Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹36.8 L+₹6.6 L (21.7%)Rejected-Finance KALAPAHAR BIMALANAGAR GUWAHATI 781016 DISTT KAMRUP ASSAM | KAMRUP METRO | ASSAM | 781016 | L2 | Rejected-Finance Not Validated, Other than Lowest | |
| 3 | L3₹38.0 L+₹7.8 L (25.8%)Rejected-Finance OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | L3 | Rejected-Finance Not Validated, Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹76,700
Closing Date
9 Apr 2022, 6:00 pmClosed
GE Guwahati
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
SPECIAL REPAIR TO BLDG NO T-9 AND T-10 AT IWT UNDER GE GUWAHATI
2022_MES_513648_1
GE/GUW/64/8190 OF 2021-22
Open Tender
Civil Works
Item Rate
150 days
Guwahati
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE GUWAHATI
₹76,700
Yes
24 May 2022
14 Mar 2022
11 Apr 2022
14 Mar 2022
9 Apr 2022
28 Mar 2022
14 Mar 2022 - 21 Mar 2022
Amount
Demoliation Brickwork masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed
M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed
M&L brick work with sub class 'B' bricks, old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
M&L for 15mm thick rendering with cement mortar (1:4) on fair faces of brick work in two layers (10mm & 5mm) seperately mixed with water proofing compound in top layer as per manufacturer's instructions and finishing the surface even and fair without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for Rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall, applying 2mm thick of wall care putty over plastered surface to prepare the surface even and smooth and Finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) cement complete all as specified and as directed.
M&L for prepration of new plastered surfaces of wall, applying 2mm thick of wall care putty over plastered surface to prepare the surface even and smooth and applying two coat of oil emulsion distemper over specific thickness wall care putty to obtained smoothness of plastered surfaces complete all as specified and as directed.
Dismantling of asbestos cement (corrugated, semicorrugated) etc sheets in roof covering complete all as specified and directed.
S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Prepainted galvalume aluminium zink coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and as directed
Taking down roof trusses, coupled rafters or trussed beams, clear span Above 4 metres & upto 8 metres complete all as specified and as directed
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete and making good disturbed ground complete all as specified and as directed
S&F framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed baluster; walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position from unframed work complete all as specified and as directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
S&F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed. complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length exc 5cm but n exc 10cm long long, Diameter of neck in 11 to 15mm complete all as specified and as directed.
M&L for preparing new steel surfaces of any description, not otherwise describe over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
Demoliation cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, removing surplus soil to a distance not exc 50meters and making good the distrubed surfaces in soft/loose soil, scomplete all as specified and as directed
M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in mass concrete complete all as specified and as directed.
M&L providing plain cement concrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
M&L taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each. complete all as specified and as directed.
M&L taking down chowkat with shutter without taking off shutter from the frame exc 1.5 Sqm n.exc 4 Sqm each complete all as specified and as directed.
S&F pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc. size of frame 125mm x 60mm complete all as specified and as directed.
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, one face is covered with decorative face veneer with lipping/frame to match complete, all as specified and as directed.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part -I. section 8, clause 8.24(a), complete all as specified and as directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples as in windows with and including suitable size of 2nd class hard wood beading complete all as specified and as directed.
S&F 125mm long aluminium anodized, barrel tower bolts of extruded section and fixed, complete all as specified.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedr complete all as specified and as directed.
S&F 100mm butt hinges, medium weight cold rolled, MS steel complete, all as specified and as directed.
S&F 150 mm aluminum handle cast type anodized, complete all as specified and directed.
S&F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L preparation of new wooden surfaces of any description, over 10cm in width or girth, not otherwise described, and applying two coats of synthetic enamel paint (1st quality) over a priming coat of pink primer complete all as specified and directed.
S&F Colour coated Anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directed Note:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
S&F Colour coated anodised aluminium windows/ventilators/partitions any type including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directed Note:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paid seperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
Supply only 4mm thick frosted sheet glass on one side, ordinary quality fixed with Aluminum frame work n. exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for RCC (nominal mix) (1:2:4) type B1 using 20mm graged stone agreegate as Beams, cantilevers, bressummers, lintels over 1.5m span, including demoliation and removing debries from the site complete all as specified and directed.
M&L formwork to soffits to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., finished fair complete all as specified and directed.
M&L TMT Bars 10mm dia and Over, cut to length, bent to shape as required including Cranking, Bending, Hooking Ends and binding with Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
M&L TMT Bars 5mm dia and over upto and including 10mm dia as in Stirrups, Spacers etc. cut to length, bent to shape required including cranking, bending, hooking ends and binding with Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and scantaling all as directed.
M&L false ceiling with 10 mm thick, 600mm x900mm plaster of Paris sheets fixed with machine screws on and including GI channel 18 gauge thick grid work, main joists placed at 750 mm centre to centre , cross joists placed at 450mm centre to centre, hanging with 6mm dia GI wire suspenders from roof, ‘J’ hooks bolts and nuts etc and treating the POP sheets with thin layer of POP with Gypsum anhydrous binder and prepare the surface till smooth surface is achieved; and applying two coats of distemper oil emulsion paint over a coat of primer complete as per manufacturer’s instructions and as directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debries/rubbish complete all as specified and directed.
M&L Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement moryar (1:6) complete all as specified and as directed.
M&L Coloured glazed ceramic tiles 300 x 450 x 7 mm thick in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing with cement moryar (1:4) complete all as specified and as directed.
M&L Hardcore, broken stone or boulders, of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfacecomplete all as specified and directed.
M&L for Cement Concrete1:4:8 Type D-2(using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M &L Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete, all as specified and as directed.
M &L Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete, all as specified and as directed.
S&F decorative stainless curtain rod of wooden finish 20mm dia thickness not less than 0.75mm, fixed with curtain rod holder fixed in walls with screws and finials caps with 6 Nos of curtain ring per RM complete all as specified and directed. Note: Curtain rod holder and finials caps will be measured and paid seperately at Supply only rates)
Supply only decorative stainless curtain holding braket suitable for holiding 20mm curtain rod heavy duty complete all as specified and directed.
Supply only decorative stainless steel finial end cap suitable for curtain rod of 20mm dia as approved complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for concealed point wiring with two single core 1.5 Sq.mm size FRLSH multistranded copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green FRLSH colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including 20mm(minimim) medium grade rigid PVC CONDUIT and conduit accessories i.e. joint boxes, terminal boxes for mounting or housing switches, socket outlets, fan regulators, etc. confirming to IS specifications, including provision of flush modular mounting boxes, with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for MS Sunken boxes & making good to walls, floors etc. complete all as specified & as directed for the following :- Item continued as 60 to 62
One light/fan point controlled by one one way switch
One 3 pin socket outlet 5 amps on the same board with other switches
One 3 pin socket outlet, 5 amps, on independent board
M&L for concealed point wiring for one socket out let 15/16 amps point on the independent board with two single core 4 Sq.mm size FRLSH multistranded copper conductor PVC insulated cables and one single core 4 Sq.mm size green FRLSH colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including 20mm(minimim) medium grade rigid PVC CONDUIT and conduit accessories i.e. joint boxes, terminal boxes for mounting or housing switches, socket outlets, etc. confirming to IS specifications, including provision of flush modular mounting boxes, with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for MS Sunken boxes & making good to walls, floors etc.complete all as specified & as directed
S&F Modular switch, one way, 10 Amp, 1 Module, 240 volt, ISI marked complete all as specified and as directed.
S & F Modular shuttered socket outlet 5 Pin, 6 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed.
S&F Modular switch, one way, 16 Amp, 1 Module, 240 volt, ISI marked complete all as specified and as directed.
S & F Modular shuttered socket outlet 6 Pin, 6/16 Amp, 2 Module, 240 volts, ISI marked ISI marked complete all as specified and as directed.
S&F Modular type fan regulator step type120Watt (05 steps) for energy saving fans, 2 Module, ISI marked complete all as specified and as directed
S&F ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminals, complete all as specified and as directed.
S&F Lamp holder PVC polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F of moudlar cover plate with frame for 3 module complete all as specified and directed.
S&F of moudlar cover plate with frame for 6 module complete all as specified and directed.
S&F of moudlar cover plate with frame for 8module complete all as specified and directed.
S&F Wall mounted indoor decorative 9 Watt LED INVERTER lamp upto 4 hours back up time complete all as specified and directed. Make : Crompton Cat No. LED9WDFINV4CDL/HAVELLS/HALNOX or equivalent make of same specification as approved.
S&F LED lights fitting 1x 20 Watt, (or next nearer higher watt) 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
M&L Sub main wiring with 6 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, FRLSH copper conductor cables 1100 V grade drawn through and including PVC casing caping of adequate size but not less than 25mm width including 6 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, FRLSH copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed including taking down old sub main wiring. Notes;- (i) 2 Runs of 6Sqmm main cable and 1Run of 6Sqmm earth wire along with 1 Run of PVC casing caping with acessories shall be measured as one unit length
S&F Sheet metal enclosure for 8 way VTPN Distribution Boards (DB’s), IP-43 double door, with 400 amps rated bus bar, suitable for hosing MCCB as incommer and MCB's as outgoing including blanking plates as required and flush to wall surface complete all as specified and as directed. Note : Incomming MCCB and Outgoing MCBs measured and paid seperately under relevant item
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with 200 amps rated bus bar, including blanking plates as required and flush to wall surface complete all as specified and as directed. .
S&F MCCB, 4 Pole, 63 Amps, 415 volts, 16 KA complete all as specified and as directed.
S&F MCB Single pole and Neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed.
S&F MCB Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed..
S&F in repair, 18 Watt slim recess mounted LED light fitting with high brightness, glare free homogenous illumination of size 205x 205x 70mm including making required celing cutout and including connecting up with driver with three core flexible copper conductor of suitable size complete all as specified and as directed
S&F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed
S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, UG Cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed.
Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed. NOTE : Punned thickness 18cm shall be considered for payment as per para 19.75 of SSR Part-I.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
M&L earthing with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth strip protected by and including PCC (1:2:4) type B1 precast RCC cover slab (M-15)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete
M/S M.S. ENTERPRISE
M/s Dhani Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .