Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹54.2 L+₹4.8 L (9.75%)Rejected-AOC | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Firm being one below eligible class, not submitted/uploaded shortfall document as per note No 1 and 2 of NIT | |
| 4 | Rejected-Technical 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | - | Rejected-Technical Not enlisted in appropriate category | |
| 5 | Rejected-Technical 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
21 May 2022, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
PERIODICAL MAINT, REPAIRS TO RADAR OTP, MISC REPAIRS TO FIRE ALARM AND SAFETY SYSTEM, LOOP CARD, WATER SPRINKLER SYSTEM, SMOKE DETECTORS AND REPAIRS TO LT PANEL BOARD AT LRDE TECH AREA AND NEW CAIR BENGALURU
2022_MES_518096_1
GE(I)/R ND D/BAN/TOKEN/08 OF 2022-2023 8962/E8
Open Tender
Civil Works
Item Rate
330 days
Bengaluru
Class and Category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹94,000
Yes
20 Jul 2022
22 Apr 2022
27 May 2022
23 Apr 2022
21 May 2022
8 May 2022
23 Apr 2022 - 7 May 2022
Amount
Disconnecting electrically operated squirrel cage crane heavy duty motor of cap 13.4 HP, AC 3 phase, 415 Volts from existing location of electro mechanically driven winch unit by unscrewing of nuts, bolt and dismantlling all parts carefully, checking all components in and including servicing, greasing, oiling etc as applicable for smooth functioning complete all as per site requirements and reassembling, alignment of motor complete with electro mechanically driven winch unit and testing complete all as specified and directed. Note : (i) The job can be paid maximum of twice in the contract period with an interval of Six months periodcity. (2) If motor condition demands varnishing / insulation or rewinding works during servicing, the same shall be measured and paid separately under relevent item of this schedule.
Disconnecting motor of cap 1 HP 3 Phase 415 Volts in respect of locking pin unit from existing location of RTP by unscrewing of nuts, bolt and dismantlling all parts carefully, checking all components in and including servicing, greasing, oiling etc complete all as per site requirements and reassembling, alignment of motor complete with the existing pin unit and testing complete all as specified and directed. Note : The job can be paid maximum of twice in the contract period with an interval of Six months periodcity
Labour only for applying Greasing to spindles, guide rollers, platform locking pins etc arrangements of winch assembly unit - 01 No using necessary tools and plants, gease gun etc after dismanling all components carefully, removing of existing old grease and other lubricating materials from all parts by rubbing, scrapping and cleaning with the cotton waste, diesel and other cleaning material as applicable etc and applying fresh grease, assembling all parts carefully,alignment with winch unit properly testing complete all as specified and directed. NOTE:- (i) Grease shall be measured and paid separately here-in-after schedule item as SUPPLY only (ii) The job can be paid maximum of twice in the contract period with an interval of Six months periodcity
Labour only for applying Black cadmium compound to hoisting mechanism wire ropes, rope drum and rope pulleys of winch assembly - 01 No using necessary tools and plants etc after dismanling all components carefully, removing of existing old cadmium compound and other lubricating materials from all parts by rubbing, scrapping and cleaning with the cotton waste, diesel or other any cleaning material as applicable etc and applying fresh cadmium compound, assembling all parts carefully, alignment with winch unit properly, testing complete all as specified and directed. NOTE:- (i) Cadmium shall be measured and paid separately here-in-after as SUPPLY only (ii) The job can be paid maximum of twice in the contract period with an interval of Six months periodcity
Labour only for opening winch gearbox screws and nuts bolts, dismanling all components carefully, draining out existing oil from gearbox of winch assembly unit - 01 No using necessary tools and plants etc removing of old sludge and foreign material from gear box complete, overhauling of gear box parts complete and cleaning with the cotton waste, diesel or other any cleaning material as applicable etc and filling gear oil carefully, reassembling, alignment with winch unit properly, testing complete all as specified and directed. NOTE:- (i) Gear oil for filling / top up shall be measured and paid separately here-in-after as SUPPLY only (ii) The job can be paid maximum of twice in the contract period with an interval of Six months periodcity
Labour only for disconnecting electro hydraulic thruster operated brake from winch assembly unit, dismantling all components carefully, draining out existing hydraulic oil using necessary tools and plants etc removing of old sludge and foreign material from thruster unit complete, overhauling of thruster brake system complete and cleaning with the cotton waste, diesel or other any cleaning material as applicable etc and filling hydraulic oil carefully, reassembling, alignment with winch unit properly testing complete all as specified and directed. NOTE:- (i) Hydraulic oil for filling / top up shall be measured and paid separately here-in-after as SUPPLY only
Taking up defective electrically operated squirrel cage crane duty motor of cap 13.4 HP, AC 3 phase, 415 Volts from existing location, checking, measuring no load current, IR value and winding resistance using micro ohm meter before winding insulation / varnishing to windings and dismantling of motor, measuring stator and rotor ID, carry out dynamic balancing of rotor if required, applying insulation varnish material to windings after removal of defective varnishing/insulations etc, assembling of motor, carry out no load current and KW study and alignment of all the loosen parts including re-fixing, connections, testing and commisioning complete all as specified and directed.
Taking up defective electrically operated squirrel cage crane duty motor of cap 13.4 HP, AC 3 phase, 415 Volts from existing location, checking, measuring no load current, IR value and winding resistance using micro ohm meter before rewinding works and dismantling of motor, taking out defective wires rewinding with best quality existing gauge copper of existing gauge with new insulation materials, varnishing, heating, reassembling, testing, assembling of motor, carry out no load current and KW study and alignment of all the loosen parts including transportation and back including re-fixing, connections, testing and commisioning complete all as specified and directed.
Taking up defective motor, 3 phase, 415 Volts, AC 1 HP capacity from the existing location, dismantlling, removing the burn out winding, rewinding with same gauge copper wire, insulating, varnishing, reassemble parts, re-fixing in the same position, testing and commissioning complete all as specified and directed.
Taking up defective mono block pumpset centrifugal motor of cap 5 HP AC 3 phase, 415 Volts complete from the existing location by unscrewing of nuts, bolt, dismantlling all parts, checking bushes, bearings and all other parts carefully, overhauling works to pump and motor complete in and includoing replacement of worn out bushes, bearings, rewinding works, varnish works complete as per site requirements and reassembling, alignment of motor with pump set complete in all respects, testing and commissioning complete all as specified and directed.
Supply only Grease in 20 kg bucket for Greasing spindles, guide rollers, platform locking pins etc of Radar Test Platform complete all as specified and directed. Make : Castrol (Premium longlife) or equivalent specifications as apporved by GE.
Supply only Black cadmium compound in 18 kg bucket for hoisting mechanism wire ropes, rope drum and rope pulleys etc of Radar Test Platform complete all as specified and directed. Make : Balmerol (Bluecoat 2B) or equivalent specifications as apporved by GE.
Supply only Gear Oil 90 grade or equivalent type suitable for filling / top up in winch gear box as per site conditions complete all as specified and directed.
Supply only hydraulic oil as per existing grade suitable for winch thruster break complete all as specified and directed.
Dismantlling, taking up old existing electro hydraulic Thruster operated brake assembly KTM type complete from the existing location of RTP winch unit including supply, install, testing and commissioning electro hydraulic Thruster operated brake assembly unit KTM type 415 Volts complete, three phase, 50 Hz all as per site requirements in and including with all connected items by using necessary tools and plants complete all as specified and directed.
Material and labour for replacement of Break shoe assembly with liner complete all as specified and directed.
Material and labour for replacement of Coupling suitable for 1 HP motor complete all as specified and directed.
Supply and fixing for replacement break drum Coupling 200 mm dia suitable for winch unit as per site conditions complete all as specified and directed.
Supply and fixing for replacement rotary limit switch near pin locking system of RTP type RLS -48, 415 Volts, 40 Amps as per site requirements complete all as specified and directed.
Supply and fixing for replacement Lever type Limit Switch type - KLS, 415 Volts, 40 Amps complete as per site requirements complete all as specified and directed. Make :- Radiant Machines Pvt Ltd or equ specifications model of any make as approved by GE.
Taking down existing old and defective aviation lights of any type and model complete from the existing positions of RTP including supply, mounting, fixing and testing single aviation LED light fitting, not less than 45 watt, red colour aluminium body complete ISI marked suitable for existing RTP site requirements complete all as specified and directed.
Material and labour for replacement PVC insulated cable armoured copper conductor of size 1.5 Sqmm FRLS drawn through existing conduit of any type and size surface type including all accessories complete for RTP lights / avaition lights as applicable complete all as specified and directed.
Taking down old unserviceable conventional bulkhead fitting of any type from RTP existing locations including supply, mounting, fixing and testing bulk head fitting LED 10 Watt outdoor type complete with necessary holes, clamp arrangements etc on RTP as per site requirements complete all as specified and directed. Make:- Crompton model LBHP 10 CDL or or techno commercially equivalent makes specified here-in-after.
Taking down old existing outdoor type push button box from the existing location of RTP including supply, fixing, testing and commissioning outdoor type push botton box 4 way of NO / NC 16 Nos system for RTP hoist, lower lock and unlock etc in and including connected wirings complete all as specified and directed.
Checking of existing electro driven Four winch units control panel control wirings, connected control fuses, relays, connected parts and metering controls etc, taking out HRC fuses, over load protection relays and connected components, cleaning, resetting, caliberation of all items with metering instruments including replacement of unserviceable minor nature parts and testing in all respects all as per site conditions complete all as specified and directed.
Taking down existing old and defective load cell display panel of Radar testing platform from the existing positions complete located in the command control room in and including disconnecting control wires of load cells - 08 Nos from rope anchor positions of height 30 mtr (Appx) and panel, load cells - 04 Nos and other connected all items carefully using required tools and plants as per site conditions complete all as specified and directed.
Supply, errection, fixing, caliberation, testing and commissioning of New electronics display system for Radar Testing platform weight monitoring system for weighing cap 80 Ton, weighing zone 8, No. of load cells - 08 Nos, Resolution 20 kg (Appx), system accuracy +/- 2% of full scale, 230 Volt, AC comprising of Loadcell - rope type tension loadcell, loadcell cap 5 Ton, No of load cells - 08 Nos,Smart card - input 8 channel load cell input from load cell, output 5Volt DC for loadcell excitation - RS485 output, ADC 24 bit sigma Delta, ADC, Power supply - mode SMPS module, Digitiliser - type Digital microprocessor based, input mV from loadcell through smart card, display Digital 13 mm LED, No of display 5 (For individual weight 04 Nos, for total weight 01 No) Wall mounting 230 Volts AC complete all as specified and directed. Make:- Electroweigh instruments or equivalent specification model of any make as approved by GE. Note : (i) The firm is responsible to have a visit on RTP site before quoting their amount for ibid job (ii) Item No. 30 & 31 shall be measured and paid separately as SUPPLY only and all other items and spares are inclusive in the quoted rate and no extra amount shall be paid in this regard (iii) The quoted firm is responsible to obtain drawings and detailed specifications from manufactureres and submit their drawings and specifications to the Deptt for approval before placing the order.
Supply only rope tension load cell as per site requirements of RTP complete all as specified and directed.
Supply only signal special cable as per site requirements of RTP complete all as specified and directed.
Taking down existing old and defective Indoor LT panel board from the existing positions complete located in the RTP control room and including disconnecting all incoming, out going cables and other connected all items, set aside carefully using required tools and plants as per site conditions complete all as specified and directed.
Taking out the existing old LT Under Ground cable off sizes including loop of under mentioned sizes from panels/duct /trench/loop etc near the sub stations/pole/buildings/panels iafter disconnecting cables both ends, tracing out the fault with the help of megger and other tests as per site requirement for following cables complete all as specified and directed. Note:i) Earth work as applicable shall be measured and paid separately under relevent items. ii) Retrived bricks from site shall be properly stacked aside and reused as protection to U/G cable here-in-after.
Relaying only cables as obtained against item no.33 here-in-before as per site requirements and carrying out necessary connections in and including new lugs complete all as specified and directed. Note - i) Straight through Epoxy joints/water proof tape joints as applicable on site are inclusive in the quoted rate.
Supply and lay cable LT XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core 1100 Volt grade cable complete all as specified and directed.
Supply and lay cable LT XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core 1100 Volt grade cable complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide not exc. 1.5 m in depth; for laying of cables not exc. 10 Sqm on plan and getting out , trimming sides, forming bottom surface to required level complete in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick as in soils complete all as specified and directed.
Removing of excavated soil to a distance not exc. 50m and depositing where directed at a level n.exc 1.5m above starting point complete all as specified and directed.
Material and labour for sand cushioning (using River-Sand) in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Material and labour for burnt bricks sub class 'B' bricks of size 230 x 115 x 75 mm laid in trenches for cable protection complete all as specified and directed.
Relaying of old burnt bricks sub class 'B' bricks of old size removed from trenches of cable complete all as specified and directed.
Supply and laying GI tubing light grade 80 mm bore as cable protection fixed on wall/pole/laid in trenches including removal of old unserviceable pipe complete all as specified and as directed.
Supply, fabricate, installation, testing and commissioning self supporting totally enclosed factory fabricated LT panel board indoor type made out of not less than 2 mm with CRCA sheet from CPRI Certified validated panel manufactureres with rear side closed and not openable, only front openings compartmental wise, ventilating louvers, dust and vermin proof neorprene rubber gasket, powder coated including danger plate, double earth strip connection provisions - 02 Nos, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc suitable for 3 phase 4 wire, 415 vots, 50Hz mounted on suitable size MS channel or PCC foundation, comprising the folowing :-
(2) The quoted firm is responsible to obtain drawings and detailed specifications from manufactureres and submit their drawings and specifications to the Deptt for approval before placing any order to manufactureres. (3) The quoted firm is responsible for using Aluminium Bus bar / link bus bar connections of proper rating only shall be provided for connections in the panel from Incomer MCCBS - 02 Nos to change over swittch, change over switch to main bus bar, main bus bar to out going MCCBs upto 100 Amps and copper cable proper cables for MCCBs 63 Amps and below switch gear and the cost is inclusive in the quoted rate complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m in replacement complete all as specified and as directed by Engineer-in-charge.
Material and labour for, earthing complete with GI earth plate electrode 600 x 600 x 6 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth strip of 32 mm x 6 mm by means of bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering funnel wire mesh, PCC chamber in CC (1:3:6), type C1 , manhole cover with RCC (1:2:4), type B1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTES :- (i) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Material and labour for, earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to Copper earth strip of 20 mm x 3 mm by means of bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering funnel wire mesh, PCC chamber in CC (1:3:6), type C1 , manhole cover with RCC (1:2:4), type B1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTES :- (i) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Checking Servicing of Existing of Main Electrical Pump of capacity 25 to 50 HP, Greasing and Oiling of all Pump parts and Couplings, Checking the alignment of pump with motor, Coupling and shaft,Checking of cable terminals, foundation Bolt tightening as per site requirements, testing of pump after completion of work complete all as specified and directed. Note : The job can be paid maximum of twice in the contract period with an interval of Six months periodcity.
Checking Servicing of Existing of Jocky Pump of capacity upto 15HP, greasing and oiling of all pump parts and couplings, checking the alignment of pump with motor, coupling and shaft, checking of cable terminals, foundation bolt tightening as per site requirements, testing of pump after completion of work complete all as specified and directed. Note : The job can be paid maximum of twice in the contract period with an interval of Six months periodcity.
Checking Servicing of booster Pump of capacity upto 10HP, greasing and oiling of all pump parts and couplings, checking the alignment of pump with motor, coupling and shaft, checking of cable terminals, foundation bolt tightening as per site requirements, testing of pump after completion of work complete all as specified and directed. Note : The job can be paid maximum of twice in the contract period with an interval of Six months periodcity.
Supply and Installation of Female Coupling - Gun Metal of 63mm dia in replacement complete all as specified and directed.
Supply and installaiton of 63mm dia gun metal branch pipes with detachable gun metal nozzles as per existing and suitable site requirements, in replacement complete all as specified and directed.
Supply and installation of RRL Hose - 15 Mtrs Long 63mm dia as per existing and suitable site requirements with one set of gun metal female and male instantaneous coupling, in replacement complete all as specified and directed.
Supply and Installation of glass for Hydrant Box with rubber beading as per existing and suitable site requirements, in replacement complete all as specified and directed.
Supply and installaiton of Pressure Gauge 0 to 16 Kg/cm2 as per existing and suitable site requirements, in replacement complete all as specified and directed.
Supply and installaiton of key for hydrant box as per existing and suitable site requirements, in replacement complete all as specified and directed.
Supply and installation of Hydrant Lug for hydrant valve as per existing and suitable site requirements, in replacement complete all as specified and directed.
Supply and installation of Spindle Washer for Hydrant Valve as per existing and suitable site requirements, in replacement complete all as specified and directed.
Supply and installation of rubber blank cap for hydrant valve outlet of size 63mm dia in replacement complete all as specified and directed.
Supply and installation of Shut off Nozzle, PVC type fixed at the end of rubber hose in the hose reel drum in replacement complete all as specified and directed.
Supply and Installation for replacement 8mm / 10mm Gland Rope for Jockey pump-01 No, Electrical Pump - 02 Nos, Booster pump - 03 No as per existing and suitable site requirements in replacement complete all as specified and directed. Note : The job can be paid maximum of twice in the contract period with an interval of Six months periodcity.
Supply and installation of Swing type hose reel drum with 19 mm diameter, 30 M long rubber hose including nozzles etc as per existing and suitable site requirements in replacement complete all as specified and directed.
Material and labour for applying one coat of synthetic enamel paint red colour and black colour etc all as per site requirement, best quality all weather protect proof type for Fire hydrants of 1.5 mtr height including fire hydrant valve handle and bottom sluice valve, handle etc complete all as specified and directed.
Material and labour for applying one coat of synthetic enamel paint red colour etc all as per site requirement, best quality all weather protect proof type for Fire brigade 4 way of 1.5 mtr height including handle etc complete all as specified and directed.
Rectification of defective fire alarm system, including servicing checking caliberation testing of existing fire alarm panel, connected wiring system, detectors and devices of make - RAVEL at MLCP, LRDE complex by checking cable continuity, checking and repairing of fault in the system, activation of MCP settings including making serviceable entire system complete all as specified and directed.
Rectification of defective fire alarm system, including servicing checking caliberation testing of existing fire alarm panel, connected wiring system, detectors and devices of make - APOLLO at RADL, LRDE complex by checking cable continuity, checking and repairing of fault in the system, activation of MCP settings including making serviceable entire system complete all as specified and directed.
Rectification of defective fire alarm system, including servicing checking caliberation testing of existing fire alarm panel, connected wiring system, detectors and devices of make - RAVEL at EMP, LRDE complex by checking cable continuity, checking and repairing of fault in the system, activation of MCP settings including making serviceable entire system complete all as specified and directed.
Rectification of defective fire alarm system, including servicing checking caliberation testing of existing fire alarm panel, connected wiring system, detectors and devices of make - RAVEL at A3MTDC, LRDE complex by checking cable continuity, checking and repairing of fault in the system, activation of MCP settings including making serviceable entire system complete all as specified and directed.
Rectification of defective fire alarm system, including servicing checking caliberation testing of existing fire alarm panel, connected wiring system, detectors and devices of make - Notifier at Networking block, CAIR complex by checking cable continuity, checking and repairing of fault in the system, activation of MCP settings including making serviceable entire system complete all as specified and directed.
Rectification of defective fire alarm system, including servicing checking caliberation testing of existing fire alarm panel, connected wiring system, detectors and devices of make - Notifier at Administration block, CAIR complex by checking cable continuity, checking and repairing of fault in the system, activation of MCP settings including making serviceable entire system complete all as specified and directed.
Rectification of defective fire alarm system, including servicing checking caliberation testing of existing fire alarm panel, connected wiring system, detectors and devices of make - Notifier at System block, CAIR complex by checking cable continuity, checking and repairing of fault in the system, activation of MCP settings including making serviceable entire system complete all as specified and directed. NOTE FOR ITEM NOS 65 TO 71 :- (i) The tenderer shall be solely responsible for making the fire alarm system functional and his quoted rates shall deemed to include for manpower and spares other than that mentioned here-in-after as "Supply only". MES will not pay nothing extra in this regards. (ii) The firm is responsible for making good false ceiling of any type distrubed during rectification / fixing of spares etc and the cost for the same is inclusive in the quoted rate complete all as directed by Engineer-in-charge. (iii) Note : The job can be paid maximum of four times in the contract period with an interval of Three months periodcity.
Checking of water sprinkle fire fighting system infrastructure complete, rectifications of water leakages in the pipe lines, servicing all controls, testing of pressure of water in the lines and near all sprinkles properly and replacement of sprinklers / bulbs, setting of temperature of sprinklers as per existing on the site, tightening of all nuts, bolts and washers, testing system operation in all respects complete all as specified and directed. NOTE : (i) All Spares inclusive in the quoted rate as per site requirements (ii) The firm is responsible for making good false ceiling of any type distrubed during rectification / fixing of spares etc and the cost for the same is inclusive in the quoted rate complete all as directed by Engineer-in-charge. (iii) Note : The job can be paid maximum of twice in the contract period with an interval of Six months periodcity.
Supply Install testing and commissioning of Intelligent Addressable Networkable 2 Loop mocro processor based Fire Alarm Control Panel able to connect 250 devices ( Detector or Module) per loop in any combination and have sutable number of loop in the panel with 20% spare address for Detectors in Each & every loop. Should have Min 854 Char LCD multi-line QVGA LCD display complete with inbuilt additional Seven customized Programmable function switch for direct activation of any device or control along with Three programmable LED's. indication. Inbuilt min three Notification Appliance circuit ( NAC) for hooters. ( UL, ULC listed & CSFM, MEA, FM approved ) complete all as specified and directed. Make: Notifier, NFS 640 or techno commercially equivalent model in RAVEL /SIEMENS/APOLLO as approved by GE.
Supply and installation of single loop card that can support around 159 detector and 159 devices all as per Cat No . SLC of Notifier make or it's techno commercially equivalent model in other makes complete all as specified and as directed.
Supply and Installation of microprocessor controlled based 4 Zone Fire alarm Panel suitable for site requirements in replacement complete all as specified and directed.
Supply and Installation of SMF Lead acid batteries 12 V, 7 Ah for Fire alarm Panel suitable for site requirements in replacement complete all as specified and directed.
Supply installation testing of Photoelectric smoke detector or smoke detectors of any type with Junction boxes as per site requirements in replacement make/ model complete all as specified and directed.
Supply and Installation of Heat Detector with Junction boxes as per site requirements in replacement complete all as specified and directed.
Supply and Installation of Manual call point with Junction boxes as per site requirements in replacement complete all as specified and directed.
Supply, Laying PVC copper cable FR 2 x 1.5 Sq mm armoured cable on surface of wall / ceiling of any type in replacement complete all as specified and directed. Note : PVC conduit as applicable shall be measured and paid separately under relevent item.
Supply, Laying PVC copper cable FR 2 x 1.5 Sq mm cable on surface of wall / ceiling or drawn through existing PVC conduit of any type in replacement complete all as specified and directed. Note : PVC conduit as applicable shall be measured and paid separately under relevent item.
Supply and Laying of PVC conduit 19 mm dia / Casing Capping/ Flexible conduits with Accessories as per site requirements in replacement complete all as specified and directed.
Supply fixing testing Conventional Hooter, Wall mountable, 24 V DC Operation, Piezo Electric Type, Operating Voltage 24V DC, Operating Current 40ma as per existing make and model of the site or equivalent specification model of any ISI marked complete for site requirements in replacement complete all as specified and directed.
Comprehensive Maintenance of MS Motorised Sliding gate (02 Nos) daily cleaning checking and carry out necessary maint as per site requirements for motor, gear box, top guider of gate guide roller assembly, drive system, compressing motor open box, rack pinion, manual over side mechanism base plate, control system /panel with actuator ,safety system control panel complete all as specified and directed. Note : The quoted cost for Comprehensive maint includes all spares and repairs, rewinding works as applicable for proper functioning of gates during entire currency period of contract.
Comprehensive Maintenance of MS Motorised rolling shutter daily cleaning checking and carry out necessary maint as per site requirements for motor, gear box, top guider of gate guide roller assembly, drive system, compressing motor open box, rack pinion, manual over side mechanism base plate, control system /panel with actuator ,safety system control panel complete all as specified and directed. Note : The quoted cost for Comprehensive maint includes all spares and repairs, rewinding works as applicable for proper functioning og gates during entire currency period of contract.
Taking down unserviceable DCP type portable fire extinguiser 5 kg ISI markrd from the existing locations and Supply and fix new DCP 5 Kg fire extinguisher with clamp for ABC class of fire etc with poper fixing arrangements at required installtions complete all as specified and directed.
Taking down unserviceable DCP type portable fire extinguiser 3 kg ISI markrd from the existing locations and Supply and fix new DCP 3 Kg fire extinguisher with clamp for ABC class of fire etc with poper fixing arrangements at required installtions complete all as specified and directed.
Auromirra Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .