Loading…
Loading…
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
13 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
13 conditions · 2 needing a document upload
Not Applicable due to Advertised cost of tender is below 50 lakh.
Not Applicable due to Advertised cost of tender is below 50 lakh.
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Augmentation of 5 Watt Walkie Talkie and 25 Watt VHF system over Howrah Division.
SDSTE-WALKIE-VHF-HWH-25
SDSTE-WALKIE-VHF-HWH-25
Open
Works - General
6 Months
Howrah, West Bengal
₹0
₹97,000
13 Mar 2026
17 Feb 2026
27 Feb 2026
27 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 48,51,991.58 | ||
| — | — | — | Above/ 80800.00 Below/P | ||
| "Supply of Medium class GI pipes 50 mm dia (3.6 mm thickness) as per IS 1239 (Part 1): 2004 for use in ASM room and at any other location as decided by Site Engineer. It includes supply of all material required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges and sudden bends."Inspection: Consignee. | — | 200.00 | — | — | |
| — | — | — | Above/ 114900.00 Below/P | ||
| "Supply of Medium class GI pipes 40 mm dia as per IS standard It includes supply of all material required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges and sudden bends."Inspection: Consignee. | — | 600.00 | — | — | |
| — | — | — | Above/ 78400.00 Below/P | ||
| "Laying & Fixing of Medium class GI pipes with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work (if required) to protect the cables from sharp edges and sudden bends. (Installation be done as per concerned Railway site supervisor)" | — | 800.00 | — | — | |
| — | — | — | Above/ 942975.00 Below/P | ||
| "Supply, fixing and wiring of surge protection device in attachment plug module with replaceable surge protection for coaxial signal, interfaces N-connector plug/socket installed as surge protection between antenna and 25 W VHF sets, make- Phoenix Contact model CN-UB-280DC-SB- 2818148 or similar as per specifications. this includes mounting plate and reserve gas filled surge arrestor (one no.) with all required connectors/clamp for commissioning of SPD at site. Inspection: Consignee. (Installation be done as per concerned Railway site supervisor)" Inspection: RDSO/RITES if value of item in work more than 5 lakhs | — | 135.00 | — | — | |
| — | — | — | Above/ 835650.00 Below/P | ||
| "Installation, testing and mounting of G.P. antenna on a GI pipe which is to be fitted on the roof of equipment room and lightning arrestors also to be mounted on a GI pipe. All fixing materials to be supplied by the tenderer and left-over material to be returned to the railway store. (Antenna base should be made by cement concreting and GI pipe to be supported by suitable arrangement ) N.B. G.P. Antenna, GI pipe (40mm/50 mm dia) and lightning arrestor will be supplied by the railway. (Installation be done as per concerned Railway site supervisor)" | — | 135.00 | — | — | |
| — | — | — | Above/ 283770.00 Below/P | ||
| Installation, testing & commissioning of operating panel room VHF/SIMPLEX VHF base equipment, DCDC simplex VHF base equipment, DC-DC converter, buffer amplifier and laying of co- axial cable simplex VHF base equipment, DC-DC converter, buffer amplifier should be mounted on rack of suitable size and other fixing arrangement. (Installation be done as per concerned Railway site supervisor) | — | 135.00 | — | — | |
| — | — | — | Above/ 29975.58 Below/P | ||
| "Supply of Power Supply for Wireless Application, DC Output Current 15 Amps as per Annexure INSPECTION:CONSIGNEE" | — | 6.00 | — | — | |
| — | — | — | Above/ 57006.00 Below/P | ||
| Supply of 12V/110AH SMF battery as per annexure Inspection: Consignee. | — | 6.00 | — | — | |
| — | — | — | Above/ 201960.00 Below/P | ||
| "Supply of earth electrode mild steel galvanized, light class, IS:1239(PART-I)- 1979.earth electrode pipe should be with 3 mm thick, 50 mm dia and perforated(staggered),5 mm dia holes, 2 nos per 305 mm length with clamp of MS FLAT (galvanized) of size 35 mm x 6 mm (SPEC.NO.226 STD). Earth pipe should include CI threaded cap. Materials to be procured and designed as per CSTE/ER'S DRG.NO.SI/TYP/0097 or latest. Inspection: - BY RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh] " | — | 135.00 | — | — | |
| — | — | — | Above/ 122985.00 Below/P | ||
| "Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE/ER'S DRG. NO. SI/TYP/0097 or latest. Inspection: by Consignee." | — | 135.00 | — | — | |
| — | — | — | Above/ 156735.00 Below/P | ||
| "Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE/ER'S DRG. NO. SI/TYP/0097 or latest for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note: -all materials required to be arranged by the contractor except 2 core cable will be supplied by the railway. ( The earth electrode required to be connected with existing earthing as per direction of site supervisor)" | — | 135.00 | — | — | |
| — | — | — | Above/ 77085.00 Below/P | ||
| "Provision of cement concrete enclosure for earth electrodes as per DRG. NO. S&T/C36(NKG). This includes supply of all materials by the contractor duly inspected by consignee. " | — | 135.00 | — | — | |
| — | — | — | Above/ 1869750.00 Below/P | ||
| "Supply of 1 x 25 Sq.mm. (Green) multi strand copper power wire as per IS: 694:2010 or latest, 196 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.78 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer in- charge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 6750.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CheckListAnnexItoVIIIUPDATED_1.pdf
ATTACHMENT
AnnexureIX.pdf
ATTACHMENT
Annexure-X.pdf
ATTACHMENT
Annexure-XI_1.pdf
ATTACHMENT
AnnexureV.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
Annexure-VIA.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
GCC-2022-Updated-25.09.24.pdf
ATTACHMENT
VICINITYOFUNDERGROUNDCABLE-
ATTACHMENT
TermsofPayment.pdf
ATTACHMENT
LabourCessAddendumCorrigendumslipno.4.pdf Labour Cess
ATTACHMENT
ACS1.pdf
ATTACHMENT
ACS2.pdf
ATTACHMENT
ACS3.pdf
ATTACHMENT
ACS4.pdf
ATTACHMENT
ACS5.pdf
ATTACHMENT
ACS6.pdf
ATTACHMENT
ACS7.pdf
ATTACHMENT
ACS8.pdf
ATTACHMENT
ACS9.pdf
ATTACHMENT
ACS10.pdf
ATTACHMENT
Updatedtenderdocument_15.pdf
ATTACHMENT
AnnexVHFWT.pdf
ATTACHMENT
NewEarthing1.pdf
ATTACHMENT
JPO-CABLEDIGGINGWORK-VICINITYOFUNDERGROUNDCABLE-SRDSTESRDEN-C-240124.pdf
ATTACHMENT
LabourCessAddendumCorrigendumslipno.4.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .