CE AF UDHAMPUR ZONE
HQ CE AF UDHAMPUR ZONE
CA NO CEAFU-02-2023-24 PROVN OF UNDER GROUND SUMPS AT LALGOAN PUMP HOUSE FOR STORAGE OF FRESH WATER UNDER GE P AF SRINAGAR
2023_MES_588770_1
CEAFU-02/2023-24
Open Tender
Civil Works
Item Rate
366 days
Lalgoan Srinagar
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹2,000
GE P AF Srinagar
₹3.7 L
Yes
CE AF UDHAMPUR ZONE
31 Aug 2023
10 Apr 2023
12 Jul 2023
10 Apr 2023
4 Jul 2023
15 Jun 2023
10 Apr 2023 - 24 Apr 2023
25 Apr 2023
Amount
SCHEDULE `A' PART-I (BUILDING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Construction of RCC under ground Sump of 50000 gallons capacity with permanent specification complete all as specified & as shown on drawings (at Lalgaon Pump house & Filtration plant).
Construction of block of Pump house bldg size 10.96m x 6.96m including jack well , single storey, framed structure Galvalume sheet roof including shutter etc with permenant specification complete all as specified and shown in drawings.
Construction of block of Pump house bldg size 8.46m x 5.46m, single storey, framed structure Galvalume sheet roof including shutter etc with permanent specification complete all as specified and shown in drawings.
Total amount of Schedule 'A' PART-I (BUILDING WORK)
Total amount of Sch 'A' PART-II (SEC-I) (INTERNAL ELECTRIC SUPPLY WORKS)
Sch 'A' PART-II (SEC-II) (INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing of Exhaust fan 200mm sweep, heavy duty motor with double ball bearing, PVC body with PVC louvers, 900 RPM, With bird guard to protect the fan in running condition, AC, single phase, 230 Volts, including connection with 1.5 Sqmm mutistrand copper conductor flexible wire from ceiling rose, including outside louvers with proper hole, and necessary fixing arrangement and making good to disturbed surface complete all as specified and directed.
Supply and fixing LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <20W, luminaire lumen >2000 lm, system efficiency of > 120 lumens/W, LED Make : Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM70 & LM 80 certification all as specified and directed.
Supply and fixing 2ft x 2ft recess mounted full panel LED luminaire with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser , in built electronic driver duly wired up to terminal block, power consumption< 36W, luminaire lumen > 3500lm and system efficiency >120lm/W, CRI>80, LED Make:- Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, colour temp -5700K, Ingress protection IP 20, , driver efficiency >85%, 50,000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor >0.95, THD < 10% , surge protection in CM -3 KV, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard, with LM79 & LM80 certification all as specified and directed.
Total amount of Sch 'A' PART-II (Section-II) (INTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' PART-III (CHEQUERED/CONCRETE PATH WORK)
Total amount of Sch 'A' Part-IV (AREA DRAINAGE WORK)
Total amount of Sch 'A' PART-V (Section-I) (EXTERNAL WATER SUPPLY WORK)
Sch 'A' Part-V (Section-II) (EXTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and lay in trenches ductile iron pipes, socket and Spigot ends, of size DN150 mm dia bore, ISI marked Centrifugally Cast (Spun) Ductile Iron Pressure pipes conforming to IS:8329/2000 classification K-9 rating with nominal wall thickness 6.0mm, suitable for push-on-joint(Rubber gasket-D jointing) with cement mortor lining inside the pipes and outside zinc coating with Bituminous finish coat as per IS:8329/2000 including EPDM rubber joints conforming IS: 5382 of 1985 all as specified and as directed by Engineer-in-charge.
Supply and fixing DI fitting for DI spigot and socketed / flanged ends pipes like bends (any type, radius and angle) increasing, decreasing or double socketed / flanged tee pieces single branch 'Y' junction double branch, cross collars caps and plugs, connecting pieces one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth suitable for up to 200mm bore pipe complete all as specified. Note :- (i) The weight of the fitting for the purpose of payment shall be actual weight of the fitting or as specified in IS code which ever is less. (ii) Unit rate per Kg inclusive of rate for Jointing materials such as rubber tyton joint .
Supply & fixing cast iron Sluice valve PN1.6, 300mm nominal dia, as per IS-14846 (2000), body, both ends flanged, dome, wedge-CI IS:210, rings-bronze IS:318, Spindle-SS IS: 6603, Gland Packing greasy jute packing, fasteners-CS, Gasket- Natural rubber complete all as specified and directed by Engineer-in-charge. Note : (i) Suitable size DI flange socket/DI flange spigot shall be measured separately under respective item. (ii) Necessary jointing materials such as gasket, nuts, bolts and washers shall be included under this item.
Supply and fixing high pressure, heavy duty ductile iron non return valve/ check valve of size 150mm nominal dia both ends flanged, swing type, PN 2 rating and other accessories as per IS 1538 complete all as specified and directed by Engineer-in-charge. Note : Suitable size flanges for pipe line, Joints and jointing materials shall be included under this item.
Supply and fixing cast iron Air release valve 80mm with double orifice type (small & large orifice), Kinetic type non clogging & self sealing balls for trouble free operation, totally tamper proof Ideally suited for turbid or clear water conforming to IS:14845/AWWA pressure rating PN 1.6 and jointing materials like gaskets, flanges, nuts and bolts and wahser etc complete for fixing arrangement in water pipes mains complete all as specified and as directed by Engineer-in Charge.
Supply, installation, testing and commissioning of Open well submersible monobloc pump with copper rotor suitable for raw/turbid water application suitable for 3 phase 415 volts, capacity 850 LPM at 15mtr head, size of inlet x outlet (65mm x 50mm) conforming to IS 14220 (1994) with stainless shaft, bronze bush and stamping lamination with high permeability steel for long life and increased efficiency, impeller cast iron. Insulation: B class Protection: IP 68. The cap of motor in HP/KW shall be as per recommendation of the manufacturer. The motor shall be conforming to IS: 9283 (1994) with minimum 69% efficiency and Guaranteed Pump efficiency at design flow should be equal or greater than 65% complete all as specified and as directed by Engineer-in-charge. NOTE: Prior approval of design and capacity as per specifications shall be obtained from GE before procurement.
Supply, installation, testing and commissioning of centrifugal pump set suitable for turbid water application with liquid temperature between 0°C to 40°C with horizontal spindle, bronze impellers with CS shaft and shaft sleeves having capacity of 760 LPM to lift raw water at head of 105 metres, nominal speed 1450RPM or as per RPM recommended by the manufacturer of pumping set, conforming to IS- 5120 (1977), directly coupled with squirrel cage induction motor of suitable capacity or KW as per recommendation of the manufacturer conforming to IS12615 (2011) and IS/IEC 60034-1 suitable for operation on AC three phase 415V ± 10%, 50 HZ, class F insulation, Duty: S1, S3 80% and above CDF, with premium efficiency standard IE3, IP 55, mounted on common base frame made out of suitable size MS Channels. Capacity of motor shall be decided after considering suitable derating factor as per tropical condition of Srinagar. Both Pump and motor mounted on and including common base frame on existing foundation and reconnecting existing suction and delivery pipe line.
Notes: (i) Base frame will be fixed on platform (ii) Size of platform including civil work are as per manufacturer recommendations. However rate shall be deemed to be included for the following: (a) Any Addition / Alteration of suction 100mm dia DI/GI/MS pipe and delivery side pipe of existing pipes and water connection etc. (b) Installation of strainer on suction side of suitable dia to match with suction pipe alongwith necessary arrangement of GI Pipe 20mm bore alongwith funnel and valve for release of air. (d) BLANK (e) Any other civil wk required at site. (f) Prior approval of design and capacity as per specifications shall be obtained from GE before procurement.
Supply, installation, testing and commissioning of centrifugal pump set suitable for clear water application with liquid temperature between 0°C to 40°C with horizontal spindle, bronze impellers with CS shaft and shaft sleeves having capacity of 1140LPM to lift clear water at head 90 meter, nominal speed 1450RPM or as per RPM recommended by the manufacturer of pumping set, conforming to IS- 5120 (1977), directly coupled with squirrel cage induction motor of suitable capacity or KW as per recommendation of the manufacturer conforming to IS12615 (2011) and IS/IEC 60034-1 suitable for operation on AC three phase 415V ± 10%, 50 HZ, class F insulation, Duty: S1, S3 80% and above CDF, with premium efficiency standard IE3, IP 55, mounted on common base frame made out of suitable size MS Channels. Capacity of motor shall be decided after considering suitable derating factor as per tropical condition of Srinagar. Both Pump and motor mounted on and including common base frame on existing foundation and reconnecting existing suction and delivery pipe line. Notes: (i) Base frame will be fixed on platform (ii) Size of platform including civil work are as per manufacturer recommendations.
However rate shall be deemed to be included for the following: (a) Any Addition / Alteration of suction 100mm dia DI/GI/MS pipe and delivery side pipe of existing pipes and water connection etc. (b) Installation of strainer on suction side of suitable dia to match with suction pipe alongwith necessary arrangement of GI Pipe 20mm bore alongwith funnel and valve for release of air. (d) BLANK, (e) Any other civil wk required at site (f) Prior approval of design and capacity as per specifications shall be obtained from GE before procurement.
Supply, installation, testing and commissioning of non clog submersible pump with radially split casing over hung non clog impeller which allows passage of solid up to 20mm suitable for drain/sewage water application suitable for 3 phase 415 volts, capacity 550 LPM at 10mtr head, double mechnical seal, high tensile steel shaft, cutter fan arrangement. Drive motor is dry type submersible Insulation: F class Protection: IP 68 as per IS 2147. The cap of motor in HP/KW shall be as per recommendation of the manufacturer. The motor shall be conforming to IS:9283 (1994) with minimum IE2 efficiency and Guaranteed Pump efficiency at design flow should be equal or greater than 65%. complete all as specified and as directed by Engr-in-charge complete all as specified and as directed. Note: Prior approval of design and capacity as per specifications shall be obtained from GE before procurement.
Supply and Fixing submersible pump cable of size 4.0 sqmm flat 3 core, XLPE insulated and sheathed with PVC, multi stranded copper conductor cable conforming to IS 694, 1100 volts grade and connecting complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing submersible pump cable of size 6.00 sqmm flat 3 core, XLPE insulated and sheathed with PVC, multi stranded copper conductor cable conforming to IS 694, 1100 volts grade and connecting complete all as specified and as directed by Engineer-in-charge.
Supply and fixing stainless steel chain, fabricated with SS-304 grade steel fixed to non clogging sewage pump complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of LT panel indoor type conforming of IS: 61439 1 & 2. totally enclosed dust and vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50 HZ AC supply with rated fault level 65 KA/1 S with internal arc containments, outer sheet shall be made out of 2.00mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc. Protection of enclosure IP 42 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. The panel shall be provided with manufacturer name plate, heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface.The panel shall be designed with arrangement for controlling of four motors complete and comprising of the following (Sludge Pump + Open well pump):-
(A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic, non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar. The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables. All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V, A, KW, KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three. (iv) MCB SP 6A 'C' series for control ckt protection = 03 Nos. (B). INCOMER (i) MCCB 40 amp 4 pole Icu = 16 KA at 415 volts, Ics =100% Icu with thermal magnetic release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator confirming to IS/IEC 60947 Part 2 - 01 nos
(C). OUTGOING (i) For Sludge Pump: Motor Protection Circuit breaker rotary type 2.2kW, 6.3 Amp adjustable thermal release range ,3phase AC conforming to IEC 60947-4-1,Breaking capacity Icu 100 KA and Rated service short-circuit breaking capacity Ics 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, at 440 V AC 50/60 Hz ,under voltage release ,Shunt release,IK09 enclosure,IP20 conforming to IEC 60529 with short circuit and overload protection facility complete all as specified -02 Nos. (ii) For Open well Pump: Motor Protection Circuit breaker rotary type 5.5kW, 13 Amp adjustable thermal release range, 3phase AC conforming to IEC 60947-4-1, Breaking capacity Icu 100 KA and Rated service short-circuit breaking capacity Ics 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, at 440 V AC 50/60 Hz, under voltage release, Shunt release, IK09 enclosure, IP20 conforming to IEC 60529 with short circuit and overload protection facility complete all as specified -02 Nos (iii) Start/Stop/Reset push buttons-12nos (03 nos for each motor) (iv) Phase indication/Motor ON/Motor OFF/Trip indicating lamps LED type -04 sets (02 sets each for sludge pump and open well pump) (v) Auxillary control relays -04 sets (vi) Surge Supressor 415 volts 20 KA -04 Nos (vii) Protections:- Phase failure, unbalance, phase sequence, overloading and dry running (under current) (viii) 3 pole Power contactors suitable size conforming to IS/IEC 60947-4-1 suitable for 3 phase 415Volts,50Hz AC supply with auxillary contact 1NO + 1 NC for motor operation -04nos or as per requirement of panel designer Note: The MPCB voltage rating must match the name plate voltage of the motor.
Note: (i) LT panel shall be shall be design verified as per IS/IEC 61439 1 & 2. (ii) Contractor shall submit the following type Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI for conformance to IS/IEC 61439- 1 & 2,65 KA 1 sec in respect of LT PaneL. (iii) Contractor shall submit drawing for approval prior to place order.
Supply, installation, testing and commissioning of LT panel indoor type confirming of IS : 61439 1 & 2. totally enclosed dust and vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50 HZ AC supply with rated fault level 65 KA/1 S with internal arc containments, outer sheet shall be made out of 2.00mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc.Protection of enclosure IP 42 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface.The panel shall be designed with arrangement for controlling of two motors complete and comprising of the following (Lalgoan Pump):-
(A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.
The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos (B). INCOMER (i) MCCB 125 amp 4 pole Icu = 16 KA at 415 volts, Ics =100% Icu with thermal magnetic release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos (C). OUTGOING (i) Motor Protection Circuit breaker rotary type 34kW, 63 Amp adjustable thermal release range, 3phase AC conforming to IEC 60947-4-1, Breaking capacity Icu 100 KA and Rated service short-circuit breaking capacity Ics 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, at 440 V AC 50/60 Hz, under voltage release, Shunt release, IK09 enclosure, IP20 conforming to IEC 60529 with short circuit and overload protection facility complete all as specified -02 Nos. (ii) Start/Stop/Reset push buttons -06nos (03 nos for each motor) (iii) Phase indication/Motor ON/Motor OFF/Trip indicating lamps LED type -02 sets (iv) Auxillary control relays -01 sets (v) Surge Supressor 415 volts 20 KA -02 Nos
(vi) Protections:- Phase failure, unbalance, phase sequence, overloading and dry running (under current) (vii) 3 pole Power contactors suitable size conforming to IS/IEC 60947-4-1 suitable for 3 phase 415Volts, 50Hz AC supply with auxillary contact 1NO + 1 NC for motor operation -06 nos or as per requirement of panel designer for FASD starter arrangement. Note: The MPCB voltage rating must match the name plate voltage of the motor. Note: (i) LT panel shall be design verified as per IS/IEC 61439 1 & 2. (ii) Contractor shall submit the following type Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI for conformance to IS/IEC 61439- 1 & 2,65 KA 1 sec in respect of LT Panel. (iii) Contractor shall submit drawing for approval prior to place order.
Supply, installation, testing and commissioning of LT panel indoor type conforming of IS : 61439 1 & 2. Totally enclosed dust and vermin proofsuitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 2.00mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc. Protection of enclosure IP 42 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. The panel shall be provided with manufacturer name plate, heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40 x 40 x 6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface. The panel shall be designed with arrangement for controlling of two motors complete and comprising of the following (Filtration Plant Pump):-
(A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic, non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar. The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables. All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three. (iv) MCB SP 6A 'C' series for control ckt protection = 03 Nos (B). INCOMER (i) MCCB 200 amp 4 pole Icu = 36 KA at 415 volts ,Ics =100% Icu with microprocessor release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos
Note: (i) LT panel shall be design verified as per IS/IEC 61439 1 & 2 (ii) Contractor shall submit the following type Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI for conformance to IS/IEC 61439- 1 & 2,65 KA 1 sec in respect of LT Panel (iii) Contractor shall submit drawing for approval prior to place order.
Material and labour for construction of valve chamber of size 1200 x 1200 x 2300 mm deep dimensions (Over all internal dimension) with PCC foundation, random rubble uncoarsed stone masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below: - Valve chamber shall be provided with the following specifications:- (i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of block masonry. (ii) Walls of valve chamber 230 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) using brick masonary setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and brick masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth. (iv) 50 mm thick coping in PCC 1:3:6 type C1 over brick masonry wall. (v) Entire plastered surfaces shall be treated with 3 coat of white wash. (vi) Chamber cover shall be of 6 mm thick MS sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. Steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supply, installation, testing and commissioning electromagnetic Flow meter for 150mm dia DI pipe with flanged ends for flow of 900LPM, with display showing flow rate in LPM/LPS/USGPM etc, zero lagging, communication facility shall be RS 485, Transmitter mounted on pipe, suitable to 230V AC power supply for outgoing at Lalgaon Pump house and Outgoing at filteration plant DI pipe complete all as specified and as directed.
Total amount of Sch 'A' PART-V (Section-II) (EXTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' -VI (Section-I) (EXTERNAL ELECTRIFICATION WORK)
Sch 'A' Part-VI (Section-II) (EXTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col 5 signifies this fact only.
Supplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 63 KVA capacity transformer step down, outdoor application, sealed type, 11000/433 volts (at no load) with nominal voltage 11KV all as per IS 1180 (Part 1): 2014, 50 c/s +/-5%, copper wound, mineral oil immersed with first filling of oil as per IS:335, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side including provision of all necessary / standard fittings all as per IS:2026 & IEC 76 Latest ammendments and conforming to EEL-3 Level of BEE. The maximum allowable losses at 75 °C for 11/0.433 kV at 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 219 watts and 791 watts respectively without any positive tolerance.The percentage impedance of transformers at 75 °C shall be 4.5%.Overload capacity of transformers shall be suitable for loading as per IS 6600.Audible sound levels shall be 51 decibels (NEMA Standards).The transformer should be designed as per tropical condition of Srinagar ,for more details refer particular specification.The transformer shall comprising of the following:
(a) One cable box on primary H.V side having cable glands suitable for 95 Sqmm 3 core XLPE 11 KV H.T cable consisting of 3 Nos porcelain H.T bushings with brass bushing rods conforming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers. The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight. The HV bushing shall be of 17.5 KV/250 A class, porcelain/polycrate with non adjustable, single gap type arcing horns. (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with GM bushing rods complete with GM nuts, and washers with cable gland suitable for reception of outgoing L.T. sheathed armoured cables having non-magnetic material gland plate with appropriate sized single compression brass glands of suitable size on LV side to terminate XLPE armoured cable. The LV bushing shall be 1.1 KV class: (4 Nos.) and HV fuse unit to be provided by OEM to protect Primary windings from overload and other faults with WTI and OTI alarm
(c) Corrugated tank: Nominal thickness of corrugation panel sheet is 1.2 mm and fins and rectangular tank thickness shall be as per Rectangular Plain Tank. The tank shall be design for a pressure of 25 kPa above atmosphere pressure, measured inside the tank for 30 minutes and vacuum of 250 mm of mercury for 30 minutes. (d) Pressure relief valve shall be of 35 kPa with dia.12.5 mm. (e) Air release plug (f) Corrugated panels to achieve the desired cooling to limit the specified temperature rise. (g) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103. (h) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. (j) Lifting lugs: 2 Nos of MS plate 8 mm thick (min) suitably reinforced by vertical supporting flat welded edgewise below the lug on the side wall. (k) Pulling lugs: 4 Nos of welded heavy duty pulling lugs of MS plate 8 mm thick (min) shall be provided to pull the transformer horizontally.
(l) Top cover fixing bolts of Stainless Steel of size ½” dia. adequately spaced not more than 80 mm pitch and 6 mm Neoprene bonded cork gaskets conforming to type III as per IS 11149/ type-c as per IS 4253 (Part-2) shall be placed between tank and cover. The Stainless Steel bolts outside tank shall have 2 flat washers & one spring washer. (m) Transformer to be painted with poly urethene/powder coated (color light gray & DA gray) paints over anti corrosive primer. The paint shall be applied by airless spray. Inside of tank shall be painted with oil resistance paint of colour shade yellow/green. (n) Rating plate with terminal markings: The information of Rating and terminal markings as per IS 1180 (Part-I) 2014, Clause No 13 shall be engraved (punched) on combined name plate. The Transformer shall be marked with the Standard Mark. Details of Guarantee Period shall also be mentioned in combined Name Plate.
(o) Two numbers of channels having following minimum size 75 x 40 x 4.8mm to be provided. The transformers shall be suitable for loading as per IS: 6600 / 1972with latest amendment if any. (p) Earthing terminals with earthing symbol having minimum size 1⅟2” X ⅟2” with lugs - 2 Nos to facilitate fixing of 32 x 6 mm GI earth strip. (q) 4 No bi-directional detachable rollers of plan solid cast steel. (r) Terminal connectors on the HV bushings and LV bushings.The bi-metallic connectors shall have to be fitted on HV/LV terminals having capacity to withstand 1.5 times of rated HV/LV current of transformer. (s) Arcing horns for HV bushings. (t) Anti-theft stainless steel fasteners with breakaway nut at Top Cover – 4 Nos. (u) LV Cable holding clamp with accessories. (v) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral.
(w) Provision of 2 Nos danger boards 200 x 250 mm size made out of 1.6 mm thick M.S. plate, vitreous enameled white, with letters. figures of voltage and conventional skull and bones in signal red colour, one at H.T side and other on L.T side. (x) Any other fittings / accessories so as to conform the whole transformer to IS 1180 (Part 1): 2014 . (y) Prismatic Oil level gauge indicating the position of oil marked with background of yellow color) as follows. Min. ( -5°C), 30°C, Max. 90°C. (z) Non return valve (NRV) -1 No (mandatory for sealed transformer with inert gas) (aa) Drain-cum-sampling metallic valve with plug and explosion vent. (ab) Silica gel container transparent type - 01 No. (ac) Foundation/plinth/staging for transformer as per CE/TD-1129/1996 Sh 1/2 and 2/2 amended upto date shall be included in the quoted rate. Note (a) Any other relevant accessories as required at site as per IS to be provided. (b) Contractor should submit general arrangement drawing pertaining to transformer, drawing of combined name plate and technical details sheet to GE before purchase.
Supplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 100 KVA capacity transformer step down, outdoor application, sealed type, 11000/433 volts (at no load) with nominal voltage 11KV all as per IS 1180 (Part 1): 2014, 50 c/s +/-5%, copper wound, mineral oil immersed with first filling of oil as per IS:335, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side, including provision of all necessary / standard fittings all as per IS:2026 & IEC 76 Latest ammendments and conforming to EEL -3 Level of BEE. The maximum allowable losses at 75 °C for 11/0.433 kV at 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 317 watts and 1130 watts respectively without any positive tolerance. The percentage impedance of transformers at 75 °C shall be 4.5%. Overload capacity of transformers shall be suitable for loading as per IS 6600. Audible sound levels shall be 55 decibels (NEMA Standards). The transformer should be designed as per tropical condition of Srinagar, for more details refer particular specification.The transformer shall comprising of the following:
(a) One cable box on primary H.V side having cable glands suitable for 95 Sqmm 3 core XLPE 11 KV H.T cable consisting of 3 Nos porcelain H.T bushings with brass bushing rods confirming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers.The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight.The HV bushing shall be of 17.5 KV/250 A class, porcelain/ polycrate with non adjustable, single gap type arcing horns. (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with brass bushing rods 20mm dia complete with brass nuts, and washers with cable gland suitable for reception of outgoing L.T. sheathed armoured cables having non-magnetic material gland plate with appropriate sized single compression brass glands of suitable size on LV side to terminate XLPE armoured cable. The LV bushing shall be1.1 KV class: (4 Nos.) and HV fuse unit to be provided by OEM to protect Primary windings from overload and other faults with WTI and OTI alarm. (c ) Corrugated tank: Nominal thickness of corrugation panel sheet is 1.2 mm and fins and ractangular tank thickness shall be as per Rectangular Plain Tank. The tank shall be design for a pressure of 25 kPa above atmosphere pressure, measured inside the tank for 30 minutes and vacuum of 500 mm of mercury for 30 minutes. (d) Pressure relief valve shall be of 35 kPa with dia.12.5 mm. (e )Air release plug. (f) Corrugated panels to achieve the desired cooling to limit the specified temperature rise.
(g) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103. (h) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device. (j) Lifting lugs: 4 Nos of MS plate 8 mm thick (min) suitably reinforced by vertical supporting flat welded edgewise below the lug on the side wall. (k) Pulling lugs: 4 Nos of welded heavy duty pulling lugs of MS plate 8 mm thick (min) shall be provided to pull the transformer horizontally. (l) Top cover fixing bolts of Stainless Steel of size ½” dia adequately spaced not more than 80 mm pitch and 6 mm Neoprene bonded cork gaskets conforming to type III as per IS 11149/ type-c as per IS 4253 (Part-2) shall be placed between tank and cover.The Stainless Steel bolts outside tank shall have 2 flat washers & one spring washer. (m) Transformer to be painted with poly urethene/powder caoted (color light gray & DA gray) paints over anti corrosive primer. The paint shall be applied by airless spray.Inside of tank shall be painted with oil resistance paint of colour shade yellow/green. (n) Rating plate with terminal markings: The information of Rating and terminal markings as per IS 1180 (Part-I) 2014, Clause No 13 shall be engraved (punched) on combined name plate. The Transformer shall be marked with the Standard Mark. Details of Guarantee Period shall also be mentioned in combined Name Plate. (o) Two numbers of channels having following minimum size 100 x 50 x 4.80 mm to be provided. The transformers shall be suitable for loading as per IS: 6600 / 1972 with latest amendment if any.
(p) Earthing terminals with earthing symbol having minimum size 1⅟2” X ⅟2” with lugs - 2 Nos to facilitate fixing of 32 x 6 mm GI earth strip. (q) 4 No. bi-directional detachable rollers of plan solid cast steel. (r) Terminal connectors on the HV bushings and LV bushings. The bi-metallic connectors shall have to be fitted on HV/LV terminals having capacity to withstand 1.5 times of rated HV/LV current of transformer. (s) Arcing horns for HV bushings. (t) Anti-theft stainless steel fasteners with breakaway nut at Top Cover – 4 Nos. (u) LV Cable holding clamp with accessories. (v) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral. (w) Provision of 2 Nos danger boards 200 x 250 mm size made out of 1.6 mm thick M.S. plate, vitreous enameled white, with letters. figures of voltage and conventional skull and bones in signal red colour, one at H.T side and other on L.T side. (x) Any other fittings / accessories so as to conform the whole transformer to IS 1180 (Part 1): 2014. (y) Prismatic Oil level gauge indicating the position of oil marked with back ground of yellow color) as follows. Min. ( -5°C), 30°C, Max.90°C. (z) Non return valve (NRV) -1 No (mandatory for sealed transformer with inert gas). (aa) Drain-cum-sampling metallic valve with plug and explosion vent. (ab) Silica gel container transparent type - 01 No. (ac) Foundation/plinth/staging for transformer as per CE/TD-1129/1996 Sh 1/2 and 2/2 amended upto date shall be included in the quoted rate. Note (a) Any other relevant accessories as required at site as per IS to be provided. (b) Contractor should submit general arrangement drawing pertaining to transformer, drawing of combined name plate and technical details sheet to GE before purchase.
Supply and fixing Voltage stabilizer servo controlled suitable for automatic operation, three phase, indoor floor mounted, naturally oil cooled & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 V with accuracy ± 1% and speed of correction not less than 6 volts per second for single phase and 13 volts per second for phase to phase of capacity 75 KVA conforming to IS. 9815 (Part-I) /1994 (Reaffirmed 2019) with latest amendments, Painted using 7 tank process system powder coated (color light gray & DA gray) paints over anti corrosive primer, with first filling of Transformer grade Oil confirming to IS: 335/IEC 296 and with necessary by pass arrangement by means of suitable capacity change over switch, fully automatic operation mode. All the three phases will be corrected independently, Suitable for Balanced or 100% Unbalanced Supply load. The stabilizer should be designed as per tropical condition of Srinagar for any detail service condition refer particular specification.The stabilizer should have MCCB for OL & SC protection, Input phase reversal, Input single phasing Protection and phase sequence changing protection. LED Indications for each phase input, each phase output, short circuit, and over load complete all as specified with following parameters and accessories as under:
(u) Protection: Single Phasing Prevention, Output Electronic Overload Protection, Phase reversal protection, Output Low and high Voltage Protection and Surge suppressor Protections, (v) Rating Plate, (w) Standard BIS Mark. In addition to above the stabilizer should be provided with Two Nos. Earthing terminals, Cable end boxes for incoming and outgoing side for terminating cables, Oil level indicator, filling & drain valve, lifting lugs, provision for Auto/Manual control from the front panel. complete all as specified and as directed by Engr-in-charge. Note: (a) Any other relevant accessories as required at site as per IS to be provided. (b)Contractor should submit general arrangement drawing, drawing of combined name plate and technical details sheet to GE before purchase.
Supply, installation, testing and commissioning of indoor type micro processor based automatic power factor correction (APFC) system 50 KVAR (design should be as per tropical condition of Srinagar), having auto switching system for each stage in the form of electro magnetic switching system used for energizing each capacitor stage should have current carrying capacity not less than 1.5 times the charging current of respective stage. Each switching should have a 22.5mm dia, 230 volts, AC, ON/OFF indication of LED type. The system should have option to run it on fully automatic and manual mode. In manual mode the system may be operated by the use of 22.5 mm dia actuators provided in the front fascia. Self adhesive computer cut vinyl letters shall be used for switching stage indentification. The degree of protection shall be IP-42. The outer shell of panel shall be made of 2.00mm thick CRCA sheet and MS angle section 50 x 50 x 6mm frame factory fabricated with front and back openable, single door system lockable /openable by keys from both sides, louvers & air vent gasket for natuiral flow of air, "U" type gasket to be used for dust and vermin proof, The bottom of outer shell contains a detachable plate having provision for cable entry with adequate size detachable glands. The outer shell shall be powder coated with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. Provision of threaded earthing stud at bottom and lifting lugs of suitable size at top to lift APFC Panel. A detachable pre drilled gland plate of thickness 3.15mm powder coated should be used at the bottom. Inner shell shall be made of 1.6mm thick CRCA sheet suitably compartmentalized for front and back openable single door system lockable /openable by keys from both sides, louvers & air vent gasket for natuiral flow of air, "U" type gasket to be used for dust and vermin proof to accomodate incomer / outgoing MCCBs/MCBs and TPN electrolytic grade aluminium bus bar. The APFC Panel shall be comprising of the following :-
(a) Busbar: TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic, non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar. The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm multi stranded copper conductor and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. (b) Exhaust Fan: 2No suitable size & capacity but not less than 6 inches exhaust fan. shall be as required for heat dissipation to maintain temperature inside the panel within 50°C. (c) APFC Relay:- With inbuilt solid state automatic power factor correction arrangement having microprocessor(Intelligent) based control circuit & capacitor duty contractor power switching Stage having a required capacity of 50 KVAR having capacitor bank in steps of 1 x 3 KVAR, 1 x 5 KVAR, 1 x 10 KVAR, 2 X 15 KVAR and 1 x 2 KVAR Direct connected with busbar through 32 AMP TPN MCB. Note: Suitable stages and configuration of capacitor should be designed from panel manufacturer get it approved from GE/AGE by the contractor before placement of order. (d) MCCB: Incoming should be MCCB 100 Amp 4 pole, 25 KA, lcs = 100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos. Outgoing: Suitable size and qty of MCB/MCCB along with 2NO+2NC contactor of adequate capacity shall be provided as per capacitor design.
(e) Micro processor: Microprocessor incorporated will be of size 144 x 144mm flush mounted on site programmable capable for detecting wrong current transformer connections with folloowing specification: - (i) Programmable: at site (ii) Protection class: IP 42 front and IP 31 rear (iii) Working Temperature: (-)10°C to (+) 50°C (iv) Over voltage trip point :± 15 % (v) Alarm contact: one (vi) Harmonics O/L: Available (vii) Low current release: Less than 50mA (viii) Voltage release: 35 milii seconds (ix) Switching sequence: Self adjusting (x) PF adjusting range: 0.8 lag - 0.95 lead by digital settling keys. (xi) C/K adjustment: Auto calculation of C/K value (xii) Voltage burden: 5VA (xiii) Current burden: 0.5 VA (xiv) Stage: Minimum 10 to Max 14 (xv) Frequecncy : 50 Hz (xvi) Voltage inputs :415 ± 15%, Current inputs: 5A (xvii) Contact Function: Alarm
(h) Base Channel: Provision of channel of size 75x 40mm (ISMC 75) base channel at bottom. (j) Rating Plate: Shall be provided on the capacitor indicating the following as per IS 13340: (i). Reference IS, (ii). Name of manufacturer, (iii). Type of capacitor iv. Sl. No & year of manufacture, (v). Rated output in kVAr, (vi). Rated voltage in volts, (vii). Rated frequency, (viii). Temperature category, (ix). Discharge device, (x). Ref to self healing design, (xi). Type of dielectric, (xii). Connection symbol. Note: (i) Routine and Acceptance test certificates for the test conducted within a period not more than 5 years at CPRI / ERDA / any NABL accredited lab as per their relevant IS / IEC shall be submitted by the contractor (ii) Contractor shall submit GA drawing for approval prior to placement of order.
Supply, installation, testing and commissioning of indoor type micro processor based automatic power factor correction(APFC) system 30 KVAR (design should be as per tropical condition of Srinagar), having auto switching system for each stage in the form of electro magnetic switching system used for energizing each capacitor stage should have current carrying capacity not less than 1.5 times the charging current of respective stage. Each switching should have a 22.5mm dia, 230 volts, AC, ON/OFF indication of LED type. The system should have option to run it on fully automatic and manual mode.In manual mode the system may be operated by the use of 22.5 mm dia actuators provided in the front fascia. Self adhesive computer cut vinyl letters shall be used for switching stage indentification. The degree of protection shall be IP-42. The outer shell of panel shall be made of 2.00mm thick CRCA sheet and MS angle section 50 x 50 x 6mm frame factory fabricated with front and back openable, single door system lockable/openable by keys from both sides, louvers & air vent gasket for natuiral flow of air, "U" type gasket to be used for dust and vermin proof. The bottom of outer shell contains a detachable plate having provision for cable entry with adequate size detachable glands. The outer shell shall be powder coated with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. Provision of threaded earthing stud at bottom and lifting lugs of suitable size at top to lift APFC Panel. A detachable pre drilled gland plate of thickness 3.15mm powder coated should be used at the bottom. Inner shell shall be made of 1.6mm thick CRCA sheet suitably compartmentalized for front and back openable single door system lockable/openable by keys from both sides, louvers & air vent gasket for natuiral flow of air, "U" type gasket to be used for dust and vermin proof to accomodate incomer / outgoing MCCBs/MCBs and TPN electrolytic grade aluminium bus bar. The APFC Panel shall be comprising of the following :-
(a) Busbar: TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic, non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and inter connected busbar. The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm multi stranded copper conductor and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. (b) Exhaust Fan: 2No suitable size & capacity but not less than 6 inches exhaust fan shall be as required for heat dissipation to maintain temperature inside the panel within 50°C. (c) APFC Relay:- With inbuilt solid state automatic power factor correction arrangement having microprocessor (Intelligent) based control circuit & capacitor duty contractor power switching Stage having a required capacity of 30 KVAR having capacitor bank in steps of: - 1 x 3 KVAR, 3 x 5 KVAR, 1 x 10 KVAR and 1 x 2 KVAR Direct connected with busbar through 32 AMP TPN MCB. Note: Suitable stages and configuration of capacitor should be designed from panel manufacturer get it approved from GE/AGE by the contractor before placement of order.
(d) MCCB: Incoming should be MCCB 63 Amp 4 pole, 25 KA, lcs = 100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos. Outgoing : Suitable size and qty of MCB/MCCB along with 2NO+2NC contrcator of adequate capacity shall be provided as per capacitor design. (e) Micro processor: Microprocessor incorporated will be of size 144 x144 mm flush mounted on site programmable capable for detecting wrong current transformer connections with folloowing specification: -
(i) Programmable: at site (ii) Protection class: IP 42 front and IP 31 rear (iii) Working Temperature: (-)10°C to (+) 50°C (iv) Over voltage trip point :± 15 % (v) Alarm contact: one (vi) Harmonics O/L: Available (vii) Low current release: Less than 50mA (viii) Voltage release: 35 milii seconds (ix) Switching sequence: Self adjusting (x) PF adjusting range: 0.8 lag - 0.95 lead by digital settling keys. (xi) C/K adjustment: Auto calculation of C/K value (xii) Voltage burden: 5VA (xiii) Current burden: 0.5 VA (xiv) Stage: Minimum 10 to Max 14 (xv) Frequecncy: 50 Hz (xvi) Voltage inputs: 415 ± 15%, Current inputs: 5A (xvii) Contact Function: Alarm (f) Capacitor: The capacitor shall be housed in self extinguishing insulating material operated on 3 ph 415 volts AC, 50 Hz system. The dielectric should be mixed dilectric type with built in over pressure safety device. Minimum static life expentancy is more than 400000 hrs and switched life 135000 switching per year. The capacitor will carry following technical specification: (i) Di electric construction: Mixed dielectric (ii) Over Current withstand capacity upto: 5.0 x Ir (iii) Peak Inrush Current Withstand Capacity upto: 550 times (iv) Output capcitance tolerance: 0% to 10% (iv) Dieletric losses: 0.2 watt/KVAR (v) Degree of protection: IP -30 (vi) Refrence Standard: IEC831-1 &2, IS 2834, IS 13340, IS 13341 (vii) Temperature: 50°C Max
Supply, install, testing, commissioning of 'Silent type' diesel generating set alongwith having alternator rating of 100kVA/80 kW, 415Volts at 1500RPM, 0.8 lagging power factor at 415 volts suitable for 50 hz 3 phase system and for 0.85 load factor, CPCB-II complied, acoustic enclosure, relay panel for automatic starting on main failure (AMF), anti vibration mountings, control panel and foundation. The DG set should be robust in construction factory tested and assembled to ensure perfect alignment of Engine and Alternator on a common base frame. The DG set power rating indicated above is inclusive of altitude correction factor however the DG Set shall be designed and suitable to operate as per tropical condition of Srinagar after taking into account necessary derating factor in the capacity of engine for tropical conditions prevalent at Srinagar and for more details on service condition refer particualr specification.The DG set shall be comprising of following item as under:-
(a) Diesel Engine: The diesel engine shall be of four stroke cycle multi-cylinder,direct injection water cooled, turbo charged with after cooler, Air to air aftercooling and optimised turbocharger for increased altitude capabilities developing required BHP @ 1500 rpm under NTP condition of BS 5514/ISO 3046 with an over load capacity of 110% for one hour in any specified 12 hrs of continuous operation, suitable for generating set application on AMF mode. The engine shall confirm to IS:10000/BS:649/BS 5514/ISO 3046The engine shall have the following accessories: - (i) Cooling fan and radiator. (ii) DM water cooling systems with pre-mix anti-corrosive additive (iii) Turbocharger. (iv) Fly wheel with fly wheel housing. (v) Electrical engine starter motor (disengagement after start-up) with Batteries. (vi) Battery charging systems. (vii) Stainless steel exhaust flexible elbow. (viii) Thermal sealing of exhaust pipe and aluminium cladding for complete exhaust pipe and silencer. (ix) Required filters for fuel, lube oil, air etc. (x) Sets of flexible hoses as required. (xi) Suitable rubber coupling to Alternator with guard. (xii) Suitable Engine controller for protection of the engine. (xiii) Coolant heater and crankcase heater. (xiv) Oil drain Pump. (xv) Heavy duty air cleaner.
(b) Engine protections: (i) High coolant temperature warning & trip (ii)Low lubricating oil pressure warning & trip (iii) Low coolant level warning & trip(iv) Fail to crank trip (v) Over crank trip (vi) High and Low speed trip (vii) Low or High battery voltage alarms.(viii) Clogged filter warning and Lack of fuel (ix) High Canopy Temperature (x) Set fail to start protection after failure of the set to start after successful three consecutive start attempts.
(c) Starting system: The engine starting shall be by means of totally enclosed axial type electric starter suitable for 12volts/24 volts DC starting system comprising of starter motor, voltage regulator and arrangement for initial excitation complete with suitable number of batteries(25 plates, 180AH Sealed Maintenance Free (SMF) Lead-Acid type) as required as per specifications. The battery shall be supplied with a suitable floor mounted MS stand treated with seven tank treatment, two coats of red oxide /primer & acid resistant paint.with wooden base, adaptor box etc . with copper conductor battery leads of required length and socket/clamps
(d) Alternator: 100 kVA 3 phase 0.8 PF 415V, 4 wire 1500 rpm self-excited and self regulated through AVR confirming to IS :4722/BS 2613 suitbale for tropical condition with brush less exciter, housed in screen protected drip proof enclosure. The alternator shall be confirming to IS 13364 Part-2 & IS 15999 Part-1/ IEC 60034 Part-1 capable of delivering rated output at rated power factor with, (i) Terminal voltage differing from the rated value by not more than +/- 5%. (ii) Frequency differing from the rated value by not more than +/-0.5%. (iii) Short circuit capacity of 300% for 10 seconds. (iv) Over load capacity of 110% for one hour. The insulation class of the Alternator shall be class F/ H. The temperature rise shall be limited to class B and Ingresses enclosure protection shall IP23 or better. The alternator shall be fitted with suitable Nos. Resistance Temperature Device (RTD) & Bearing Temperature Device (BTD) along with space heaters. (e) Alternator Protection: Alternator should have following protections: - (i) Over and Under voltage (ii) Under and Over frequency warning and trip (iii) Loss of excitation (iv) Over current and Earth Fault and Short Circuit Protection (v) Unbalanced loads (vi) Restricted Earth Fault Protection. (vii) Differential protection. (viii) Diode Failure.
(g) Acoustic enclousure: The acoustic enclosure should be supplied along with DG set from the manufacturer outlet itself as per CPCB norm.Acoustic enclosure shall be of powder coated and fabricated out of 2mm thick CRCA MS sheet. The canopy shall have four hinged doors, one door with glass window to view proper parameters on the control panel. The canopy and doors shall have inside lining of fire retardant foam/glasswool as acoustic materials. The base frame shall be fabricated in ISMC channel or in sheet metal, with lifting hooks for convenient lifting of complete set i.e. along with canopy, engine and alternator. The sound level shall have less
than 75 db (A) at a distance of 1 meter.High quality noise absorbant and fire-retardant grade acoustic Insulation material (P.U. Foam) complying to IS 8183. The allowable temperature raise inside the canopy is 5 to 7 deg. Centigrade. The Measurement of noise should be as per ISO 3744/ ISO 8528 (Part 10) standard.The canopy has the provision of emergency push button, external to the canopy
(h) Governor :The governor shall be of electronic type suitable for monitoring constant engine speed within the specified limits for auto parallel and auto load sharing operation.
(j) Exhaust: The exhaust piping system shall be supplied with a hospital grade silencer and catalytic converter suitably optimized to meet stringent noise emission standards laid down by MoEF / CPCB.The exhaust piping and the silencer shall be wrapped with rock wool and/or calcium silicate. The outside shall be neatly wrapped with aluminum cladding. The exhaust line shall be extended beyond the height of the utility building roof as required by pollution control norms.Suitable supporting structure for installation shalll be provided.
(k) Hot air exhaust (Radiator cooling): GI duct shall be provided for hot air exhaust from DG set up to designated place of duct outlet. The duct shall be made of 14 Gauge thick Class-8, Galvanized Iron (GI) Sheet.Galvanised Iron (GI) duct shall be provided for venting hot exhaust air out of the DG room, from radiator hot air outlet point of the DG Acoustic enclosure through nearest brick wall.
(l) Fuel Tank: Inbuilt/internal bottom mounted (with-in DG set or with-in base frame) diesel tank of suitable capacity with mounting brackets, complete with fuel inlet, out let, air vent, drain plug, level indicator, inter connection pipes from tank to diesel generator as required. Suitable barrier shall be provided between Diesel tank and the Engine. Fuel tank shall be fabricated as per tropical condition of Srinagar with 210 Litres approx. capacity or designed capacity shall be suitable for 8 hrs continous operation.
(m) AMF Control Panel: The control panel shall be designed for Automatic ON Mains Failure Operationof the Generator sets. The Panel will be totally enclosed, Dust tight, vermin proof,floor mounted, free standing, cubical compartmentalized type with hinged doors, fabricated from 14 SWG CRCA Steel metal having separatecompartments . The Panel will be epoxy painted powder coated with light grey shade, After Seven Tank treatment, and the Panel / compartment will be fitted with the following instrument and pre-wired with colour coded flexible copper cable with ferule Numbers for easy identification & maintenance. The panel shall be complete with interconnections, insulators, two nos. of earthing lugs and with suitable rating of MCCB at both the end & shall incorporate the followings
Note: (i) AMF Panel shall be installed outside the acoustic enclousre (ii) LT Cable of suitable rating from DG set Alternator output to Automatic main failure panel (AMF panel) should be provided by the contractor. (iii) Cost of DG set foundation deemed to be included in cost of item. (iv) Contractor should submit necessary drawing to GE/Engineer-in-Charge before placing the order.
Supply ,laying or fixing or passing through pipe PVC insulated industrial grade copper conductor (sheathed) Flexible round cable, fire retardant,1100 Volts grade of size 25Sqmm nominal cross sectional area single core conforming to IS 694 specification complete all as specified and as directed.
BLANK
Supply, installation, testing and commissioning of LT panel outdoor type confirming of IS : 61439 1 & 2. Totally enclosed dust and vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc.Protection of enclosure IP 56 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface complete and comprising of the following:
(A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied, ferruled for proper identification and crimped with adequate size of lugs. (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete (iii) Indication lamps LED type (RYB) - 02 sets of three
B. INCOMER (i) MCCB 160 Amp 4 pole Icu = 36 KA at 415 volts conforming to IS:13947(Part-3) 1993, lcs = 100% lcu, with thermal magnetic release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos (ii) ON Load change over switch without enclosure 160 amps 4 pole TPN front handle operated confirming to IS:13947(Part-3) 1993 -01 nos
C. OUTGOING (i) MCCB 125 Amp 4 pole conforming to IS: 13947(Part-3) 1993, , Icu = 16 KA at 415 Volts,lcs = 100% lcu, with thermal magnetic release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos (ii) (i) MCCB 40 Amp 4 pole confirming to IS:13947 (Part-3) 1993, 16 KA, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 03 nos
D.Platform for feeder pillar/LT Panel shall be of suitable size as directed 200mm height above ground level, the foundation shall be using PCC 1:2:4 type B1,15cm thick, brick (sub class B) work in CM 1:6, rendering in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel.
Note: (i) LT panel shall be design verified as per IS/IEC 61439 1 & 2 (ii) Contractor shall submit the following type Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI for conformance to IS/IEC 61439- 1 & 2,65 KA 1 sec in respect of LT Panel (iii) Contractor shall submit drawing for approval prior to place order.
Supply, installation, testing and commissioning of LT panel outdoor type confirming of IS: 61439 1 & 2. Totally enclosed dust and vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc.Protection of enclosure IP 56 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface complete and comprising of the following:
(A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs. (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete (iii) Indication lamps LED type (RYB) = 02 Sets of three.
B. INCOMER (i) MCCB 160 Amp 4 pole conforming to IS:13947(Part-3) 1993, Icu = 25 KA at 415 Volts, lcs = 100% lcu, with thermal magnetic release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos (ii) ON Load change over switch without enclosure 160 amps 4 pole TPN front handle operated confirming to IS:13947(Part-3) 1993 -01 nos
C. OUTGOING (i) MCCB 100 Amp 4 pole conforming to IS:13947(Part-3) 1993, Icu = 16 KA at 415 Volts, lcs = 100% lcu, with thermal magnetic release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos (ii) (i) MCCB 40 Amp 4 pole conforming to IS:13947(Part-3) 1993, Icu = 16 KA at 415 Volts, lcs = 100% lcu, with thermal magnetic release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos
D. Platform for feeder pillar/LT Panel shall be of suitable size as directed 200mm height above ground level, the foundation shall be using PCC 1:2:4 type B1,15cm thick, brick (sub class B) work in CM 1:6, rendering in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel.
Note: (i) LT panel shall be design verified as per IS/IEC 61439 1 & 2 (ii) Contractor shall submit the following type Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI for conformance to IS/IEC 61439- 1 & 2,65 KA 1 sec in respect of LT Panel (iii) Contractor shall submit drawing for approval prior to place order.
Supply and fixing LED fllood Light fitting 120 watt, for opearting voltage between 140V to 300V system efficiency not less than 110 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver with over voltage protection,surge protection and other safety test as per IS 15885 Part-2/Sec 13, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing(heat sink) with UV stabilized optics, polycarbonate LENS for symmetrical light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and as directed by Engineer-in-charge.
S & F Voltage stabilizer servo controlled suitable for automatic operation, three phase, indoor floor mounted ,naturally oil cooled & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 V with accuracy ± 1% and speed of correction not less than 6 volts per second for single phase and 13 volts per second for phase to phase of capacity 100 KVA conforming to IS. 9815 (Part-I) /1994 (Reaffirmed 2019) with latest amendments, Painted using 7 tank process system powder coated (color light gray & DA gray) paints over anti corrosive primer, with first filling of Transformer grade Oil confirming to IS: 335/IEC 296 and with necessary by pass arrangement by means of suitable capacity change over switch, fully automatic operation mode. All the three phases will be corrected independently, Suitable for Balanced or 100% Unbalanced Supply Load. The stabilizer should be designed as per tropical condition of Srinagar for any detail service condition refer particular specification. The stabilizer should have MCCB for OL & SC protection, Input phase reversal, Input single phasing Protection and phase sequence changing protection. LED Indications for each phase input, each phase output, short circuit and over load complete all as specified with following parameters and accessories as under:
(p) Heavy duty AC synchronous motor for individual phase correction. (q) Solid-state electronic plug in PCB circuits for control. (r) Copper wound in CRGO laminations buck/boost transformer for each phase. (s) Control circuits for individual phase control. (t) Four Nos bi-directional detachable rollers of plan solid cast steel. (u) Protection: Single Phasing Prevention, Output Electronic Overload Protection, Phase reversal protection, Output Low and high Voltage Protection and Surge suppressor Protections (v) Rating Plate (w) Standard BIS Mark. In addition to above the stabilizer should be provided with Two Nos. Earthing terminals, Cable end boxes for incoming and outgoing side for terminating cables, Oil level indicator, filling & drain valve, lifting lugs, provision for Auto/Manual control from the front panel complete all as specified and as directed by Engineer-in-charge. Note (a) Any other relevant accessories as required at site as per IS to be provided.(b)Contractor should submit general arrangement drawing, drawing of combined name plate and technical details sheet to GE before purchase.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 32 x 6 mm galvanised earth strip by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
(e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note: (1) The resistance should be less than 5 ohms after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (2) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing
Total amount of Sch 'A' PART-V (Section-II) (EXTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' Part-VII (SITE CLEARANCE, EXCAVATION AND EARTH WORK)
NOTE: Amount against schedule of credit for retrieved materials mentioned under relevant part of Sch of Credit of tender document in PDF form (if applicable) will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during award of contract.
M/S GHULAM AHMAD WANI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .