Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹54.0 LAccepted-AOC | ₹54.0 L | 1 | Accepted-AOC Lowest Bidder |
| 2 | 2₹55.0 L+₹1.1 L (2.00%)Rejected-Finance | ₹55.0 L+₹1.1 L (2.00%) | 2 | Rejected-Finance 2nd Lowest Bidder |
Tender Value
₹54.0 L
EMD Value
₹1.1 L
Closing Date
16 Mar 2026, 2:00 pmClosed
EEE EWD Dumka
Dumka
S/R to E.I. in M.S.D.P. building and Administrative building in the campus of K.K.M. College at Pakur.
2026_ENRGY_111053_2
Energy/EWD/Dumka/31/2025-26
Open Tender
Electrical Works
Percentage
60 days
Dumka
Please refer Tender documents.
8 documents required · 8 mandatory
₹10,000
₹1.1 L
Yes
16 Jun 2026
9 Mar 2026
17 Mar 2026
9 Mar 2026
16 Mar 2026
10 Mar 2026
Part - "A"
S/R to E.I. in M.S.D.P. building in the campus of K.K.M. College at Pakur.
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular switch, modular plate suitable GI box etc as required
a) Group - C
Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc as required.
Wiring for circuit/ submain wiring along with earh wire with the following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required
a) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire (For light circuit)
b) 1 x 1.5 sq mm ( For inverter wiring)
c) 2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire (For light Submain)
d) 2 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire (For Power Submain)
Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings)
Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings)
S/F following way single pole neutral, sheet MCB distribution board, 240 volts on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gtand plate, interconnections, Phosphatized and powder painted including earthing etc as reqd. (But without MCB/RCCB/Isolator)
a) 2 way double door
b) 4 way double door
c) 6 way double door
d) 8 way double door
Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “B” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required.
S/F following 240 volts, 'C' series/"B" series miniature circuit breaker suritable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as reqd.
a) 32 amps, MCB
b) 63 amps, DP MCB
Supplying and fixing of following sizes of PVC/G.I box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
a) 72 mm x 146mm x 48mm deep/ (4" x 7")
b) 170 mm x 221mm x 48mm deep/ (8" x 10")
S/F stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
S/F modular type AC Starter switch for single phase 230V/50Hz of capacity 20/25amp
S/F 1 or 2 module (78mm x 78mm x 45mm) with modular base and cover plate (For A.C Starter)
S/F 2 pin 5 amp. Ceiling rose on the existing junction box/ wooden block including connection etc. as required .
Supplying and fixing Batten / Angle holder including connection etc as required .
S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required.
a) 20/22 W LED Tube light
S/F 9/10Watt LED Bulb
Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required.
a) 1200mm (48") Ceiling Fan
S/F 12'' (300mm) metal exaust fan .
S.I.T.C of following rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required
a) 90/100W LED Street light
Supplying and laying of XLPE indulated PVC sheathed aluminium cable working voltage upto and including 1100 volts. As per IS:7098, part-1) of following
a) 2 core 6 sq. mm (For Building light)
b) 4 core 16 sq. mm (From main panel to sub panel for light & Computer)
c) 3.5 core 25 sq. mm (From main panel to sub panel for power & A.C )
d) 3.5 core 35 sq. mm (From administrative building main panel to MSDP building main Panel for main line)
e) 3.5 core 25 sq. mm (From main panel to sub panel for power & A.C Building light)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm directr in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35 sq mm but not exceeding 95 sq mm direct in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering.
6 sq mm aluminium lugs
16 sq mm aluminium lugs
25 sq mm aluminium lugs
35 sq mm aluminium lugs
50 sq mm aluminium lugs
Supplying and fixing cable junction box make (Sintex/Hensel/or equivalent. (With 6 amp sp MCb)
65mm dia, GI bend medium class G.I. pipe cable laying in road crossing
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required.
fabricaton and installation of cubical panel with following accessories made of 16 SWG MS sheet painted with one coat steel primer and two coat power spray painting with approved shade makin PCC Plinth and foundation including fitting/ fixing / connection & transportation up to work site, labour charge etc all complete.
a) 25-100 amps, MCCB 10 KA fixed thermal setting (incoming) = 1 Nos
b) LED Indecator lamp R/Y/B/G = 3 Nos
c) 25mm x 5mm copper strips (1.15 kg/mtr) = 6 Kg
fabricaton and installation of cubical panel with following accessories made of 16 SWG MS sheet painted with one coat steel primer and two coat power spray painting with approved shade makin PCC Plinth and foundation including fitting/ fixing / connection & transportation up to work site, labour charge etc all complete.
a) 25-100 amps, MCCB 10 KA fixed thermal setting (Outgoing) = 4 Nos
b) 100 amps, MCCB 16 KA fixed thermal setting (Main / generator) line incoming.) 1 Nos.
c) 150/160 amp, MCCB 35 KA, fixed thermal setting (Main line Incoming.) 1 Nos.
d) Digital Volt Mtr. (0-500Volt)- 3 phase class 0.5 = 2 Nos.
e) Digital AMP Mtr. (0-500AMP)- 3 phase class 0.5 = 2 Nos.
f) C.T. Coil of C.T. Ratio 300/5 = 6 Nos.
g) LED Indecator lam R/Y/B/G = 6 Nos.
h) 25mm x 5mm copper strips (1.15 kg/mtr) = 35 kg
Part - "B"
S/R to E.I. in M.S.D.P. building in the campus of K.K.M. College at Pakur.
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular switch, modular plate suitable GI box etc as required
a) Group - C
Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc as required.
Wiring for circuit/ submain wiring along with earh wire with the following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required
a) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire (For light circuit)
b) 1 x 1.5 sq mm ( For inverter wiring)
c) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire (Forcomputer board wiring)
d) 2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire (For light Submain)
e) 2 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire (For Power Submain)
S/F a compact unit made of 8/9 Module G.I./PVC box with 8/9 Module cover plate in front of fixed with 2 nos of 5/6 amps modular type switch and socket and one number 15/16 amps, modular type switch socket well connected with suitable wire, earthing etc as reqd. Name as computer board.
a) 8/9 Mod box with plate - 1 Nos @ 288 288.00
b) 5/6 Amp switches - 2 Nos @ 67.00 = 134.00
c) 5/6 Amp socket 2 Nos @ 88 = 176
d) 15/16 Amp socket - 1 Nos@ 145.00 145.00
e) 15/16 Amp switches - 1 Nos@ 102.00 = 102.00
Total 845.00
Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required
Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required
S/F following way single pole neutral, sheet MCB distribution board, 240 volts on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gtand plate, interconnections, Phosphatized and powder painted including earthing etc as reqd. (But without MCB/RCCB/Isolator)
a) 2 way double door
b) 4 way double door
c) 6 way double door
Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “B” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required.
S/F following 240 volts, 'C' series/"B" series miniature circuit breaker suritable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as reqd.
a) 32 amps, MCB
b) 63 amps, DP MCB
Supplying and fixing of following sizes of PVC/G.I box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
a) 72 mm x 146mm x 48mm deep/ (4" x 7")
b) 170 mm x 221mm x 48mm deep/ (8" x 10")
S/F stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
S/F modular type AC Starter switch for single phase 230V/50Hz of capacity 20/25amp
S/F 1 or 2 module (78mm x 78mm x 45mm) with modular base and cover plate (For A.C Starter)
S/F 2 pin 5 amp. Ceiling rose on the existing junction box/ wooden block including connection etc. as required .
Supplying and fixing Batten / Angle holder including connection etc as required .
S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required.
a) 20/22 W LED Tube light
S/F 9/10Watt LED Bulb
Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required.
a) 1200mm (48") Ceiling Fan
S/F 12" (300mm) metal exahaust fan
S/F 16" (1200") wall mounted fan
S.I.T.C of following rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required
a) 90/100W LED Street light
Supplying and laying of XLPE indulated PVC sheathed aluminium cable working voltage upto and including 1100 volts. As per IS:7098, part-1) of following
a) 2 core 6 sq. mm (For Building light)
b) 4 core 16 sq. mm (From main panel to sub panel for light & Computer)
c) 3.5 core 25 sq. mm (From main panel to sub panel for power & A.C Building light)
d) 3.5 core 70 sq. mm (From Generator to Main line)
e) 3.5 core 240 Sq mm (From transformer to main panel)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35 sq mm but not exceeding 95 sq mm direct in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 185 sq mm but not exceeding 400 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
6 sq mm aluminium lugs
16 sq mm aluminium lugs
25 sq mm aluminium lugs
35 sq mm aluminium lugs
70 sq mm aluminium lugs
120 sq mm aluminium lugs
240 sq mm aluminium lugs
Supplying and fixing cable junction box make (Sintex/Hensel/or equivalent. (With 6 amp sp MCb)
65mm dia, GI bend medium class G.I. pipe cable laying in road crossing
80mm dia Earthing Electrode 2mtr. Length / 80mm dia Earthing Electrode 3mtr. Length / 50mm dia Earthing Electrode 2mtr. Length/50mm dia Earthing Electrode 3mtr. Length & Backfill Compound chemical 4 Bag(per bag 25 KG)
Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required.
fabricaton and installation of cubical panel with following accessories made of 16 SWG MS sheet painted with one coat steel primer and two coat power spray painting with approved shade makin PCC Plinth and foundation including fitting/ fixing / connection & transportation up to work site, labour charge etc all complete.
a) 25-100 amps, MCCB 10 KA fixed thermal setting (incoming) = 1 Nos
b) LED Indecator lamp R/Y/B/G = 3 Nos
c) 25mm x 5mm copper strips (1.15 kg/mtr) = 6 Kg
fabricaton and installation of cubical panel with following accessories made of 16 SWG MS sheet painted with one coat steel primer and two coat power spray painting with approved shade makin PCC Plinth and foundation including fitting/ fixing / connection & transportation up to work site, labour charge etc all complete.
a) 25-100 amps, MCCB 10 KA fixed thermal setting (Outgoing) = 8 Nos
b) 100 amps, MCCB 16 KA fixed thermal setting (Main / generator) line incoming.) 8 Nos.
c) 150/160 amp, MCCB 35 KA, fixed thermal setting (Generator line Incoming.) 1 Nos.
d) 250 amp, MCCB 35 KA, fixed thermal setting (Solar line incoming) 1 Nos.
e) 400 amp, MCCB 35 KA, Adjustable thernmal setting (Main line incoming) = 1 Nos.
f) 200 amps, 4 pole changeover. = 1 Nos.
g) 320 amp, 4 pole changeover. = 1 Nos.
h) Digital Volt Mtr. (0-500Volt)-3 phase class 0.5 = 2 Nos.
i) Digital AMP Mtr. (0-500AMP)- 3 phase class 0.5 = 2 Nos.
j) C.T. Coil of C.T. Ratio 300/5 = 6 Nos.
k) LED Indecator lam R/Y/B/G = 6 Nos.
l) 25mm x 5mm copper strips (1.15 kg/mtr) = 60 Kg
m) 50mm x 5mm copper strips (2.30 kg/mtr) = 35 kg
CGST@9%(mailto:CGST@9%塹ᴻ䡿ⲯ嶂藄挧ꮥ)
SGST@9%(mailto:SGST@9%塹ᴻ䡿ⲯ嶂藄挧ꮥ)
Labour Cess @1%
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
BOQ_150049.xls
BOQ • 0.37 MB
F2.pdf
Tender Documents • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .