Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC 197 4 KANTADANGA ROAD FINGAPARA N24PGS PIN 743129 | FINGAPARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.1 L+₹4.2 L (13.0%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹36.1 L+₹4.2 L (13.0%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹38.2 L+₹6.2 L (19.5%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹39.1 L+₹7.2 L (22.4%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR AJIT CHOUDHARY
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REP/MAINT OF BOREWELL, PUMP SETS, PUMP HOUSES, PANEL BOARDS, FILTER PLANT AND CONNECTED WORKS AND REP/MAINT OF STREET SECURITY LIGHTS, SOLAR LIGHTS, FLOOD LIGHTS, FLOOD LIGHT, HIGH MAST AND OTHER ALLIED WORKS AT AFS SALUA UNDER GE (AF) KALAIKUNDA
2023_MES_584261_1
C/8845/E8
Open Tender
Street Lighting
Item Rate
270 days
SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹60,000
Yes
2 May 2023
3 Mar 2023
23 Mar 2023
3 Mar 2023
22 Mar 2023
17 Mar 2023
Amount
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of NINE months for 20/25 HP capacity submersible pump sets installed at various locations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies by overhauling/servicing cleaning thoroughly discharge/suction cases, impellers ,shaft and assembling pump carefully after replacement of suction strainer, 'O' ring, wearing ring, Bearing bush upper & lower, valve seat, valve ring, required quantity of impeller, machining works (if any) including applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of pump external surface complete with and including(a) Lifting of defective submersible pumping set of any make and capacity from bore well after providing lifting tools , chain pulley etc. as required carefully, by disconnecting/dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuse all complete and (b) Lowering of repaired /overhauled/reminded submersible pumping set of any make and capacity inside bore wells after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines with new rubber gasket 3 mm thick, nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge complete all as specified and directed. [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves] NOTE : (i) The cost of transportation of the defective submersible pumping sets( pump or motor ) from site to OEM workshop & back is deemed to be included in the quoted rates. (ii) Column pipe//supporting chain required deemed to be included in Quoated rates (iii) Rewinding shall be measured separately (iv) refixing of column pipe to be done after proper descaling (iii) Repair of motor and pump measured separately however if any repair which is not catered in BOQ and it is necessary to making the pump functional shall be provided by contractor without any extra cost. (iv) refixing of column pipe to be done after proper descalin (v) Each maintenance job shall be covered period of 09 Months..(vi) All minor spares required for making the pump functional shall be provided by contractor without any extra cost.(vii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE kalaikunda officials or their representatives.The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service to the machinary/equipments during comprehensive maintenence period. (viii) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contract (vi) Cost of minor items like insulating tape,gland packing materials, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoated rate.
All as per item No. 01 here-in-before but capacity 7.5 HP open hole submersible pump/.Non clogging sewage pump complete as specified and directed.
M & L for rewinding of burnt submersible motor 25/20 HP, 3 phase ,415 V, 50 Hz of any make through authorised services centre of OEM with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface and water proof jointing for submersible cable 3 core, with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc. complete as specified and directed.
All as per item No. 03 here-in-before but capacity 7.5 HP open hole submersible pump/ Non clogging sewage pump complete as specified and directed.
Supply only Bowl CI submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix in replacement of sleeves (S/S) submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix of rubber bush submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix stud nut of submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix neck ring of submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix thrust bearing of submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
M & L for disconnection of electrical connections de-couplings from centrifugal pump, unscrewing foundation nuts, bolts & washers of squirrel cage induction motor from foundation base plate and taking out carefully for comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of 09 monthsof 15 HP (3 phase, 415V, 50C/S, AC Supply) of any make overhauling, servicing, cleaning thoroughly cases, impellers ,shaft, bearing housing, gland packing, descaling all derts and assembling after repair with required machining works ( if any), new key, new both end bearings, old bearing cover, new gland packing with old gland cover, old/new impeller, stuffing box stud, rubber coupling including applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of pump external surface, inluding rewinding of burnt centrifugal pump 15 HP of any make through authorised services centre of OEM with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete , and refixing after repair, jointing coupling with pump, electrically connected, setting proper alignment with pump with old/new nuts, bolts & washers, rubber coupling joint and testing complete (iii) Repair of motor and pump measured separately however if any repair which is not catered in BOQ and it is necessary to making the pump functional shall be provided by contractor without any extra cost. (v) Each maintenance job shall be covered period of 09 Months..(vi) All minor spares required for making the pump functional shall be provided by contractor without any extra cost.(vii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE kalaikunda officials or their representatives.The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service to the machinary/equipments during comprehensive maintenence period. (viii) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contract (vi) Cost of minor items like insulating tape,gland packing materials, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoated rate.
All as per item No. 11 here-in-before but capacity upto 7.5 HP pump complete all as specified and directed.
Supply & fix Rotor shaft with couplings and seals of above pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of marking tape as per OEM specification complete all as specified and directed.
S&F in replacement of ' O ' Ring and gasket centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of Radial bearing upper centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of radial bearing lower centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of pump bearing centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of Shaft key centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) reccommendations through OEMs Authorised Service Centre Engineers or through OEMs Certified Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Re - development of existing / old bore well by air compressor or other machine (Minimum air compressor used 8- 10 hrs per bore ) with air line pipe after Lifting of submersible pumping set of any make and capacity from bore well after providing lifting tools, chain pulley etc. as required carefully, by disconnecting /dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuse all complete and (b) Lowering of submersible pumping set of any make and capacity inside bore wells after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines with new rubber gasket 3 mm thick, nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge Note : 1. Any tools & plants required to complete the job shall be include the rate of quoted . 2.refixing of column pipe to be done after proper descaling . 3. All minor spares required for making the pump functional shall be provided by contractor without any extra cost.
S & F in repairs submersible cable flat PVC insulation of type C and having PVC sheath of type ST2, flexible conductor, FR-LSH, 3 core of size 6 sqmm complete all as specified and as directed.
M & L for cleaning and washing of inside portion of RCC OH reservoirs/Water tank of Capacity of Round/ Square type of Capacity 100000 gallons (including 02 chambers) up to 25 mtr height ,located in domestic area, with Anti-bacterial agent consisting of following process: - Dewatering the tank by mechanical means as directed, de-silting and removing of left over dirty water up to 100 to 150 mm in the bottom of the tank and sludge with special sludge pump, cleaning of walls and ceiling with special mechanized high pressure jet machines by rotary jet system at 100-120 Bar pressure (120 Kg /sq cm) which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains and cleaning chemicals if required of make Eureka Forbes Ltd or equivalent as approved by GE, floor of the dirty tank should be thoroughly cleaned up by fry jet cleaner to accumulate all dirt ,the remaining sludge should than be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial Vacuum Cleaners to make the floor totally dirt free, application/spraying of Anti-Bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the above operations should be executed by trained workers and technicians, properly dressed along with gum boots, to work as per the direction of Engineer in charge. and writing "Date of cleaning and Next due date of cleaning" on the column of tank at specified location with and including necessarry scalfolding and safety measure complete all as specified and directed.
All as per item No. 22 here-in-before but capacity of 50000 gallons, complete all as specified and as directed
All as per item No. 22 here-in-before but capacity of 22000 gallons, at Aerator deck to flux mixer complete all as specified and as directed .
All as per item No. 22 here-in-before but at Sedimentation tank (28000 Gallons /h) complete all as specified and as directed .
All as per item No. 22 here-in-before but at Filter bed (28000 Gallons ) complete all as specified and as directed .Note for item No. 22 to 26 : (i) Removing of bee heavs and cleaning of vegitation grown on tank shall be done by the contractor without any extra charge. (ii) All T&P required at site for cleaning of tank shall be arranged by the contractor without any extra cost.. (iii) All safety measures, safety belts, helments and other safety tools required at site for the trademens deployed for cleaning of tanks (under ground and over head RCC tanks) shall be provided by the contractor without any extra cost. (iv) Contractor has to clean the tank after tanking permission from Eng in Charge in one week advance. (v) Contractor shall use dewatering pump and industrial vaccume cleaner for cleaning of tank. (vi) Contractor shall deploy sufficient labour for cleaning the tank with stipulate time period of same day so that water supply from that tank would not be hampered. (vii) Contractor has to submit the photos of inside tank before cleaning and after cleaning to the Eng in Charge before claiming for payment. (viiii) Contractor shall provide ACP sheet of size 400 mm x 400 mm on each tank for writing date of cleaning of tank and next due date of cleaning on blue base with white colour. (IX) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the above mentioned works.
Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 10 Metres in length, in any type of soil, suitable for passing through 20mm to 80 mm bore, galvanised steel tubing,complete all as specified and directed.
S&F in replacement of PVC flexible pipe of size 100mm including clamps and its nuts to be fitted in sewage pumps complete all as specified and as directed.
Supply only Ferric Alum Gde I for purification of water containing lead ( as Pb) 30 ppm maximum confirming to IS 299/ 1989 complete all as specified and as directed.
Supply only calcium hypochlorite granule 65 % to 70 % chlorine grade I in air tight sealed plastic bags for treatment of drinking water complete all as specified and as directed. Note :- 1. Approval of chemical ( calcium hypochlorite) shall be given after verification of test certificates and their chemical analysis , strength in terms of quantity of chlorine content. 2. The brand/make of chlorination chemical must be certified by Govt. Laboratory and confirming compliance of specification , suitable for drinking water.
Supply only Chlorine test kit/ iron test kit against old u/s kit with coloured sample complete with all testing fitments and OT solution in rexine finish box complete all as specified and as directed.
Testing of drinking water sample for servicable borewell No 3,6,7 and after treated water of filter plant of this station with under mention test by authorised lab ie, IIT Kharagpur or District water testing laborotory kharagpur as approved by GE and Test report shall be submitted to GE along with RAR/FB, India :- CHEMICAL TEST :- (a) PH Valve,Temperature,Turbidity,Total hardess (as caco3) mg/l, Alkalinity, TDs ppt. Max,Iron mg/l ,Nitrate mg/l,Chloride mg/l,Residual chlorire mg/l, Fluoride mg/l. BACTERIALOGICAL:- (b) Coliform orgnisms, Faecal coliforms.
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for a period of NINE months of existing of engine oil of Air compressor ( air blower ) fitted with 5 HP 440 V AC 1440 rpm TEFC motor cap: 200 cfm complete all as specified and directed.
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, TPN, with current rating 160 Amps and 35 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In,complete all as specified and directed. [Cat No. DZ1T0160DXD1A of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply & Fix fully automatic star delta Submersible pump starter in sheet steel enclouser suitable for 25 HP pump set , 3 phase , 415 volt , 50 Hz , including making all electrical connection to run the pump and taking out old unserviceable complete all as specified and directed by Engr-In-Charge. Make:- C&S Cat Part No- BE3-SPSDDX254 322 or equivalent in L&T/BCH
Supply & Fix DOL pump starter in sheet steel enclouser suitable for 7.5 HP pump set , 3 phase , 415 volt , 50 Hz including making all electrical connection to run the pump and taking out old unserviceable starter complete all as specified and directed by Engr-In-Charge. Make:- C&S, Cat part No - BE1SPSDDX204 321-HM or equivalent in L&T/BCH
S& F in replacement of brass vertical check valve of size 80 mm for 5 HP/7.5 HP pump complete all as specified and directed
Supply and fixing sluice valve 80 mm bore, ISI marked, as per IS 14846: 2000 , with valid CMLNo. , Batch No. and Manufacturer Serial No., class PN 1.6 with brass spindle, brass check nut, with fiber board gasket, bolts, nuts and washers for fixing the valve in position, in valve pit chambers or location as directed and specified by Engr-in-charge. Make Uphadhya / Kirloskar/ Leader or equivalent make as catered in PS Note : Contractor has to submit the test certificate and Purchase Voucher of valves before claiming the payment..
Material and labour for Joint with rubber or leather gasket for flanged pipes/Sluice Valve/NRV/ARV and any other type of valve and fittings of dia 100mm bore with incl nut, bolts, washers etc. and taking out old unserviceable complete all as specified and Engr-in-Charge.
All as per item No.39 here-in-before but Bore of pipe 80 mm complete all as specified and as directed.
Materials and Labour for valve pit cover using brick masonry with fly ash brick valve chamber of internal size 1.5 M x1.5M x1.0 M with 23 cm thick wall in CM 1:6 including excavation if required, earth work in any strata & PCC 1:4:8 foundation type D-2, 75 mm thick including 20 mm thick PCC 1:2:4 type B1 in & plastering the internal surface with 10 mm thick cement mortar 1:4 if required & replacing old 3.15 mm MS sheet chamber cover double opening arrangement center lock system with 40x40x6mm angle iron frame duly painted with two coat of black bituminous paint over one coat of red oxide primer with and inluding demolition of existing complete all as directed by Engr in Chargre.
Cleaning the vegetation incl grass, bushes, small trees & all vegetation growth complete incl digging out roots of bushes around installation /sump/OH tanks/ valve chamber incl leveling the surface by removing debris to a distance n.exc 50 mtr all as directed.
Materials and Labour for,run lead joint for cast iron spigot and socket pipes and fittings for water mains ,200 mm bore, including burning out lead joints in position and including removing old lead from site, complete all as specified and directed. ( NOTE:- Earthwork shall be included in quoated rates)
All as per item No. 43 above but 150 mm dia.complete all as specified and as directed.
All as per item No. 43 above but 100 mm dia.complete all as specified and as directed.
Materials and Labour for,run lead joint for cast iron spigot and socket pipes and fittings for water mains ,80 mm bore, including burning out lead joints in position and including removing old lead from site, complete all as specified and directed. ( NOTE:- Earthwork shall be included in quoated rates)
Supply and Fix in repairs,ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe 20 mm bore and fixed (Minimum weight 210 grams), complete all as specified and directed. [Make: Prayag Polymer Pvt Ltd Cat No.151 or equivalent Model of Make RS Industries:Polytuf/ Microplast Polymers Pvt Ltd]
Supply and Fix in repairs,ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe 25 mm bore and fixed (Minimum weight 455 grams), complete all as specified and directed. [Make: Prayag Polymer Pvt Ltd Cat No.152 or equivalent Model of Make RS Industries: Polytuf/ Microplast Polymers Pvt Ltd]
Supply and fix in repair water level indicator made of aluminium base, marked with white Radium paint connected with steel wire rope 4 mm dia to counter weight showing level of water containing in tank including 8" dia brass float ball , and greasing of revolving pully of as per site requirement and fixed to pillar of water tank complete all as specified and directed by Engr-in-Charge Note : (i) All T&P required at site for fixing water level indicator on over head Tank at 18/21 mtr height shall be arranged by contractor and necessarry safety measure taken (ii) To remove the Bee Hives for fixing the guadge on water tank of height 18/21 mtr shall be contractor responsbility with any extra cost.
S&F in replacement of 4mm dia steel wire rope for water level indicator of various overhead tanks installed in AF station salua all as specified and directed by Engr-in charge.
Supply and fixing in repair Non return (Reflux valve) 150 mm dia , flap type ISI marked,as per IS 13095: 1991,both end flanged including fiber board gasket, bolts, nuts and washers for fixing the valve in position, or location as directed and specified by Engr-in-charge . Make : Uphadhya / Kirloskar/ Leader
Taking up or down of old galvanised steel water tubing medium grade in walls, floors or ceilings/trenches etc including all fitting cleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed by Engr-in-Charge.
(a) 20 mm bore GI pipe complete
(b) 25 mm bore GI pipe complete
(c) 40 mm GI pipe complete
(d) 50 mm GI pipe complete
(e) 80 mm GI pipe complete
Supply and laying galvanised steel water tubing medium grade as per IS-1239 (Part-1) 2004 including all fittings conforming to IS 1239 (Part-2): 2011 in walls, floors or ceilings/trenches etc in new or old alignment complete with GI pipe clamp all as specified and as directed by Engr-in-Charge. Make: TATA/JINDAL or equivalent make as catered in PS Note: (i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment. (iii) Contractor shall provide MS/GI clamp for fixing the pipe on wall on every 10 cm without any extra cost.
(a) 20 mm bore GI pipe complete
(b) 25 mm bore GI pipe complete
(c) 40 mm GI pipe complete
(d) 50 mm GI pipe complete
(e) 80 mm GI pipe complete
M&L for disconnecting existing tank setting aside for repairs, including cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.300 and not exc. 500 ltrs complete all as specified & as directed. Note : Spare part required to be replaced up to Rs 200 deemed to be included in quoated rates.
M&L for disconnecting existing tank setting aside for repairs, including cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.500 and not exc. 1000 ltrs complete all as specified & as directed.Note : Spare part required to be replaced up to Rs 200 deemed to be included in quoated rates.
Taking down unserviceable street /flood light / Security light fittings any type or any capacity from any location mounted on any type of Poles/Bdgs/ / Tower/ High mast of height up to 18 mtr from bracket after disconnecting of supply cable and refixing the same after carrying out repair and testing on exiting or new location as per site requirement, including repairing of circuit, electrical connection, replacement of defective driver, surge protection device, tracing and rectifying of fault complete all as specified and as directed by Engineer-in-Charge. Note : (i) Supply only LED driver with SPD and electric supply cable will be measured and paid separately under respective item.) (ii) All T&P, ladder etc required at site for the repairing and taking down / refixing of light fitting after repair shall be arranged by the contractor. (iii) If there is any fault in electrical supply line, it shall be contractor liability to identify the fault and get it repair for making the light functional complete all as directed .
S & F LED street lights nominal power 35 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2500, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No.LR02-391-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed.
S & F LED street lights nominal power 60 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 6000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-671-XXX-57-XX of Wipro or Make:- Crompton Cat No. No.Raptor Neo I , Cat No. TRP-409-60-57-SL-GL-NSG OR equivalent of Make mentioned under Particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed.
S & F LED flood lights nominal power 200 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F LED flood lights nominal power 120 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LF20-132-060-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. Note for Item No. 68 to 71(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items. (ii) At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt. (iv)All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer. (v) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly. (vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries. (vii) All LED fitting shall be identified by printing or fixing stickers duly mentioned the C.A number and date of completion. (viii) For any change in product or change in catalogue No. etc due to technological upgradation, letter has to be obtained from the lighting company on their letter head signed by an offical of National level. (ix) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor
Supply only in repair LED driver suitable for 15/20/30/ 35 watt LED street light , 240 Volt , 50Hz , AC . Make of Driver : Bajaj /Crompton/ C&S/ Havells/ Surya/Philips/Century (As per existing) Note :(i) Before procurement contractor shall check the make and model of u/s LED driver as per existing and bring the same or suitable to make the light functional.
Supply only in repair LED driver suitable for 45/60/70 watt LED street light , 240 Volt , 50Hz , AC . Make of Driver : Bajaj /Crompton/ C&S/ Havells/ Surya/Philips/Century (As per existing) Note :(i) Before procurement contractor shall check the make and model of u/s LED driver as per existing and bring the same or suitable to make the light functional.
M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.5 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts including taking down existing GI bracket complete all as directed by Engineer-in-charge including taking down old unserviceable.
M&L for polycarbonate 3 phase busbar system pole junction Box dust, weather rain guarded cable entry and exit arrrangement with closing arrangement of size 300 x 200 x 150 mm with housing of 04 Nos 100 Amps aluminium bus bar fixed on porcelain insulator and connected of cables with lugs, nut bolts and washer including 06 Amps MCB all as specified and as directed.
M&L for polycarbonate 1 phase busbar system pole junction Box dust, weather rain guarded cable entry and exit arrrangement with closing arrangement of size 200 x 150 x 150 mm with housing of 02 Nos 100 Amps aluminium bus bar fixed on porcelain insulator and connected of cables with lugs, nut bolts and washer including 06 Amps MCB all as specified and as directed.
M&L for FRLS wiring in existing locatation for circuit alongwith earth wire 2 x 2.5 sqmm + 1 x 2.5 Sqmm copper cable PVC insulated multistranded from junction box to fitting connecting box etc. (Two run of 2.5 Sqmm wire+01 Run of 2.5 Sqmm wire considered as one unit) all as specified and as directed.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with stranded aluminium conductor of cross sectional area 70 sqmm 3.5core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking out complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A').
All as per item No 67 here-in-before but of size 25 Sqmm 4 core complete as specified and as directed.
All as per item No 67 here-in-before but of size 10 Sqmm 2 core complete as specified and as directed.
All as per item No 67 here-in-before but of size 16 Sqmm 4 core complete as specified and as directed.
Material and labour for 40 mm dia Unplasticiscd PVC pipes of pressure rating 10 kgf/cm2 laid in trenches for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc,including clamps, nut, bolt and washers complete all as specified and directed
All as per item Serial No 71 here-in-before but for 50 mm dia pipe including clamps, nut, bolt and washers.
Material and Labour for applying two coats of aluminium paint on old painted surfaces of steel tubular poles, type 410 SP-22/ SP-31 (8.5/9.00 Metres Long), including cross arms,brackets etc., up to 1.5 M above PCC base and marking alternate strip horizontally of width 15 cm with two coats of synthetic enamel paint (ordinary tint) above PCC base up to 1.5 M height and numbering of poles with letters and figures of height 75 mm at a height of 2.60 metre from ground level including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of aluminium paint on old painted surfaces of steel tubular poles, type 410 SP-41 (11 Metres Long), including cross arms,brackets etc., up to 1.5 M above PCC base and marking alternate strip horizontally of width 15 cm with two coats of synthetic enamel paint (ordinary tint) above PCC base up to 1.5 M height and numbering of poles with letters and figures of height 75 mm at a height of 2.60 metre from ground level including preparation of surfaces complete all as specified and directed.
Supply and fixing Ambient light timer switch i.e nature switch which can works bases on measurement of lux level of Infra red rays along with enclosure box having dust & termite proof outdoor type mountable on electric panel or on pole Single Phase with contactor rating 16 Amps, MCB rating 25 Amps and load bearing 3 KW all as specified and directed by Engineer in charge . Note :- The Timer switch having the following features:- (a) Automatic switching on at Dusk (ambient light less than 60 Lux). (b ) Automatic switching off at Dawn ( ambient light greater than 10 lux). (c) Duration based part night operation facility. (d) High voltage protection ( 280 V ) with auto reset. (e) Low voltage protection ( 150 V ) with auto reset. (f) Immunity to dust , bird sitting ,FOG & cloud cover. (g) Degree of protection conform to IP65.
All as per Ser Item No 75.00 but here in before Three Phase with contactor rating 16 Amps, MCB rating 20 Amps and load bearing 5 KW all as specified and directed by Engineer in charge .
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for in ground/ floors complete all as specified and as directed.
M&L for cement concrete in foundation filling and mass concrete (1:3:6) type C2 (using 40 mm graded stone aggregate) complete all as specified.
Materials and Labour for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out all as specified and directed. Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor beyond every hours till services restored .
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.
Supply and laying sub class ‘B’, bricks, in cable trenches, as cable protection complete all as specified and directed.
M&L in dry coarse sand in cable trenches before and after the cables are laid complete all as specified and directed
Ganguly Construction
Neha Enterprise
Kalpana Traders
M/S. CONCO CONSTRUCTION
SHARMA ENTERPRISES
M/S OM BUILDERS
SNEHANGI TRADERS
M/S. GHOSH CONSTRUCTION
SUMAN CONSTRUCTION
M/s Antara
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .