Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.7 L+₹4,218.50 (0.33%)Rejected-Finance 21 9TH MAIN 4TH CROSS GOWDAKEHOLA BAGALAKUNTE NAGASANDRA POST BANGALORE 560073 | BENGALURU URBAN | KARNATAKA | 560073 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹12.9 L+₹20,194.50 (1.59%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹12.9 L+₹25,155.50 (1.98%)Rejected-Finance NO 131 5TH CROSS PASCHIM COUNTY MEDARAHALLI CHIKKABANAVRA POST BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹13.0 L+₹31,994.50 (2.52%)Rejected-Finance NO 92 KUVEMPUNAGAR 2ND STAGE JALAHALLI EAST BANGALORE 560 014 | 560014 | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹29,300
Closing Date
29 Sept 2020, 6:00 pmClosed
CWE AF SOUTH BANGALORE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF BULK RATION STORE IN 15 T MESS AT ETI AF STATION JALAHALLI BANGALORE
2020_MES_374071_1
85187
Open Tender
Civil Works
Item Rate
270 days
Jalahalli Bangalore
As per Tender documents
7 documents required · 7 mandatory
₹500
GE (M) (AF) Jalahalli
₹29,300
Yes
22 Dec 2020
2 Sept 2020
1 Oct 2020
2 Sept 2020
29 Sept 2020
17 Sept 2020
3 Sept 2020 - 14 Sept 2020
Amount
Excavating over areas, nexc 1.5 m deep and getting out any type of soil.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m deep for foundation etc., and getting out in hard/dense soil.
M&L PCC 1:4:8 type D-2 (using 40mm graded agg) in foundation, filling and mass concrete.
M&L MS bars 10mm dia TMT & over deformed & twisted bars cut to length ,bent to shape required incl cranking , bending , hooking, for lintel and binding with MS wire not less than 0.9 mm dia or securing with clips.
All as per Serial Item No. 4 but 5mm dia and over up to and including 10 mm dia as in stirrups and spacers.
M&L RCC type M25 20 mm graded stone aggregate design mix)as in foundations, plinth beam etc completed all as specified and directed.
M&L RCC type M25 20 mm graded stone aggregate design mix)as in Columns, pillars, piers, posts and struts etc completed all as specified and directed.
Supply only integral water proofing compound of approved make.
M&L for RCC type M25 20 mm graded stone aggregate design mix)as in beams, cantilevers, bressummers, lintels over 1.5 m span all as specified and directed.
M&L for RCC type B1 1:2:4, 20 mm graded stone aggregate (nominal mix) in Chajjas all as specified and directed.
M&L for Formwork to sides of concrete foundation,footing,based of columns,raft and raft beam,sides and soffits (if any) of foundation and plinth beams,and similar works,vertical or to batter rough finished flate surface of concrete all as specified and directed.
M&L for Formwork to flat sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.and finished fair surfaces all as directed.
M&L for Formwork to chullah hoods, chajjas,troughs and similar items including edges all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, square/rectangular columns and stanchions all as specified and directed.
M&L pre-cast PCC 1:3:6 type C1 (20 mm graded agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting in soft /loose soil all as specified and directed.
M&L for Hardcore of guage n exc 63mm deposited spread and levelled in layers not exc 15cm thick watered and rammed to a true surfaces complete all as specified.
M&L PCC 1:4:8 type D2 using 40 mm graded agg as in flooring 100mm thick complete all as specified and directed.
M&L PCC 1:3:6 type C2 using 40 mm graded agg as in flooring 75mm thick as in plinth protection finished fair and even all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation for laying interlocking tiles complete all as specified and directed.
M&L machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and pigment and setting with surface vibrator all as directed by Engr-in-charge..
M&L 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 and finishing the surfaces even and smooth without using extra cement all as specified and directed.
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finishing the surfaces even and smooth without using extra cement all as specified and directed.
M&L preparation of plastered surfaces of walls and applying two coats of cement base paint over primer alkali resistance on new surfaces all as specified and directed.
M&L preparation of plastered surfaces of walls and applying two coats ofoil bound distemper over primer alkali resistance on new surfaces all as specified and directed.
M&L for applying three coats of white wash on new surfaes of wall as directed incl preparation of the surfaces all as specified and directed.
M/L for steel windows with side hung shutters incl hinging devices and steel peg stay , complete with glazing bars dovetailed or welded all as specified and directed.
S &F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane and all as specified and directed.
S&F of Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 and necessary welding complete all as specified and directed.
M&L for preparation of new steel surface and appling two coat of synthetic enamel paint on new steel surface over a coat of red oxide all as specified and directed.
S&F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F of Plain, 0.56mm thick Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) all as specified and directed.
M&L for 20 mm thick screed bed in cement mortar 1:4 for laying floor finishes under floor and all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L MS bar 6 to 8 mm dia TMT & over deformed & twisted bars cut to length ,bent to shape required incl cranking , bending , hooking, for lintel and binding with MS wire not less than 0.9 mm dia or securing with clips all as specified and directed.
M/L reinforced cement concrete (1:2:4)typeB-1 using 20mm graded stone aggregate as in cantilevers and finishing exposed surfaces fair & even all as specified.
Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
S&F of Steel rolling shutters, thickness of lath 1.25 mm with out ball bearing,gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete all as specified and directed.
S&F of Safety lever locks mild steel with 4 levers for rolling shutters all as specified and directed.
S&F of Ball bearing for rolling shutters all as specified and directed.
M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) as anti termite treatment all as specified and directed.
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface as anti termite treatment all as specified and directed.
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area as anti termite treatment all as specified and directed.
M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall as anti termite treatment all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed at a level not exc 1.50 m above starting point all as specified and directed.
Returning fillin in, including spreading, leveling,watering and well ramming in layers n exc 25cm all as specified and directed.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm on surface including provn of pressed steel terminal box of suitable size with 3 mm thick plastic laminated sheet cover for mounting switch, socket along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all as specified and directed.
(a) One light point controlled by one switch one way 5 Amps
(b) One exhaust fan point controlled by one switch one way 5 Amps
(c) All as per item No 1 above but one switch socket combination 15 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm
S&F switch piano flush type single pole one way switch 5 Amps
S&F switch socket combination multipurpose 5 A/16 Amps,5 in1,flush type.
S&F ceiling rose, 3 phase/PVC/Poly carbonate, isolated body all as directed.
Supply & fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 20 Watt. Make : Havells. Cat No-LHEXACP7IN1W020 or equivelent in WIPRO/CG/Bajaj/Philips
Supply and fix of 15 watts, 230 V LED light fitting for Building security LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with bracket & clamps Make : Havells Cat Part No. ENDURAPEARLSL 15WLED757 SASYTOPC or equivalent make of Philips/OSRM/KRIPA.
S&F Exhaust fan 450 mm sweep, 230/240 volt AC single phase 410W, heavy duty 1400 RPM, along with louers adn connecting up including provision of 3 core flexible cable of size 0.5 sqmm from ceiling rose to connector grounting bollts of suitable size, accessaries Make : Bajaj, code 70064. including cutting hole as per site requirement suitable for fixing exhaust fan and make good the surface to match with existing surface all as specified and directed.
S&F in repair, sheet metal enclosure distribution box suitable for MCB'S 8 way SPN with 200 Amps rated bus bar , 240 volts double door complete including connecting up all as specified and making good disturbed surface all as specified and directed.
S&F in repair MCB Single pole, 240 volts 5 to 32 Amps 10 KA rupturing capacity, C series all as specified and directed.
S&F in repair MCB Single pole & neutral 240volts 5 to 32 Amps, 10KA rupturing capacity, C series all as specified and directed.
Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of the plate at a depth not less than 1.5 m below ground level, connected to and including GI wire 4mm dia with GI protection pipe 15 mm dia light grade connected to and including by means of GI bolts, nuts, check nuts and washers all as shown in electric plate No 3 of SSR part I including neccesary excavation earth work in any strata. PCC 1:3:6, type C2 chamber, RCC 1:2:4, Type B1 cover slab 50mm thick with 8mm TMT bar 100mm centre to centre including 8mm dia handle and watering pipe medium grade 20mm bore, funnel, wire mesh, etc and testing on completion all as specified and directed.
Supply and lay under ground cable XLPE insulated screened PVC bedded, galvanized steel strip of wire armored, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor of size 6 sq mm x 2 core.
M & L for Excavation in trenches hard and dence soil not Exe. 1.5m wide and not Exe. 1.5m in depth for laying cable and getting out in hard/ dense soil.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soil all as specified.
Supply and spread dry river sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming all as specified and directed Note:- For the purpose of payment the punned thickness only measured.
Supply and lay un-reinforced precast concrete cable cover, class LV, Type-2, size 250mm x 150mm x 40 mm for cable protection all as specified and directed.
Removing the excavated soil to a distance not exe 50m and depositing where directed at a level n exe 1.5m above the starting point all as directed.
M&L for plain cement concrete type D2 1:4:8 in 40 mm graded stone aggregate for making good disturbed surface etc. all as specified.
Supply and fixing GI tubing light grade 40 mm dia for cable protection fixed along with steel tubular pole / RCC pole/ laying in ground including necessary clamp, nut, bolt, washers etc. all as directed at site.
SRI MAHALAKSHMI CONSTRUCTIONS
SREE BUILDERS
Aditya Associates
BYRAVESHWARA CONSTUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .