT WASH ,SANITARY FITTING AND OTHER B/R WORKS INCULDING POINT WIRING ALONGWITH FITTING AND FIXTURE IN CERTAIN SMQ AND DSC QTR AT AF STN GURGAON UNDER GE(AF) GURGAON NO1
2024_MES_666058_1
CWE/TKD/GUR/TOKEN-23 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Gurgaon No.1
As per NIT conditions
7 documents required · 7 mandatory
₹0
₹1.3 L
Yes
11 Dec 2024
15 Jul 2024
16 Sept 2024
15 Jul 2024
13 Sept 2024
5 Aug 2024
Amount
Schedule ‘A’ Part-I (B/R)
S&F in repair 60 cm long PVC connection with two nos PTMT nut and rubber washers suitable for 15mm bore GI Pipe of existing one complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 10ltr capacity PVC valveless syphonic action type flushing systern low level white with inlet ball valve ,float & handle including brackets complete all as specified and as directed by Engineer-in-Charge.
S&F in repair PTMT waste coupling 32mm bore of discharge (Half or full threaded) Min weight 45 gms, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair of PTMT waste pipe 32 mm bore 80 cm long complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Rotational moulded Polyethylene (HDPE) Water Storage Tank 500 LITRE Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I, including tank nipple, union and Lowering of unserviceable Water Storage Tank with Float Valve of any description complete all as specified and directed by Engineer in charge.
Dismantling of cast iron , concrete, asbestos, PVC pipes of 100mm dia and discription from trenches or with walls etc complete all as specified.
S&F for 100 mm dia cast iron spun soil, waste and vent pipes , in any length with or without ears, with cement joints, laid in trenches or in floors and fixed to walls as complete all as specified and directed.
S&F for 100 mm bore Bends (any radius) with oval access door diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
M&L stack clamps for 100 bore pipe as in repairs out of 50mm by 5mm flat iron and 16mm dia round iron stays incl bolt and nuts and securing end of stays to wall or roofs complete all as specified and as directed.
S&F Cast iron cowls for 100mm dia cast iron pipe complete all as specified and as directed.
S&F PVC pipes single socketed in any length with rubber ring joints fixed to wall ( 110mm bore) including flat iron claimp for proper fixing complete all as specified and as directed by Engineer-in-Charge.
S&F PVC bends 110mm dia complete all as specified by Engineer-in -Charge
S&F for steel water tubing 15mm bore, galvanised, medium grade with and including provision of all fittings of ISI marked and connected complete incl taking down old GI pipe all as specified and as directed by Engineer-in-Charge.
S&F for steel water tubing 20mm bore, galvanised, medium grade with and including provision of all fittings of ISI marked and connected complete incl taking down old GI pipe all as specified and as directed by Engineer-in-Charge.
S&F in repair 15mm dia concealed stop cock chromium plated with long screwed down high pressure with cruteh or butterfly handle screwed both end for iron pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 2 in 1 bib taps 15mm bore long body cast copper alloy fancy type chormium plated butter fly handle screwed down including complete all as specified and as directed by Engineer-in-Charge.
S&F in repair bib taps 15mm bore long body cast copper alloy fancy type chormium plated butter fly handle screwed down including complete all as specified and as directed by Engineer-in-Charge.
S&F in repair angle/ stop valves 15mm bore (for iron pipe) fancy type chromium plated screwed down high pressure with butterfly handle screwed both ends complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 125 mm dia fancy type shower roses brass chromium plated with C P arms of length upto 60 cm for 15mm bore GI pipe. complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 15 mm brass CP mixer for mixing hot and cold water for sink mixer with wall flange extended operating lever, swinging spout complete all accessories as required complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 15 mm brass CP mixer for mixing hot and cold water for wash basin mixer with wall flange extended operating lever, swinging spout complete all accessories as required complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 15 mm brass CP mixer for mixing hot and cold water for non telephonice wall mixer with wall flange extended operating lever, swinging spout complete all accessories as required complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Sink with drainage board made of stainless steel 1 mm thick kitchen or laboratories with plugs, washer and wastes pipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets ,sink coupling and connecting union to pipe overall size 915x 460x bowl size 410x330x160mm complete all as specified and as directed by Engineer-in-Charge.
S&F in repair wash down water closet (pedestal pattern) of any colour including fixing of bolts complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for vitreous china wash basin hand white flat backsize 600x480mm including cutting for and pinning in ends of brackets including fixing of 32 mm low dencity polylethyne pipes (LDPE)of pressure rating 6kg/cm2,cupling ,PVC connection with 15 mm dia PTMTcheknuts ,brackets all complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 300mm MS Helical door spring including roller & roller plate complete all as specified and as directed by Engineer-in-Charge.
S&F in repair anodised aluminium alloy tubular curtain rods fancy type with brackets ,stops, rollers etc all as specified and direced by Engr-in-Charge.
S&F in repair stainless steel floor grating with hole or without hole all as specified and directed by Engr-in-Charge.
Towel Ring 600mm long of stainless steel fixed with and including Chromium plated brass screws and wooden/plastic cleats all as specified and directed by Engr-in-Charge
Towel rail of size is 600mm long of stainless steel fixed with and including Chromium plated brass screws and wooden/plastic cleats all as specified and directed by Engr-in-Charge
S&F in replacement plate rack stainless steel made out of sheet not less than 1 mm thick, size 30 inch 36 inches 10 inche with bracket all necessary fittings all as specified and directed by Engr-in-Charge.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed by Engr-in-Charge.
S&F in repair 15 mm bore gun metal globe or gate valve with iron wheel heads screwed both ends for iron pipe .
M&L for complete removal of existing treatment from old decorated plastered surfaces of walls by Vacuum based sanding machine complete all as specified, removal of nails etc & filling cracks/hole with putty, applying wall care putty upto 1mm thick as required (multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coats oil emulsion distemper white or coloured over a coat of approved primer by auto roller complete all as specified & directed by Engineer-in-Charge.
M&L Preparation old decorated surfaces on ceiling and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and washing with water and applying two coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from old decorated plastered surfaces of walls by Vacuum based sanding machine complete all as specified, removal of nails etc & filling cracks/hole and applying two coat of acrylic emulsion paint over one coat of primer including necessary scaffolding all as specified and directed by Engineer-in-Charge.
M&L Preparation of old painted wooden surfaces of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge.
M&L Preparation of old painted steel surfaces of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster of any description on bricks wall etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed by Engineer-in-Charge
M&L 15mm thick rendering other then fair faces of brick work or concrete surfaces in CM 1:6, finished even and smooth (without using extra cement) all as specified and directed by Engineer-in-Charge.
M&L 5 mm thick rendering on ceiling etc surfaces in CM 1:3, finished even and smooth (without using extra cement) all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering on brick or concrete surfaces in CM 1:4, finished even and smooth (without using extra cement) and using WPC as per manufacturers instruction complete all as specified and directed by Engineer-in-Charge. WPC shall be measured and paid seperately.
M&L fpr Preparing Newly Plastered Surfaces of ceiling and applying Three COATS of WHITE WASHING, complete all as specified and as directed. by Engineer-in-Charge. (Note:- work will be strictly executed by mechinised means/ tools as required for smart periodical services)
M&L for Preparing New Plastered Surfaces of WALLS and applying TWO COATS of DISTEMPER OIL EMULSION (OIL BOUND WASHABLE DISTEMPER) over a Coat of CHALK WHITING, complete all as specified and as directed. by Engineer-in-Charge. (Note:- work will be strictly executed by mechinised means/ tools as required for smart periodical services).
M&L for preparation of new plastered surfaces walls and cornices and applying two coat of acrylic emulsion paint over one coat of primer including necessary scaffolding all as specified and directed by Engineer-in-Charge.
M&L washed stone grit plaster on exterior walls in two layers under layer 12mm cement plaster 1:4 (1cement 4coarse sand) furrowingthe under layer with scratching tool applying cement slurry @ 3kg/sqm top layer 15mm cement plaster 1:1/2:2 ( 1 cement 1/2 coarse sand : 2 stone chipping coloured 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing & washing the top layer with brushes & water to expose the stone chipping and taking down old grit plaster complete all as specified pattern decided by Engr-in-Charge.(payment for providing grooves shall be made separately). Note:- Top layer of shade be of white cement using colouring pigment & stone chipping of desired colour as approved.
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge
S&F in repair 18/19 mm thick prelaminated particle board interior gde prelaminated one side with decorative choice and other side white lamination fixed with screws as in cup board shutters & shelves and pelmet boxes inculding beading etc all as directed.
S&F in repair 25 mm thick Block board interior Gde 2 quality commercial type decorated face veneer on one face fixed with screws as in cup board shelves etc all as directed.
S&F aluminium alloy door seal 1m long fixed to wooden doors complete all as specified and as directed by Engineer-in-Charge.
M&L post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron.complete all as specified and directed by Engr-in-Charge
M&L post construction antitermite Treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified and directed by Engr and Charge.
Dismantling structural steel work incl. steel door, gate, window guard bars, grills etc.
M&L fabricated frame work as in doors /windows frame using MS Box section of required size for making rebate to fix Shutter and other section with gusset plate rails, braces etc. complete drilled for fixing Door Shutter with MS Butt Hinges and hole for tower bolt, sliding boltetc or other covering door etc to be prepared for hanging with and including hinges all as specified and as directed.
M&L for mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engr-in-charge
S&F Steel work in tubular trusses, pillars and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 all as specified and directed by Engr-in-Charge.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed by Engr-in-Charge.
S&F in repair 0.5 mm thick pre coated thick galvalume aluminium zink coated GI based corrougated steel sheeting or curved shape of any colour having tansile strength of 550 MPA as in roof covering/glading to wall fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
S&F 4.0mm thick sheet glass plain pane best quality fixing to Aluminium/Steel/wooden Sections as in Panel of Doors/Windows/Ventilator and Panelling Works with necessary fixing Arrangements viz Jointing Cleats, Glazing Clips, Rubber Packing, Screws, etc. or fixed with Oil Putty, as required/ordered at Site(s), complete and fixed all as specified and as directed.
S&F 4.0mm thick Glass pane figured pin headed type, best quality, fixing to Aluminium/Steel Sections as in Panel of Doors/ Windows Shutters and Panelling Works with necessary fixing Arrangements viz Jointing Cleats, Glazing Clips, Rubber Packing, Screws, etc. or fixed with Oil Putty, as required/ordered at Site(s), complete and fixed all as specified and as directed.
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each with shutters (withour taking off shutters from the frame all as specified and directed by Engr-in-Charge.
Taking down Chowkhats or frames n exc 1.5 Sqm each without taking off shutter from the frame all as specifed and directed by Engr-in-Charge.
S&F 30mm thick factory made flush door shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides all as specified and directed by Engr-in-Charge.
M&L second class hardwood 35mm thickness plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats all as specified and directed by Engr-in-Charge
M&L second class Hardwood 35 mm thickness, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified by Engr-in-Charge.
S&F Pressed steel frames size of 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified by Engr-in-Charge.
S&F mild steel cold rolled medium weight butt hinges 100mm long complete all as specified directed by Engr-in-Charge
S&F stainless steel handle fabricated type, anodised 150mm size complete all as specified directed by Engr-in-Charge
S&F two legged aluminium floor door stopper with rubber shoe 140mm long complete all as specified and directed.
S&F 150 mm stainless steel barrel tower bolts of extruded section and fixed to shutter complete all as specified and as directed by Engineer-in-Charge.
S&F 300mm dia mild steel sliding door bolts, Clip type with bright bolt not less than 12mm dia with a minimum of 6 bolts and nuts, four on bolt plate and two on stapple plate complete all as specified by Engineer-in -Charge.
S&F in repair stainless steel wire cloth with 8% nickle 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple
S&F powder coated (Thickness or powder coating not less than 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F powder coated (Thickness or powder coating not less than 50 micron) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed by Engineer-in-Charge.
S&F aluminium anodized grill DG 208 design as per approved pattern including aluminium beads etc complete all as specified and directed by Engr-in-Charge
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing all as per specified and directed by Engr-in-Charge.
Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface and removal outside the MoD land, complete all as specified and directed.
M&L for 40mm thick PCC (1:2:4) type B-1, using 20 mm graded mechanically crushed stone aggregates as in padding to roof to maintain the required slope and finished the surface even and smooth without using extra cement, complete all as specified and directed.
Material and labour, 10 mm thick cement plaster in CM (1:3) mixed with WPC as per manufacturer’s instructions on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
M&L water proofing treatment of roof consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified. (c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.00 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 150gm/sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed.
Supply only water proofing liquid compoundcomplete all as specified and directed by Engr-in-Charge. :
M&L for appling one coat aluminium heat resistance paint on the roof as per manufacture instructions complete all as specified and directed by Engr-in-Charge.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
M&L for Brick work with sub-Class ‘B’ bricks (with old size bricks), straight or curved on plan exc. 6m mean radius, built in cement mortar 1:4, complete all as specified and as directed.
M&L for salt glazed stone ware gully traps square or rounded mouthed type ‘P’ of size 150x150mm embedded in PCC 1:3:6 type C-1 with and necessary brick work, plastering etc complete and connecting to pipe all as directed by Engineer-in-charge.
M&L Gunitting work for RCC work as in columns, beam, slab, perapet, chajjas etc by removing all loose concrete on the reinforcement, cleaning the surfaces with wire brushes and reinforcement with sand papers than applying apoxy paint to rusted reinforcement and S&F welded wire mesh fabric size not less than 95x95x3 mm on the prepare surfaces and finally applying guniniting 30 to 40 mm thick (average thickness )with presure gun using 1 part of cement and 3 part of coarse cement incl necessary form work where ever required all gunnited surface shall be brought in complete geometric figure even in the guniting opration only complete all as specified and directed. Note:- Where new or additional reinforcement is required the same shall be paid for separetaly of this schedule as above.
M&L for 6 to 8 mm dia TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No 90 here-in-before but in stirrups/binders complete all as specified and directed by Engr-in-Charge.
M&L for Rough finished surfaces concrete formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) all as directed by Engr-in-Charge
M&L for Rough finished surfaces concrete formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5 cm but n exc 15 cm wide all as specified and directed by ENgr-in-Charge
M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (using for 20 mm thick crushed stone aggregate) in slabs supported on walls, bends, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc all as specified and directed by Engr-in-Charge
Dismantling of wall/ floor tile including backing coat any description or any thickness beded and pointed in any cement motar and removal to out of MD land all as specified and directed by Engr-in-Charge
M&L glossy chequered cement concrete tiles 300x300x25mm thick, set jointed and pointed in near cement slurry in floors with white cement and pigments in any colour machine preassed glazed , over cement screed bed 15mm thick cement motor 1:6 all as specified and as directed by Engr-in-charge.make nitco/arena or equivalent all as specified and directed by Engr-in-Charge
M&L non skid ceramic coloured tile 7 to 8mm thick (square/rectangular area of each tiles exceeding 0.11 Square but not exceeding 0.18 Sqm in floor over 15mm thick screed bed in cement motar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the tile all as directed by Engr-in-Charge.
M&L for glazed ceramic coloured designer concept tiles matching with existing tile 350x250x7 or 450x350x7mm size as in walls set and jointed in neat cement slurry over 10mm thick recuing in cement mortar (1:4) and pointed in coloured cement to match for work on vertical surface such as skirting dado etc all as specified and as directed by Engr-in-Charge.
S&F 16 to 18 mm thick granite (any type) machine cut laid over cement screed bed 20 mm thick in cm 1:6 and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including mirror polishing and bull nosing edging in any position etc all as directed by Engr-in-Charge.
M&L 20-25 mm thick machine cut Kota stone slab flooring over cement screed bed 20mm thick in CM 1:6 and jointed with gray cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete all as directed by Engr-in-Charge.
Demolition in cement concrete in ground floor and paving n exc.15 cm thickness (below above ground floor) all as directed by Engr-in-Charge.
M&L PCC for 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating ,as directed coping, benching & for fixing railing, holdfast etc complete.
M&L for cement concrete 1:3:6 type C-1 (20mm graded stone aggregate) 75 mm thick in plinth protection and courtyard, finished cement surfaces even and smooth with out using extra cement , complete all as specified and as directed by Engineer-in-Charge.
M&L providing 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded aggregate in sub base of floor complete all as specified and directed by Engr-in-Charge.
Excavating in trenches, not exc. 1.50m wide and not exc. 1.50 m in depth, for foundation of sewage lines and manhole, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
All as per item No 105 hereinbefore but depth exceeding 1.5 m and not exceeding 3.00M
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and as directed.
Removing excavated surplus soil n exc. 50m at contractor's own arrangement and depositing the soil where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Demolition/Breaking up Drain Pipes (Salt Glazed Ware) 150mm Bore (dia), Jointed in Cement Mortar of any description including PCC of Packing and Haunching to Sides of the Pipes with Bed, complete all as specified and as directed.
S&F of Reinforced cement concrete drain Pipes 150 mm dia NP-2 , laid in trenches in foul condition, Jointed with collars in cement mortar 1:2 and tested, complete all as specified and as directed.
M&L for cement concrete 1:3:6 (20mm Graded crushed stone aggregate) Bed for drain pipes of bore 150mm including packing under and haunching against the sides of pipes after they are laid in foul condition and testing, complete all as specified and as directed.
M&L for Cutting into existing Manhole for removing existing Branch Drain Pipes, Making Good to Brick Wall and Rendering, cutting out Branch Channel and making good in Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) and reforming Benching for 150mm internal dia Drain Pipe in Foul Condition, complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specified and provided (in sunken portion area) , removing demolished material completely and old waste pipe from sunken portion and cleaning the side/bottom surface of sunken floor with wire brush, complete all as specified and directed.
M&L for PCC 1:5:10 type E-2 using 40 mm brick aggregate as in sunken floor slab complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in seal the joints in sunken portion , rounded or chamffered on edges complete all as specified and directed by Engr in Charge.
M&L for providing 50 mm thick cement concrete 1:2:4 using 12.5mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engr-in-Charge.
M&L for 15 mm thick rendening in sunken portion in cement mortar 1:3 including water proofing liquid as per manufacutre as per specification finished fair even and smooth with using extra cement complete all as specified and as directed by Engineer-in-Charge.(water proof liquid paid and measured seprately)
M&L for medium grade 50 mm bore GI pipe fixed in to the sunken portion upto the wall for taking out leakage water and making good to existing surface complete all as specified and as directed by Engineer-in-Charge.
Schedule ‘A’ Part-II (E/M)
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site/Sch of credit and making good disturbed surface of walls, floors, etc., complete all as specified and as directed by Engineer-in-Charge.
M&L point wiring using approved colour coding as per IS with stranded copper conductor single core 1.5 Sqmm (Nominal area), PVC insulated cable in and incl PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc.and with all connecting accessories incl mild steel sunken boxes suitable for mounting switch/sockets with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer incl mounting frame over cover plate, covered with 3mm thick plastic laminated sheet, incl PVC insulated copper conductor 1.5 Sqmm (Nominal area) single core PVC cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified. Note : Switch/sockets shall be measured and paid for separately.
One light/fan point controlled by one switch
One switch socket outlet 3 pin,5 Amp on the independent board
One switch socket outlet 3 pin,5 Amp on same board
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size
All as per item No 123 here-in-before but with 2 single core PVC insulated FRLS and sheathed copper conductor of size 2.5 Sqmm in and including PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc.and with all connecting accessories with 2.5 Sqmm PVC insulated FRLS copper conductor as earth wire and connecting to common earth dolly for 6 pin 16 Amp socket outlet on the independent board.using 2.5 sqmm copper cable incl PVC insulated copeer conductor 1.5 Sqmm as continued earth wire
S&F modular socket outlet 6A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket outlet 6A/16A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch 1 way 6 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch 1 way 16 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose 3 phase/PVC/ polycarbonate isolated body, complete all as specified and as directed by Engineer-in-Charge.
S&F step type elctronic fan regulator Modular type, single phase 220 V , one module type, complete all as specified and as directed by Engineer-in-Charge.
S&F modular bell push switch 1 way 6 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
S&F Bell, AC, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp holder,PVC insulated body, with back plate suitable for batten fitting
S & F LED bulb 10 watt 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S & F Bulkhead luminaire Decorative Energy saving new generation 10W LED IP65 with opal diffuser incl electronics driver & connection with copper flexible cable 3 core complete all as specified and directed.
S & F LED Building security light 25 /30 watt pressure die cast housing with individuals LEDs & Lens with modular secondary optics and IP65 protection with electronics driver and copper conductor 3 core of 0.7 sqmm from ceiling rose to security light with Bracket made out of GI light grade pipe of 32 mm dia 1.5 mtr long bend to an angle of 120 degree with fixing arrangements on wall 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully AC single phase 220/230volt ceiling fan 1200/1400mm sweep single phase complete at site for rewinding and replacement of unserviceable parts i.e Capacitor, PVC connector, MS galvanised check nut, ball bearing, rubber pads, PVC strip clamps including servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin rubber packing and rubber seal etc including testing after assembling and connecting to electric system complete all as specified and as directed by Engr-in-Charge. Note : 1. Rates of winding and replacement of any unserviceable parts mentioned above required to make the fan in serviceable condition are include in the quoted rate. 2. Old winding of the fans will be destroyed/damaged by the department before handing over the fan to contractor for repair. 3. After repair contractor will be fully responsible for checking of copper winding and thereafter the same will be assembed, re-hanging and electric connection complete. 4. Rates of bearing, bush, capacitor, blades & painting will be paid seperately in the concered item of schedule.
All as per srl item No 143 above but for exhaust fan of size 250mm sweep plastic type square/round shape complete
All as per srl item No 143 above but for exhaust fan300mm sweep complete all as specified and directed.
S&F in replacement capacitor 2.5 mfd + 5%, 220/230 volts AC, 50 c/s complete all as specified and directed.
S&F Electric cable PVC insulated with copper conductor (flexible cable) size 23/0.0076 twin core for connecting fan to electric system, complete all as specified & directed.
M & L for Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes to ceiling fan of 1200/1400mm sweep of any make complete all as specified and directed.
Taking down and Spray painting to AC ceiling fan 1200/1400mm sweep any make complete to motor assy, down rods, blades with ISI marked white/brown synthetic enamel paint as approved by Engr-in-Charge after preparation of surface including filling cavities with filler, writing of MES No complete and refixing the same in existing location after painting complete all as specified and as directed by Engr-in-charge
Taking down metallic type exhaust fan upto 450 mm sweep in situ for spray painting with ISI marked OG/brown/black synthetic enamel paint as directed by Engr-in-charge after preparation of surface and refixing the same in existing location after painting complete all as specified and as directed by Engr-in-charge
Canopies for AC ceiling fan of size 1200/1400mm sweep for any make of fan.complete all as specified and as directed by Engr-in-charge
S&F down rods for ceiling fan 1200/1400mm sweep of size 2.5' long duly painted with white synthetic enamel paint complete all as directed by Engr-in-charge
S & F Hanging clamp suitable for ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as directed by Engr-in-Charge.
S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 12 way, 415 Volt TPN
S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 8 way, 240 Volt SPN
S & F MCBs 'B' characteristics, Four pole , 415 V,63 Amp breaking capacity 10 kA
S & F MCBs 'B' characteristics, Double pole , 240 V, 40 Amp breaking capacity 10 kA 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S & F MCBs 'B' characterstic single pole 5 to 30 Amp, 240 volt breaking capacity 10 kA
Taking out old U/S submain wiring of any size and removing materials to store or as sch of credit including making good of existing surfaces complete all as specified and as directed.
M&L for submain wiring with in replacement 2 single core PVC insulated FRLS cable 6 Sqmm copper conductor PVC sheathed in and including rigid PVC concealed conduit heavy duty of suitable size incl cutting chiseling of wall and making good to disturbed surface of walls / floor etc with plastering painting etc so as to match with the existing finishes, drawn with 6 Sqmm PVC insulated FRLS copper conductor cable for earth wire fixed with shaddle and connecting to common earth teriminals complete all as specified.
Earthing complete with and including galvanised steel earth plate electrode 60 cmx 60cm x 6 mm thick surrounded by mixture of charcoal and salt in alternate layers , buried directly in ground vertically in a pit of depth not less than 2.25 meter deep below ground level with top as of the plate at a depth of not less than 1.5 mtrs below normal ground level connected to galvanized iron or steel earth lead wire 4.0 mm dia,( NO 8 SWG) by means of bolts ,nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15 mm bore (light grade) and connected to main switch or main control board all as shown in electrical plate No. 3 of SSR - 2009(Pt I) & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers, 20 mm bore GI pipe (Light grade ) for watering , protection pipe funnel, wire mesh , PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25 ( Normal mix) cover duly reinforced with XPM (weight not less than 3 kg /sqm ) and CI frame etc , and including provision of test point , connecting to test point and testing on completion etc, complete all as specified. NOTE : The unit rate include earthing lead and protection pipe upto 6.5 metre from top of earth plate.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron or steel wire complete all as specified.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 16 Sqmm 4 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 10 Sqmm 2 core, complete as sepecified and directed by Engr-in-Charge.
Excavation in trenches in hard/tense soil not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out including dressing / trimming sides and leveling/grading and ramming of bottom of excavation complete as sepecified and directed by Engr-in-Charge.
Returning, filling in including spreading, leveling, watering and well raming excavated soid in layers not exceeding 25 cm thick, filling back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested complete as sepecified and directed by Engr-in-Charge.
Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.nexc 1.5 mtr above starting point where directed complete as sepecified and directed by Engr-in-Charge.
M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as sepecified and directed by Engr-in-Charge.
Supply and Laying Bricks old size sub class 'B', of class designation 10, for the protection of cable laid flat dry across the cable complete as sepecified and directed by Engr-in-Charge..
Tubes, light grade, galvanised 40 mm dia with all fittings laid in trenches or fixed on walls etc complete all as specified and as directed by Engineer-in-Charge.
M&L for taking down energy meter 1 phase from meter box after disconnecting all incoming and outgoing connection and deposite to MES store complete all as specified and as directed by Engr-in-charge
M&L for fixing only energy meter 1 phase upto 25 Amp from meter box after connecting all incoming and outgoing connection all as specified and directed by Engr-in-charge
M&L complete for drilling hole under hard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying of pipe for protection of cable etc by means of mannual bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified.
Schedule of Credit
Phogat Builders (BID ID -3094073)
PAWAN KUMAR (BID ID -3090883)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .