Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 489 TRIMOORTI NAGAR DAMOH NAKA JABALPUR 482002 | JABALPUR | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.3 L+₹27,604.50 (6.90%)Rejected-AOC BEHIND BANK OF BARODA WARD NO 19 DHANPURI SHAHDOL 484114 | SHAHDOL | SHAHDOL | MADHYA PRADESH | 484114 | L2 | Rejected-AOC L2 | |
| 3 | L3₹5.1 L+₹1.1 L (27.1%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L3₹5.1 L+₹1.1 L (27.1%)Rejected-Finance M68 A VEENA NAGAR SUKHLIYA VILLAGE TOWN INDORE CITY INDORE INDORE MADHYA PRADESH 452010 INDIA | INDORE | MADHYA PRADESH | 452010 | L3 | Rejected-Finance L3 | |
| 5 | L4₹5.5 L+₹1.5 L (38.6%)Rejected-Finance BIRSINGHPUR | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | D N ENTERPRISES L4 | R.S. CONSTRUCTION L5 | M/S BRILLIANT ENGINEERING WORKS L2 | TERESA CONSTRUCTION L3 | VINAYAK ELECTRICAL ENGINEERS AND CONTRACTOR L3 | VIJAYSHREE CONSTRUCTION POWER L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Work contract for painting of HT < transformers and all BUS Duct OF Generator, Generator Transformers, Unit auxiliary transformer, Station transformers etc. of phase-1, SSTPP, MPPGCL, Dongalia | |||||||||
| 1.01Particular | |||||||||
| 1.10 | Painting & nomenclature of Generator transformers including radiator
Area Calculated
Area of transformer = 98sqmeter
Area of Cooler = 104sqmeter
Area of conservator = 48sqmeter
Total area of transformer = 250 sqmeter
No. of Generator transformer = 3 no.
Total area to be painted = 250x3 =750sqmeter | 750 | Sq.meter | 141.6 ₹1,06,200 | 108.56 ₹81,420 | 84.38 ₹63,285 Lowest | 100.3 ₹75,225 | 100.3 ₹75,225 | 84.96 ₹63,720 |
| 1.20 | Painting & nomenclature of Station transformer #2 including radiator
Area Calculated
Area of transformer = 118sqmeter
Area of Cooler = 108sqmeter
Area of conservator = 44sqmeter
Total area of transformer = 270 sqmeter | 270 | Sq.meter | 141.6 ₹38,232 | 108.56 ₹29,311.2 | 84.38 ₹22,782.6 Lowest | 100.3 ₹27,081 | 100.3 ₹27,081 | 84.96 ₹22,939.2 |
| 1.30 | Painting & nomenclature of Unit transformer including radiator
Area Calculated
Area of transformer = 90sqmeter
Area of Cooler = 76sqmeter
Area of conservator = 24sqmeter
Total area of transformer = 190 sqmeter
No. of Unit transformer = 4 no.
Total area to be painted = 190x2 =380 sqmeter | 380 | Sq.meter | 141.6 ₹53,808 | 108.56 ₹41,252.8 | 84.38 ₹32,064.4 Lowest | 100.3 ₹38,114 | 100.3 ₹38,114 | 84.96 ₹32,284.8 |
| 1.40 | Painting & nomenclature of VFD oil type transformer ESP area
Area Calculated
Area of transformer = 52.52sqmeter
No. of Dry type transformer = 4 no.
Total area to be painted = 52.52x4 =210 sq meter | 210 | Sq.meter | 141.6 ₹29,736 | 108.56 ₹22,797.6 | 84.38 ₹17,719.8 Lowest | 100.3 ₹21,063 | 100.3 ₹21,063 | 84.96 ₹17,841.6 |
| 1.50 | Painting of Bus ducts of GT, Generator , UAT & Station u
• UAT 2A to 2CA Bus duct :- 4340 sqfeet
• UAT 2B to 2CB Bus duct :- 4940 sqfeet
• Station 2 to OBB Bus duct :- 4280 sqfeet
• Station 2 to OCC Bus duct :- 5500 sqfeet
) | 3,455 | Sq.meter | 94.4 ₹3,26,152 | 110.92 ₹3,83,228.6 | 84.38 ₹2,91,532.9 | 100.3 ₹3,46,536.5 | 100.3 ₹3,46,536.5 | 76.12 ₹2,62,994.6 Lowest |
Tender Value
₹5.7 L
EMD Value
₹11,500
Closing Date
26 Jun 2023, 12:00 pmClosed
SE(WORKS)
o/o S.E.(Works) SSTPP, MPPGCL, Dongalia,IIIrd Floor Admin Building SSTPP
Work contract for painting of HT and LT transformers and all BUS Duct of Generator, Generator Transformers, Unit auxiliary transformer, Station transformers etc. of phase 1, SSTPP, MPPGCL, Dongalia
2023_MPPGC_261352_1
WT-1932
Open Tender
Miscellaneous Works
Lump-sum
365 days
SSTPP, MPPGCL, Dongalia
as per NIT
12 documents required · 12 mandatory
₹500
Yes
₹11,500
Yes
17 Oct 2025
16 May 2023
26 Jun 2023
16 May 2023
26 Jun 2023
16 May 2023
Work contract for painting of HT < transformers and all BUS Duct OF Generator, Generator Transformers, Unit auxiliary transformer, Station transformers etc. of phase-1, SSTPP, MPPGCL, Dongalia
Particular
Painting & nomenclature of Generator transformers including radiator Area Calculated Area of transformer = 98sqmeter Area of Cooler = 104sqmeter Area of conservator = 48sqmeter Total area of transformer = 250 sqmeter No. of Generator transformer = 3 no. Total area to be painted = 250x3 =750sqmeter
Painting & nomenclature of Station transformer #2 including radiator Area Calculated Area of transformer = 118sqmeter Area of Cooler = 108sqmeter Area of conservator = 44sqmeter Total area of transformer = 270 sqmeter
Painting & nomenclature of Unit transformer including radiator Area Calculated Area of transformer = 90sqmeter Area of Cooler = 76sqmeter Area of conservator = 24sqmeter Total area of transformer = 190 sqmeter No. of Unit transformer = 4 no. Total area to be painted = 190x2 =380 sqmeter
Painting & nomenclature of VFD oil type transformer ESP area Area Calculated Area of transformer = 52.52sqmeter No. of Dry type transformer = 4 no. Total area to be painted = 52.52x4 =210 sq meter
Painting of Bus ducts of GT, Generator , UAT & Station u • UAT 2A to 2CA Bus duct :- 4340 sqfeet • UAT 2B to 2CB Bus duct :- 4940 sqfeet • Station 2 to OBB Bus duct :- 4280 sqfeet • Station 2 to OCC Bus duct :- 5500 sqfeet )
M/S BRILLIANT ENGINEERING WORKS
TERESA CONSTRUCTION
VINAYAK ELECTRICAL ENGINEERS AND CONTRACTOR
D N ENTERPRISES
R.S. CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .