Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-Finance 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | ₹24.3 L | L1 | Accepted-Finance that the bid is L1 |
| 2 | L2₹25.9 LRejected-Finance | ₹25.9 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹28.2 LRejected-Finance 19 B PANKAJINI CHATTERJEE ROAD KOLKATA 700033 | KOLKATA | KOLKATA | WEST BENGAL | 700033 | ₹28.2 L | L3 | Rejected-Finance that the bid is not L1 |
| 4 | L4₹29.2 LRejected-Finance | ₹29.2 L | L4 | Rejected-Finance that the bid is not L1 |
| 5 | Rejected-Technical 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | - | - | Rejected-Technical Due to absence of proper shortfall documents (i.e. Credential as per NIQ) |
| Sl No | Description | Qty | Unit | TESLA ENGINEERING SOLUTION L2 | BALAJI FIRE PROTECTION SYSTEMS L3 | Fire Shield Engineering & Equipments L4 | Creative Projects L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors.
(Approved Make : Cerberus Pro / Honeywell-Notifier/ Bosch) | 400 | Nos | 2,400 ₹9.6 L | 3,100 ₹12.4 L | 3,200 ₹12.8 L | 2,590 ₹10.4 L |
| 2.00 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator.
(Approved Make : Cerberus Pro / Honeywell-Notifier/ Bosch) | 16 | Nos | 2,300 ₹36,800 | 2,900 ₹46,400 | 3,000 ₹48,000 | 2,300 ₹36,800 |
| 3.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required.
(Approved Make : Cerberus Pro / Honeywell-Notifier/ Bosch) | 20 | Nos | 3,200 ₹64,000 | 3,300 ₹66,000 | 3,200 ₹64,000 | 3,420 ₹68,400 |
| 4.00 | Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make : Cerberus Pro / Honeywell -Notifier/ Bosch) | 20 | Nos | 3,500 ₹70,000 | 3,500 ₹70,000 | 3,300 ₹66,000 | 9,550 ₹1.9 L |
| 5.00 | Supply, Installation, Testing & Commissioning of Addressable Monitor Modules ( VDS / UL /ERTL/ LPCB / FM approved ) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required.
(Approved Make : Cerberus Pro / Honeywell- Notifier/ Bosch) | 14 | Nos | 500 ₹7,000 | 100 ₹1,400 | 250 ₹3,500 | 550 ₹7,700 |
| 6.00 | Supply, Installation, Testing & Commissioning of Addressable Relay Modules (VDS / UL & FM approved) for switching / integration of Lift / AHU etc complete as required. | 35 | Nos | 3,500 ₹1.2 L | 500 ₹17,500 | 700 ₹24,500 | 2,200 ₹77,000 |
| 7.00 | Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : Cerberus Pro / Honeywell- Notifier/ Bosch) | 130 | Nos | 90 ₹11,700 | 80 ₹10,400 | 50 ₹6,500 | 60 ₹7,800 |
| 8.00Supply, Installation,Testing & Commisioning of Microprocessor based addressable fully networkable fire alarm control panel ( VDS / UL /ERTL/ LPCB / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capcity twice. | |||||||
| 8.10The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. | |||||||
| 8.20 | The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software.
(Approved Make : Cerberus Pro / Honeywell -Notifier/ Bosch) | 1 | No. | 2,32,000 ₹2.3 L | 2,00,000 ₹2 L | 2,10,000 ₹2.1 L | 4,25,000 ₹4.3 L |
Tender Value
₹26.3 L
EMD Value
₹52,500
Closing Date
11 Feb 2026, 1:00 pmClosed
EE-II KNHED PWDte.
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
SITC of Fire Detection and Alarm system and fire damper for Air conditioning system at M. C. Hub building, MCH, Kolkata.
2025_WBPWD_965916_1
WBPWD/EE-II/KNHED/NIQ-63/ 2025-26
Open Tender
FIRE FIGHTING ORG
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹52,500
OFFICE OF THE EE KNHED PWDte.
21 May 2026
2 Dec 2025
13 Feb 2026
2 Dec 2025
11 Feb 2026
9 Dec 2025
8 Dec 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_2339982.xls
BOQ • 0.36 MB
2911_Form.pdf
Tender Documents • 0.50 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid