Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.3 L+₹20,485.60 (4.06%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹5.4 L+₹34,737.40 (6.88%)Rejected-Finance VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹5.6 L+₹57,713 (11.4%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹5.7 L+₹68,433.20 (13.6%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
6 Feb 2021, 6:00 pmClosed
AGE(I) Dalhousie
AGE(I) Dalhousie PIN 176305
REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY DISTRIBUTION LINES AND CERTAIN CONNECTED WORKS AT ZONE A AREA AT DALHOUSIE
2021_MES_410819_1
AGE (I)/D-60/20-21
Open Tender
Construction Works
Item Rate
180 days
Dalhousie
Please refer Tender documents.
8 documents required · 8 mandatory
₹300
Yes
AGE(I) Dalhousie
₹10,000
Yes
AGE(I) Dalhousie
30 Mar 2021
8 Jan 2021
8 Feb 2021
8 Jan 2021
6 Feb 2021
23 Jan 2021
8 Jan 2021 - 15 Jan 2021
15 Jan 2021
Amount
M&L for draining out water from semi undergroung water storage tank of capacity 41000 Gallon scraping out bleachin residual, sediments, sand, fungues scaling etc from inside, bottom and wall of water storage tank with the help of wire brush, steel Patti broom and jute bags and taking out same from the water storage tank and throwing at a distance not less than 25 mtr away from the water storage tank, cleaning inside the water storage tank and then washing and flushing out with fresh water till the entire satisfaction of Engr-in-Charge and writing the date of cleaning on water tank wall with black/white enameld paint complete all as specified and directed by Engineer-in-Charge. (At Ticca Area - 02 Nos)
All as per above srl Item No. 1 here in before but 20000 Galon Capacity complete all as directed by Engineer-in-Charge. (At Ticca Area - 02 Nos & Gemini area -01 No)
All as per above srl Item No. 1 here in before but 10000 Galon Capacity complete all as directed by Engineer-in-Charge. (At Ticca Area - 01 Nos)
All as per above srl Item No. 1 here in before but 10000 Ltr Capacity PVC tank including changing of broken tank cover with locking arrangement complete all as specified and directed by Engineer-in-Charge. (At Ticca Area - 03 Nos)
Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in Hard/dense soil including taking out and laying of GI pipe complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point.
M&L for Taking up or down galvanized steel tubing with complete fitting for refixing or removal of worksite complete all as specified and directed by Engineer-in-charge.
(a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 32mm bore
(e) 40mm bore
(f) 50mm bore
(g) 80mm bore
(h) 100mm bore
M&L refixing old steel GI Tubing obtained against item No 8 after complete cleaning of all rusted and mudy particals inside the GI Tubing and refixing /relaying same worksite on the wall,ceiling,floors etc. with testing of water flow after refixing of GI pipe line complete all as specified and directed by Engineer-in-charge. Note :- Necessary excavation and earth work shall be measured and paid separately
(a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 32mm bore
(e) 40mm bore
(f) 50mm bore
(g) 80mm bore
(h) 100mm bore
Supply and laying in trench/fixed on wall/floors galvanized steel water tubing medium grade ISI marked of the following sizes incl all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc. complete all as directed . Make Jindal/Tata/Prakash Surya. Note :- Necessary excavation and earth work shall be measured and paid separately
(a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 32mm bore
(e) 40mm bore
(f) 50mm bore
(g) 80mm bore
(h) 100mm bore
Laying only in trench/fixed on wall/floors galvanized steel water tubing medium grade ISI marked of the following sizes incl all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc complete all as directed . Make Jindal/Tata/Prakash Surya/. Note :- Material are issued by department for under free for laying and necessary excavation and earth work shall be measured and paid separately
(a) 20mm bore
(b) 25mm bore
(c) 40mm bore
(d) 50mm bore
(e) 80mm bore
(f) 100mm bore
S&F gunmetal globe or gate valve with iron wheel head screwed bolt ends for iron pipe of the following sizes complete incl taking down old gate valves all as specified and directed by Engineer-in-charge. Make : Leader/Zoloto
(a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 32mm bore
(e) 40mm bore
(f) 50mm bore
Taking out U/S CI sluice valve for the following sizes, supply and fixing new CI sluice valves Class PN1 confirming to ISI with flaged ends both ends with gun metal/steel spindle, round wheel incl jointing materials complete all as directed. Make Durga/Kirloskar/Kartar/Upadhyay ISI :-
(a) 80mm bore
(b) 100mm bore
S&F in replacement of CI foot valve of 80mm dia including taking down the old unserviceable foot valve all as specified and directed by Engineer-in-Charge.
Removing the existing sluice valve of the following sizes and takinng out the worn out gate and spindle refixing back the gate supply and fixing the new spindle made out of stainless steel rod of suitable size to fix the existing gate inc check nut regrinding of the gate fixing of nuts bolts gaskets etc complete all as specified:
(a) 80mm bore
(b) 100mm bore
M&L for Cutting the existing CI/GI pipe 80/100 mm bore or screwing existing CI/GI pipe for addn or altn inc providing 25/20mm dia ferrule scrwewed both ends complete all as directed. Note: Necessary earth work shall be measured and paid separately.
Opening the pump and motor for inspection and repairs and replacing the worn out parts with new parts as orderd under respective items and cleaning oiling, greasing and making the pump motor fully functional and reassemble the pump and motor as per original assembly inc cleaning the exposed surface of pump and applying one coat of synthetic enamel paint inc replacenment of worn out minor items such as packing bolts nuts and Gaskit etc with new parts inc testing complete all as specified and directed by the Engr-in-Charge for the following pump sets:
(a) Centrifugal/Monoblock pumpset 0.5 HP to 3 HP Signle phase, 415 Volts
(b) Centrifugal pumpset 5 HP 3 phase, 415 volts
Note: Cost of Rewinding and spare parts of the pupmset shall be measured and paid separately.
M&L for dismantling of centrifugal/monoblock pump set and transportation of nearset wokshop and return back after completer repair and refixing the pump set at same place and connected all cable connection and mounting properly with complete testing all as specified and directed by Engineer-in-Charge.
M&L for Rewinding the following Centrifugal/Monoblock pumpsets with winding wire of appropriate gauge and weight and suitable make as per original winding after removing the existing inc providing same class insulation all as directed:
(a) Monoblock pumpset 1 HP to 3 HP single phsse, 415 Volts
(b) Centrifugal pumpset 5 HP 3 phase, 415 volts
S&F the following spare parts for Centrifugal pumpsets of capacity 5 Hp 3 phase 415 volts of any make complete all as directed.
(a) Impeller for pump
(b) Bearing for pump set
(c ) Pump shaft
(e) Rubber bushing for coupling
M&L construction of brick masonary valve pit built with cement mortar 1:6 including all excavation and earth work in any type of soil and disposal of surpluse soil to a distance not exc. 50 mtr all as directed by Engineer-in-charge including 10mm thick plastering internally in CM 1:4 and flush pointing in same mortar to brick work externally as work proceeds and cement concrete in foundation PCC (1:4:8) type D-2 15 cm thick & PCC 1:3:6 type C-1 coping, including 75 mm thick & hard core of gauge and exc. 63mm using broken stone /bolder, MS sheet cover 3.15 mm thick MS angle iron frame, handle locking arrangement and painting to steel surfaces including dismantling of old valve pit complete all as specified and directed by Engineer-in-Charge. incl necessary excavation earth work of the following sizes :-
(a) 900 mm x 900mm x 900mm.
(b ) 1200mmx1200mmx1200mm
M&L for Cutting and removing of the following damaged U/S collars from the existing position, supply and connecting new collars of the existing model and size with necessary lead joints all as directed:
(a) 100mm bore
Note: Lead joints and earth work shall be measured and paid under relevant items.
M&L for Cast iron bends of Bore upto 200 mm bore (any type,radius and angles) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, single branch, 'Y' junction double branch, cross(all socket, spigot) collars, caps plughs complete all as specified and directed.
Suply and fix non return valve metal cased body of the following capacity inc removing of the U/S and testing complete all as directed with by pass arrangements:-
(a) 80mm bore
(b) 100mm bore
Suply and fix Air release valve metal cased body of the following capacity inc removing of the U/S and testing complete all as directed with by pass arrangements:-
(a) 80mm bore
S&F DOL starter for suitable for 5 HP 3 phase centrifugal pump set complete all as directed
S&F Single phase preventer 230 volt 50 Hz for monoblock/centrifugal pump complete all as specified and directed by Engineer-in-Charge. Make: L&T/Legrand/Seimens/Schinder
Repairs to Mechanical water level indicator including replacing steel wire rope, floot valve and welding of broken stand, scrapping of existing paint and painting with enamel paint over a coat of redoxide and marking of level for sump of any capacity
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 25 x 4mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 40mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed.
M/S SHAKTI ELECTRIC WORKS
Havish Construction
M/S Ajay Kumar Mahajan
J M Builders And Engineers
Pathania Builders
Roshan Lal Thakur
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .