| 1 | L1₹5.0 LAccepted-AOC P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L1 | Accepted-AOC Accepted due to lowest | |
| 2 | L2₹5.2 L+₹3,538 (0.68%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L2 | Rejected-Finance Rejected due to not lowest | |
| 3 | L3₹5.9 L+₹67,216 (13.0%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L3 | Rejected-Finance Rejected due to not lowest | |
| 4 | L4₹5.9 L+₹68,561 (13.2%)Rejected-Finance KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L4 | Rejected-Finance Rejected due to not lowest | |
| 5 | L5₹6.0 L+₹83,090 (16.0%)Rejected-Finance | L5 | Rejected-Finance Rejected due to not lowest |
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
29 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
GE LEKHAPANI, Tinsukia, Assam
REPAIR/MAINT OF SUMMER APPLIENCES GEYSER,WATER COOLERS, REFRIGERATORS AND ALLIED CONNECTED WORKS AT LEKHAPANI MILITARY STATION UNDER GE LEKHAPANI
2020_MES_382615_1
8564/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
CLASS E CAT b (i)
4 documents required · 4 mandatory
₹500
GE Lekhapani
₹9,000
Yes
25 Nov 2020
1 Oct 2020
31 Oct 2020
1 Oct 2020
29 Oct 2020
15 Oct 2020
60 days
Amount
Servicing and maintanance of Split AC 1.5/2.0 ton capacity complete indoor/outdoor unit for routine check up for smoth functioning checking of refrigerant gas, gas leakage, cheking the functioning of compressor, blower motor, all electrical/electronic circuit, functioning of remote, functioning cooling system, cleaning and washing by using liquid of air filters, cooling coil, condensor coil, blower motor, fan motor complete indoor/outdoor unit all as directed by Engr-in-charge. NOTE Spares required will be measured and paid separately
Taking out existing burnt / unserviceable compressor unit from 1.5 ton capacity of window/split type air conditioner and replacing the same with factory built hermetically sealed rotary compressor unit including necessary accessories and mounting materials, welding, leak testing by charging with CO2/dry nitrogen gas. Evacuating the system and charging of R-22 Refrigerant gas after ensure leak proof condition and testing complete all as directed by Engineer-in-Charge etc. of make - Godrej/Techmesh/Blue star/Hitachi. Note - Refrigerant gas shall be measured and paid separately.
All as per item No 2 here-in- before but of capacity 2.0 ton
Taking Down of existing damaged / burnt blower motor from split/window AC and supply & fixing of new blower motor with capacitor & mounting materials single phase, 230 Volts 50 Hz suitable for 1.5 ton & 2 ton capacity of window/Split type AC
Taking Down of existing damaged / oudoor fan motor from split/window AC and replace the burnt unserviceable parts,rewinding , refixing the same after repair and testing its proper function all as directed by Engr -In - Charge
Taking out the defective thermo static switch, supply and fix new thermostatic switch for 1.5/2 ton window/split type AC
Taking out the defective over load protector relay, supply and fix new over load protector for1.5 ton window/split type AC
Taking out the defective starting relay, supply and fix new starting relay for 1.5 ton window type AC
Taking out the existing defective starting capacitor, supply and fix new starting capacitor suitable for 1.5 ton & 2 ton window/split type AC.
Taking out the unserviceable running capacitor, supply and fix new running capacitor suitable for 1.5/2.0 ton window/split type AC
M&L for charging of refrigerant R-22 including cost of leak detection, welding, and refitting the same in entire system as required, including replacing defective liquid strainer, capillary tube and testing complete all as directed by Engineer-in-Charge
M&L for taking out unserviceable PCB unit from split/window AC 1.5/2.0 capacity and replace the burnt unserviceable electronic parts, refixing the same after repair and testing its proper function all as directed by Engr -In - Charge
S & F of blower fan blade set for window/split AC as per exixting make including taking down old one complete all as directed
Taking out unserviceable existing cooling coil from window/split AC of 1.5/2.0 ton capacity and supply and fixing of new cooling coil with thermostat complete all as directed
Taking out existing burnt / unserviceable compressor unit from Refrigerator & replacing the same with factory built hermetically sealed compressor unit including necessary accessories and mounting material, welding, leak testing by charging dry Nitrogen gas, charging of refrigerant R-134 A after ensuring leak proof condition. Testing complete all as directed by Engineer-in-Charge. Note Refrigerant gas shall be measured and paid separately. Refrigerator of 165 ltrs to 240 ltrs capacity
All as per item No 16 above but of capacity 260 to 315 ltrs refrigerator
Taking out defective thermostatic switch, supply and fix new thermostatic switch for refrigerator of capacity 165 ltrs to 315 ltrs
Taking out defective Refrigerator freezer chamber , supply and fix new Refrigerator freezer chamber of capacity 165 ltrs to 315 ltrs
Taking out faulty starting relay cum over load protector, supply and fix new starting relay cum over load protector for refrigerator upto 315 ltrs capacity as per existing refrigerator
Taking out existing burnt / unserviceable compressor unit from water cooler & replacing the same with factory built hermetically sealed rotary compressor unit including necessary accessories and maintaining material, welding, leak testing by dry Nitrogen gas and charging R-134A refrigerant gas after ensuring leak proof condition and testing of water cooler 40 / 80 ltrs capacity all as directed by Engineer-in-Charge
Taking out existing burnt / unserviceable compressor unit from Deep Freezer & replacing the same with factory built hermetically sealed compressor unit including necessary accessories and mounting material, welding, leak testing by charging dry Nitrogen gas, charging of refrigerant R-134 A after ensuring leak proof condition. Testing complete all as directed by Engineer-in-Charge. Note Refrigerant gas shall be measured and paid separately. Deep Freezer of 300 ltrs to 400 ltrs capacity
Taking out defective / unserviceable starting relay , supply and fixing of starting relay suitable for water cooler of capacity 40 / 80 ltrs
Taking out defective / unserviceable starting capacitor , supply and fixing of starting capacitor suitable for water cooler of capacity 40 / 80 ltrs
Taking out defective / unserviceable running capacitor , supply and fixing of running capacitor suitable for water cooler of capacity 40 / 80 ltrs
Taking out defective / unserviceable over load protector , supply and fixing of over load protector suitable for water cooler of capacity 40 / 80 ltrs
Taking out defective / unserviceable thermostatic switch , supply and fixing of thermostatic switch suitable for water cooler of capacity 40 / 80 ltrs
Taking out unserviceable PVC ball valve with polythene float & fly nut of 15 mm dia , supply and fixing of PVC ball valve of high pressure with polythene float & fly nut of 15 mm dia suitable for water cooler of capacity 40 / 80 ltrs
Supply and charging of refrigerant R-134A including cost of welding, leak detection and rectification in the entire system with replacement of liquid strainer and capillary tube including testing of water cooler of capacity 40 / 80 ltrs , including toping up in centralised AC plant all as directed by Engineer-in-charge.
Taking out of existing damaged / burnt blower motor, supply and fixing of new blower motor, single phase, 230 Volts, 50 Hz suitable for water cooler of capacity 40/80 ltrs including fixing arrangement all as directed by Engineer-in-charge.
Taking down, opening and dismantling storage type water heaters (geysers) of capacity 25/50 ltrs vertical/horizontal type cleaning, descaling, re-assembling and re-installation in the existing place and container by hand operated hydraulic pump complete after necessary repair/replacement of unserviceable items all as directed . (Note : Spare as required shall be measured and paid under relevant items)
S & F heating element of rating 2000 W circular/triangular shape push/thread type with rubber washers of make Bajaj/Theeta/Johnson/Racold
S & F thermostat for geyser of capacities 25/50 Ltrs of make Bajaj/Elcon/Johnson/Racold
Supply and fix safety valve/high pressure air release valve ISI marked.
Supply and fix hot/cold water PVC armoured heavy duty connection pipe suitable for hot water of size 15 mm dia with PTMT nuts of length 450 mm including taking down old/damage PVC connection pipe all as directed
Supply and fix angular stop cock fancy type chromium plated of size 15 mm dia
M/s HALDER ENTERPRISE
M/S S. P. ENTERPRISE
M/S CHANDAN ENTERPRISE
FREEZCON
M/s PRABIR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .