Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 1 56G AST PETROL BUNK ERODE BHAVANI PIRIVU ROAD RS SANKARI SALEM 637 302 | SANKARI | SALEM | TAMIL NADU | 637302 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
14 Mar 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Commissioner, Idappadi Municipality
The Commissioner, Idappadi Municipality, Idappadi-637105, Salem Dist.
IDAPPADI MUNICIPALITY-Construction of Additional Toilet block, Renovation of Existing Damaged Compound wall at ward no.15 Kavandampatti Municipal Middle school in Idappadi Municipality
2023_MAWS_293992_1
1648/2022/E2
Open Tender
Civil Works
Works
60 days
Idappadi Municipality at Kavandampatti
Qualified Contractor
2 documents required · 2 mandatory
₹0
₹10,000
14 Mar 2023
9 Mar 2023
14 Mar 2023
9 Mar 2023
14 Mar 2023
9 Mar 2023
Amount
Dismantling of Existing brick wall at Damaged area of Toilet and other Charges etc., complete
Earth work deploying earth moving machineries for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc., complete
Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation and basement with filling M-sand in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement concrete 1:4:8 Mix ( One cement ,Four M.sand , eight aggregate) using 40 mm ISS Hard Blue Granite metal including cost and conveyance of all materials and labour charges etc,complete as per standard specification
Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D) etc complete.,
Providing and laying Standardised Concrete Mix M-20 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minium cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charge, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor/roof slabs wherever necessary without claming extra etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards.
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. including charges for cutting, Straightening, and bending, typing, Welding, Jointing, over laping and all labour charges etc.
Brick work in following Cement Mortar 1:5 ( one cement and five sand) using best quality Fly Ash bricks of size 230x110x75mm for foundation and basement including curing etc.,complete complying with standard specification.
Brick Partition Walls using III class ground moulded chamber bricks of size 8 3/4"X4 1/4" X 2 3/4" in C.M 1:3 using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm
Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
Plastering with CM 1:5, 12mm (one cement and five M. sand) thick including cost and conveyance of all materials to site and labour charges etc. complete as per standard specifications
Painting two coats with approved plastic Emulsion paint over cement plastered wall surface, ceiling and other new surface and including cleaning, preparing the surface and curing etc., complete.
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
Painting two coats of new iron works such as steel gate, Windows, Ventilators window bars, Balustrades, etc, with best approved first quality of synthertic enamel paint of apporved colour over the existing priming coats etc, complete.
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement
Supply and fixing of Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rebate for housing the shutter.
S/F in position of Indian Make White/Colour glazed earthen ware lipped mouth Flat Back Urinal of best approved quality with G.I.Pipe connection to suitable length,32mm bell mouthed P.V.C connection ,15mm dia G.M.Wheel valve,fixing the urinal to the wall in position with necessary T.W.plugs ,clamps,screws, shellac etc.,including dismantling masonry if necessary and redoing the same to original condition ,fixing the 15mm dia. G.I.pipe connection and wheel valve ,painting the pipe with two coats of approved paint over one coat of primer and checked without any leakage complete, complying with standard specifications. - White Colour
Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100mm 'P' os 'S'' trap with Double flapped rigit P.V.C. seat cover with C.P. brass hinges with 12.5 litres PVC Low Level Flushing Tank with all internal fittings etc., complete complying with standard spoecifications,labor inclusive of fixing lowlevel flushing tank.
Supplying and fixing UPVC (Un-Plasticized PolyvinylChloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supplying and Delivery of the following PVC and specials best approved quality conforming to ISS and providing leak proof joint with PVC adhesive etc., complete complying with standard specification.
90mm PVC pipe
25mm PVC pipe
20mm PVC pipe
Reducer 90mmx20mm
Reducer 20mmx15mm
90mm Bend
90mm Elbow
20mm Tee
20mm Elbow
25mm Tee
25mm Elbow
Suppling and fixing in position 15mm.diameter brass / C.P screw down tap / pillar tap / swan neck tap (heavy duty) of approved make conforming to I.S.specifications and quality including cost of shellac, thread etc.complying with standard specifications and including cutting and threading wherever necessary
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.
Provision for GST @ 18%
R MUTHUSAMY AND COMPANY
stage.html
html • 0.02 MB
finance_348960.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .