Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC 327 328 III FLOOR INDRAPRASTH TOWER INDORE | INDORE | INDORE | MADHYA PRADESH | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.9 L+₹2 L (6.92%)Rejected-Finance 7TH FLOOR DN 12 SECTOR V SALT LAKE CITY KOLKATA 700091 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700091 | L2 | Rejected-Finance L2 | |
| 3 | L3₹34.7 L+₹5.8 L (20.0%)Rejected-Finance 184 187 TEMPLESTEPS BLOCK ANNASALAI LITTLEMOUNT CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
17 Sept 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
O/o The EE_KNED, PWDte, P-5, CIT Road, 2nd Floor, Moulali, Kolkata-700 014.
Electrical Installation work related to installation of main panel,EI work for LC, lift along with SITC of 10 passenger MRLlift at Gplus4 new building within the premises of Presidency University,College street campus-SITC of 2nos 10 passenger lifts.
2022_WBPWD_390578_2
WBPWD/EE/KNED/NIT-10 of 2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
Presidency University
Please refer Tender documents.
3 documents required · 3 mandatory
₹60,000
29 Nov 2022
18 Aug 2022
19 Sept 2022
19 Aug 2022
17 Sept 2022
23 Aug 2022
Amount
SITC of 10 passenger Automatic Lift (as per manufacturer design & as per detailed specification below conforming to IS) and putting into operation after final testing in the lift shaft complete with all accessories. Make: OTIS/ KONE/ SCHINDLER Type:- Machine Room Less Passenger Lift. Load: 10 (ten) Passenger/ 680 Kg. Control: Microprocessor based with AC variable voltage & variable frequency (VVVF). Machine:- Energy efficient machine, Gearless without Machine Room. MAP Floor Position: Topmost floor (TOP). Speed:- 01 Mtr./Sec. Floor Served:- G+4. Stops & Openings:- 5 stops & 5 openings, Single entrance car. Travel: 13.2 Mtr. Operation: Microprocessor based simplex full collective with or without attendant. Signals: Digital car position indicator, car travels direction indicator in car & at all landing with call registration indicator with braille Leveling accuracy ± 5mm (Micro leveling arrangement).
CAR Car inside:1200mm (W) x 1400mm (D) x 2200mm (H). Car Entrance: Clear Opening ..900 mm (W) x 2000 mm (H) protected with car door for Accessible India. Car Enclosure: Stainless Steel Sheet (20 SWG) with Hairline finish with hand rail, control switches along with braille. Handrail: Round Bend Handrail Silver brushed stainless steel at Rear Wall. Car Ceiling & Lighting : Stainless Steel with hairline finish with LED lighting and Fan Car Ventilation: Pressure fan with anodised aluminium grill. Car Flooring : Decorative granite flooring (As per direction of EIC and according to this Department's Order). Car Door: Stainless Steel Two panel Centre opening automatic door provided with V3F controlled door drive system. Landing Door: Stainless steel 7segment display Surface Mounted Silver brushed StSt Square, Surface Mounted with braille. Door Opening: Automatic power operated door with full length Photocell assembly light curtain sensor.
PROTECTIVE DEVICES & OTHER ACESSORIES ARD: Automatic rescue device complete with dry maintenance free batteries as required for automatic evacuation to the nearest floor in case of Power failure/ Single phasing/ others(Phase reversal protection and High Voltage protection). Overload Protection: Full loaded with overload protection. On overloading the lift, car will not start with door remaining open and give audio display indication. Emergency lighting in car: Battery operated emergency lighting in the lift car. Intercom system: Battery Operated intercom system in lift car, Machine Room & Control Room. Emergency Alarm: Battery operated alarm bell system in lift car and control room. Fireman switch: Fireman switch at main landing terminal. Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator. Main rope:- As per manufacturer's standard conforming to IS. Other Features: Call Registration LEDs.,OSG Electronic Switch.,Fire man drive.,Hand rail in rear side only.,1 hour fire rated at landing door.,Mechanical Manual Rescue Break Lever.,24*7 Cloud base monitoring system for maximum up time, Mechanical Lock arrangement for car door. Emergency Rescue Device with audio announcer, Three way intercom, Nudging Service, Attendant Service, Lift Announcer, Ring Lighting LED.
DIMENSION OF SHAFT & POWER SUPPLY Shaft Dimension: Available shaft Dimension 2300mm x 1900 mm. Pit Depth:1650 mm. Overhead: 4800 mm. Electric power supply: (i) Main Supply: AC 415 Volt 3 Phase, 50 Hz, terminated in machine room as per IS. (ii) Auxiliary Supply: Single-phase 220 V, 50 Hz. Note: i) Rate should be including with Minor civil works, wall / floor cutting for making holes, chiseling etc. and allied mending good the damages to the original finish with all necessary arrangements. ii) Necessary MS member e.g., angle iron, MS Channel, brackets etc. as required to be provided by the manufacturer.
SCHINDLER INDIA PRIVATE LIMITED
Otis Elevator Company(India)Limited
technical_777127.pdf
PDF • 0.73 MB
techsummary_777127.pdf
PDF • 0.73 MB
finance_777127.pdf
PDF • 0.73 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_777127.pdf
PDF • 0.46 MB
NIT_10_2ndCall_KONE.pdf
PDF • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .