Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | ₹7.2 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹7.2 L+₹2,795.36 (0.39%)Rejected-AOC | ₹7.2 L+₹2,795.36 (0.39%) | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | PALANIKUMAR K H1 | S GOVINDARAJSU H2 |
|---|---|---|---|---|---|
| 1.01 | Dismantling RCC by manual / by using deploying
machineries | 20 | sqm | 4,310 ₹86,200 | 4,308 ₹86,160 Lowest |
| 1.02 | Dismantling Pressed Tiles & Weathering Course | 130 | sqm | 50 ₹6,500 | 45 ₹5,850 Lowest |
| 1.03 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum | 10.4 | cum | 4,200 ₹43,680 | 4,160 ₹43,264 Lowest |
| 1.04 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete | 130 | sqm | 1,310 ₹1,70,300 | 1,308 ₹1,70,040 Lowest |
| 1.05 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT | 11.04 | cum | 7,550 ₹83,352 | 7,525 ₹83,076 Lowest |
| 1.06 | Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications | 158.7 | sqm | 290 ₹46,023 | 286 ₹45,388.2 Lowest |
| 1.07 | Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications | 240 | sqm | 330 ₹79,200 | 329 ₹78,960 Lowest |
| 1.08 | Supply and fixing of 20 W 4feet LED fittings with LED | 5 | No | 805 ₹4,025 Lowest | 805 ₹4,025 Lowest |
| 1.09 | Supplyandfixingof1200mm(48")sweepACceilingfancompletewithsteppedelectronic300Wregulatorwith1metre down rod with fan clamp with side plates and cross arm of size 450mm (18") | 2 | No | 3,021 ₹6,042 Lowest | 3,021 ₹6,042 Lowest |
| 1.10 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End | 5 | No | 2,820 ₹14,100 | 2,800 ₹14,000 Lowest |
Tender Value
₹8.9 L
EMD Value
₹8,900
Closing Date
28 Jan 2026, 3:00 pmClosed
Sivakasi Corporation Commissioner
Sivakasi Corporation Office Rathinam Nagar Sivakasi
Repair and Maintanence work at arasan complex in Sivakasi City Municipal Corporatio
2026_MAWS_645881_22
3001/2025/E1
Open Tender
Civil Works
Works
30 days
sivakasi
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹8,900
Yes
22 Jul 2026
22 Jan 2026
28 Jan 2026
22 Jan 2026
28 Jan 2026
22 Jan 2026
Dismantling RCC by manual / by using deploying machineries
Dismantling Pressed Tiles & Weathering Course
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Supply and fixing of 20 W 4feet LED fittings with LED
Supplyandfixingof1200mm(48")sweepACceilingfancompletewithsteppedelectronic300Wregulatorwith1metre down rod with fan clamp with side plates and cross arm of size 450mm (18")
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End
supply and fixing of 48W LED Street Light Fitting with LED
Painting two coats for Interior surface with approved Interior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
Dismantling RCC by manual / by using deploying machineries labour charges etc., complete as per standard specification -
Providing centering shuttering including necessary supports for all PCC works including all charges etc., complete as per standard specifications. For Slab
Suppling and fabrication placing in position of M.S.(or)RTS rod for required size and length as directed by the departmental officers approved design including bending cutting tying and cost of binding wire cost and conveyance of all materials to site etc. complete as per standard specification
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_774373.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.78 MB
BOQ_774373.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .