Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹21.0 L+₹8,116 (0.39%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹22.7 L+₹1.8 L (8.46%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹27.5 L+₹6.6 L (31.4%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-AOC Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
3 May 2021, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINT OF SUBMERSIBLE PUMP SETS AND DEVELOPMENT OF BOREWELLS IN THE AREA OF AGE U WATER SUPPLY II UNDER GE U WATER SUPPLY DELHI CANTT 10
2021_MES_434919_1
GE/WS/D-22 of 2021-22
Open Tender
Civil Works
Item Rate
120 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹50,000
Yes
26 Jun 2021
7 Apr 2021
5 May 2021
7 Apr 2021
3 May 2021
21 Apr 2021
Amount
Disconneting of electrical connection from the panel board, and starter of submersible pumping set of any model / make size 2 HP to 20 HP capacity and removing the pipe line connection from discharge side and taking out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to Workshop and back after repair and lowering of same pumping bore well including replacement of rusted nuts bolts rubber gasket etc to make it fully functional, testing complete all as specified and as directed
All as per srl item No 1 here in before but 25-40 HP
Disconneting of electrical connection from the panel board, and starter of submersible sewage pump of upto 7.5 HP capacity and removing the pipe line connection from discharge side and taking out submersible pump set along with column pipe from sewage bore well of defth 50 ft with the help of chain pully block including transportation to Workshop and back after repair or cleaning the suction side with impeller of pump set by removing sladge, blockage, polythene and other foreign material and lowering of same pumping bore well including replacement of rusted nuts bolts rubber gasket etc to make it fully functional complete all as specified and as directed
Opening the submersible pump set / sewage pump set of capacity 2.00 to 20.00 HP including taking down/out the burnt winding wire cleaning the slots, rewinding the motor with super enamelled copper winding wire of existing gauge, weight etc, repairing the same by replacing the unserviceable parts including machine/ lathe work and re-assembling the pump set in original position with required insulating material to make it fully functional complete all as specified and as directed
All as per srl item no 4 here in before but 25.00 to 40.00 HP
Supplying and winding super enamelled copper winding wire of appropriat gauge and weight suitable up to 40HP pumping sets complete all as specified and as directed
Supply only G M bush for submersible pump set capacity 2-20 HP.
Rotar sleeve
Water seal and cable seal
Thrust bearing segment
Revolving Disc
CI Connection piece
Sand guard
Sealing ring
CI upper housing
CI Lower housing
Rotar sleeve turning and grinding
Remetling of Rotar end turning and making key way
Flange upper with stud and nut
Flange lower with stud and nut
Repairing of stamping for motor
Seal bush
Thrust plate
Stainless Steel coupling
Stud and nut for connection piece
Balancing of Rotar
T-Bolt with nut
LNK Bolt Stainless Steel
Submersible cable jointing
CI Suction chamber
CI stage bowl
G.M Impeller
EPV Impeller
EPV Stage bowl
Guide Bush
DOL G M Bush
Stainless Steel DOL Sleeve
Inter Ring
CI DOL Piece
CI NRV Body
Impeller Key
Stainless Steel Pump shaft single stage
Remetling of G.M Impeller and turning
Stainless Steel Distance sleeve
Pump sand guard
Hook Bolt with nut
G.M Neck ring
MS Stud with nut
Wiremesh
Drain Plug
EPV Defuser
Material and labour for painting of submersible pump set of size 2 HP to 40 HP with two coat of synthetic enamelled paint over coat of red oxide primer complete all as specified and as directed
Supply only G M bush for submersible pump set capacity 25-40 HP
Rotar sleeve
Water seal and cable seal
Thrust bearing segment
Revolving Disc
CI Connection piece
Sand guard
Sealing ring
CI upper housing
CI Lower housing
Rotar sleeve turning, grinding& polishing
Remetling of Rotar end turning and making key way
Flange upper with stud and nut
Flange lower with stud and nut
Repairing of stamping for motor
Seal bush
CI Motor Base
Thrust plate
Stainless Steel coupling
Stud and nut for connection piece
Key for SS coupling
Balancing of Rotar
T-Bolt with nut
LNK Bolt Stainless Steel
Submersible cable jointing
CI Suction chamber
CI stage bowl
G.M Impeller
EPV Impeller
EPV Stage bowl
Guide Bush .
DOL G M Bush
Stainless Steel DOL Sleeve
Inter Ring
CI DOL Piece
CI NRV Body
Impeller Key
Stainless Steel Pump shaft single stage
Remetling of G.M Impeller and turning
Stainless Steel Distance sleeve
Pump sand guard
Hook Bolt with nut
G.M Neck ring
MS Stud with nut
Wiremesh
Drain Plug
EPV Defuser.
M&L for replacement of heavy duty GI nipple 300 mm long and 40 mm bore with flange welded on both ends complete all as specified and as directed
M&L for replacement of heavy duty GI nipple 300 mm long and 80 mm bore with flange welded on both ends complete all as specified and as directed
M&L for replacement of heavy duty GI nipple 300 mm long and 50 mm bore with flange welded on both ends complete all as specified and as directed
Supply and fixing water proof submersible cable 3 core copper conductor, PVC insulated 1100 volts grade, protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable complete all as specified and as directed
Material and labour for pin point the fault by arranging fault locating machine in any size of LT UG cable from any location/position/situtation, taking down/out the faulty portion of cable, of any length from trenches, jointing with cable jointing kit & testing for satisfactorily serviceable with & including necessary excavation and earth work, sand cushioning and making necessary connections to make it functional complete all as specified and as directed. Note :- (i) Cable jointing kit shall be measured and paid seperetely. (ii) Old retrieved bricks/cable cover shall be reused (iii) The rates quoted includes excavation & earth work with sand cushioning.
Material and labour for cable joint kit of size 3.5 core 35 sqmm for heat shrinkable straight through joint complete all as specified and as directed
Material and labour for cable joint kit of size 3.5 core 50 sqmm for heat shrinkable straight through joint complete all as specified and as directed
Material and labour for cable joint kit of size 3.5 core 70 sqmm for heat shrinkable straight through joint complete all as specified and as directed
Material and labour for cable joint kit of size 3.5 core 95 sqmm for heat shrinkable straight through joint complete all as specified and as directed
Labour only to remove submersible pump set upto 25 hp capacity from dry/dead borewell including removal of column pipes/cables and transportaion charges, to kept in MES store yard complete all as specified and as directed
Supply and fixing GI Pipe column pipe heavy grade, 80 mm bore 3 mtrs long coupled with heavy grade suitable size of MS flanges 16mm thick duly welded on both sides as directed including necessary nut and bolts with washers & rubber packing required at site condition and lowered in to the bore well including taking out old unserviceable Column pipe complete all as specified and as directed. (length of each column pipe shall be 3 Mtrs) (Note : - taking out and Lowering of Submersible pump set shall be measured and paid under respective item)
All as per Srl item No 110 above but size of pipe 50mm bore
Supply and fixing MS clamp in MS flat 50mm X 6mm with two Nos of MS nut & bolts for 50mm dia column pipe
Supply and fixing MS clamp in MS flat 80mm X 6mm with two Nos of MS nut & blots for 80mm dia column pipe
Supply and fixing casing cover for heavy duty for 150mm dia of pipe
Supply and fixing well cap suitable for 250 / 300 mm bore pipe consisting of two parts complete with welding and machinery work having provision of cut out for passing of column pipe and fabricated out of mild steel sheet 3.15 mm thick complete all as specified and as directed
Supply and packing pea gravel of size 3mm to 6 mm around casing / housing pipe complete all as specified and as directed
Material and labour for brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) complete all as specified and as directed
Material and labour for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, flooring sub base complete all as specified and as directed
Demolition of cement concrete un-reinorced, of any discription and in any position not otherwise specially provided for i.e around the tube well without disturbing the casing/housing pipe complete all as specified and as directed
Disconecting water pipe line, electric connections and taking down/out submersible pump set, of any capacity, from any location/depth alongwith column pipe, submersible cable including re-lowering the same after developing the borewell including replacement of rubber gasket, nut, bolts and washer etc whenever required complete all as specified and as directed
Transportation of air compressor with tools and accessories at different location in delhi cantt area for devlopment of borewell complete all as specified and as directed
Development of bore well if any capacity size, not more than 150mtrs deep, at the prssure not less than 6 Kg/Sqcm by disel engine driven air compressor of capacity 450cfm with & including air pipe and connected items to achieve the minimum yield of 3 litres per second of tube well complete all as specified and as directed
Development of bore well, if any capacity size, not more than 160mtrs deep, at the pressure not less than 6 Kg/Sqcm by disel engine driven air compressor of capacity 630cfm with & including air pipe and connected items to achieve the minimum yield of 3 litres per second of tube well complete all as specified and as directed
Supply and fixing in replacement of mild steel nuts, bolts & washers etc of any size complete all as specified and as directed
Supply and fixing in replacement of rubber packing suitable for flange 50mm dia complete all as specified and as directed
Supply and fixing in replacement of rubber packing suitable for flange 80mm dia complete all as specified and as directed
Supply and fixing in replacement of rubber packing suitable for flange 100mm dia complete all as specified and as directed
Supply and fixing in replacement Amp meter as per existing model up to 50 Amps.
Supply and fixing in repair of analog timer switch dial type 24 hours
Taking down old unserviceable any type of starter any size and supply and fixing new ML 1.5 FASD with ML relay range 13-21 A including stainless steel box existing starter panel complete all as specified and as directed
Taking down old unserviceable any type of starter any size and supply and fixing new ML 2 FASD with ML relay range 20 - 32 A including stainless steel box existing starter panel complete all as specified and as directed
Supply and fixing power contactor MNX-18, 32 Amps,240 volts, 50 HZ suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed
Supply and fixing power contactor MNX-25, 45 Amps,240 volts, 50 HZ suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed
Supply and fixing power contactor MNX-32, 55 Amps,240 volts, 50 HZ suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed
Supply and fixing power contactor MNX-40, 55 Amps,240 volts, 50 HZ suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed.
Material and labour 6 Sqmm PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and as directed
Material and labour 10 Sqmm PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and as directed
Material and Labour for DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 9523 complete all as specified and as directed
Upto 100 mm bore
Upto 150 mm bore
Material and Labour for CI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 1538-1993 complete all as specified and as directed
Upto 100 mm bore
Upto 150 mm bore
Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') laid in trenches or on floors for connections to centrifugal/Submersible pump sets for suction, delivery pump to header and to connect out going water main CI/DI pipe line complete all as specified and as directed Note:- (i) MS Flanges and Flange joints complete with jointing materials shall be measured and paid separately.
80 mm bore
100 mm bore
150 mm bore
Supplying and fixing, MS flanges of 100 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed
Supplying and fixing, MS flanges of 150 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed
Supplying and fixing, MS flanges of 80 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed
Supplying and fixing, MS flanges of 50 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed
Taking down the unserviceable terminal block any type and supply and fixing new one terminal block 100A - 3 way (For MU-G30/50) complete all as specified and as directed
Taking down old UNSV any type changeover switch and S&F Off-load changeover switches 415V, 50 Hz 63Amps 4 Pole on existing pole/wall complete all as specified and as directed
Taking down old UNSV any type changeover switch and S&F Off-load changeover switches 415V, 50 Hz 100 Amps 4 Pole on existing pole/wall complete all as specified and as directed
Taking down old unsv relays and supply and fixing new thermal over load relays fixing at existing site complete all as specified and as directed.
ML 1.5 relay range 6-10 Amp
ML 1.5 relay range 10-16 Amp
ML -2/3 relay range 9-14 Amp
ML-2/3 relay range 13-21 Amp
ML-2/3 relay range 14-23 Amp
ML -2/3 relay range 20-32 Amp
ML -2/3 relay range 28-42 Amp
Supply and fixing single phase preventor, type VSP-II after taking down/out preventor as existing at site complete all as specified and as directed
Supply and fixing submersible pump controller starter in sheet metal enclosure with volt meter and ampere meter, motor rating 415 Volts, 3 phase, 50 Hz for 4.5 KW motor, Model No MU-G6, after taking down/out breaker as existing at site complete all as specified and as directed.
Supply and fixing MCB 6-32 amps, 230 volts 'C' series single pole in the existing MCB DB including removing existing unserviceable MCB's
Supply and fixing MCB 4 pole 63 Amps, 415 volts TPN in the existing MCB DB including removing existing unserviceable MCB's
Supply and fixing in repairs MCCB 63 Amps 25 KA, 3 Pole inlucding studs in existing LT panel fixing complete all as specified and as directed.
Supply and fixing in repairs MCCB 100 Amps 25 KA, 3 Pole inlucding studs in existing LT panel fixing complete all as specified and as directed
Supply and fixing in repairs MCCB 125 Amps 25 KA, 3 Pole inlucding studs in existing LT panel fixing complete all as specified and directed.
An amount of Rs 39153.60 shall be deducted from BOQ on account of schedule of credit
Sumit Enterprises
Rahul Enterprises
P S TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .