Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC C O OM PRAKASH AGARWALLA BANTOW PO KHELMATI PS NORTH LAKHIMPUR LAKHIMPUR PIN 787031 | LAKHIMPUR | ASSAM | 787031 | ₹1.0 Cr | L1 | Accepted-AOC L1 |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Conflict of Interest as the bidder is a current sitting member of Sonari Municipal Board |
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
4 Apr 2025, 12:00 pmClosed
The Chairman/ Executive Officer, Sonari M.B
Sonari Municipal Board
Request for Proposal to Select an Agency for Establishing and Commissioning of Material Recovery Facility and Waste to Compost Plant at SONARI MUNICIPAL BOARD Assam
2025_UDD_43239_1
SMB35(B)/SBM/2024-25/645
Open Tender
Civil Works
Item Rate
Sonari
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
₹2.1 L
Sonari Municipal Board
23 May 2025
13 Mar 2025
4 Apr 2025
13 Mar 2025
4 Apr 2025
13 Mar 2025
13 Mar 2025 - 29 Mar 2025
31 Mar 2025
Amount
Estimate of Compost Pit:
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Soling (or sub base) of well burnt soling bricks including filling of interstices and rolling.(Old size bricks, one layer laid on flat.)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
White washing with lime to give an even shade: New Work (Three or more coats)
Applying Priming Coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I. plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified
Providing and fixing bolts including nuts and washers complete
Estimate of Waste Receiving Platform:
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: all kind of soil
Sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering, ramming etc, complete as directed and specified including payment of land compensation, forest , royalty, saletax and other duties and taxes as may be necessary: With river sand or silt by truck carriage including loading and unloading
Soling (or sub base) of well burnt soling bricks including filling of interstices and rolling.(Old size bricks, one layer laid on flat.)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Estimate of Electronic Equipment
Supply and installation of 1000kg and 100g Accuracy Heavy Duty Steel Platform Digital Weighing Scale including all equpment , materials , complete with all taxes.
Computer with in-built modem & fax software
Printer
Telephone(Land Line)
Wireless/Mobile Phone
Complaint Log Book
Table
Chairs
Estimate of Internal Electrification of all Buildings
PVC single core sheathed cable Wiring with copper conductor cables In stove enamelled Stee l Conduit . One light point or one fan point controlled by one switch with cables 1.5 sq. mm size: Group A
PVC single core sheathed cable Wiring with copper conductor cables In stove enamelled Stee l Conduit . One light point or one fan point controlled by one switch with cables 1.5 sq. mm size: Group C
Wiring for light point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 2.5 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75x75x50 mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 147x93x47 mm
supply and fixing following modular base & cover plate on existing modular metal boxes etc as required. 4/5 module
Supply and fixing following modular switch and socket on the existing modular plate & switch box including connections but excluding modular plate etc as required: 3 pin 5/6 amp socket outlet
Supply and fixing following modular switch and socket on the existing modular plate & switch box including connections but excluding modular plate etc as required: Telephone socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc as required
supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
Supply and fixing call bell/ buzzer suitable for D.C/ A.C single phase 230 volts complete as required.
Supply and fixing 3 pin, 5 amp. Ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supply and fixing brass batten/ angle holder including including connection etc as required
Installation, testing and comissioning of ceiling fan, ancluding wiring the down rods of standard length(upto 30 cm) with 1.5sq mm FR PVC insulated, copper conductor single core cable, including providing and fixing phenolic laminated sheet cover on fan box etc as required
Installation , testing and commissioning of pre wired,flourescent fitting/compact flourescent fitting of all types, comlete with all accessories and tube etc directly on ceiling/wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required.
Installation , testing and commissioning of prewired, flourescent fitting/compact flouredcent fitting of all types, comlete with all accessories and tube etc. including supplying and fixing ball and socket arrangement 2no down rods of 20mm dia X 1.6mm thick steel conduit upto 30cm lenth painting and wiring the down rods and connection with 1.5 sq mm FR PVC insulated, copper conductor, single core cable and earthing etc as required.
Installation of exhaust fan upto 510 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc as required.
Extra for cutting and threading of G.I pipe heavy guage down rod for ceiling fan etc. as required
Supply and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required. 2 way single door
Supply and fixing 6 amps to 32 amps rating 240 volts 'B' series miniature circuit breaker suitable for lighting and other loads of following poles in the exsisting MCB DB complete with connection testing and commisssioning etc. as required 6/32 amps, single pole B series
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required
Estimate of External Electrification of MSW Disposal Site
Material & Labour Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long)
Eaves gutter and pipes any description, exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc.) Aluminium paint (each coat)
Fixing only street light fitting, for 70/80 watt vapour or sodium vapour lamp, complete with ballast and capacitor comprising of cast aluminium housing, a pair of aluminium reflectors, a highly transparent clear acrylic cover hinged to the canopy at one end and fixed by means of single spring action at the other, suitable for mounting on 40mm or 50mm dia. G.I. mast or bracket arms with pole fixing attachments and fixing of lamp
Supply and fixing of junction box of size280 X 170 X 130 mm with hinges and locking arrangement & MS clamp made of 50 X 6 mm flat complete in all respect.
Supply and laying of following sizes Al. conductor PVC insulated armoured seathed cable of 1100 V grade at a depth of 750 mm B. G. L. Ditto, but sec area 35 sq. mm. (3 core)
Supply and laying of following sizes Al. conductor PVC insulated armoured seathed cable of 1100 V grade at a depth of 750 mm B. G. L. Ditto, but sec. area 16 sq. mm. (2 core 16 sqm)
supply and fixing of G.I. pipe of 80 mm dia along the pole for protection of under ground cable as required
Ditto, but using galvanised iron strip 25×4mm as earthing lead.
Supply and fixing of feeder pillar of M.S cubicla box of size 100 x 75 x 40 cm made from 2 mm M.S sheet using angle of size 40 x 40 x 6 mm duly hinged and locking arrangement, painting two coats of enameled paint over red oxide primer providing aluminium Bus-bar or suitable size with 100 A/415 V TPN rewirable type main swithc with cement concrete foundation providing 1 Mtr GI pipe on 100 mm dia complete in all respects as per direction of E/I.
Supply and making of earth main hole of size 1' x 1' and 2' deep with 1' x 1' CI chamber brick work etc
LT panel / Feeder Pillar having one no incoming panel, 5 nos, outgoing panel and one number change over switch for DG set.
Estimate of Separation Chamber
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
GI sheet 0.8 mm thick confirming to IS 277:1992 at bottom
Mild steel plates 2mm thick for front open lid
Welding by gas or electric plant including transportation of plant at site etc. complete.
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete: 50x37x1.50 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 100x10 mm
Estimate of Office Room
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm/ (Soft/ loose soil)
Material & Labour Sand filling under floors or in foundations including watering and consolidation
Soling (or sub base) of well burnt soling bricks including filling of interstices and rolling. (Old size bricks, one layer laid on flat)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: In proportion 1:4
Damp proof course to horizontal or vertical surfaces including necessary formwork. In cement concrete 1:2:4, type B-0
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete (nominal mix) in : Chhajja Type B1 (1:2:4 20 mm graded aggregate)
Providing precast cement concrete solid building blocks or slab 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete in walls. Type B1-1:2:4 (20mm graded aggregate) set in cement mortar 1:4.
Reinforced cement concrete (nominal mix) in : Slabs supported on wall, beams and column in floors, roofs, landings balconies, canopies, deck slabs and in shelved and the like. Type B1 (1:1.5:3) 20 mm graded aggregate)
Steel reinforcement for R.C.C. work including straightening, cutting bending, placing in position and binding all complete above plinth level
12 mm thick cement Plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finshed even and smooth including curing complete as directed.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick
White washing with lime to give an even shade : New work (three or more coats)
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cemnt: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter
Butt hinges, heavy weight, cold rolled mild steel, and fixed (size of hinges in 100mm)
Supply and fixing Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides if both faces is covered with decorative face veneer with lipping/ frame to match 30mm.
Supplied and fixed steel door, windows or ventilators, fixed type, with glazing bars.
Providing and fixing M.S. fan clamp type I or II of 16 mmdia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete
Plain, solid, straight chow Kats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed (1st class hardwood)
Material and labour French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
Surfaces of any description, not otherwise described, over 10cm width or girth Synthetic enamel (ordinary tint) (each coat) For Door & Window Frame
Cost of Conveyor Belt
Supply and installation of Conveyor Belt of required capacity including all acesseries complete as per direction of Engineer-in-Charge
Cost of Shredder Machine
Supply and installation of Shredder of required capacity including all accessories complete as per direction of Engineer-in-Charge
Estimate of Shed for MRF
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m²
Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (60.3mm OD hollow pipe)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes (SHS-40 X 40 X 2.6 mm)
Cost of Bailing Machine
Supply and installation of Balling machine of required capacity including all acesseries complete as per direction of Engineer-in-Charge
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .