| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹9.4 L+₹28,401.25 (3.11%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹9.6 L+₹45,402.07 (4.97%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹10.3 L+₹1.2 L (13.1%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹10.3 L+₹1.2 L (13.2%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
17 Jun 2020, 6:00 pmClosed
GE NDA KHADKWASLA
GE NDA KHADKWASLA
ADDN AND ALTN TO MCB BOXES IN 15 X SQN BUILDINGS AND PROVN OF 03 X STEEL TUBULAR POLES ALONG WITH LED FITTINGS AND CONNECTED ITEMS AT G SQN TOWARDS NCO ACCN AT NDA KHADAKWASLA
2020_MES_346721_1
GE (K) 08 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
GE NDA KHADKWASLA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADKWASLA
₹24,000
Yes
6 Jul 2020
22 May 2020
19 Jun 2020
23 May 2020
17 Jun 2020
4 Jun 2020
24 May 2020 - 3 Jun 2020
Amount
Supply and fixing factory made epoxy powder coated Distribution Board TP & N 8 way (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout and making good disturbed surface and touch up with the same finishes complete all as specified. including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and existing circuits complete as reqd at site
Supply and fixing factory made epoxy powder coated Distribution Board TP & N 4 way (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout and making good disturbed surface and touch up with the same finishes complete all as specified including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and existing circuits complete as reqd at site
S&F in replacement MCB DB 08 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and existing circuits complete as reqd at site
S&F in replacement MCB DB 04 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and existing circuits complete as reqd at site
S&F MCCB with rating of 125 Amps, 415Volts 3 pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu). MCCB should be with suitable spreaders and phase barriers for each terminals.
S&F MCB TPN 63 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing.
S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing.
S&F MCB DP 40 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified.
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 19 mm with all fitting & other accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed (Two runs of 04Sqmm cable with 01run of 04Sqmm earth wire along with casing caping shall be measured as one RM)
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 19 mm with all fitting & other accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping shall be measured as one RM)
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including concelaed PVC conduit medium grade not less than 19mm complete with accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with PVC conduit shall be measured as one RM)
S&F in replacement LED 90 watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl fixing to pole with necessary nut, bolts and washers complete all as specified and directed Make Havells Model No ENDURACITYLINERNEOSL90WLED757SASYBOTG or eqv in other approved makes
S&F in replacement of GI pipe bracket of 40 mm dia 1.2 mtr long bend to shape for street light fitting made out of 40 mm dia GI medium grade pipe fixed on pole using existing FI clamp including necessary new nut, bolt and washer complete all as specified and directed.
M&L for laying XLPE underground cable 10 sqmm 4 core armoured sheathed with PVC cable stranded aluminium conductor 1100 volts grade
S & F PVC insulated copper conductor 3 core 2.5 sqmm for from junction box to street light fitting ,multistranded with suitable lugs complete all as specified and directed. Make Gloster/Polycab/Havells
Supply and fix SMC junction box with connector for connecting incomming and outgoing of cable including 01 No MCB DP 06 Amps to control the pole light circuit and suitable MS brackets fixing the box on post complete with nuts, bolts and wahers and suitable size of double compression cable glands for incomming, outgoing of cable complete all as specified .Make Sintex Cat pat No GSJB-3020 or equivalent in other approved Makes
Material and labour for boring in existing road crossing by providing suitable T & P to make suitable size bore for fixing 50 mm dia pipe in road crossing etc omplete all as specifed and directed. Note: 1. Quoted rate shall be incl of 50 MM GI medium grade pipe 2.Quoted rate shall deemed to incl the cost of making good the disturbed surface and match with existing.
Excavation in trenches in soft/dis integrated rock n exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and directed.
Excavation in trenches in hard/dense soil n exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and directed.
Ditto all as per item No 20 above but beyond 1.5 mtr depth and getting out complete all as specified and directed
Returning filling in including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing excavated surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5 mtr above starting point all as specified and directed.
M&L for laying of reinforced concrete pipe, dia of 100 mm 2 nos half round for bottom and top and before laying excavated area shall be levelled all as specified and directed by Engineer-In- Charge . Note: One half round Top and One half round bottom together will be considered as one length.
Supply & fix GI tubing light grade 40 mm dia isi marked with all fittings laid in trenches and fixed pole by flat iron clamps,ut,bolt,washers suitable size all as specified and directed at size.
Supply, transport, errecting and fixing steel tubular swaged welded pole of over all height 8.5 m long complete type 410-SP-22 conforming to IS-2713 (Part I to III 1998 with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed by Engr-in-charge. Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of coping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer. (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer (iv) Pole below ground shall be tarred by one coat (v) Poles shall be numbered and the rate for above items shall be deemed to be inclusive in the quoted rate.
M&L for PCC (1:3:6) type C-1 (Using 40 mm graded stone aggregate) Cement concrete in foundations, filling and mass concrete complete all as directed.
M&L for PCC (1:4:8) (Using 40 mm graded stone aggregate) Cement concrete in foundations, filling and mass concrete complete all as directed.
M&L for PCC (1:3:6) type C-1 (Using 20 mm graded stone aggregate) as in coping of pole sand including formed work complete all as specifed.
SONU ENTERPRISES
KESARI AND SONS
Sneha Aircool
Mehta and Co.
R. K. Industrial Fabricators
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .