| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹24.1 L+₹4.7 L (24.4%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
27 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (P) AF Gurgaon
GE(P) AF Gurgaon, Near Atul Kataria Chowk Gurgaon Haryana 122005
CA NO GE(P)AF/GUR-76/2020-21 PROVN OF CERTAIN B R AND E M SANCTIONED WORKS IN 13 BRD, 27ED AT AF PALAM AND 54 ASP AT AF STN GURGAON UNDER GE (P) AF GURGAON
2021_MES_417288_1
GE (P) AF/GUR-76/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) AF Gurgaon
All as specified in NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹43,000
Yes
5 Mar 2021
29 Jan 2021
1 Mar 2021
30 Jan 2021
27 Feb 2021
13 Feb 2021
60 days
Amount
S&F Grease trap of 1 VEC Model No A500 grease seprator made of stainless steel 304 grade for ground installation acording to EN-1825 & Din 4040 with max diamensions 1400mm x 1000mm x 1000mm with total capacity of appx 1500 ltrs, sluge capacity of 1010 ltrs and grease storage capacity of 450 ltrs, inlet and outlet connections of DN 150 disposal via direct suction line DN-65 PN-10 outlet flage and s10z hose quick coupling and blind cover for load class A-125 according to EN-124 with frame from concrete cover from cast iron clear opening as per outer dia cover odour proot and water marked by GMRR or equivalent including necessary excavation & earth work complete all as specified and as directed by Engr-in-charge.
Removing excavated surplus soil out side from the MD land at contractor's own arrangement and depositing the soil where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
S&F of Reinforced cement concrete drain Pipes 150 mm dia NP-2 , laid in trenches in foul condition, Jointed with collars in cement mortar 1:2 and tested, complete all as specified and as directed.
M&L for Cutting into existing Manhole for removing existing Branch Drain Pipes, Making Good to Brick Wall and Rendering, cutting out Branch Channel and making good in Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) and reforming Benching for 150mm internal dia Drain Pipe in Foul Condition, complete all as specified and as directed.
M&L for cement concrete 1:3:6 (20mm Graded crushed stone aggregate) Bed for drain pipes of bore 150mm including packing under and haunching against the sides of pipes after they are laid in foul condition and testing, complete all as specified and as directed.
M&L for rifle rack for 10 rifles (one side pattern) made with 1st class hardwood shesham, seasoned wood wrought on faces, semi circular, rounded or chamferd put together with glue fevicol SH grade at jointed with locking arrangement and fixed on the wall and floor and french polishing complete all as specified, as directed by Engr in Charge and shown on drawing CE (AF)/NGP/TD-78/2006 all as specified and directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete all as specified and as directed by Engr-in-Charge.
Excavation of Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engineer-in-charge
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm complete all as specified and as directed
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed by Engr-in-charge.
M&L for PCC 1:2:4 type B2 using 40mm grade stone aggregate as in copping of electric pole or making good of disturbed surface complete all as specified and as directed by Engineer-in-charge.
M&L complete for driling hole hard standing / road for laying of pipe for protection of cable etc by means of manual booklet and without disturbing the top surface or cutting and making good the disturbed surface to the existing if any complete all as specified and directed by Engineer-in-charge.
Supply and laying GI tube light grade 80 mm bore complete all as specified and directed by Engr-in-charge.Make - Bansal/Jindal/ITC
Taking out old serviceable /unserviceable underground cable of 95 Sqmm 3.5 core size from excavated trenches /pipes complete all as specified and as directed by Engr-in-charge. (Earth work, segregating cable cover measured separately).
Taking out old serviceable /unserviceable underground cable of 120 Sqmm 3.5 core size from excavated trenches /pipes complete all as specified and as directed by Engr-in-charge. (Earth work, segregating cable cover measured separately).
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and as directed by Engr-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and as directed by Engr-in-charge.
Taking down existing old LT panel board/ LT feeder pillar box comprising of MCCB & switch fuse unit of any capacity and size including bus bar, ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as specified and as directed by Engr-in-charge.
Supply, fabrication, installation & commissioning of dust & vermin proof totally enclosed, outdoor type LT, 3 phase 4 wire feeder pillar box factory made (CPRI approved), double door cubical type of suitable size made by 3.15mm thick ms sheet with MS angle iron frame of size 40 x 40 x 6mm slanting roof, front door opening with locking arrangement complete painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary PCC, fixing with PCC 1:2:4 of size 0.2m x 0.2m x 0.2m for 4 Nos legs, inclusive of under mentioned items fixed inside with suitable arrangement vertically operated and internal connection with PVC insulated stranded single core copper cable of suitable size or using insulated copper strip of appropriate size and connection of all incoming and outgoing cable including extended the cable from cable loop if required using aluminium cable terminal sockets / lugs duly crimpled comprising of following:-
M&L for sub main wiring two run of 06 sqmm and one run of 4 sqmm continuous earth wire PVC insulated unsheathed copper conductor cable ISI marked 1100V grade drawn in and including PVC surface conduit suitable size of medium grade fixed on wall/ceiling/passing through wall etc connected as required at site as in replacement complete all as specified and as directed by Engr-in-charge.
M&L for sub main wiring four run of 06 sqmm and two run of 4 sqmm continuous earth wire PVC insulated unsheathed copper conductor cable ISI marked 1100V grade drawn in and including PVC surface conduit suitable size of medium grade fixed on wall/ceiling/passing through wall etc connected as required at site as in replacement complete all as specified and as directed by Engr-in-charge.
M&L for sub main wiring two run of 04 sqmm and one run of 2.5 sqmm continuous earth wire PVC insulated unsheathed copper conductor cable ISI marked 1100V grade drawn in and including PVC surface conduit suitable size of medium grade fixed on wall/ceiling/passing through wall etc connected as required at site as in replacement complete all as specified and as directed by Engr-in-charge.
S&F in replacement MCB DB double door type SPN upto 8 way complete all as specified and as directed by Engr-in-charge.
S&F in replacement MCCB DB double door type TPN upto 8 way vertical type without MCCB complete all as specified and as directed by Engr-in-charge.
S&F in replacement MCCB 3 pole 415 V fixed type 125 Amps with breaking capacity 16 KA (Loadline) complete all as specified and as directed by Engr-in-charge.
S&F of MCB SP-6-32 Amps, 240 Volt B series type complete all as specified and as directed by Engr-in-charge.
S&F in replacement MCB SPN 40 Amps,240 Volt B series type complete all as specified and as directed by Engr-in-charge.
S&F in replacement sheet metal enclosure with socket plug top and 240V Single pole and neutral with two pin, earth plug and socket including single pole MCB 20 Amp, 10 KA complete all as specified and as directed by Engr-in-charge.
S&F Industrial Socket outlet 2P +Earthing 230V Capacity 32 Amp water tight IP-67 protection fixed on surface mounting complete all as specified and directed by Engr In Charge Make : Neptune /Havells/Bajaj
S&F Industrial Plug water tight 2P +Earthing 230V capacity 32 Amp water tight IP-67 protection complete all as specified and directed by Engr In Charge. Make : Neptune /Havells/Bajaj
M&L wiring sub main wiring concealed along with earth wire with the following size of HRFR PVC insulated and unsheathed multistranded copper conductor single core cable in concealed through 25 mm rigid not metallic PVC conduit heavy duty with 2 x 4 sqmm + 1 x 2.5 sqmm earth wire complete all as specified and directed by Engineer-in-charge. including cutting chesses pinning in making good to facing and pointing in cement morter 1:3 to the ends or cutting chesses for conceled point wiring and making good distrubed surface complete cutting not exceeding 4 cm girth and 4 cm width. Note:- Two run of cable and one length of PVC conduit with earth conductor shall be measured as a one length complete all as specified and as directed by Engr-in-Charge.
S&F MCB, SPN, Breaking capacity min 10KA,'C' curve 230V, 6 to 32 Amps complete all as specified and as directed by Engr-in-Charge.
M&L for Ceiling Fan 1400mm sweep 3 blade single phase 5 star energy rating 230V 50 Hz,complete with all accessories complete all as specified and as directed by Engineer- in Charge. (Make:- BAJAJ/ ORIENT/CG) Note :Ceiling fan rod covering length 6 feet required at site and Fan rod fixing connecting accessories Including this job, no extra cost pay govt
M&L for point wiring (concealed on wall & surface/concealed on ceiling) for One light/fan/exhaust/bell controlled by one modular/piano switch one way in different locations/buildings including rigid non metallic PVC conduit, medium grade, ISI marked, 20 mm dia, with 1.5 sq mm FRLS PVC insulated & unsheathed, stranded copper conductor cable, single core, 1100 volts grade, with concealed, flush metal terminal boxes of 1.6mm size & suitable depth for mounting modular type switches, sockets, fan regulator etc including FRLS insulated and unsheathed solid copper conductor of 1.5 sqmm as continuous earh conected to common earth dolly, including top white cover sheet with frame, complete all as specified and derected by Engr-in-Charge.
S&F ceiling rose 3 phase PVC carbonate complete all as specified and as directed by Engineer-in-charge.
S&F switch Modular one module one way 10 Amp complete all as specified and as directed by Engineer-in-charge.
S&F Modular Electronic Fan regulator stepped type two module complete all as specified and as directed by Engineer-in-charge.
S&F Kitchen exhaust fan 300 mm sweep metal body with front grill and outside louvers complete all as specified and as directed by Engineer- in Charge. Make:- BAJAJ/ ORPAT/Philips
M&L for Flood light, highly efficient, integral type LED flood light made out of pressure die cast aluminium housing with 10 KV SPD, lens and toughened glass, plotted driver with efficacy of 120 lm/Watt IP66 complete with all accessories internally pre-wired for 150 Watt complete and including LED lamp 150 Watt and fixing in walls or steel trusses in frames fabricated out of MS flat 450 mm length,(25 x 4 mm), with nuts and bolts of 8 mm shank and 10 mm long complete with washers and fixing all as directed by Engr-In-Charge after giving the relevant electrical connections. (Make: Halonix, CAT No: HLFLD-ML15-150 CWL-R or equivalent of Bajaj/Philips/CG)
M&L for Flood light, highly efficient, integral type mid power, LED flood light made out of pressure die cast aluminium housing with 10 KV SPD, without lens and toughened glass, IP 66 fitting complete with all accessories internally pre-wired for 50 Watt complete and including LED lamp 50 Watt .(Make: Halonix, CAT No: HLFLD-ML17-50 CWL-HL2-P or equivalent of Bajaj/Philips/CG)
M&L for conneting up with three core flexible copper conductor cable, PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 2.5 Sqmm 3 core complete with fittings mounted in ceilings or walls as indicated carefully clipped as in cleat wiring, with use of flexible or medium grade PVC conduit whwreever required for protection from dust, water and wind complete all as specified and as directed.(Make: Havells CAT no WHMFDSKB36X0 or equivalent of Plaza/Universal
S&F Fluorescent tube light fittting flame proof FLP-WP 0f T51x28 W including integral reflector made of aluminium alloy LM6, with electronic ballest, bipin holders,connector block, etc. and all accessories pre-wired and including connecting up with twincore twisted flexible copper condector with suitable size1.5 sq mm FRHR PVC insulated & unsheathed, multi stranded copper conductor cable, single core, 1100 volts grade,passing through the steel conduit (Steel Conduit wiring) complete all as specified and as directed by Engineer- in Charge. Make:- Bajaj/Crompton/ Philips or makes specified in list of makes Note : Steel conduit point wiring shall be length covered upto 10 mtr required at site including this cost job. No Extra cost pay govt
S&F Fluorescent flame proof exhaust fan 300 mm sweep metal body with front grill,1.5 sq mm FRHR PVC insulated & unsheathed, multi stranded copper conductor cable, single core, 1100 volts grade passing through the steel conduit (Steel Conduit wiring) complete with all accessories as suitable for existing complete all as specified and as directed by Engineer- in Charge. Make:- Bajaj/Crompton/ Philips or makes specified in list of makes. Note : Steel conduit point wiring shall be length covered upto 10 mtr required at site including this cost job. No Extra cost pay govt.
S&F wall mounted fans 230 Volts single phase oscilating 400 mm sweep, with thermal overload protected motor, suitable for wall mounting and mounting complete all as specified and as directed (Make: Standard CAT No: ALFA TPW or equivalent make of USHA/POLAR/Crompton)
Supply and Installation of Three Phase Smart Prepaid Meter with the following specifications: • AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10-60A anti-tamper features, • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, • Meter should have internal or external GPRS Modem to provide connectivity with the billing software. MAKE: L&T, Schneider, Secure
Hosting and Configuration of the Web based Software with following modules (i) Meter Data Management Module The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system the meter data management system would capture and provide the following data (a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy,Cumalative Energy,Cumalative Apparent Energy, Power, Current, voltage, Power Factor and Frequency (b) Billing Module The billing module would collect the data from the meter data management module.caluculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users.
Supply and installation of 3 Phase AMR Meter Concealed Metal box Size should be maintain 51cm x 55cm x 17 cm to be fixed on LT Panel as size suitable for 3 Phase AMR meter and complete nut and bolt, Screws connecting accessories complete all as specified and as directed by Engr-in-Charge.
M&L for Cable PVC insulated unsheathed single core 1100V HRFR grade stranded flexible copper conductor of size 16 sqmm, complete all as specified and as directed by Engr-in-Charge.
Supply and install hi wall split units 1.5 Ton indoor & outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity as per directed by Engr-in-charge. Make :-Voltas/Samsung/LG /Blue Star. Note- This item includes total length of copper tuning from indoor unit to outdoor unit complete all as specified and as directed by Engr-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed by Engr-in-Charge.
S&F sheet metal enclosure with socket plug top and 240V Single pole and neutral with two pin, earth plug and socket including single pole MCB 20 Amp, 10 KA complete all as specified and as directed by Engr-in-charge.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/2” completes all as specified and as directed by Engineer-in-charge.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/4” completes all as specified and as directed by Engineer-in-charge.
Material and labour for point wiring concealed in and including rigid non metallic PVC conduit, medium grade, ISI marked, 20 mm dia, with 4 sq mm FRHR PVC insulated & unsheathed, multi stranded copper conductor cable, single core, 1100 volts grade, including flush metal terminal boxes and factory fabricated (same make of modular type switches and sockets etc.) modular metal box, cover plates inner & outer, frames of suitable size and depth, FRHR insulated and unsheathed Multi standared copper conductor of 2.5 sqmm and connected to common earth dolly as continuous earth wire (Contractor shall concealed the conduit by making chases by cutter machine then after chiselling only) for one light point controlled by one switch complete all as specified and as directed.
Disconnecting and taking down AC 1.5/2.0 TR to the ground level, transporting to store of GE(P)/54ASP all as specified and directed by Engr-in-Charge.
S&F service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tap and over all PVC sheathed of size 6 Sqmm 2 core complete all as specified and directed.
M&L for sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 with one run of 4.0 Sqmm (1x4.0 sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed.
M&L for Point wiring complete with 1.5 Sq mm (nominal area) PVC insulated flame retardent low smoke un-sheathed and multicore copper conductor cable with colour code ISI marked in and including PVC concealed conduit ISI marked and conduit fittings for one light point/fan point/engagement light controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc, complete all as specified.(cost of MS sunken box, bakelite sheet and chesing in roof/wall is included in the rate)
M&L for independent 5Amp socket point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and including PVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 1.5 sq mm as earth wire, connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate/3mm thick bekalite sheet complete all as specified and as directed by Engr-in-charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quoted rate).
M&L for independent 15Amp socket point wiring complete with 2.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and including PVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 2.5 sq mm as earth wire, connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate/3mm thick bekalite sheet complete all as specified and as directed by Engr-in-charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quoted rate).
S&F switch piano flush type single pole one way , 5 Amps , 240V grade ISI marked , complete all as specified and as directed by Engr-in-charge.
S&F switch socket outlet combination, 5 pin 5 Amps flush type controlled by one switch 5 Amps SP ISI marked complete all as specified and as directed by Engr-in-charge.
S&F switch socket outlet combination, 5 pin 15/16 Amps flush type controlled by one switch 15 Amps SP ISI marked complete all as specified and as directed by Engr-in-charge.
S&F wall mounted LED batten PVC extruted with intergated electronics driver ,20w LED 4ft , white with all accessories internally pre-wired and including connecting up with three core twisted fleixable copper conductoe cable with 1.5sqmm complete all as specified and as directed by Engr-in-charge.
S&F MCB 240 volts SPN 40 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMGCSNF040 Make Havells or equivalent out of makes specified in list of make.
S&F MCB 240 volts SP 16 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMGCSPF006-032 Make Havells or equivalent out of makes specified in list of make.
S&F MCB 240 volts SP 6 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMGCSPF006-032 Make Havells or equivalent out of makes specified in list of make.
S&F MCB 240 volts SP 20 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMGCSPF006-032 Make Havells or equivalent out of makes specified in list of make.
S&F sheet metal enclosure for MCB's (D.B) 8 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDPSHODRW08 Make Havells or equivalent out of makes specified in list of makes.
S&F FLP/WP switch/isolator 10 Amps single pole on/off for flame proof light complete all as specified and as directed.
Supply and fix refrigerator, electric driven (single phase), Fresh 440 L Frost Free Double Door Refrigerator(5 In 1 Convertible Freezer, Inverter Compressor, Alpha Steel, 3 Star, 10 Years Warranty ) complete all as specified and as directed. Make : Whirlpool/LG/Samsang.
Supply and fix exhaust fans AC single phase 230/240V of size 450mm sweep. Make : Havells TURBOFORCE sweep, 1400 Revolution per minute or equivalent in Bajaj/Philips.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% Make: V Guard model No VGSD 100 or equivalent out of makes specified in list of makes.
Supply and fix flame proof switch socket & plug combination in LM6 cable termination box in LM6, 25A,250V,2P+earth complete all as specified and as directed.
S&F flame proof exhaust fan 350mm as specified and directed by engr- in -charge, Make: Sudhir/Shyam/Bajaj.
S&F Flame proof Fan 1200mm as specified and directed by Engr-in-Charge, Make-Sudhir/Shyam/Bajaj.
Supply, fixing and laying Tubes, 'light grade' galvanised, with all fitting and fixed complete to walls and ceiling or laid in floor grade 25 mm bore complete all as specified.
Supply and fixing Electric Gong Bell 100mm with all accessories complete all as specified & as directed by Engineer in charge.
S&F Bell push , flush type, 5 Amp with rough dressing complete all as specified & as directed by Engineer in charge.
Supplying , laying , passing through pipe , connecting and testing UG cable XLPE insulated of 4 Sqmm ,4 core ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade complete all as specified & as directed by Engineer in charge.
Demolition of PCC in ground floors & pavings n. exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed by Engr-in-Charge.
M&L for providing 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engr-in-Charge.
M&L for Cement Concrete 1:2:4 (12.5mm Graded Stone Aggregate) 25 mm thick, as in sub Floors, etc., and finished the Cement Concrete Surfaces Even and Smooth with using Extra Cement, complete all as specified and as directed.
M&L for screed bed or bedding layer of cement mortar 15mm thick in CM 1:4 to receive topping as tiles , complete all as specified and as directed.
M&L for anti Acid tiles 15mm thick vitreous ceramic, unglaged, set, jointed and pointed in chemical resistance mortar, resin and all type in floor, complete all as specified and as directed.
Note:- The amount of Rs 25,682/- against Schedule of Credit on Page No 143 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
PARKASH ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .