Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.9 L+₹1.2 L (4.26%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹30.8 L+₹2.1 L (7.31%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹31.0 L+₹2.3 L (7.94%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹33.5 L+₹4.8 L (16.6%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹49.9 L
EMD Value
₹1 L
Closing Date
25 Oct 2022, 6:00 pmClosed
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Repair/maintenance to street lights, LT panels, LT UG cable/ LT OH lines and other allied works at Varanasi Cantt.
2022_MES_554447_1
8603/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Varanasi
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹1 L
Yes
31 Jan 2023
26 Sept 2022
27 Oct 2022
26 Sept 2022
25 Oct 2022
11 Oct 2022
26 Sept 2022 - 3 Oct 2022
Amount
Taking down existing non functional security/ street light fittings from pole/ wall/ pipe of any type of LED fitting of any wattage for repairing by replacing of the street light including replacement/ unserviceable accessories like SPD, LED Driver etc & refixing the same with & including connecting cable of 3 core PVC sheathed Aluminium conductor not less than 4 Sqmm from light fitting to cable looping box & tightening of brackets, clamp by nut, bolts and washer including testing, complete all as specified and directed. NOTE : (i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under respective items of this schedule. (ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items. (iii) Any type of Ladder or arrangement for dismantling of light from pole/ hanger pole shall be arranged by the contractor.
Service cable un-armoured of size 4 sqmm 2 core, 1100 volts grade, heavy duty cable with PVC insulated solid aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old/ unserviceble service wire, complete all as specified and directed.
Service cable un-armoured of size 6 sqmm 2 core, 1100 volts grade, heavy duty cable with PVC insulated solid aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old/ unserviceble service wire, complete all as specified and directed.
Service cable un-armoured of size 10 sqmm 2 core, 1100 volts grade, heavy duty cable with PVC insulated solid aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old/ unserviceble service wire, complete all as specified and directed.
Surge protection device 10 KV, suitable for LED street lights of capacity 45 watt to 250 watts, single phase, 230 volt, 50 Hz, AC supply, complete all as specified and directed.
LED street light/ Flood light fitting driver/ choke 36/40/45/60 watts, 240 volts AC 50 Hz electronic type, complete all as specified and directed. Make :- Havells Cat Part No-LSSCRX2208 Or equivalent in Bajaj
LED light fitting driver/ choke 70/75 watts, 240 volts AC 50 Hz electronic type, complete all as specified and directed. Make - Philips cat Part No-X075C070V107FNY1CO/ Crompton & Greaves/ Havells/ Bajaj
LED street light/Flood light fitting driver/ choke 90 watts, 240 volts AC 50 Hz electronic type, complete all as specified and directed. Make - Havells Cat Part- NI2PRIOPBCP1SN040/065V2100_02 / Bajaj/ Crompton & Greaves / Philips
LED street light driver/ choke 25/30 watts, 240 volts AC 50 Hz electronic type, complete all as specified and directed. Make - Crompton & Greaves/ Philips / Havells / Bajaj
LED street light luminaires 25 watt with pressure die cast aluminium housing with heat resistant toughned glass and IP66 protection complete including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Crompton Greaves cat No- LSTO-25- CDL, Havells cat part no LHETAXU7UN6W024, Orient cat no- LSFS-025-CF-PC
LED street light luminaires 35 watt with pressure die cast aluminium housing with heat resistant toughned glass and IP66 protection complete including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Crompton Greaves cat No- LSTO-35- CDL Or Equivalent make in Havells/Bajaj
LED street light luminaires 60 watt with pressure die cast aluminium housing with heat resistant toughned glass and IP66 protection complete including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Crompton Greaves cat No- LSTO-60- CDL, Havells cat part no - LHETAXU7PN6J060
LED street light luminaires 90 watt with pressure aluminium -die- cast powder coating housing & frame with heat resistant,high efficiency toughned glass with EPDM gasket for IP66 protection complete assembly with LED ,driver& accessories pre-wiredup to terminal block including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Crompton Greaves cat No- LSTO-90- CDL, Havells cat part- LHETAXU7IN6J090
GI bracket for security light & street light fittings fabricated with GI tubing 40 mm dia 'medium grade' 1.2 m long including and bending to angle of 120 degree, fixed in repair, complete all as specified and directed.
Mild steel clamp fabricated with mild steel flat iron 50 mm x 6 mm including nut and bolts with washer suitable for fixing of GI bracket on PCC/ steel poles, fixed in repair, complete all as specified and directed.
Hot press moulded PVC junction box of size 230mm x 170 mm x 105 mm with 200A TPN Aluminium bus bars mounted/ fixed on porcelain insulator shock and rust proof, cable entry from bottom and other sides,100% weatherproof, with pole mounting arrangement temper proof, fire retardant class FV-0 as per IS 11731 part -II or V-O as per UL-94 including flat iron clamp of size 25 x 3 mm with nut and bolt, fixed in repair, complete all as specified and directed. Make :- Sintex/ Naithani plastic works/ Supreme industries
Electronic street light Astronomical control timer switch, operating automatic/ mannually with sheet metal encloser box wall/pole mounting type including heavy duty clamp made out of mild steel sheet 3.15 mm thick duly painted with two coat of synthetic enameled paint over a coat of red oxide primer of capacity 6 KW,Conforms to IS/IEC 60947-4-1, 3 phase, 415/230 volts, 50 Hz, ISI marked suitable to accommodate the following including taking down existing feeder box :- (a) Three phase control switch MCB TPN 40A 10 KA - 01 No (Incoming) (b) Auto/ Manual control switch (c) Heavy duty 3 Phase Contactor ML-3 with auxiliary contact - 01 No (d) Sun light sensor cat eye type complete to operate before sun rise & after sun set (d) Astronomical Timer - 01 No. Make - Havells cat Part No - IHXTS0306A or equivalent make in L&T, Legrand
Energy saving LED garden light fitting, decorative, bollard of capacity 10 watt with opal diffuser & Aluminium reflector complete with all accessories and fixing arrangement on PCC block of size 45mm X 45 mm alog with fixing nuts, bolts and PVC insulated aluminium conductor, stranded type of size 4.0 sqmm, 2 -core including taking down old/unserviceble garden light fittings any type and wattage, complete all as specified and directed. Make - Orient Step Bollard Cat part NO.LLSBL-10-W Or techno commercial equivalent make in Havells
Steel tubular pole swaged type 410-SP 31(9.0m long pole) as per IS:2713 (part I to III) 1980 complete with cast iron base plate, pole cap, mild steel bolt, nuts and screws complete including dismantling of exsiting pole all as specified including consisting of following works:- (a) Excavation in trenches not exceeding 1.5 mtr wide & 1.57 mtr deep for pole foundation & getting out in soft/loose soil, returning filling in the excavated soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs. (b) PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) in foundation 900mm x 600mm cross section and planting depth 1.5 mtr for concrete encasing the pole upto ground level. (c) PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/ collar above GL 500mm high and 450mm dia. (d) Painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block. (e) Writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed. NOTE : Manufacture's test certificate will be produced before execution work. MAKE : National tubing Co Kanpur or BCW Kanpur or M/s Sohan Lal & Sons or United Engineers, Kanpur.
Taking down existing non functional high mast/ semi high mast pole light any type/ wattage for repair including replacement of unserviceable spares/ accessories like ballast, starters, ignitors, lamps, service connection etc & errecting the same after cleaning & greasing of SWR rope in position after complete repair and testing all as specified and directed. NOTE : (i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under respective items of this schedule. (ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items. (iii) Any type of Ladder or arrangement for dismantling of light from pole/hanger/high mast pole shall be arranged by the contractor.
Rewinding of motor with super enameled copper wire of high mast light any type (gauge/weight of copper coils shall be same as per existing dismantled motor strata), including varnishing, complete all as specified and directed. Notes :-(a) Removing the defective motor & rectifying after repair including removing defective parts, burnt winding carefully, cleaning & re-assembling the motor after repair/ servicing including oiling, greasing.
PVC insulated & FR PVC round stranded sheathed conductor copper multi core round ( flexible) industrial cable 1100 volt with bright concealed electrolytic bare copper conductor for voltage 1100 volts grade of size 16 sqmm, 4 core confirming to IS-694-1990 including taking down old/unserviceble cable any type from semi high/high mast poles of any height and connecting, complete all as specified and directed.
PVC insulated & FR PVC round stranded sheathed conductor copper multi core round ( flexible) industrial cable 1100 volt with bright concealed electrolytic bare copper conductor for voltage 1100 volts grade of size 10 sqmm, 4 core confirming to IS-694-1990 including taking down old/unserviceble cable any type from semi high/high mast poles of any height and connecting, complete all as specified and directed.
LED integral flood light luminaires 170 watt in powder coated with aluminium die cast housing and frame, high efficiency, long life LEDs, loop in loop out connector, 10 A G.F.P for each wiring heat resistant toughned lear glass cover and IP 66 protection complete assembly with LEDs,driver and accessaries pre wired up to terminal block in control gear compartment including connection on pole or building including taking down of old /unserviceble HPSV/MH street light fitting any type & wattage, complete all as specified and directed. Make- Wipro cat No-LR18-971-XX-57-XX / Havells cat part- LHEPCZU7P46J150 / C&S-LTESS10X2.5HPLED
LED integral flood light luminaires 120 watt in powder coated with aluminium die cast housing and frame,high efficiency,long life LEDs,loop in loop out connector, 10 A G.F.P for each wiring heat resistant toughned lear glass cover and IP 66 protection completeassembly with LEDs, driver and accessaries pre wired up to terminal block in control gear compartment including connection on pole or building including taking down of old /unserviceble street light fitting, complete all as specified and directed. Make- Wipro cat No-LR18-971-XX-57-XX / Havells cat part -LHEPCZU7P46J120
LED integral flood light luminaires 210 watt in powder coated with aluminium die cast housing and frame, high efficiency, long life LEDs, loop in loop out connector, 10 A G.F.P for each wiring heat resistant toughned glass in the front with unique flood optics to ensure uniform distribution and IP 66 protection complete assembly with LEDs, driver and accessories pre wired up to terminal block including connection on pole including taking down of old /unserviceble light fitting, complete all as specified and directed. Make- Orient cat No-LFAP-200-C or any other techno-commercially equivalent make in Havells / Phillps
Restringing of existing overhead line ACSR conductor and earthwire of any size including opening from insulators, tightening upto permissiable sag, binding properly and refixing of cradles with safety precaution complete all as specified & directed. Note: Each row/ span of ACSR conductor and earth wire to be measured separately.
Under water luminiaries 7 watt LED light for connecting under water lighting purpose of fountain, Corrosion resistant, Nickel plated brass housing, water proof with flanges of top coloured glass with rubber gasket on both sides , mounted in brass frame with all accessiories and LED complete all as specified and directed.. Make - C&S. model- LTUW7x1HPLED / C&G-CGDMX512 or any other techno-commercially equivalent make in Havells / Phillps
Loop type porcelain, vitreous, white, brown or green insulator inluding one galvanised strip 31 x 3 mm, 16 mm dia, galvanised iron nuts, bolts & washers and 65 mm height & 90 mm dia suitable for 1100 volts grade including taking down old/ unserviceble insulators, complete all as specified and directed. Make - Jaipuria Brothers or equivalent BHEL or Jayshree Insulators
Servicing of Solar street light at different existing locations including cleaning thoroughly panel, battery box, light fitting repairing including replacement of defective components, painting of pole with aluminium paint, cleaning battery topping with acid, charging / filledup of distilled water upto required level, applying of petrolium jelly on battery terminal and testing the system complete all as specified & directed. Note : Spares required shall be measured seperately.
PCB for solar street light 15watt as per existing make & model at site, fixed in replacement, complete all as specified and directed.
Solar DC street light, 15 Watt, fixed in replacement, complete all as specified and directed. Make : Bajaj/ Philips/ Havells.
Solar panel of size 600 mm x 1200 mm suitable for 80 watt, fixed in replacement, complete all as specified and directed.
Initial charged solar battery capacity 12 volts 100 Ah for solar light, complete all as specified and directed. Make : Luminus Cat Part No.LPTT12100H or equivalent make in Amron/ Exide.
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out including filling bottom surface to required level or slope for laying of pipes/ cables, complete all as specified and directed.
Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft soil, complete all as specified and directed.
Removing excavated surplus soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Sand cushioning with clean dry local sand [unwashed] for protection of under ground cable (8 cm before laying and 15 cm after laying of the cable) in trenches and consolidated complete all as specified & directed. Note : Punned thickness 18 cm only shall be considered for payment.
Sub class ‘B’ common burnt bricks old size, laid dry, flat with width equal to length of bricks as cover / laid over the cable to protection of under ground cable complete all as specified & directed.
Bore hole for passing cable through / insertion of 80/ 50mm dia GI pipe under PCC road/ taxi track/ runway/ hard standing upto the depth 450mm to 1200 mm complete all as specified and directed. NOTES :- (i) Cost of equipments, tools & plants, material required for boring shall be deemed to be included in unit quoted rates above. (ii) GI pipe 80/ 50 mm dia shall be measured and paid separetely.
Galvanised iron water tubing 32 mm bore "light grade" ISI marked including fittings such as bends, tees, sockets etc fixed on walls / pole or laid in trenches under road crossing including taking down old existing pipe complete all as specified & directed. Note : Excavation, earth work, sand cushioning & protection work shall be measured & paid separately.
Galvanised iron water tubing 50 mm bore "light grade" ISI marked including fittings such as bends, tees, sockets etc fixed on walls / pole or laid in trenches under road crossing including taking down old existing pipe complete all as specified & directed. Note : Excavation, earth work, sand cushioning & protection work shall be measured & paid separately.
Galvanised iron water tubing 80 mm bore "light grade" ISI marked including fittings such as bends, tees, sockets etc fixed on walls / pole or laid in trenches under road crossing including taking down old existing pipe complete all as specified & directed. Note : Excavation, earth work, sand cushioning & protection work shall be measured & paid separately.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 4 core 16 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 4 core 10 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 2 core 10 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 2 core 6 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 3.5 core 400 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 3.5 core 120 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 3.5 core 95 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 3.5 core 70 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 3.5 core 50 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 3.5 core 35 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Supply, laying and testing XLPE cable insulated, screened, PVC beded galvanised steel strip or wire armoured, electric power cable (Heavy Duty) 1100 Volt grade with stranded aluminium conductor of 3.5 core 25 sq.mm, including taking down existing old/ unserviceable cable, complete all as specified and directed. NOTE:- Excavation, earth work, sand cushioning and brick protection work shall be measured and paid separately under respective items of this Schedule.
Cross arms bracing, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts, in any shape or size as indicated or directed and inclusive two coats of aliminium paint over a coat of primer including taking down of exsiting cross arms, complete all as specified and directed.
Preparation of steel surfaces of indoor/ outdoor electrical panel of any size/type and removing dust, dirt by cleaning/ scrubbing inside outside as required, welding/ fixing and providing fresh hinges/ screw/ nut bolts as required and fixing the panel door including painting the external surfaces with one coat of synthetic enamel paint without disturbing the existing fittings and fixture,changing of unserviceable voltmeter, ammeter, indicator lamp, proper taping to incomming outgoing LT UG conductor with flexible tape and insulation tape including marking and writing letter such as SM No. capacity etc, with safety precaution, complete all as specified & directed.
Rubber insulating matting as per ISI Mark (size 1m x 2m x19 mm) for voltage upto 11 KV including taking down old/ unserviceble insulating matting, complete all as specified and directed.
Restringing of existing overhead line ACSR conductor and earthwire of any size including opening from insulators, tightening upto permissiable sag, binding properly and refixing of cradles with safety precaution, complete all as specified and directed. Note:- All rows of ACSR conductors and earth wire in each span to be measured as one span and approx length of each span is 30-35 mtr.
Preparation of 9.00 mtr long steel tubular pole including cross arms, clamps of any length and shape for overhead line/street light and painting with two coat of aluminium paint of Make- Nerolac/ Asian Paint including marking pole number in a 15cm dia yellow circle and zebra painting with three black & two yellow bends of 10 cm width by fluorescent paint, from coping of pole to 1.5m height on pole including applying one coat of white wash on coping with safety precaution complete all as specified & directed. Note - (i) All the instruments and T&P required for the above job shall be arranged by the contractor at site including ladder, safety harness and cost of the above deemed to be included in the rates. (ii) Contractor should be provide two labours for joining and dismantling of cable at both the end and excavation above the faulty cable if required.
Sheet metal enclosure for VTPN DB double door 415 Volt with 200 amp rated bus bar complete with suitable for 1 x 63Amp MCCB as incomer and MCB SPN as outgoing connection through proper size of lugs and cable glands including taking down existing MCB DBs, complete all as specified and directed.
MCCB 63 Amp,4 pole ,415 Volt ISI marked conforming to 'B" curve, breaking capacity 16 KA, complete all as specified and directed.
ACB, 4 pole, 415 volts, 630Amps, with thermal megnetic release (Manual Fixed type) breaking capacity 50 KA, including taking down old/ unserviceble ACB/ MCCB, complete all as specified and directed.
MCCB, 4 pole, 415 volts, 400 Amps, breaking capacity 50 KA, with thermal magnetic release adjustable type including taking down old/ unserviceble MCCB, complete all as specified and directed.
MCCB , 4 pole, 415 volts, 250 Amps, breaking capacity 35KA/ 36 KA, with thermal magnetic release adjustable type including taking down old/ unserviceble MCCB complete all as specified and directed.
MCCB , 4 pole, 415 volts, 200 Amps, breaking capacity 35KA/ 36 KA, with thermal magnetic release adjustable type including taking down old/ unserviceble MCCB, complete all as specified and directed.
MCCB , 4 pole, 415 volts, 160 Amps, breaking capacity 35KA/36 KA, with thermal magnetic release adjustable type including taking down old/ unserviceble MCCB, complete all as specified and directed.
MCCB , 3 pole, 415 volts, 100 Amps, breaking capacity 35 KA/36 KA, with thermal magnetic release adjustable type including taking down old/ unserviceble MCCB, complete all as specified and directed.
MCCB , 3 pole, 415 volts, 63 Amps, breaking capacity 25KA, with thermal magnetic release adjustable type including taking out existing old/ unserviceble MCCB, complete all as specified and directed. .
MCB TPN, 4 pole, 415 volts, 63 Amps,'B' curve 10 KA, including taking out existing old/ unserviceble MCB, complete all as specified and directed.
Bus bar box of sheet metal 3 mm thick powder coated, having 4 Nos. aluminium bus bar of rating 200 Amp mounted on insulator including 01 No. of MCCB 4 pole 63 Amp 415 volts with thermal magnetic release as incomer, breaking capacity 25 KA inside the box and suitable fixing arrangement like flat iron clamp of size 25mm x 3mm with hinged cover & locking arrangement including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron of size 40 X 40 X 6 mm welded on all the four corner embedded in PCC 1:2:4 using 20 mm graded stone aggregate complete duly painted with two coat of synthetic enamel paint over a coat of red oxide primer fixed in repair outdoor type, complete all as specified and directed.
Change over switches panel mounted off load type in open execution, front operated rotary handle of 200 Amp rating, 4 pole, 415 Volt iincluding taking down old/ unserviceable change over switch, complete all as specified and directed.
Change over switch panel mounted off load type in open execution, front handle operated of 100 Amp rating, 4 pole, 415 Volt including taking down old/ unserviceable change over switch, complete all as specified and directed.
Onload change over switch in open execution, side handle operated of 100 Amp rating, 4 pole, 415 Volt including taking down old/ unserviceable change over switch complete all as specified and directed. Make-Havells cat part IHBFFE00100 or any other techno-commercially make in Crompton/ L&T / C&S / ABB
Onload change over switch in open execution, side handle operated of 63 Amp rating, 4 pole, 415 Volt including taking down old/ unserviceable change over switch complete all as specified and directed. Make-Havells cat part IHBFFE0063 or any other techno-commercially make in Crompton/ L&T / C&S / ABB
Hiring Fault locator Megger machine for locating fault in HT/LT UG cable of any size, complete all as specified and directed NOTE : (i) All the instruments and T&P required for the above job shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (ii) Contractor should provide two labours for Joining and dismantling of cable at both the end and excavation above the faulty cable if required.
Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable end termination heat shrink type joint complete with jointing material & accessories for 3.5 core XLPE cable of size 25 sqmm to 50 sqmm insulated armoured aluminium cable including taking down old/unserveciable joint kit, complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable end termination head shrink type joint complete with jointing material & accessories for 3.5 core XLPE cable of size 70 sqmm to 120 sqmm insulated armoured aluminium cable including taking down old/unserveciable joint kit, complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable end termination head shrink type joint complete with jointing material & accessories for 3.5 core XLPE cable of size size 150 sqmm to 185 sqmm insulated armoured aluminium cable including taking down old/unserveciable joint kit complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 1100 volt grade cable for straight through cold shrink type joint complete with jointing material & accessories for 3.5 core XLPE cable of size 240 sqmm to 300 sqmm insulated armoured aluminium cable including taking down old/unserveciable joint kit, complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 1100 volt grade cable for straight through cold shrink type joint complete with jointing material & accessories for 3.5 core XLPE cable of size 400 sqmm to 500 sqmm insulated armoured aluminium cable including taking down old/unserveciable joint kit, complete all as specified and directed.
Supply,installation and testing of factory made, CPRI Approved cubical outdoor (Kiosk) type feeder pillar box 415 volt, 4 wire, AC 50 Hz, made out of 3.15 mm thick CRCA sheet, weather and vermin proof powder coating finish bothside (interior & exterior) for outdoor mounting with having degree of protection as per IP-56 complete factory lock two earth terminal suitable cable gland for all incoming and outgoing and removable neutral link, both Side openable double door Indicating light LED type RYB - 01 Set, Ammeter-01, Voltmeter-01, connecting strip/solid conductor brought out to cable chamber brass/ copper nut, bolts/ washer etc including grouting of feeder pillar box 60 cm above ground level including suitable size angle iron stand made up of 65 x 65 x 6 mm welded on all the four corner embedded in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) upto 30 cm including excavation and earth work complete with following asseccories :- (a) Aluminium insulated busbar high conductivity 525 Amp rated 3 phase including neutral bus bar complete - 01 No. Incoming :- (b) MCCB 4 -pole 350 Amp,415 Volt, breaking capacity 36 KA, 50 HZ with thermal magnetic release - 01 No. Outgoing :- (c) MCCB 4 - pole 160 Amps breaking capacity 25 KA, 50 HZ - 02 Nos. (d) MCCB 4 - pole 100 Amps breaking capacity 25 KA, 50 HZ - 04 Nos. (e) MCCB 4 - pole 63 Amps breaking capacity 25 KA, 50 HZ - 06 Nos.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 25 x 4mm galvanised earth strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel, including providing 32mm dia medium grade GI pipe for strip protection and 20mm dia pipe watering pipe duly fitted with wire mesh and funnel and filling charcoal dust and ordanary salt in alternate layers upto earth plate electrod all as shown in electrical plate No. 3 connected to earthing test point including necessary excavation all as specified or indicated including testing, complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25 x 4mm galvanised iron strip, complete all as specified and directed.
Loose filling spreading and leveling hard core 40mm graded corse aggregate, complete all as specified and directed.
Surface excavation in soft/loose soil not exceeding 30cm deep and averaging 15 cm and getting out including leveling the surface, complete all as specified and directed.
Loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 90mm x140mm, clearance of hole 25.5 mm, complete all as specified and directed.
Stay assembly complete with accessories including 20 mm dia stay rod and stay clamp all as shown in electrical plate No. 1, complete all as specified and directed. Note - Loop type insulator, stay clamps, excavation and concrete to be measured and paid separately.
Shackle type porcelain, vitreous, white, brown or green insulator inluding one galvanised strip 31 x 3mm, 12 mm dia, galvanised iron nuts, bolts & washers and 75 mm height & 90 mm dia suitable for 1100 volts grade including taking down old/unserviceble insulators, complete all as specified and directed.
Pin type porcelain, vitreous, white, brown or green insulator inluding including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 65 mm height & 100 mm dia suitable for 1100 volts grade including taking down old/unserviceble insulators, complete all as specified and directed.
Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15cm size, complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 cm x 20 cm size, complete all as specified and directed.
Taking electric shutdown and employing labour competent to climb on trees for maintenance and trimming of tree branches touching to overhaul bare electric condutor lines/ electric installation upto the clearance of 2 mtr all around and removing the garbage and deposting when and where directed, complete all as specified and directed. Note- Minimum 8 labours with proper safety kit and cuttings tools, ledder, electric saw/ generator set, wire rope etc shall be provided by the contractor and rates are deemed to be included the quoted rates.
PITAMBARI TRADERS
M/s A.K Construction
M/s A.KUMAR ELECTRICALS
M/S SS Tarders
Prem Singh
M/S SHIVA CONSTRUCTION
Avion Industries
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .