| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹18.7 L+₹84,808.30 (4.75%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹22.0 L+₹4.1 L (23.1%)Rejected-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 | AJMER | RAJASTHAN | 305001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹22.2 L+₹4.4 L (24.4%)Rejected-Finance 40 VISHNU VIHAR KHERAI SHAMSHABAD ROAD KHERAI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹22.9 L+₹5.1 L (28.5%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR/MAINT OF LT DISTRIBUTION SYSTEM AND OTHER ALLIED WORKS AT AF STATION JAISALMER
2020_MES_356271_1
8672/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹50,000
Yes
23 Jul 2020
26 Jun 2020
18 Jul 2020
26 Jun 2020
16 Jul 2020
10 Jul 2020
60 days
Amount
M&L for repair of complete LT panel by welding of hinges, door, including door, hings with locking arrangement and layout the LT cable in proper manner by excavation & refilling connecting and taking down existing unserviceable cable including painting of complete panel all as specified and directed by Engineer-in-Charge.
M&L for repair of existing indoor / outdoor LT Panel including replacement of complete wiring with suitable size new PVC insulated FRLS multi stranded copper conductor cables (minimum 6 sqmm), voltmeter, switch, ammeter CTs, indicator lamp including replacement of all lugs/thimbles with new copper lugs/thimbles, complete all as as specified and directed. Note : All incoming & outgoing cables of various sizes shall also be re-connected after replacement of lugs/thimbles with new copper lugs/thimbles and quoted rates shall also include this provision. Excavation & earthwork required for taking out cables from loops for replacement of lugs/thimbles shall deemed to be included in quoted rates.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat primer, one under coat and one finishing coat of synthetic enamel paint including disconnecting & taking down old unserviceable complete all as specified and directed.
S&F in replacement pin type insulator porcelain vitreous, white, brown or green for working pressure 1100 volts, 100mm height and 65mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut complete all as specified.
S&F in repair/replacement of aluminium conductor, steel reinforced (ACSR) of any size, any type, as per existing one and stringing properly on the insulators and binding with aluminium wire, connectors, Jumpers etc complete all as specified and directed.
S&F on load change over switch in sheet steel enclosure with front handle, 200 Amps, 4 Pole, 415 Volts, 50 Hz, including thimbles, nuts, bolts etc, complete, including taking down old unserviceable change over switch, all as specified & as directed. Make : L&T Cat Part No. CO22000OSOO or Havells/Indoasian/C&S
S&F on load change over switch in sheet steel enclosure with front handle, 315 Amps, 4 Pole, 415 Volts, 50 Hz, including thimbles, nuts, bolts etc, complete, including taking down old unserviceable change over switch, all as specified & as directed. Make : L&T Cat Part No. CO33150OSOO or Havells/Indoasian/C&S
Treeming of trees branches both side 3.00 metre wide of LT over head line and HT over head line during the treeming first take proper shutdown by informing the concerned JE (E/M) and Engr-in-Charge. Note : 3/4 wire LT over head and HT over head line shall be measured & paid as one running metre.
Disconnecting, dismantling & taking down old unserviceable LT Panel with fixtures and Supply & installation, testing & commissioning in replacement of LT cubical panel board of outdoor type comprising of 4 Nos copper bus bar capacity 500 Amp, including multi functional digital meters to read volage, current frequency, hooter and power factor, having individual compartment type made out of MS sheet 3.15mm thick and angle iron frame of 40x40x6mm thick including mounting legs of same angle iron 50cm long embedded in PCC foundation 1:2:4 type B-1 complete suitable for 3 phase 415 volt dust and vermin proof both side openable with locking arrangement, proper slanting projection and having required cable entry glands of suitable size including stud type aluminium cable lugs for incoming and outgoing cables of suitable sizes including painting of LT cubical panel with two coats of emameled paint over a coat of red oxide zinc chrome primer complete all as specified and directed with and including the following:- (a) Copper bus bar capacity 500 Amp - 01 Set (b) MCCB, 4 Pole, 315 Amps rating, rupturing capacity 36 kA, 415 volt grade, AC, 50 Hz, thermal Magnetic fixed type, Make : Indoasian Cat Part No. 830175 - 01 No (In coming)
Disconnecting, dismantling & taking down old unserviceable LT Panel of any size & capacity with fixtures and Supply & installation, testing & commissioning in replacement of LT cubical panel board of outdoor type comprising of 4 Nos copper bus bar capacity 600 Amp, including multi functional digital meters to read volage, current frequency, hooter and power factor, having individual compartment type made out of MS sheet 3.15mm thick and angle iron frame of 40x40x6mm thick including mounting legs of same angle iron 50cm long embedded in PCC foundation 1:2:4 type B-1 complete suitable for 3 phase 415 volt dust and vermin proof both side openable with locking arrangement, proper slanting projection and having required cable entry glands of suitable size including stud type aluminium cable lugs for incoming and outgoing cables of suitable sizes including painting of LT cubical panel with two coats of emameled paint over a coat of red oxide zinc chrome primer complete all as specified and directed with and including the following:-
Note for Serial item No. 9.00 to 11.00 (Contd...) (i) LT panel base frame shall be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate. The base shall be 60cm height from the nearest road level/floor level or as directed. (ii) All incoming MCCB shall be connected through MCCB spreaders with incoming bus bar and incoming cable shall be connected with incoming bus bar. (iii) Drawing of LT Panel shall be got approved well in advance from Engineer-in-Charge before fabrication of LT Panel. (iv) The quoted rate shall deemed to include supply & provision of 65mm lock with 2 keys. Make of Lock : Godrej / Harrison / Link. (v) Cost of platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration if required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
S&F MCCB, 4 Pole, 630 Amps rating, rupturing capacity 50 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Indoasian Cat Part No. 830408 or Havells/Siemens/ABB/Legrand.
S&F MCCB, 4 Pole, 400 Amps rating, rupturing capacity 50 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Indoasian Cat Part No. 830406 or Havells/Siemens/ABB/Legrand.
S&F MCCB, 4 Pole, 250 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Indoasian Cat Part No. or Havells/Siemens/ABB/Legrand.
S&F MCCB, 4 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Indoasian Cat Part No. 830335 or Havells/Siemens/ABB/Legrand.
S&F MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Indoasian Cat Part No. 830334 or Havells/Siemens/ABB/Legrand.
S&F MCCB, 4 Pole, 125 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Indoasian Cat Part No. 830273 or Havells/Siemens/ABB/Legrand.
S&F MCCB, 4 Pole, 100 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Indoasian Cat Part No. 830272 or Havells/Siemens/ABB/Legrand.
S&F MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Adustable thermal Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Indoasian Cat Part No. 830240 or Havells/Siemens/ABB/Legrand.
M&L for fixing of PVC LT line seperator on existing LT over head line to create gap between the line complete all as specified and directed. Note :- Necessary T&P as required like ladder/vehicle etc shall be arranged by the contractor for fixing the PVT LT line seperator.
M&L for preparation of steel surfaces for electric poles RCC LT/HT and apply one coat of aluminium paint and making of pole number and five strips each 30cm wide in Navy blue and white colour using synthetic enamel paind upto 1.50mtr height from top of PCC foundation block complete all as specified and directed. Make of Paint : Asian/Narolac/Burger.
M&L for preparation of steel tubular pole four pole structure and two pole structure and apply one coat of aluminium paint and making of pole number and five strips each 30cm wide in Navy blue and white colour using synthetic enamel paind upto 1.50mtr height from top of PCC foundation block complete all as specified and directed. Make of Paint : Asian/Narolac/Burger.
M&L for surface excavation and spreading of new aggreages of size 40mm evenly inside the inside the transformer yard area, and remove the all debris, hard soil upto a depth of 40cm manually with causing damage to the LT/HT under ground cables of any size and in the presence of under ground cable loop carefully clearing the area with out using excavating tools like crowbar, spades, showel etc and depositing excavated earth to a distance not exceeding 50 m complete all as specified and directed.
S&F in replacement of timer switch box fabricated made of 16 SWG CRCA sheet with mounting and locking arrangement duly powder coated consisting of following:- (a) Timer Make L&T Cat Part No. T2DDT7 or equivelant Legrand/Havells/Seimens - 01 No (b) Power contactor 63 Amps Make : L&T Cat Part No CS97076 - 01 No (c) Connector 100 Amps 230 volts - 03 Nos (d) MCCB 03 Pole, 30 to 63 Amps, 415 volts, Make : Indo Asian Cat Part No. 830240 - 01 Nos (e) Control fuse 2 Amps - 01 Nos
Surface dressing upto 15 cm deep surrounding of electrical instalation, HT/LT pole, street light pole / stay including cutting and cleaning away grass, bushes, small plant, vegetable shrubs, bushes of under roots complete all as specified and directed by Engr-in-charge.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for laying of cables, pipes, erection of poles, structs/stays etc not exceeding 10 sqm and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches not exceeding 1.50 metre wide and exceeding 1.5 metre but not exceeding 3.00 metre in depth for foundation etc or for laying of cables, pipes, erection of poles, structs/stays etc not exceeding 10 sqm and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
M&L for stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
M&L for dry sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 95 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
M&L for Pre Stressed concrete Pole 9.00 mtr long, 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm wide each upto 1.5mtr height from top of PCC foundation block and numbering of poles, including disconnecting & taking down old unserviceable corroded steel tubular pole/ broken RCC Pole complete all as specified and directed
M&L for PCC (1:4:8) Type D-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
M&L for plain cement concrete (1:3:6) Type C-2 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
S&F stay assembly complete with accessories as shown on electrical plate No 1 of SSR Part-I with 20mm dia 1.80 mm long stay rod, 300mm x 300mm x 6mm thick stay plate, complete all as specified including taking out old unserviceable stay assembly complete all as specified and directed. Note:- Loop insulator, clamp, stay wire, PCC and excavation & earth work shall be measured and paid for separately.
M&L for making earthing pit on existing old earthing where pit is completely damaged including cover 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm in lieu of CI cover, PCC 1:3:6 type C2 pit/chamber including all necessary excavation and earth work complete all as directed.
M&L for making earthing pit chamber cover on existing old earthing of 80mm thick pre-cast RCC (1:2:4) type B-1 reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated copper stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cables 4 Sqmm including taking down old unserviceable cable complete all as specified.
S&F 1100 volts grade heavy duty cable PVC insulated copper stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables 6 Sqmm including taking down old unserviceable cable complete all as specified.
S&F 1100 volts grade heavy duty cable PVC insulated copper stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire two single core cables 10 Sqmm including taking down old unserviceable cable complete all as specified.
M&L for earthing to electric equipments/panels with and including galvanized MS earth plate electrode of size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5m below ground level as shown in electrical plate No 3 of SSR Part I, the earth plate surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, excavation & earth work in any type of soil and removal of surplus soil upto 50m including galvanized mild steel strip 25mm x 4mm as earth lead, welding at top of electrode and other end of strip connected to equipment body/ panel/ test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 3.00 metre above ground level fixed along equipment body/panel with and including 25x3mm FI clamps, bolts, nuts and washers, PCC chamber (1:3:6) type C1, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering, 75 mm thick RCC cover 1:2:4 type B1 shall be provided on CI frame etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
S&F in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 6mm copper strip complete all as specified. Note : Nut, bolt and other items included in quoted rate by the tenderer.)
Supply and fixing in repair earth continuity copper strip 20mm X 3mm buried in ground and connected with copper strip by means of brazing or fixing it on wall complete all as specified.
Supply, installation, testing and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 Volts & 50 Hz, system Delta Connection, Heavy Duty Cylindrical Capacitor of capacity 80 KVAR made out 3.15 mm thick CRCA sheet mechine pressed of suitable double door cubical type with front and rear openable with locking arrangement, automatic switch ON/OFF complete including taking down old APFC Panel complete all as specified and as directed with and including the following:- (a) Copper bus bar capacity 300 Amp, 04 Pole suitable size - 01 Set (b) MCCB, 4 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 volt grade, AC, 50 Hz, thermal Magnetic fixed type, Make : Indoasian Cat Part No. 830295 - 01 No
M&L for feeder pillers box factory made out door type made out of MS sheet (CRCA) of thickness not less that 3 mm. of size 150x65x90cm with copper bus bar strip 3 Nos of size 130cm in length 4cm in width and 5mm in thickness suitable for 11000 volt mounted on HT porcelain insulator, front opening door two leaf braced with hinged, mounted on 4 Nos of angle iron 50x50 mm duly welded with box and grouted in PCC block masonry (1:3:6) type C1 of size 30cmx30cmx 15cm set in CM 1:6. Top of box MS sheet duly bent in/slope, tapper with projection of 30 mm on all side, weather/ vermin proof with high quality of rubber beeding on panel door, cable entry arrangements at bottom includes earthing terminals 2 Nos at both side and painted with smoke grey stove enameled paint 2 coat over a primer coat all as directed by Engr-in-Charge.
Nvimal Engineer and Contractor
M/S JAGDAMBA ENTERPRISES
S.D. And Company
Leelashah Enterprises
star electricals
S.G.ENGINEERING COMPANY
M/s Shree Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .