Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.5 LAccepted-AOC N A | 1 | Accepted-AOC ok | |
| 2 | 2₹16.6 L+₹9,024.94 (0.55%)Rejected-Finance NA VPO KHARIA HISAR 125001 | HISAR | HARYANA | 125001 | 2 | Rejected-Finance l2 | |
| 3 | 3₹17.6 L+₹1.1 L (6.69%)Rejected-Finance DARBA KALAN WARD NO 9 GIGORANI DISTT SIRSA C O SIRSA ROAD NATHUSARI CHOPTA WARD NO 9 GIGORANI DISTT SIRSA C O SIRSA ROAD NATHUSARI CHOPTA 125110 | SIRSA | HARYANA | 125110 | 3 | Rejected-Finance l3 |
Tender Value
₹15.0 L
EMD Value
₹29,980
Closing Date
14 Sept 2023, 2:00 pmClosed
Pardeep Kalyan
Municipal Corporation Panipat
Procurment and installation of 2 new 16 mtr high mast sports tower lights having 500 Watt LED sport flood lights install on it in Shivaji Stadium Modal Town MC Panipat(Only for L/C Society)
2023_HRY_308110_1
2023DCAC401A 03E1 4ED6 B5CE C25737D11779286ULB
Open Tender
Civil Works
Works
160 days
Panipat
2 documents required · 2 mandatory
₹1,000
₹29,980
Yes
17 Nov 2023
1 Sept 2023
14 Sept 2023
1 Sept 2023
14 Sept 2023
1 Sept 2023
Amount
`Specification of Sport LED Flood Luminaire: LED Flood Lights (With 5 years warranty period): Energy efficient LED Sports Floodlight luminaires for Sports applications. Innovative LED lighting system solution that supports the latest lighting standards. LED floodlight luminaires to offer outstanding light quality, effective thermal management, and long lifetime. Floodlight system delivers maximum light output while ensuring effective thermal management to maximize lifetime and minimize maintenance costs Luminaires to offer Maximumdesignflexibility and a high level oflighting quality. LED Sports Flood Light luminaires shall be one single unit with integral driver unit, specially designed Optical System. • System Power consumption 500W • Luminaire to be with SMD High Power LEDs and COB type LED system is not acceptable. • SMD LED - Individual LED =3W- =5W (at design operating current and Tj – 85deg C.). • CRI =70 • CCT 5700K plus 350K • LED Must be of Lumileds, Osram and Cree Makes only. • LED should be tested for min 13000hrs @1050mA Current. • Estimated Life span of Fixture = 78,000 hours, Case Temperature of 105 deg C w.r.t Lumen maintenance of 70%. • Limits of the harmonic current to be as per IS: 16103 (Part 1): 2012 and IEC 61000-3-2 with Total Harmonic Distortion =7 % for the complete fixture. • Note: COB type LED chip is not acceptable. MultiChip LED is notacceptable. • System power 500W • Housing – One single unit body shall be corrosion resistant High Pressure Die Cast Housing made from ADC12 aluminum alloy with very low copper (Cu) content with Integrated optics and anti Dust Exposed Lens (Transparent and weather resistant grade polycarbonate material for optical lenses. It can withstand extreme weather conditions and have strong resistance UV and yellowing). • Mounting -Via U Shaped Bracket with Aiming Scale Angle, Universal Installation. • The Floodlightfixture shall beminimumIP66 (no glue)suitable for allweather outdoor application with an impact resistance of IK 08. • Optics – Luminaire should have polycarbonate lens for dedicated rotational/symmetrical optic with reduced glare properties. Various optics should be available to meet the design criteria and optimize the design for an efficient system. (symmetrical wide beam, symmetrical narrow beam and asymmetric beam optics options should be available for optimum/efficient design ) with zero ULOR. • These flood lights should be suitable for operating temperature range of -40°C up to plus 40°C. • The luminaire should have a nominal Correlated Color Temp. (CCT): Cool White (CW) CCT - 5700 K plus 350K (tolerances as per ANSI C78.377-2008) • Min System Lumen output = 60,000 lm. at ambient temp of 35 deg C. Min Efficacy of Luminaire at Optical level of System =130lm / watt. Lumen Output parameters of luminaires are required at 35deg C ambient temp. • Colour Rendering Index Min: 70, SDCM (MacAdam ellipse) =5 • Operating voltage range: 120-270VAC / 50-60 Hz with Additional Protections 440V (Phase to Phase Protection for 8 Hrs. and Low- High cut @ 325±15V and auto Restart. • Protection from Voltage surges (SPD) - An appropriate surge protection arrangement, at each Flood Light to be provided, to protect the Flood Light from switching surges, which are expected / prevalent in Flood Light supply networks in India. Inbuilt internal surge protection of min 4KV and External Surge protection (SPD) of minimum 20KV. • The Driver unit should have a power factor is =0.95 at full power. LED life classshould be 78000 hours while the Driver lifetime should be 50000 hours at operation temperature range and driver case temperature must be =80°C. • The Drivershall be filled potted epoxy encapsulated. LED Drivershall have efficiency )85%. • Luminaire shall be in a single Piece and Modular type is not acceptable. • BIS certificate is must for Luminaire and driver both. • Same make is must for Luminaire and driver both. Make: Crompton/Phillips/Bajaj/Havells`
`SITC of DIN Type Astronomical Digital Time Switch with 1 CO: Astronomical programmable every 1 minute, backup of 6 years , 28 memory locations, currently capacity 16 Amp, with one changover, total 28 programs Make: Indo Asian/Havells/Crompton/Halonix
Supply of PVC/XLPE INSULATED (HEAVY DUTY) ELECTRICAL CABLES FOR WORKING VOLTAGE UPTO AND INCLUDING 1100 VOLTS TO IS:1554 (PART-I) 1988/7098 (Part – I) WTH ALUMINIUM CONDUCTOR – ISI MARKED POWER CABLE- ALUMINIUM CONDUCTOR 25 Sq mm 4 core armoured LT aluminium cable Make: Grandlay/Havells/POLYCAB`
PVC/XLPE INSULATED (HEAVY DUTY) ELECTRICAL CABLES FOR WORKING VOLTAGE UPTO UPTO AND INCLUDING 1100 VOLTS TO IS : 1554 (PART-I) 1988 / 7098 (Part-I)1988 WITH COPPER CONDUCTOR – ISI MARKED` `Supply and erection of 2.5 sq. mm 2 core ISI marked, FRLS PVC insulated, cable Make: Havells/POLYCAB/Grandlay `
`Load Extension of already installed electrical meter as per the site requirement and as per the standards and specifications of Electricity Board. Note: Actual payment of the mater will be done as per the receipt recevied from Electricity Board `
S and E of 32 Amp Power Contactor Make: LandT/CandS/Siemens
`Design, fabricate and supply at site 16 mtr High mast pole (excluding the Ht. Of head frame ) with head frame of suitable size for installing 16 nos. of 500 watt sport flood light on it as per the design with either lantern carriage or caged ladder and platform with railing for maintenance of the Flood Lights along with all its Accessories, nut bolts etc. conforming to the Specification of the contract. High mast shall be of continuously tapered, polygonal cross section, minimum 8 sided, presenting a good and pleasing appreance, assured performance, and reliable service. The height of mast pole shall be at 16 m, with minimum across Flat dimensions of 200mm at the top. The plate thickness shall be 5 mm for bottom and 4 mm for top section and suitable for wind velocity as per IS 875 part 3. The 16 meter high mast shall be delivered either in two or maximum three two sections, and shall be joined together by slip stressed-fit metod at site. The minimum overlap distance shall be 1.5 times the diameter at penetration entire fabricated mast shall be hot dip-galvanized, internally and externally as per BS EN ISO 1461 having a uniform thickness of 65 microns. It shall also include accessories for high mast including head frame arrangement suitable for mounting 15 liminaries LED FLOOD LIGHT symmetrically. Suitable head frame as per the design for the required illumination across the designed illumination beam to be designed, fabricated and fixed over the pole. The tilt angle and curvature of the head frame to be designed so as to get the class II illumination of cricket ground as per SP 72 9 Refer including supply of foundation bolts manufactured from special steel min. 6.8 grade along with nuts, washers, anchor plate and templates (1 fitting per mast is necessary) as per specification and direction of the Engineer-in- charge. Bidder are requested to Quote for the Foundation bolts, Templates etc. separately in the specified row below. Providing Mild steel Templates suitable and matching with the PCD of the high nast pole fabricated with minimum 50*5 mm plate with Red oxide/ Zinc chromate antirust coating. Holes for the Bolts to be drilled/punched and grined properly so that even surface may be obtained for proper leveling of the bolts. Providing and fixing of Avitation obstruction light. Providing and fixing minimum 28 mm diameter minimum 850 mm long having minimum 6.8 grade bolts having anchor plate 8mm thick along with minimum 2 nos. galvanized nuts per bolt. The exposed portion of the bolts and nuts washers shall be hot dip galvanized and the embedded portion can be coated with anti- rust coating such as Zinc chromate/ red oxide. Providing and fixing timer switch for these mast lights. Make: Phillips/Bajaj/Vipin ST Poles/CROMPTON`
Bidder Name
Amount
The Swachh Haryana Co op L/c multipurpose Society ltd(GSTN-06AAGAT8251P1ZT)
THE ROHINI COOP L&C SOCIETY LTD.(GSTN-NA)
The Darba Kalan Shila Coop L/C Society Ltd.(GSTN-NA)
The Swachh Haryana Co op L/c multipurpose Society ltd
The Darba Kalan Shila Coop L/C Society Ltd.
The Swachh Haryana Co op L/c multipurpose Society ltd
The Darba Kalan Shila Coop L/C Society Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .