Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
10 Jun 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SRDSTECSIG
14 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Form-2, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- "Any signalling work involving trenching, cable laying, termination and outdoor wiring. Note 1:- Tenderer maybe required to submit the schedule of those works completion/performance certificate of which have been submitted by him/her in support of 30 /40/ 60 % (as the case may be) criterion of similar nature of work.
14 conditions · 9 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
PAN Number to be attached.
Registered Office Address with contact no.
Detail of Bid Security paid, through only payment modes available on IREPS portal like net banking, debit card, credit card etc.
Mandatory undertaking regarding Employment/Partnership of Retired Railway Employees as per Clause No. 12 of Chapter-I as per Annexure- E.
Mandatory certificate to be submitted by tenderer along with tender documents as per Annexure- A.
GST Number to be attached.
Mandatory Power of Attorney to be submitted by tenderer along with tender documents as per Annexure- B.
MOA & AOA, Resolution of Board and POA, Sole Proprietorship, Notarized partnership deed with POA and latest certificate of registration with Registrar of the firms must be attached. Year of Formation / Incorporation. (As per Clause-10 of Tender Document
Upload duly filled and signed Cover Letter (Tender Form 1)
Mandatory Document Tenderer uploaded Annexure-A (1) {This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF)/Limited Liability Partnership (LLP) etc.)}of tender documents.
An undertaking by the tenderer shall be provide at the time of tender submission that the equipment shall be procured from RDSO/TEC/OEM covering supply, installation, testing, commissioning of system including after sales support required during the warranty period.
S&T work in Connection with Elimination of Level Crossing No. 50,53,55,60 (4 Nos.) by Construction of LHS (6.0 x 5.0 M) on NK section (by Pushing Method) and Elimination of LC 45 between MLDE-ASDE station by const of LHS/Rd underpass 7x 5 m on JP section.
558-Sig-16-M-Tender-1481
558-Sig-16-M-Tender-1481
Open
Works - General
12 Months
Delhi, Delhi
₹0
₹2.9 L
10 Jun 2026
18 May 2026
27 May 2026
91 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,43,96,823.22 | ||
| — | 50.00 | — | — | ||
| Wiring of relays in existing PI/RRI and at LC Gates as per appd wiring diagrams and to suit Railway electrified area. All wiring material including resistances and condensers except cables/wires to be supplied by contractor (Supply of cables & wires covered separately). It also includes dressing, bunching, lacing and fixing of relay bases. (Inspection: Site Incharge) | — | — | — | 24,311.5 | |
| — | 6.00 | — | — | ||
| Laying of HDPE duct in the trenches, including in HDD/Manual Boring and supply pulling of Nylon rope through is at different places as per direction of Engineer incharge/ site Engineer. It includes Supply of HDPE duct outer diameter 40mm & inner diameter 33mm as per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment with end cap to be provided along with the drum at both ends. (RDSO specs No. RDSO/SPN/TC/45/2013 revision 2.0) Payment of this item will be made after laying only. Inspection: Consignee. | — | — | — | 4,51,880.64 | |
| — | 8.00 | — | — | ||
| Supply and installation of End plug for OFC. Inspection: Site Engineer | — | — | — | 275.28 | |
| — | 8.00 | — | — | ||
| Supply and installation of Cable sealing plug for OFC. Inspection: Site Engineer | — | — | — | 347.84 | |
| — | 8.00 | — | — | ||
| Supply and installation of Plastic Coupler- Slip fit/ Push fit type for OFC. Inspection: Site Engineer | — | — | — | 698.88 | |
| — | 6.00 | — | — | ||
| Blowing/ Drawing of OFC cable in the HDPE duct by mechanical system. Inspection: Site Engineer | — | — | — | 70,029.96 | |
| — | 29.00 | — | — | ||
| Supply and installation of optical fibre cable joint enclosure as per TEC spec no. GR/OJC-02/01/March 99 with latest amendment and splicing of optical fiber cables (24 fibers and testing). This includes provision of joint pit (RCC/Prefabricated) as detailed in the technical specifications and as advised by Engineer at site. Inspection: Consignee | — | — | — | 5,57,826.6 | |
| — | 24.00 | — | — | ||
| Supply & Installation of Thermo shrink jointing kit for 6-Quad/4-Quad cable for straight through joints as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. Inspection: RDSO for supply portion. | — | — | — | 1,86,369.84 | |
| Laying of signalling/Telecom/power cables of different sizes as per approved Drawing. No. NR/S&T/CON/1-1/97A and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Inspection: Site Engineer. | — | — | — | 2,85,600 | |
| — | 5000.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per approved Drawing. No.NR/S&T/CON/1-1/97A. Aso as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of roots of trees & bushes. Inspection: Site Engineer. | — | — | — | 4,31,550 | |
| — | 600.00 | — | — | ||
| Excavating and refilling of trench in Rocky soil to the level of ground with rammed earth as per approved Drawing. No.NR/S&T/CON/1-1/97-A1 so as not to form a drain 0.3 Mtrs. Wide & 0.5Mtr. Deep on both side of the station alongside the track. This includes 50mm thick concreting work throughout in 1:3:6 ratio. All concreting material to be supplied by the contractor. It shall conform to the safe distance as per signalling and cable plan It also includes clearance of routes of trees & bushes. Inspection: Site Engineer. | — | — | — | 79,812 | |
| Supply and laying of 2nd class bricks in the trench and laying as per approved Drawing. No.NR/S&T/CON/1- 1/97A as per instructions of the site Engineer. Inspection: Site Engineer. | — | — | — | 3,54,000 | |
| — | 1200.00 | — | — | ||
| HDD Boring & Trenchless of 120mm diameter without HDPE pipe for laying of signalling/ telecom / power cable under Track /Road/Culvert etc. cable laying is covered separately. Inspection: Site Engineer. | — | — | — | 11,59,680 | |
| — | 600.00 | — | — | ||
| Supply and fixing of G.I. pipe perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per drawing. No. (NR/S&T/CON/1. 4/97) or at ASM office / other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. G.I. pipe 75/80 mm diameter, 3mm thick. Inspection: RITES | — | — | — | 5,64,276 | |
| — | 6.00 | — | — | ||
| Supply of single apparatus case steel RE with 'E' type lock and key ward no.42 and handle as per drawing. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alteration B. Inspection: Consignee. | — | — | — | 1,32,451.02 | |
| — | 6.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of single apparatus cases of size (1160mmx760mm) at surface and 650mm deep as per approved Drg.No.NR/S&T/CON/2-7/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor. App. Case single will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer | — | — | — | 34,742.64 | |
| — | 6.00 | — | — | ||
| Preparation of Apparatus Case single not involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts. This includes fixing of fuses, ARA terminal and fixing and jamming of cables with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non-deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer | — | — | — | 29,334.84 | |
| — | 6.00 | — | — | ||
| Supply of apparatus case steel RE half with E type lock and key ward no.42 and handle as per drg.no. RE/S&T/ALD/SK/220/82 and 221/82 with Alteration B Inspection: Consignee. | — | — | — | 98,781.42 | |
| — | 6.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of half apparatus cases of size (670mmx760mm) and 650mm deep as per Drawing. No. NR/S&T/CON/2. 8/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor. App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer. | — | — | — | 30,396.84 | |
| — | 6.00 | — | — | ||
| Preparation of Apparatus Case (location box) half involving wiring of relays. Preparation and fixing of bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal, Q series relays and other type of relays on square bars, fixing and jamming of cable with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification., non-deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer | — | — | — | 26,276.16 | |
| — | 14.00 | — | — | ||
| Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drawing. No. (NR/S&T/CON/6.4/97). The soil treatment shall be done as per std. practice. The item includes provision. of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipment as per the instruction of Engr. at site & IRSEM. Earthing connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per drawing. No. (NR/S&T/CON/6. 3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection: Consignee | — | — | — | 42,985.74 | |
| — | 2500.00 | — | — | ||
| Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also include dressing and lacing of cable on both ends. Proforma for testing and material for lacing to be supplied by the contractor. Inspection: Site Engineer. | — | — | — | 37,125 | |
| — | 2500.00 | — | — | ||
| Supply of ARA Terminal Block 25MM center M6 terminal made of PBT as per IRS spec. No.IRS-S75/2006 (Rev.2) & IRS drawing No. SA23741A(Alt.4), SA23745(Alt.5), SA-23746 & SA23756(Alt.3). Inspection: RDSO. | — | — | — | 1,81,425 | |
| — | 5.00 | — | — | ||
| Dismantling of lifting barrier/ gate leaves complete set along with winch, wire rope, boom locking arrangements. All dismantled material to be transported and stacked in the store of SSE/Sig/NNO at Delhi or Dy. CMM/SSB store depot at DLI or any other store of northern railway as per consignee. Note: - Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engineer. Inspection: Site Engineer. | — | — | — | 17,376.2 | |
| — | 7.00 | — | — | ||
| Dismantling and releasing of location boxes which includes all S&T fittings of electrical and mechanical, releasing of termination boards, relays, terminals, batteries, track feed chargers and other associated fittings installed therein complete with fittings. All dismantled material to be transported and stack in the store of Consignee or DY.CMM/SSB store depot at SSB/site supervisor or any other store of northern railway as per. Note: - Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Location Box). Inspection: Site Engineer | — | — | — | 5,375.51 | |
| — | 1.00 | — | — | ||
| Dismantling and releasing of S&T gears in ASM room, Battery room, relay room, equipment room, DG room (including DG sets). This include all equipment and relays, relay rack, terminal board, SM Slide frame, panel batteries, battery chargers, angle iron, etc. all materials are to be transported and stacked in the store of Consignee at Delhi or Dy. CMM/SSB store depot at DLI or any other store of northern railway as per consignee. (Job = Per Room). Note: - Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. | — | — | — | 12,412.98 | |
| — | 2.00 | — | — | ||
| Dismantling and releasing single signal post which includes dismantling of signal fittings electrical and mechanical both wheel of sorts, GI pipe pullies, pully stakes wire run from cabin to signal posts etc. All dismantled material to be transported and stack in the store of Consignee or DY.CMM/SSB store depot at SSB/site supervisor or any other store of northern railway as per. Note: - Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.1 Job= 1 Signal). Inspection: Site Engineer | — | — | — | 2,774.5 | |
| — | 150.00 | — | — | ||
| Earth work for excavation and refilling around location boxes, signals etc. where necessary including 50m lead and 1.5m lift by excavation. The earth shall be rammed including breaking of clods, levelling and dressing. The earth work around the location/junction boxes/signals shall be up to the plaster level and for width sufficient for the maintainer to attend the box both from front & back side. Inspection: Site Engineer | — | — | — | 20,619 | |
| — | 30.00 | — | — | ||
| General concrete work in cement, coarse sand and aggregate ratio 1:3:6, work scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4. Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. Inspection: Site Engineer | — | — | — | 90,442.5 | |
| — | 4.00 | — | — | ||
| Supply of cable fault locator for underground cable as per model no. Telscout TS- 90(Test signal output 1/2 Sine, Pulse width 5nsec to 2500 nsec, Max range:1500m, Filter cut off frequency :150 Khz (High Pass Filter), Gain :0 to 63db), Stanlay or similar branded make as per specification. Inspection: Rites | — | — | — | 14,18,831.6 | |
| — | 5.00 | — | — | ||
| Supply and testing of electronic Cable Route Locator/Tracer equipment capable of tracing electronic markers and different types of underground signalling/ electrical cables of suitable make: (1) Receiver seek tech line locator/Cable avoidance tool 01 No. (2) Transmitter /Signal Generator complete with earth stake and connection leads.01 No. (3) Inductive signal clamp.01 No (4) Carry bag 01 No. Inspection by RITES. | — | — | — | 17,71,797.25 | |
| — | 8.00 | — | — | ||
| Supply of Megger 500V DC Philips or similar make. Inspection: Consignee | — | — | — | 34,069.76 | |
| — | 8.00 | — | — | ||
| Supply of Digital Insulation Tester (Megger) 100V, Motwani, Philips or equal to make. Inspection by- Consignee. | — | — | — | 50,078.96 | |
| — | 7.00 | — | — | ||
| Supply of Portable digital auto range multi-meter clamp type Philips, Motwani, Fluke or Rishabh make capable to measure from (0.1mv/0.01ma) AC/DC up to 50Amp (AC/DC), 600V(AC/DC) and 0.1 ohms- 40M ohms suitable for measurement of Freq., capacitance complete with Manual, leads, battery and holster etc. Inspection: Consignee | — | — | — | 62,499.57 | |
| — | 7.00 | — | — | ||
| Thermal vision Camera ACCEPTED MAKE MODEL CEM MAKE MODEL DT-9897 or similar/better. Inspection: Consignee. | — | — | — | 13,19,948 | |
| — | 200.00 | — | — | ||
| 35 Sq mm Multi-strand Single Core PVC insulated Copper Cable as per IS: 694 for connecting Main Earth Electrode to MEEB in the equipment room. Earth Color: Green. Inspection: RDSO. | — | — | — | 69,644 | |
| — | 5.00 | — | — | ||
| Supply of SSDAC Track Device Receiver & Transmitter RX/TX Coil assembly suitable for SSDAC GG Tronics Make. Inspection: RDSO. | — | — | — | 1,76,965.25 | |
| — | 1140.00 | — | — | ||
| Replacement of defective 6 quad cable and defective joints of 6 quad cable: (a) Excavation of jointing pit up to depth of 6 quad cable with the help of jointing kit & back filling of jointing pit (Jointing Kit will be supplied by railway). As per the instructions of Site Engineer. Inspection: Site Engineer. | — | — | — | 23,87,285.4 | |
| — | 11.00 | — | — | ||
| Supply of manual track drilling machine. Inspection: Consignee. | — | — | — | 94,761.92 | |
| — | 6.00 | — | — | ||
| Supply of Digital AC/DC low current Clamp meter model KOICO 3540 or similar or better. Inspection: Consignee. | — | — | — | 1,20,380.34 | |
| — | 100.00 | — | — | ||
| All work of horizontal boring and trenchless cabling along with supply, transportation and insertion of double wall corrugated pipe -( ISI marked) conforming to RDSO Spec no. RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road etc. as per instruction of site engineer. by using pipe of size 120 mm outer diameter, 103.5 mm inner diameter in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. Inspection: Consignee. | — | — | — | 2,18,925 | |
| — | 20.00 | — | — | ||
| Supply, Installation & Commissioning of maintenance free earth suitable kit as per RDSO Specification no. RDSO/SPN/197/2008 and Drawing No. SDO/. /E&B/001 dated: - 19.09.2008 and Drawing No. RDSO/SDO/. /E&B/002 dated: - 19.09.2008. Earthing kit consisting of earthing electrode of 17mm diameter as 3m long -01 no 2 MEEB (300mmx25mmx6mm) -o1 no. 3. SEEB (150mmx25mmx6mm) -01 no 4. Earth enhancing compound - 30 kg (minimum). This includes: - Provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data Logger etc. with PVC earth wire of size 25/35 sq.mm through copper lugs of suitable size PVC earth wire shall be supplied by contractor. Note: At certain locations, it may not be possible to acheive earth resistance of less than 1.0 ohm with one earth electrode /pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done, for interconnection of two earth pits copper tape of size 25x2 sq.mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Inspection: RDSO for supply portion. | — | — | — | 5,17,457.4 | |
| — | 2.00 | — | — | ||
| [Supply of managed SDH (STM-1 Add/Drop MUX land upgradeable to STM-4) fully wired for 2 X 63 MB and equipped for 21E1s and a Virtual Container (VC)-12 with STM-1(L1.1) aggregate interface including power supply, order wire, Ethernet card, sub rack, inbuilt DDF, installation material and all other accessories, manuals etc. as per TEC. Specification GR SDH 04/02, March 02 or with latest amendment. The contractor will supply all other accessories as mentioned in the labove said TEC Specifications and system will have provision of different redundancy cards as per the TEC Specifications. Note: It shall be possible to increase capacity from 21E1 to 63 E1s by adding / inserting tributary cards. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH equipment with all cards to the 48V Bus including supply of wires land connectors. Termination of all E1s on DDF taking PVC cable over runway or a wall. At the terminal station, one port may be disabled if required as per instructions given by site engineer in charge. Inspection: Consignee. | — | — | — | 4,35,464.44 | |
| — | 10.00 | — | — | ||
| Supply of Office table, laminated top, size minimum 4 ft x 5 ft, make Godrej/Durian/Methodex/President or of similar reputed make. (Inspection by consignee). | — | — | — | 1,13,129.4 | |
| — | 30.00 | — | — | ||
| Supply of Chair, superior quality, size 57D x 58W x 88H and seat height 45 mm, make CH-7 (Godrej)/Geeken make. (Inspection by consignee) | — | — | — | 80,745.9 | |
| — | 2.00 | — | — | ||
| Supply of 2 Mb Programmable Primary Digital drop insert multiplexer as per RDSO Specs. IRS TC- 68/2004 (Amnd.1) or latest with conference facility and other stipulation to tender documents and fully wired for 30 channel complete with power supply card, remote control, supervision facility and all other accessories, installation material, manuals etc. It should have facilities to accommodate data interface card in multi drop mode and should be able to support cards needed for video conferencing and ISDN. It shall support NMS installed at Test Room and may operate local/remote location of entire section. It also includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and commissioning of system. The above MUX should be equipped with following circuits: - i) 2 wire/ 4 wire E&M VF circuits (minimum 16 nos. circuits) ii) Subscriber loop circuits (minimum 4 nos. circuits) iii) Exchange loop interface circuits (minimum 8 circuits) iv) This also includes connecting all pigtails, optical patch cords etc. to the SDH equipment's. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including supply of wires and connectors termination of all evens on DDF taking PVC cable over runway or a wall and termination of VF interface circuit to the Krone type. INSPECTION: RDSO FOR SUPPLY PORTION. | — | — | — | 5,95,661.14 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
splinstruction.pdf
ATTACHMENT
Tender-Doc-1481_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .