Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹26.3 L+₹2.8 L (12.0%)Rejected-Finance 254 MG ROAD LAMBA LANE JUNGLIGHAT PORT BLAIR SOUTH ANDAMAN ANDAMAN AND NICOBAR ISLANDS 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹28.7 L+₹5.2 L (22.3%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹29.0 L+₹5.5 L (23.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹29.3 L+₹5.8 L (24.6%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹24.4 L
EMD Value
₹48,800
Closing Date
31 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
PROVISION OF COMMAND AND CONTROL SYSTEM ROOM FOR IUDHSS AT NAVAL WHARF, PORT BLAIR
2022_MES_500417_1
8597/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class E Category a(i) and b (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹48,800
Yes
16 Feb 2022
8 Jan 2022
5 Feb 2022
8 Jan 2022
31 Jan 2022
24 Jan 2022
8 Jan 2022 - 20 Jan 2022
60 days
Amount
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
M&L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for 100mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) finishing cement concrete suface even and smooth using extra cement including making impression of expanded metal while concete is green all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in chajjas complete all as specified and as directed.
M&L for design mix reinforced cement concrete M-30 grade (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, cooking platforms and in shelves and the like complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for use and waste of formwork to sides of sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc., also splays between floors and beams etc., for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to chullah, hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for 4mm thick epoxy floor with Anti static grid with copper strip 40mmx5mm thick 1 mtr grid intervals and connected to earth pit complete all as specified and directed.
M&L for screed bed 12mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement on RCC roof surfaces, finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for preparing plastered surfaces and applying a coat of cold applied bituminous primer over cleaned roof/ sunken surface @ 0.30 Kg/sqm and applying one coat of hot blown bitumen 85/25 grade @ 1.2 Kg/Sqm over primer followed by 3 mm thick APP modified 5-layered polymeric water proofing membrane weighing not less than 3.5 Kg/sqm reinforced with polyester non-woven fabric weighing not less than 150 grams/sqm laid as per the manufacturer instructions with side over lap of 100mm & end over lap of 150mm & tucked into the chases on roof, sunken slabs, edges and vertical surfaces and finally applying bitumen based paint @ 1.2 litres/Sqm complete all as specified and directed. MAKE: STP Limited/ PIDILITE INDUSTRIES LIMITED (Dr. FIXIT TORCHSHIELD P3160)/ IWL INDIA LTD
M&L for applying a coat of bituminous aluminium paint @ 0.15 Kg/sqm over bituminous surface complete all as specified and directed. MAKE: STP Limited/ PIDILITE INDUSTRIES LIMITED/ IWL INDIA LTD
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for rendering 5mm thick in CM (1:4) on fair faces of brick work or concrete, surfaces finished even and smooth complete all as specified and as directed.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.
Supply only water proofing compound
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion over a coat of primer after applying 3mm thick wall care putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling of any description and applying three coats of white wash leveling the undulations if any with cement putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of external walls of any description and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer complete all as specified and as directed.
M&L for seamless gypsum board false ceiling 12 mm thick including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with joining compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flange of 20mm and 30 mm, web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer after applying 3mm thick putty complete all as specified and as directed.
S&F venetian blinds for windows/doors, vertically hanged from powder coated steel track with hand drawn control mechanism, thread interconnected, solid pattern, including fixtures and fittings with 90° rotation of blinds to allow light to pass or to fold up on one side of a window/door complete all as specified and as directed.
M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
Supply only aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
Supply only 5.5 mm thick plain sheet glass, ordinary type and glazing with aluminium glazing clips in square, not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only 4.0 mm thick plain sheet glass, ordinary type and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side with balancing white lamination complete all as specified and as directed.
S&F anodised aluminium grill of approved pattern, anodised powder coated, cut to required size and shape, fixed in position with aluminium beading & frame made of aluminium F-section fixed to aluminium windows/ventilators complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 110 mm complete all as specified and as directed.
S&F PVC (SWR) bends with access door any radius, diameter of outlet 110 mm complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit concealed/surface (not less than 25mm) as suitable at site and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for the following:-
One LIGHT point controlled by ONE 1 way 6 Amps switch.
ONE 6A SOCKET OUTLET point controlled by ONE 1 way 6 Amps switch on independent board.
ONE 6A SOCKET OUTLET point controlled by ONE 1 way 6 Amps switch on same board.
M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit concealed/surface as suitable at site and accessories fixed on walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps switch on independent board.
S&F modular switch, one way, one module, single pole, 6 Amps complete all as specified and as directed.
S&F modular switch, one way, one module, single pole, 16 Amps complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin combined, 2 module, single pole, 6 Amps complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin, 6/16 Amps combined, 2 module, single pole, complete all as specified and as directed.
S&F modular electronic fan regulator for ceiling fan, step type, 5 speed, AC, 2 module, 120 watts, 240 volts complete all as specified and as directed.
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S&F Tube light fittings LED 20 watts 4 feet including all accessories and fixing arrangements complete all as specified and directed Make :CG Cat Part No : CCS-100-20-65-HL2-DP-NWH/ Philips Cat Part No : Astra line plus/C&S/Havells
S&F MCB, SPN, 230 volts, 63 Amps, C series 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No : 811154 /L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCCB, 4 Pole, 125 Amps, 50 Hz, 415 V with 25 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN /L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811122 to 811129 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M&L for chemical earthing with copper plate 90 x 60 x 5mm, galvanised steel pipe electrode 40mm bore, medium grade, 2.5 mtr length, buried directly and preferably vertically in gound with top edge not less thn 1.25 mtr below ground level connected with earthing lead of copper earth strip 32x6mm dia all as shown in Electrical plate No. 2 to the earthing test point complete all as specified and indicated including testing on completion all as specified and as directed
S&F starter switch of capacity 25 Amps working on 240 Volts, AC supply suitable for split type airconditioner complete all as specified and as directed. MAKE: CRABTREE Cat part No. ACTO252504 or equivalent in ANCHOR/HAVELLS/L&T
S&F ceiling fan of three blades, remote controlled, 1200mm sweep, 340 RPM, 65% energy saving, suitable for AC 230 volts, heavy duty with down rod and canopies complete all as specified and as directed. MAKE: Atomberg Model: Studio or equivalent in Havells/ Usha/ CG
S&F wall mounting type oscillating air circulating fan with remote control, 400mm (16") sweep, 1350RPM, working on 230 volts, 50 Hz, single phase, AC supply complete all as specified and as directed. MAKE: Atomerg, Model: Efficio or equivalent in Havells/USHA/ CG
S&F Exhaust fan 150 mm sweep, Stainless steel body, 6.5 watts, energy efficient, with louvers including all fixing arrangement complete all as specified and directed Make: Atomberg Model : Studio or equivalent in CG/ Havells/ Orient/ Usha
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 70 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for HDPE DWC (Double wall corrugated) pipe of size 77mm (Outer diameter) x 63mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
S&F recessed mounted 18 watts, down light round shape, LED panel light fitting with ultra bright luminarie comprising thermally conductive material, pre wired with high efficiency electronic driver with all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: PHILIPS Cat part No. Astra Max Metal Panel/ CROMPTON GREAVES Cat Part LSCRM-18W-CDL/NW/WW or equivalent in HAVELLS/C&S
S&F street light mounting bracket made up of 25mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F LED security light fitting, 1x25 watts, 230 volts, 50Hz Ac supply, with high power and high efficiency long life LEDs with built-in electronic driver, unique peanut lens to ensure uniform distribution completely housed, complete all as specified and as directed. MAKE:CROMPTON Cat Part No. LSTS-25-CDL-M or its equivalent in Philips/ Havells
S&F MCCB DB sheet steel enclosure, VTPN, 4-way, double door, 415 Volts with 200 Amps rated bus bar, IP-43 protection suitable for incoming MCCB 125 Amps and outgoing MCB TP/SP, enclosed in standard steel sheet flush mounting type, factory fabricated complete all as specified and as directed. MAKE: L&T/ LEGRAND/ SIEMENS/ INDO ASIAN/ HAVELLS
M&L for providing anti static mat as per site requirement all as specified and as directed
S&F Electronic voltage stablizer of 50 KVA capacity automatic operation, three phase, naturaly oil cooled, indor type & designed for input variation between 340 Volts to 460 Volts with output voltage stablized at 415 Volts, with accuracy of +2.5% and speed of correction 8 volts per second complete all as specified and as directed. MAKE: V-GUARD/ Premier
S&F Electronic voltage stablizer of 4 KVA capacity, wall mounting type having features such as Intelligent time delay system of 2 to 4 minutes, low and high voltage cut-off protection, latest IC technology to protect from power fluctuations, thermal over load protection, wide input variation between 165 Volts to 295 Volts with output voltage stablized at 200 Volts to 240 Volts, with accuracy of +2.5% suitable for split type airconditioner complete all as specified and as directed. MAKE: V-GUARD/ Premier
Supply, install, test & commissioning of Split type air conditioner, 2.0 TR capacity,BEE 5-Star rating, having cord less remote control unit, wall mounted inverter type with built-in ioniser and plasma filter for better air quality, copper wound, electric driven, single phase, 240 volts, 50 Hz, AC supply including transporting to site, fixing of indoor and outdoor units with necessary wall mounting brackets, necessary copper piping minimum 8 RM for connections, cutting, bending, brazing, proper insulation on copper pipe and all other pipes, PVC drain pipe upto ground level, installation complete with all accessories including connecting electrically between indoor and outdoor units with suitable size of PVC insulated multistranded copper conductor, 01 No spare PCB for each AC complete all as specified and as directed. MAKE: BLUESTAR /VOLTAS/LG/HITACHI NOTE: All connected pipes shall be covered with PVC casing and capping.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 32x6mm GI earth strip as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed
S&F earth continuity conductor or main earth lead 25x4mm GI Strip laid in pipe/fixed on walls or any other positon including jointing by GI nuts, bolts and washers in addition to brazing at every joint complete all as specified and as directed.
S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed
S&F copper earth strip 25x3.15mm as in roof conductors/ down conductors fixed on walls/roofs with saddles & epoxy insulators including screws required at site complete all as specified and as directed
S&F 40mm bore GI Tubing, light grade with all fittings fixed to walls/ poles/ laid in trenches as in earth lead protecton pipe complete all as specified and as directed
Kakolil Trade Agencies
Sree Tirumala Enterprises
DHAKSHNA MOORTHY AND SON
M/s Ramesh Lal
bansal construction
MGP Enterprises
NAVJEEVAN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .