Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.6 L+₹3.7 L (23.2%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹21.4 L+₹5.4 L (34.2%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹21.5 L+₹5.6 L (35.4%)Rejected-Finance JAJJAR KOTLI JAMMU J K 151222 | JAMMU | JAMMU | J K | 151222 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹22.6 L+₹6.7 L (42.1%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
17 Feb 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Repair/Maintenance of DG Sets and related works in electric sub division under GE Utilities Udhampur
2020_MES_315007_1
GE/U-57/2019-20
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE UTILITIES UDHAMPUR
₹49,000
Yes
15 Apr 2020
15 Jan 2020
18 Feb 2020
15 Jan 2020
17 Feb 2020
3 Feb 2020
Amount
M&L for dismantling /opening of alternator by disconnection of cable connections and flexible coupling, nuts/bolts and alternator foundation nut, bolts including strip opening of alternator and checking burnt parts of DG Sets of capacity 125 KVA to 250 KVA and take back in temporary platform complete all as specified and directed by Engr-in-charge.
Taking out burnt armature, winding wire and rewinding the armature with super enamelled copper winding wire of existing gauge of DG Sets of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
M&L for insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature of DG Sets of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
M&L for insulation of field coils with Class ‘B’ insulation and Varnishing of field coil winding and drying up to desired temperature of DG Sets of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
Re-assembling of rotor and starter after rewinding and re-fixing of alternator with Engine by assembling flexible coupling with alternator, mounting with nuts & bolts including making cable connection complete including testing and commissioning at desired load of DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
M&L for dismantling /opening of radiator by upper & lower tank, soldering all radiated tube as per requirment, cleaning the radiator with the help of soda/acid or chemical , including opening of blockage part and checking burnt parts of DG Sets of capacity 62.5 KVA to 250 KVA and refixing the same in existing position complete all as specified and directed by Engr-in-charge.
Servicing of DG sets by cleaning and taking out sump oil complete all as specified and directed by Engr-in-charge. Note: Oil 15W/40 shall be measured and paid separately under relevant item.
S&F for in replacement of sump oil drain cock as per existing, suitable for 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F in replacement of fuel filter (primary & secondary) of DG set of capcity 62.5 KVA to 250 KVA Cat Part No 4900276 of Make Cummins or equivalent as approved by GE complete all as specified and directed by Engr-in-charge.
S&F in replacement lubricant oil filter of DG set of capcity 62.5 KVA to 250 KVA Cat Part No 4900378 of Make Cummins or equivalent as approved by GE complete all as specified and directed by Engr-in-charge.
S&F in repalcement of battery 12 volt 180 AH. complete including necessary connection complete all as specified and directed by Engr-in-charge.
S&F in replacement of fan belt as per existing size of DG set of capcity 10 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of battery terminals of batteries of capacity upto 12 Volt 180 AH including nuts and bolts of DG sets of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge. Cat Part No. 000090702105 (2N) of Greaves or equivalent as approved.
S&F for replacement of battery terminals of batteries of capacity upto 12 Volt 180 AH including nuts and bolts, of DG sets of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge. Cat Part No. 000090702106 (2P) of Greaves or equivalent as approved.
S&F for replacement of injector assembly for DG sets of capacity 62.5 KVA to 250 KVA as per sample or suitable to match with existing of make Kirloskar or equivalent as approved.
S&F for replacement of injector leak fuel pipe for tank (Six cylinder) both side for DG sets of capacity 62.5 KVA to 250 KVA as per sample or suitable to match with existing of Make Kirloskar or equivalent as approved .
S&F for replacement of stop solenoid assembly for S12 VDC micro pump (single coil) heavy duty electrical control make energise to stop of DG sets of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge. Cat Part No 6H.266.30.0.00 of kirloskar or equivalent as approved.
S&F in repalcement of battery cable lead (copper) positive with terminal size 35 Sqmm (198cm long) as per sample.
S&F in repalcement of battery cable lead (copper) negative terminal size 35 Sqmm (198cm long) as per sample.
S&F in repalcement of inter connection battery cable lead (copper) with terminal size 35 sqmm (30cm long) as per sample.
S&F for replacement of automatic voltage regulator suitable for DG Sets of capacity 63 KVA & 100 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of automatic voltage regulator suitable for DG Sets of capacity 125 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of flexible pipe M30 with union on both side,1400mm long for DG sets of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for repalcement of drain pipe of DG sets of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge. Cat part No 6H.1187.02.0.00 of Make Kirloskar or equivalent as approved.
S&F for replacement of Carbon brush of DG Sets of capacity 63 KVA to 250 KVA (set of three) as per sample complete all as specified and directed by Engr-in-charge.
Supply of engine oil 15 W 40 in sealed drum and filling in oil sump of DG sets complete all as specified and directed by Engr-in-charge.
S&F for replacement of lubricant oil temperature gauge of DG Set complete all as specified and directed by Engr-in-charge. Cat Part No. 105681020014 of Greaves or equivalent as approved.
S&F for replacement of oil pressure gauge flexible pipe of DG sets of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge. Cat Part No. 1045612412001 of Greaves or equivalent as approved.
S&F for replacement of Hose flexible suitable for DG sets of capacity 62.5 KVA to 250 KVA . Cat Part No 3944458 of Make Cummins or equivalent as approved.
M&L for replacement of fuel feed pump of DG sets of capacity upto 250 KVA Cat Part No 3006011000 of Make Kirloskar or equivalent as approved complete all as specified and directed by Engr-in-charge.
M&L in replacement of water temperature gauge of DG set (as per sample) complete all as specified and directed by Engr-in-charge.
M&L for replacement of flexible fuel pipe of DG set complete all as specified and directed by Engr-in-charge. Cat Part No. 123200194307 of Greaves or equivalent as approved.
M&L for replacement of wire braided fuel flexible pipe of DG set of capacity 62.5 to 500 KVA complete all as specified and directed by Engr-in-charge. Cat Part No. 100099391044 of Greaves or equivalent as approved.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
S&F GI strip of size 32mm x 6mm with suitable nuts and bolts complete all as specified and directed by Engr-in-charge.
M&L for dismantling of broken door of sound proof canopy of the DG Set of capacity ranging from 63 KVA to 250 KVA and taking it to the nearest workshop for repairing the door with new hinges,nuts and bolts etc and re-assembling the same at existing position and testing for proper opening and closing of the door, including repair of the locking system of the door( if it is repairable) otherwise replacement of the locking system of the door. Note: Any cutting/drilling/welding work required to complete the entire job is deemed to be include in the quoted rate .
S&F for replacement of current transformer of ratio 100/5 Amps ( Set of three) complete all as specified and directed by Engr-in-charge.
S&F for replacement of current transformer of ratio 200/5 Amps ( Set of three) complete all as specified and directed by Engr-in-charge.
S&F for replacement of digital ampere meter of suitable range as per existing size complete all as specified and directed by Engr-in-charge.
S&F for replacement of digital voltmeter 0-500 volts as per existing size complete all as specified and directed by Engr-in-charge.
S&F for replacement of digital frequency meter as per existing size complete all as specified and directed by Engr-in-charge.
S&F for replacement of digital DC voltmeter digital type as per existing of DG sets of capacity 125 KVA to 250 KVA and refixing in existing position complete all as specified and directed by Engr-in-charge.
S&F for replacement of earth fault relay of DG sets of capacity 125 KVA to 250 KVA and refixing in existing position complete all as specified and directed by Engr-in-charge.
S&F for replacement of over current fault relay of DG sets of capacity 62.5 KVA to 250 KVA and refixing in existing position complete all as specified and directed by Engr-in-charge.
S&F for replacement of three phase OCR relay of DG sets of capacity 62.5 KVA to 250 KVA and refixing in existing position complete all as specified and directed by Engr-in-charge.
M&L for repair of battery charger alternator of size 12 V suitable for 62.5 KVA to 125 KVA including repair/replacement of Rectifier, Regulator, Carbon Holder, Field coil etc complete all as specified and directed by Engr-in-charge.
M&L for repair of battery charger alternator of size 24 V suitable for 125 KVA to 250 KVA including repair/replacement of Rectifier, Regulator, Carbon Holder, Field coil etc complete all as specified and directed by Engr-in-charge.
S&F for replacement of lid for Fuel tank suitable for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
Supply only Distilled water in sealed packed bottled/packed jar/cannies etc complete all as specified and directed by Engr-in-charge.
Supply only coolent in sealed packed bottled/packed jar/cannies etc complete all as specified and directed by Engr-in-charge.
Supply only cotton waste complete all as specified and directed by Engr-in-charge.
S&F for replacement of Emergency push button suitable for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
M&L for dismantling /opening of Injector assy for assy pressure testing, clean them with the help of Diesel & chemical , including changing internal part such as seams/shims and of DG sets of capacity 62.5 KVA to 250 KVA and refixing in existing position complete all as specified and directed by Engr-in-charge.
S&F in replacement of LOP Sensor suitable for 62.5 KVA DG set Model No: KG V2 (SF 4-20 mA LOP Sensor) generator controller complete all as specified and directed by Engr-in-charge. Make: Kirloskar/Eqvt.
S&F in replacement of actuator Elec governor Item code 3816004 HSN/SAC No 84099990 suitable for Cummins DG Sets of capacxity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge. Make: Kirloskar/Eqvt.
S&F in replacement of Annuciator meter for AMF panel 250 KVA DG set capacity including changing of all internal relays such as over load relay, canopy thermostate relay, common Fault relay,Emergency stop etc complete all as specified and directed by Engr-in-charge. Make: Kirloskar/Eqvt.
S&F for replacement of Copper washer 27 mm suitable for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Copper washer 19 mm for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Copper washer 17 mm for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Copper washer 12 mm for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Copper washer 10 mm for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Banjo Bolt 19 mm for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Banjo Bolt 14 mm for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Banjo Bolt 10 mm for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Tapped cover gas kit suitable for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Radiator Hose Pipe suitable for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Clamp for radiator Hose Pipe suitable for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of Radiator cap suitable for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F for replacement of minute Jally suitable for battery terminal for DG set of capacity 62.5 KVA to 250 KVA complete all as specified and directed by Engr-in-charge.
S&F in replacement MCCB 4 pole , 37 KA, 415 Volts, 400 Amps ,Ics=100%Icu with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement MCCB 4 pole , 37 KA, 415 Volts, 250 Amps ,Ics=100%Icu with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement MCCB 4 pole , 26 KA, 415 Volts, 200 Amps ,Ics=100%Icu with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement MCCB 4 pole , 26 KA, 415 Volts, 160 Amps ,Ics=100%Icu with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement MCCB 4 pole , 18 KA, 415 Volts, 100 Amps ,Ics=100%Icu with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F ON LOAD chang over switch 415V in sheet metal enclosure 4 pole of capacity 630 Amps complete all as specified and directed by Engr-in-charge.
S&F in replacement on load change over switch of capacity 400 Amps, four pole,front operated with advance neutral, 415 volts, 50 HZ conforming to IS-13947-3 complete all as specified and directed by Engr-in-charge.
S&F in replacement on load change over switch of capacity 250 Amps, four pole,front operated with advance neutral, 415 volts, 50 HZ conforming to IS-13947-3 complete all as specified and directed by Engr-in-charge.
S&F in replacement on load change over switch of capacity 200 Amps, four pole, front operated with advance neutral, four pole, 415 volts, 50 HZ conforming to IS-13947-3 complete all as specified and directed by Engr-in-charge.
S&F in replacement for on load change over switch of capacity 100 Amps, side handle in steel sheet enclosure, four pole, 415 Volts, 50 Hz AC- 23 confirming to IS/IEC 60947-1 & 3 complete all as specified and directed by Engr-in-charge.
S&F for off load change over switch of capacity 400 Amps, side handle in steel sheet enclosure, four pole, 415 Volts, 50 Hz AC-21 confirming to IS/IEC 60947-1 & 3 complete all as specified and directed by Engr-in-charge.
S&F for off load change over switch of capacity 630 Amps, side handle in steel sheet enclosure, four pole, 415 Volts, 50 Hz AC-21 confirming to IS/IEC 60947-1 & 3 complete all as specified and directed by Engr-in-charge.
S&F in replacement of copper tube (Thimbles) terminal, heavy duty of size 185 Sqmm complete all as specified and directed by Engr-in-charge.
S&F in replacement of copper tube (Thimbles) terminal, heavy duty of size 150 Sqmm complete all as specified and directed by Engr-in-charge.
S&F in replacement of copper tube (Thimbles) terminal, heavy duty of size 120 Sqmm complete all as specified and directed by Engr-in-charge.
S&F in replacement of copper tube (Thimbles) terminal, heavy duty of size 95 Sqmm complete all as specified and directed by Engr-in-charge.
S&F in replacement of copper tube (Thimbles) terminal, heavy duty of size 70 Sqmm complete all as specified and directed by Engr-in-charge.
S&F in replacement of copper tube (Thimbles) terminal, heavy duty of size 50 Sqmm complete all as specified and directed by Engr-in-charge.
S&F in replacement of copper tube (Thimbles) terminal, heavy duty of size 35 Sqmm complete all as specified and directed by Engr-in-charge.
S&F for replacement of indicator lamp (LED type) fitting with neon lamp in three colour (Red/Green/Yellow) complete all as specified and directed by Engr-in-charge.
M&L for PVC insulated, industrial, copper conductor, unsheathed cable (flexible) single core, 1100 volts, 70 Sqmm complete all as specified and directed by Engr-in-charge.
M&L for PVC insulated, industrial, copper conductor, unsheathed cable (flexible) single core, 1100 volts, 120 Sqmm complete all as specified and directed by Engr-in-charge.
M&L for Mild steel, plain, black sheet 1.60 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as required complete all as specified and directed by Engr-in-charge.
M&L for two coats of synthetic enamal paint over a coat of red oxide primer to steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described including preparation of new or previously untreated surfaces complete all as specified and directed by Engr-in-charge.
Disconnecting/taking out existing unsrviceable/ damaged LT underground cable/service cable from trenches/ducts or from poles/walls or under roads/paths/drains/culverts and depositing the same in the MES storeyard or disposed off of size 120 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 95 here-in-before but of size 70 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 95 here-in-before but of size 35 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Supply, laying, jointing and testing of XLPE insulated, armoured heavy duty electric cable with aluminum conductor,multi stranded, 1100 volts grade of size 120 sqmm, 3.5 core laid in trenches/duct/pipe complete all as specified and directed by Engr-in-charge.
Supply, laying, jointing and testing of XLPE insulated, armoured heavy duty electric cable with aluminum conductor,multi stranded, 1100 volts grade of size 70 sqmm, 3.5 core laid in trenches/duct/pipe complete all as specified and directed by Engr-in-charge.
Supply, laying, jointing and testing of XLPE insulated, armoured heavy duty electric cable with aluminum conductor,multi stranded, 1100 volts grade of size 35 sqmm, 3.5 core laid in trenches/duct/pipe complete all as specified and directed by Engr-in-charge.
M&L in replacement for GI tubing ,40 mm bore, light grade including necessary clamps,bolts,nuts, washers duly painted for the protection of the cable laid in trenches/under road/path complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying /repair to pipe line and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Returning and filling in excavated soil including spreading levelling ,watering and well running in layers not exceeding 25cm thick complete all as specified and directed by Engr-in-charge.
Removing surplus excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning to UG cable laid in trenches with clean dry river sand obtained from the river complete all as specified and directed by Engr-in-charge.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed by Engr-in-charge.
S&F in replacement of MS Sheet 10mm thick to be welded on trolley meant for carrying of DG set/ transformer incl necessary cutting, welding/drilling work etc.including making smooth/good finishing etc complete all as specified and directed by Engr-in-charge.
M&L in replacement of M S angle iron 65x65x6mm as in protection of DG set/transformeron trolley, MS flat iron, MS bar along with reqd bolt, nuts washer complete all as specified and directed by Engr-in-charge.
Supply only Chain link MS galvanisd fencing with 100x100mm square mesh size of wire 3.15/4mm any size or type including line wire any mesh, size and type complete all as specified and directed by Engr-in-charge.
Fixing only in replacement chain link fencing including line wire any mesh size and to any type of standards , rails, straining bolts, etc including provission of binding wire complete all as specified and directed by Engr-in-charge.
M&L painting steel and iron surface of any description over 10cm in width or girth, not otherwise described preparation of new or previously un-treated surfaces ,one coat of primming with red oxide zinc chromeand two coat of aluminium paint complete all as specified and directed by Engr-in-charge.
M&L for M S framed work as in door or wicket gates of angle or other section with M S bar, gusset plate, rails, braces, including welding/ drilling work complete (exclusive of steel sheeting or other covering , running rail and guides) and hanging; also fastening and fixing including taking down existing MS framed work complete all as specified and directed by Engr-in-charge.
M&L MS sliding door bolts 200mm long , plate type, stove enamelled block, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on staple plate and fixed including taking down existing sliding door bolt complete all as specified and directed by Engr-in-charge.
S&F M S butt hinges 125mm long medium weight cold rolled mild steel fixed complete all as specified and directed by Engr-in-charge.
ARNABH ASSOCIATES
TARA ENTERPRISES
BARU ENTERPRISES
R K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .