Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC | ₹4.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹4.5 Cr+₹2.2 L (0.50%)Rejected-AOC | ₹4.5 Cr+₹2.2 L (0.50%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical C O RANJIT KUMAR NARZARY VILL ANTHAIBARI PO PS BENGTOL DIST CHIRANG PIN 783394 | CHIRANG | ASSAM | 783394 | - | - | Rejected-Technical reject |
Tender Value
₹4.5 Cr
EMD Value
₹9 L
Closing Date
6 Feb 2021, 2:30 pmClosed
Sri Hriday Boro
O/o the Addl. Chief Engineer cum Director, PWD,Kokrajhar
Construction of SDBC road from Runikhata to Dantok road near Daimalu High School Via M Runikhata in Chirang District for Assam Govt. Goodwill Project for BTR District under SOPD G for the year 2020-21
2021_BTC_20483_1
No. ACE- 90/CHN/GWMP/2020-21/6
Open Tender
Civil Works – Roads
Item Rate
360 days
Chirang
Please refer Tender documents.
6 documents required · 6 mandatory
₹10,000
The Principal Secretary, BTC, Kokrajhar
₹9 L
Yes
23 Jul 2021
30 Jan 2021
6 Feb 2021
30 Jan 2021
6 Feb 2021
30 Jan 2021
30 Jan 2021 - 6 Feb 2021
Amount
(A) Road Work: Cleaning and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (i) By Manual means. (A) in area of non- thorny jungle.
Construction of Embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300.1 and 300.2 with lead upto 1000m as per Technical Specification Clause 301.5 (I) Private Land.
Construction of sub-grade and Earthen shoulders with approved material obtained from borrow pits with all lifts and leads, trandporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300.2 with a lead upto 1000m as per Technical specification clause 303.1 (i) Private land.
Construction of granular sub- base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with roravator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in place Method (ii) For Grading II Material.
Providing laying spreading and compacting stone aggregates of specific sizes fo water bound macadam specification inclueding spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill- up the interstices of coarseaggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means WBM Grading- II
Providing laying spreading and compacting stone aggregates of specific sizes fo water bound macadam soecification inclueding spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill- up the interstices of coarseaggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means WBM Grading- III
Providing and applying primer coat with bitumen emulsion (CSS-1) on prepared surface of granular base/WBM/WMM including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical specification Clause 502. (i) Medium Porosity.
Providing and applying take coat with Bitumen emulsion (CRS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Semi-Dense Bituminou Concrete (Providing and laying Semi- Dense Bituminous concrete with 100-120 THP batch type HMP produching an average ouput of 75 tonnes per hour using crushed aggregates of specific grading, premixed with bituminous binder @ 4.5 to 5% of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, level and alignment, rolling with smooth wheelled, vibratory and tendem roller to achieved the desired compaction as per MoSRT&H cl. no. 508. complete in all respect. B. (ii) for Grading - II (10 mm nominal size)
Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 × 75 × 6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 × 450 × 600, 600mm below ground level as per approved drawing and Technical Specification Clause 1701.
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm × 75mm × 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450mm × 450mm × 600mm, 600mm below ground level as per drawings and Technical Specification Clause 801. (ii) 60cm equilateral tringle
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm × 75mm × 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450mm × 450mm × 600mm, 600mm below ground level as per drawings and Technical Specification Clause 801. (iii) 60cm circular
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm × 75mm × 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450mm × 450mm × 600mm, 600mm below ground level as per drawings and Technical Specification Clause 801. (iv) 80 cm × 60 cm rectangular
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75mm × 75mm × 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450mm × 450mm × 600mm, 600mm below ground level as per drawings and Technical Specification Clause 801. (v) 60cm × 60cm Square
Construction of RCC guide post of 250mm dia M15 grade cast-in-situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2
Reinforced cement concrete M15 Grade kilometre stone/ local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703. ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 Grade kilometre stone/ local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703. iii) 200 m stone (precast)
Planting of Trees and their Maintenance for three Year (planting of trees by the road side (Avenue trees) in 0.60m dia holes, 1m deep dug in the ground, mixing the soil with decayed farm yard/ sludge mannure, planting the sapling, backfilling the trenches, watering, fixing the tree guatrd and maintaining the plants for three year,
(B) Construction RCC Box Culvert, size : 5.00 × 5.00m, 5 cell, 1 No Earth work in excavation of foundation for structures as per drawing and technical specification Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50m, dressing of sides and bottom and backfilling in tranches with excavation material. i) Ordinary Soil
Sand Filling in foundation trenches as per drawing and Technical Specification 305.3.9
PCC 1:3:6 in foundation providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. A. With Crushed Stone : i) PCC Grade M10 (i) Nominal Mix 1:3:6
PCC 1:2:4 in foundation providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. A. With Crushed Stone : iii) PCC Grade M20 (i) Nominal Mix 1:2:4
Plain/ Reinforced cement concrete in sub- structure complete as per drewing and technical specifications Clause 802, 804, 805, 806, 807, 1202 & 1204. A. With Crushed Stone : iv) RCC Grade M25 (i) Height up to 5m
Providing & Laying Reinforced Cement Concrete in superstructure complete as per drawing and technical specification Clause 800, 1205.4 & 1205.5 A. With Crudhes stones: (iv) RCC GRADE M25 (a) Height up to 5m
Construction of RCC railing of M25 grade, cast-in-situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000mm as per drawing and technical specification Clause 800, 900 and 1208.3
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/ RINL) in sub structure complete as per drawings and technical specifications Clause 1002, 1005, 1010 & 1202.
Supplying, fitting and placing TMTTMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/ RINL) in super structure complete as per drawings and technical specifications Clause 1002, 1010 & 1202.
Providing and laying concrete wearing course M30 Grade including reinforcement complete as per drawing and technical specification Clause 800 and 1206.3 A. With Crushed stone :
Providing weepholes in brick/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of structures with slope of 1(V) : 20(H) towards drawing force complete as per drawing and technical specification Clause 614, 709, 1204.3.7
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification Clause 1204.3.8 A. Granular Materials
Providing and laying curtain walls complete as per drawing and Technical Specification Clause 1304 iii) Cement concrete grade M10
Drainage spouts complete as per drawing and technical specification Clause 1209
Construction of flexible apron 1m thick comprising of loose stone boulders weighing not less than 25 kg beyond curtain wall.
Providing pressure relief pipes 100mm dia in bottom slab of box cell on a filter media base of 500mm × 500mm as per drawing and technical specification Cl. 1205.5.7
P.C.C. M30 ordinary grade (1:2.5:5) levelling corse below approach slab complete as per drawing and technical specification etc (A) With crushed stone (I) Nominal Mix.
Reinforced cement concrete M25 grade Approach Slab including reinforcement and formwork complete as per drawing and technical specification etc. (A) With Crushed stone
Painting two coats including primer coat after filling the surface with synthetic enamal paint I all shades on new, plastered/ concrete surfaces per drawing and technical specification clause 1701
(C) Construction RCC Box Cell Culvert. size : 3.00m × 3.00m, 2 cell, 1 No Earth work in excavation of foundation for structures as per drawing and technical specification Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleteriors material and disposal up to a lead of 50m, dressing of sides and bottom and backfilling in tranches with excavated suitable material. I. Ordinary Soil (i) upto 3.00m depth
Sand Filling in foundation trenches as per drawing and Technical Specification 305.3.9
PCC 1:3:6 in foundation providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. A. With Crushed Stone : i) PCC Grade M10 (i) Nominal Mix 1:3:6
PCC 1:2:4 in foundation providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specification Clause 802, 803, 1202 & 1203 A. With Crushed stone: iii) PCC Grade M20 (i) Nominal Mix 1:2:4
Plain/ Reinforced cement concrete in sub structure complete as per drawing and technical specification Clause 802, 804, 806, 807, 1202 & 1204. A. With Crushed stone: IV. RCC GRADE M25 (i) Height up to 5m
Providing & Laying Reinforced Cement Concrete in superstructure complete as per drawing and technical specification Clause 800, 1205.4 & 1205.5 A. With Crushed stone: iv. RCC GRADE M25 (i) Height up to 5m
Construction of RCC railing M25 grade, cast-in-situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre to centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specification Clause 800,900 and 1208.3
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/ RINL) in sub structure complete as per drawings and technical specifications Clause 1002, 1005, 1010 & 1202.
Supplying, fitting and placing TMTTMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/ RINL) in super structure complete as per drawings and technical specifications Clause 1002, 1010 & 1202.
Providing and laying concrete wearing course M30 Grade including reinforcement complete as per drawing and technical specification Clause 800 and 1206.3 B. With Natural Gravel
Providing weepholes in brick/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of structures with slope of 1(V) : 20(H) towards drawing force complete as per drawing and technical specification Clause 614, 709, 1204.3.7
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification Clause 1204.3.8 A. Granular Materials
Providing and laying curtain walls complete as per drawing and Technical Specification Clause 1304 iii) Cement concrete grade M10
Drainage spouts complete as per drawing and technical specification Clause 1209
P.C.C. M15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specification clause 800 and 1211 (A) With Crushed stone (i) Nominal Mix (1:2.5:5)
Reinforced cement concrete M25 grade Approach Slab including reinforcement and formwork complete as per drawing and technical specification clause 800 and 1211(A) With Crushed Stone
Construction of flexible apron 1m thick comprising of loose stone boulders weighing not less than 25 kg beyond curtain wall.
Painting two coats including primer coat after filling the surface with synthetic enamal paint I all shades on new, plastered/ concrete surfaces per drawing and technical specification clause 1701
(D) Construction RCC Box Cell Culvert. size : 2.00m × 2.00m, 1 cell, 1 No Earth work in excavation of foundation for structures as per drawing and technical specification Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50m, dressing of sides and bottom and backfilling in tranches with excavation material. i) Ordinary Soil (i) upto 3.00 m depth
Sand Filling in foundation trenches as per drawing and Technical Specification 305.3.9
PCC 1:3:6 in foundation providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. A. With Crushed Stone : i) PCC Grade M10 (i) Nominal Mix 1:3:6
PCC 1:2:4 in foundation providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specification Clause 802, 803, 1202 & 1203 A. With Crushed stone: iii) PCC Grade M20 (i) Nominal Mix 1:2:4
Plain/ Reinforced cement concrete in sub structure complete as per drawing and technical specification Clause 802, 804, 806, 807, 1202 & 1204. A. With Crushed stone: IV. RCC GRADE M25 (i) Height up to 5m
Providing & Laying Reinforced Cement Concrete in superstructure complete as per drawing and technical specification Clause 800, 1205.4 & 1205.5 A. With Crudhes stones: (iv) RCC GRADE M25 (a) Height up to 5m
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/ RINL) in sub structure complete as per drawings and technical specifications Clause 1002, 1005, 1010 & 1202.
Supplying, fitting and placing TMTTMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/ RINL) in super structure complete as per drawings and technical specifications Clause 1002, 1010 & 1202.
Providing and laying concrete wearing course M30 Grade including reinforcement complete as per drawing and technical specification Clause 800 and 1206.3 B. With Natural Gravel
Providing weepholes in brick/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of structures with slope of 1(V) : 20(H) towards drawing force complete as per drawing and technical specification Clause 614, 709, 1204.3.7
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification Clause 1204.3.8 A. Granular Materials
Providing and laying curtain walls complete as per drawing and Technical Specification Clause 1304 iii) Cement concrete grade M10
Construction of flexible apron 1m thick comprising of loose stone boulders weighing not less than 25 kg beyond curtain wall.
Painting two coats including primer coat after filling the surface with synthetic enamal paint I all shades on new, plastered/ concrete surfaces per drawing and technical specification clause 1701
(E) Construction RCC Box Cell Culvert. size : 1.00m × 1.00m, 1 cell, 2 Nos. Earth work in excavation of foundation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50m, dressing of sides and bottom and backfilling in tranches with excavated suitable material.
Sand Filling in foundation trenches as per drawing and Technical Specification 305.3.9
PCC 1:3:6 in foundation. Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. A. With Crushed Stone : i) PCC Grade M10 (i) Nominal Mix 1:3:6
PCC 1:2:4 in foundation. Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. A. With Crushed Stone : iii). PCC Grade M20 (i) Nominal Mix 1:2:4
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications Clauses 802, 804, 805, 806, 807, 1202 &1204. A. With Crushed stone IV. RCC GRADE M25 (i) Height up to 5m
Providing & Laying Reinforced Cement Concrete in superstructure complete as per drawing and technical specifications Clauses 800, 1205.4 & 1205.5 A. With Crushed stone IV. RCC GRADE M25 (i) Height up to 5m
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/RINL) in sub structure complete as per drawings and technical specifications Clauses 1002, 1005, 1010 & 1202.
Supplying, fitting and placing TMTTMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/RINL) in super structure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202.
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A. With Crushed stone :
Providing weepholes in brick masonry/ stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of structures with slope of 1(V) : 20(H) towards drawing force complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Back filling behind abutment, wing wall and return wall complete as per drawings and technical specification Clause 1204.3.8
Providing and laying curtain walls complete as per drawing and Technical Specifications Clause 1304. iii)Cement concrete grade M10
Painting two coats including primer coat after filling the surface with synthetic enamal paint I all shades on new, plastered/ concretes surfaces as per drawing and technical specification clause 1701.
(F) Protection Work: Providing and laying of boulder apron laid in wire crates with 4mm dia GI wire conforming to IS:280 and IS:4826 in 100mm × 100mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25kg each as per drawing and technical specification Clause 1301
Providing and laying pitching on slope laid over prepared filter media as per drawing and technical specifications Clause 1302
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Dismantling of Structure. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonary, cement concrete, wood work, steel work, including T & P and scaffolding where necessary, sorting the dismantled material, disposal of unsericeable material and stacking the serviceable materials with all lifts and lead of 1000m as per Technical Specification Clause 202/ (C) Reinforced Cement Concrete
Making 120cm wide bamboo foot bridge with 100mm Bholuka or Barua Bamboo posts driven 120cm to 180cm underground 3 nos. in each row and rows being 3m apart bholuka or Barua bamboo dham placed over the posts and tied with cane or wire, Bholuka or barua bamboo struts in each row both up and down stream, jati bamboo long gorhs closely packed and tied with dham. Single layer of mat placed over 75mm thick brush wood and tied with bholuka or Barua banboo rail stand fixed in one side of the bridge etc. complete.
Construction of cold weather Bamboo bridge overall width of 3.70m and clear road way 3m wirh jungle wood post 20cm to 25cm dia 5nos. In each rows and rows being 2.1m. apart except for the navigable span which should be 3m. Post to be driven at least 180cm or more below ground level including providing 20cm to 25cm centre to centre and placed over 20cm dia, jungle wood dham, 15cm dia. jungle wood bracing collar fixed by bolts and nuts, straps etc. mature bholuka Bamboo cross groth all closely packed and tied 75cm wide track way made from 38mm thick 1st class local plank fixed on 75mm×100mm first class local wood battens 120cm apart and 3 lines of jati bamboo horizontal railing fixed in bholuka bamboo post placed at 210cm apart and white washed including all necessary nuts and bolts, coir ropes, struts, nails etc. complete with a layer of brushwood to exposed portion out-side trackway with earth topping complete as per direction of the department.
KAMALA KANTA KHAKLARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .