Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.7 LAccepted-AOC | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹81.6 L+₹15.7 L (23.9%)Rejected-Finance | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not fulfilled the NIT criteria | |
| 4 | Rejected-Technical | - | Rejected-Technical Not fulfilled the NIT criteria |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
1 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col N K Chaudhary
HQ 137 WKS ENGR PIN 914137 CO 99 APO
PROVISION OF BOREWELL AND CONSTRUCTION OF TWO NOs OF UG SUMPS OF 20000 GALLONS CAPACITY INCLUDING ALLIED SERVICES IN MIL STN AGARTALA
2023_MES_577620_2
8559/E8
Open Tender
Civil Works
Lump-sum
270 days
Agartala
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
AGE (I) Agartala
₹1.1 L
Yes
28 Jul 2023
3 May 2023
8 Jun 2023
3 May 2023
1 Jun 2023
18 May 2023
Amount
NOTE (Applicable for all parts/items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced schedule is given in tender documents
SCHEDULE "A" PART-II (EARTH WORK AND EXCAVATION ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -V (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' 5 ' signifies this fact only.
Material and labour for trail boring / drilling 'pilot bore' of dia suitable for lowering 150 mm dia MS pipe by any suitable method (by DTH-CUM-rotory or riverse rig method) to any depth below ground level in any type of strata / soil / rock with sand or loose boulder including disposal of materials obtained (soil, rock etc) from boring to distance not exceeding 150 meter with and including deploying required rig, machinery T&P, equipements etc with and including collection of Geological sample (drilling / Cutting) and to maintain drill time logbook complete all as specified and directed.
Boring/ Drilling bore of dia suitable for lowering 250 mm dia MS pipe, by any suitable method (by DTH-CUM-rotory or riverse rig method) up to a depth of 54 metre below ground level in any type of stata of soil/ loose boulders with sand including disposal of materials obtained (soil, boulders, etc) from boring to distance not exceeding 50 metre with & including deploying required rig, machinary, T & P , equipments etc with & including collection of Geological samples (drilling/cutting) & to maintain drill time logbook complete, all as specified.
Boring/ Drilling bore of dia suitable for lowering 200 mm dia MS pipe, by any suitable method (by DTH-CUM-rotory or riverse rig method) up to a depth of 144 metre below ground level to required depth (approx 150 mtr GL) in any type of stata of soil/ loose boulders with sand including disposal of materials obtained (soil, boulders, etc) from boring to distance not exceeding 50 metre with & including deploying required rig, machinary, T & P , equipments etc with & including collection of Geological samples (drilling/cutting) & to maintain drill time logbook complete, all as specified.
Material and Labour 200 mm bore (NB) MS Pipes (ERW) (slotted pipe) steel of standard length conforming to IS 4270, each length of pipe 6 mtr, both ends threaded with & including one long socket duly welded, wall thickness of pipe not less than 5.4 mm as per IS 3589 (1991), supply, lowering, fixing, welding at joints commissioning & testing.
Material and Labour 250 mm bore (NB) MS Pipes (ERW) (slotted pipe) steel of standard length confirming to IS 4270, each length of pipe 6 mtr, both ends threaded with & including one long socket duly welded, wall thickness of pipe not less than 5.4 mm, supply, lowering, fixing, welding at joints commissioning & testing.
Material and Labour for MS reducer socket 250 mm x 200 mm fabricated by mild steel sheet having 6.4 mm thickness of suitable length including fixing between mild steel ERW casing pipe of 250 mm and 200 mm bore by arc welding. complete all as specified and directed.
Material and Labour for Pea gravels of size 2 mm to 4mm dia of approved quality, packed arround the casing/ribbed pipe complete all as specified and directed.
Material and labour for holding clamp fabricated by mild steel plate of 20 mm thick of size 115 cm x 20 cm in two halves, having four numbers (two at each end) 24 mm x 150 mm bolts, nuts and washers suitable for clamping and holding of 250 mm bore mild steel ERW casing pipe all as specified and directed.
Material and labour for well Cap 3 mm thick MS Plate in two halves having a hole of 65/90 mm bore at centre to accommodate 50/80 mm dia GI pipe, 6 Sqmm submersible cable 3 core and suitable for fixing at top of PVC casing pipe including provision of material & labour for flat iron 50x6 mm MS nut bolts and washers 5/8”x 3”long for holding down resting the pump on supporting all as specified and directed.
Material and labour for casing shoe / bottom plug made of 200 mm bore, 6.4 mm thick mild steel ERW pipe of suitable length fixed at the bottom pipe by electric resistance welding complete all as specified and directed.
Yield test of bore hole after completion of development of bore well by pumping for 16 hrs to determine the safe pumping yield complete all as per IS and as directed including following:- (a) Collection of water samples from bore well and getting them tested chemical and bacteriological analysis from recognized institution by Govt. (b) Test on quality of water for drinking purposes.
Testing of Water samples for Bacteriological analysis, Physical & Chemical analysis from any Govt. approved / NABL accredited Laboratory and suitable suggestions/solutions for treatment of water for drinking purpose as approved . NOTE : The cost of collection of sterilized bottles, collection of water samples from water sources as directed by GE/Engr-In-Charge, depositing to laboratory and submitting the test results duly signed & certified to the Engr-In-Charge complete is deemed to be included in the unit quoted rates.
Material and Labour 80 mm bore GI column pipe heavy grade ISI marked in standard length of 3 metre each with heavy duty flange drilled holes for fixing arrangement units and suitable packing gaskets and lowering into well including supplying, lowering, fixing, commissioning & testing complete all as specified.
Submersible pump, set for tube well with submersible motor water lubricated, electric driven, 3 phase, 415 volts, 50z AC supply up to 47 mtr head and discharge 700 LPM (Approx) of suitable HP capacity complete, including lowering, commissioning and testing complete all as specified and as directed .
Supply and fixing electrically driven centrifugal pump set horizontal split case type with stainless steel shaft sleeve of brass & CI impeller suitable to discharge of water not less than upto 1000 LPM, upto 39 meter head, directly coupled with and including suitable size of 3 phase, TEFC sqirrel case induction motor 415 volts, 50z, AC supply rated capacity of suitable HP capacity complete, including standard coupling, coupling guard, company fabricated common MS channel base plate, foundation bolts including PCC foundation complete connecting to existing electric system including one No pressure gauge with 15 mm brass stop cock, supplying, installing, testing and commissioning & connecting to existing GI / CI suction and delivery line including connecting & jointing materials such as GI / CI reducers / expander flange ends, MS flange of required size testing commissioning complete all as specified and as directed.
Supply and fixing electrically driven centrifugal pump set horizontal split case type with stainless steel shaft sleeve of brass & CI impeller suitable to discharge of water 750 LPM, head range ( suction 21m, delivery- 30 Mtr), directly coupled with and including suitable size of 3 phase, TEFC sqirrel case induction motor 415 volts, 50z, AC supply rated capacity of suitable HP capacity complete, including standard coupling, coupling guard, company fabricated common MS channel base plate, foundation bolts including PCC foundation complete connecting to existing electric system including one No pressure gauge with 15 mm brass stop cock, supplying, installing, testing and commissioning & connecting to existing GI / CI suction and delivery line including connecting & jointing materials such as GI / CI reducers / expander flange ends, MS flange of required size testing commissioning complete all as specified and as directed.
Material & labour for construction of 230mm thick brick masonary valve chamber built in CM 1:6 of valve pit of size 900x900x900mm (internal size) with 100mm thick foundation using PCC 1:4:8 type D2 with 100mm offset,15mm thick plastering internally and 15cm below GL externally in CM 1:6, 3mm thick MS sheet cover ,double door welded to 50mmx50mmx6mm MS angle iron frame fixed with hold fasts in PCC 1:2:4 tyupe B1 coping 50mm thick, 20mmx6mm flat iron hinges with loocking arrangement including lock 65mm brass and keys, MS handies and applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces including excavation & earth work in any type of soil / rock and disposal of surplus soil to a distance not exceeding 50m complete all as specified and directed.
Material & labour for construction of 230mm thick brick masonary valve chamber built in CM 1:6 of valve pit of size 450x450x 700mm (internal size) with 100mm thick foundation using PCC 1:4:8 type D2 with 100mm offset,15mm thick plastering internally and 15cm below GL externally in CM 1:6, 3mm thick MS sheet cover ,double door welded to 50mmx50mmx6mm MS angle iron fram fixed with hold fasts in PCC 1:2:4 tyupe B1 coping 50mm thick, 20mmx6mm flat iron hinges with loocking arrangement including lock 65mm brass and keys, MS handies and applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces including excavation & earth work in any type of soil / rock and disposal of surplus soil to a distance not exceeding 50m complete all as specified and directed.
Supply & fixing of steel rope of size 8 mm dia 2 runs on both sides of submersible pump set with fully threaded nuts, bolts & washers for holding/supporting of submersible pump & motor of capacity 10 HP complete all as specified and directed .
Supply and laying submersible flat cable PVC insulated and PVC sheathed LT 1100 volt grade with copper conductor 4 sq mm 3 core complete all as specified and as directed.
Supply and laying submersible flat cable PVC insulated and PVC sheathed LT 1100 volt grade with copper conductor 6 sq mm 3 core complete all as specified and as directed.
Taking down CI pipe of 80 mm dia complete all as specified and directed.
Taking down GI pipe of 100 mm dia complete all as specified and directed.
Material & Labour for Disconnection of existing electrical cable for DG set, 30 KVA and taking down DG set including panel and shifting the same from pump house to E/M store yard complete all as directed.
Supply, installing, testing and commissioning of DG Set 40 KVA, four cylinder diesel engine, developing 56 BHP@ 1500 RPM, Engine will be water cooled by rail mounted, engine driven radiator of adequate capacity, with blower fan, fan guard, fan belts etc. The diesel engine shall be vertical, electric start, compression ignition, 4 stroke, designed to run continuously at 1500 RPM confirming to IS 10002, ISO-3046, BS 5514 standard with an overload capacity of 10 % for one hour in every 12 hrs of operation. Diesel Engine will comply with present CPCB norms. Diesel engine set as per IS 10002 and alternator as per IS-4722/BS EN 60034-1 with inbuilt electronic speed governor with micro processor based AMF control panel including necessary anti vibration pad and AMF panel as recommended by the manufacture the following specification as enumerated here-in-after upto item No. 5.33 here-in-after complete all as specified and as directed:- (a) The diesel engine comprising of following:- (i) MICRO/BOSCH fuel pump with Mechanical Governor (ii) Dry type air cleaner (iii) Residential silencer (iv) First fill of Lubricant oil (v) Lubricating oil filter (Replaceble elemant type) (vi) Fuel oil filter (Spin on type) (vii) Battery charging alternator.
b. GEN-SET CONTROLLER Following indication / LCD display should be available in the digital Gen set controller (i) Lubricating oil pressure (ii) Battery voltage (iii) Engine RPM (iv) Fuel level in the day tank (v) Engine running hours indication (vi) AC Current (vii) AC Voltage (viii) AC Frequency (ix) Unit generated indicator for the items as mentioned from (vi) to (ix) (x) Suitable CTs for displaying the electrical parameters c. Safety alarm required in the digital Genset Controller:- (i) High Engine temperature (ii) Low lubricating oil pressure (iii) Low radiator water level (iv) Low fuel level (v) Battery high voltage (vi) Under / Over speed safety trips requirred in the Digital Genset Controller d. Safety trips required in the digital Gen set controller:- (i) High engine temperature (ii) Low lubricating oil
(D) BASE FRAME Suitable to couple above Engine & Alternator made from steel sheet metal (E) Fuel TANK Capacity of the fuel tank should not beless then 12 Hrs continuous run with Inlet & Outlet arrangement, air vent & drain plug arrangement. (F) BATTERY 12 V 55 AH M/F barreries with connecting leads and terminals. Make : Exide/Amco/Power line. (G) TECHNICAL SPECIFICATION OF ACOUSTIC ENCLOSURE CONSTRUCTION Following are some technical features of Acoustic Enclosure:- 1. The enclosure is modular in construction. 2. Base frame is made of Sheet metal. 3. Durable industrial locking system is provided on doors 4. Doors are gasketed with high quality EDPN gasket. (H) CORROSION RESISTANCE:- To make the enclosure weather proof:- (i) All sheet metal parts/components are hot dipped in seven tanks process, pre- treated and passivity. (ii) Sheet metal components shall be painted pure polyster powder coated based in black colour. (iii) Base frame is epoxy coated. (iv) Specially designed Residential Silencer is provided.
(J) ACOUSTIC INSULATION: 1. Sound proofing of the enclosure done with quality Foam confirming to IS: 8183. 2. Acoustic form shall be fire retarded and fire resistant. 3. Attenuates are provided to control sound at entry and exit to and from the container. 4. Specially designed Residential Silencer is provided. 5, Hooks for lifting/Shifting. (K) VENTILATION AND AIR CIRCULATION: (i) Exhaust pipe is thoroughly insulated by covering it with glass wool and further gladded in Enclosure. (ii) Suitable slots/ventilators need to be provided in canopy for natural air circulation. (L) ELECTRICAL: (i) Neutral Body earthing points at the sides of enclosure are isolated through Dough Moulded compound. (ii) A light point with switch need to be provided inside the canopy. (M) SAFETIES: Emergency push button to stop the DG Set from outside, Lub oil level, Lub oil pressure, Fuel level indicator, Coolant level, Canopy temperature, High engine temperature.
Notes: (i) Design / Drawing / BOM of the DG set showing the dimension is to be obtained from the OEM / Authorised supplier and is to be got approved from GE before placing final order to the manufacturer. (ii) The cost of servicing including minor repairs / replacement such as topping up of coolant, engine / lubricating oil as well as lubricating filters including periodical checking of the complete DG sets for the complete defect liability period as and when required shall deemed to be included in the quoted rate. (iii) Any things missed out in the technical specification and as specified by manufacturers but technically required for efficient working of DG sets shall deemed to be included in the quoted rate. (iv) The quoted rate shall deemed to be included of first fill of engine oil and final successful acceptance test. (v) The quoted rate shall deemed to be included of 12 hours test run at site in the present of representative of Accepting Officer. All testing arrangements / equipement, resistive load including POL shall be made available by the contractor. (vi) Cost of Foundation using PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) (below ground level 20 cm and above ground level 30 cm) or as per instruction of Manufacturer but with minimum all around space of 0.50m from the accoustic enclosure) including necessary excavation and earth work shall deemed to be included in the quoted rate. (vii) Foundation drawing as per the manufacturer's recommendation to be submitted to the AGE(I) through Engr-in-charge for approval from Accepting Officer before commencement of work.
SCHEDULE "A" PART-VI (SCHEDULE OF CREDIT) Note :- Amount of Rs. 16050.00 indicated in Tender as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
M/S SANKAR GOPE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .