Loading…
Loading…
Tender Value
₹7.2 L
EMD Value
₹17,888
Closing Date
5 May 2025, 9:30 pmClosed
Rural Drinking Water and Sanitation Department
A/P/S to 7.5 HP Water supply installation PDO Bhairamadagfi site in Afzalapur Taluka
RWSSD/2025-26/WS/WORK_INDENT9230
RWSSD/2025-26/WS/WORK_INDENT9230
Open
Water supply/sewage lines
Electronic Documents, First(One Cover)
RWSSD Division Office Kalaburgi
₹500
₹17,888
27 Apr 2025
27 Apr 2025
5 May 2025
A/P/S to 7.5 HP Water supply installation PDO Bhairamadagfi site in Afzalapur Taluka
20006-PSC pole 9.0M long 200 KG WL
200105 RCC pole 9.0M long 145 kg WL
27901205-11 kv Horizontal cross arm with
27901205-11 KV horizontal cross arm wity
2791002 DP Struture with 9 mtrs RCC P
2811101-Guy with complete set
283005-11 KV pin insulator (Shell oni)
283040-DISC insulator (GI pin)
284108 Rabiitr ACSR conductor
Erection of RCC/PSC poles 9 to 10 mtr Long but in a pit of 1.8mtr depth
Erection of RCC/PSC poles 9 to 10 mtr Long but in a pit of 1.8mtr depth G Harsoil
Erection of RCC/PSC poles 9 to 10 mtr Long but in a pit of 1.8 MTr depth
Erection of RCC/PSC poles 9 to 10 mtr Long but in a pit of 1.8 MTr depth Hard soil
Fixing of V shape /Horizontal cross arm including single top support braces and insulatos fixing
Fixing of V shape /Horizontal cross arm including single top support braces and insulatos fixing Hard soil
Same as above using RC ploes 9 mtr to 10 mtrs long
Fixing fo Guy sets with break insulators making use of 7/3 15mm (7/10 SDWG) galavanised steel wire with trun bucle and anchoring arrangment as per approved drawing
Fixing fo Guy sets with break insulators making use of 7/3 15mm (7/10 SDWG) galavanised steel wire with trun bucle and anchoring arrangment as per approved drawing Hard Soil
For Rabbit ACSR
2788111-11 KV Danger board
278911 Barbde wire (10mtrs)
27911102-9 Mtr RCC DP transformer Strct
281008-8 SWG GI wire
281110-7/10 SWG Guy wire
2811101 Guy with Complete set
2811103 Earthing Materials type foor gr
289029-PVC wire 50 sqmm
301107- LT Protection kit
302011-11 kV DOLO cutouts Convetent
303200 LA 9 KV Ska metal Oxide
304212-11 KV GOS 200A single break
321437-25 KVA Aluminum wdg BEE 4 sta
357510- LT Electronic Tri Vector Met
357531 Whole Currente meter 5-30A 3P
358056 WITH CT Ration 50/5 for 15/25 K
Fixing Danger Board
GI Barbed Wire (12 Mtrs/1kg)
Erection of pole up to 63 kVA wewith 9 mtrs RCC pole
Erection of pole up to 63 kVA wewith 9 mtrs RCC pole Hard soil
Fixing of Guy set with break insulator makign used of 7/3.15mm (7/10 SWG) galvanised steel wire with furn buckle and anchoring arrangment as per approved drawing
Fixing of Guy set with break insulator makign used of 7/3.15mm (7/10 SWG) galvanised steel wire with furn buckle and anchoring arrangment as per approved drawing Hard soil
Fixing of Guy set with break insulator makign used of 7/3.15mm (7/10 SWG) galvanised steel wire with furn buckle and anchoring arrangment as per approved drawing Hard soil
Providing GI pipe Earthing for lighting arresters Transormer neutral and Transormer metal parts (Excluding diggin of pits)
Wiring of Lighring power circuit using one PVC insulated 1100 kv grade stranded Aluinum unsheathed wire 4 sq mm single core muti core cable in open of cocealed system of wiring
Fixing of LT protection kit
HG fuse 11 kv solid core type (3 Nos)
Fixing of 3 Nos lighting arrestors including wiring
Fixing of GOS including wirting (11 KV SB 200A)
Erection of 25-63 Kva transormer on transformer structure
LT Electronin Trivector meter 5A Class 0.5/1.00 Accuracy
LT Electronin Trivector meter 5A Class 0.5/1.00 Accuracy
LT Metering Box for housing ETV meter with CT
Statutroy charges as per actuals (Inspectorate charges civic bod Charges etc)
Area Specific Kalyan Karnatakla
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .