Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L1 | Accepted-AOC AOC | |
| 2 | L2₹16.4 L+₹63,840 (4.05%)Rejected-AOC | L2 | Rejected-AOC rEJECTED | |
| 3 | L3₹17.0 L+₹1.2 L (7.69%)Rejected-AOC RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC REJECTED |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Jul 2024, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon
CA NO. GE AF NO.1/GUR-40/2024-25 REPAIR / REPLACEMENT AND UPKEEP OF SOLAR PANELS GI TUBING AND REPAIR TO ELECTRIC BACK UP AT AF STN GURGAON UNDER GE (AF) GURGAON NO.1.
2024_MES_658354_1
GE (AF) Gurgaon No 1/GUR-40/2024-25
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹60,000
Yes
6 Sept 2024
8 Jun 2024
12 Jul 2024
8 Jun 2024
10 Jul 2024
26 Jun 2024
Amount
Taking down Solar water heater for repair /maintenance including servicing capacity upto 300 LPD installed at single/double/triple story bldgs for carrying out minor leakage, cleaning of flat plate collector glass & cleaning of tank and make up tank including dismantling inlet and out let connections and re-fixing the same after cleaning for proper functioning to maintain proper water temperature, all as specified and directed by Engr-in-Charge.
S&F in replacement toughned glass suitable for solar plant of capacity 300 LPD complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement flange of add on collector (pack of 10) suitable for solar plant of capacity 300 LPD complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement evacuated glass tube (58mm) suitable for solar plant of capacity 300 LPD complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement electrical backup contoller 3.0 KW suitable for solar plant of capacity 300 LPD, complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement silicon ring (pack of 20) suitable for solar plant of capacity 300 LPD complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement tube holder (pack of 20) suitable for solar plant of capacity 300 LPD complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement gaskets (pack of 20) suitable for solar plant of capacity 300 LPD, complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement dead plug of collector (pack of 10) suitable for solar plant of capacity 300 LPD, complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement washer of collector (pack of 10) suitable for solar plant of capacity 300 LPD complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement anti rust ring (pack of 20) suitable for solar plant of capacity 300 LPD, complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
S&F in replacement storage tank SS grade 304, 316 PUF insulated, suitable for solar plant of capacity 300 LPD, complete all as specified and directed by Engr-in-Charge. Make :- As per existing make installed at site or equivalent out of make specified in tender.
M&L of collector glass/tubing of solar heating system by using colin & water complete all as specified and directed by Engr-in-Charge.
Descaling of Solar Water heating tank and pipe lines by re-circulating descaling solution with pumps complete all as specified and directed by Engr-in-Charge.
S&F in replacement Heating Element of capacity 3KW,AC, 230/415 Volt, complete all as specified and directed by Engr-in-Charge. Make : Damfos/ Theeta/ Usha/as per make installed at site
S&F in replacement Thermostate suitable for 0 -100 degree, AC, 230V, single phase, 50 Hz complete all as specified and directed by Engr-in-Charge. Make-Damfos/ Theeta/ Usha/as per make installed at site.
Supply and fixing in repairs compressed glass wool 50 mm thick between solar energy collector panel copper tubes frame and aluminium body of panel including securing it on panel by means of necessary adhesives all as directed all as specified and directed by Eng- in -charge.
Supply and fixing in repairs aluminium sheet cover 1mm thick to protect glass wool on solar energy collector panel, fixing with frame of solar panel by means of screws all as directed and recommended by manufacturer.
M&L in replacement PVC tank double layered of capacity 300 ltrs as make up tank as per ISI mark incl connecting existing inlet and outlet pipe connection after complete all as specified and directed by engr in charge.
M&L, for providing rubber foam heavy duty insulation tube over the existing GI tubing of any length at any location in replacement of worn out insulation all as required at site, complete all as specified and directed by Engr-in-Charge.
M&L for GI tubing medium grade, galvanised with all fittings , laid in trenches /on wall/floor etc . ISI mark 25 mm dia bore complete all as specified and directed by Engr-in-Charge.
M&L for GI tubing medium grade, galvanised with all fittings , laid in trenches /on wall/floor etc . ISI mark 20 mm dia bore complete all as specified and directed by Engr-in-Charge.
M&L for GI tubing medium grade, galvanised with all fittings , laid in trenches /on wall/floor etc . ISI mark 15 mm dia bore complete all as specified and directed by Engr-in-Charge.
Supply & Fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 15 mm bore pipes complete all as specified and directed by Engr-in-Charge.
Supply & Fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipes complete all as specified and directed by Engr-in-Charge.
M&L for replacement of rubber hose pipe 15mm dia between hot water tank & collector with fitting complete all as specified and directed by Engr-in-Charge
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50m deep for laying of water pipe lines/taking out pipe lines and getting out in soft/lose of soil including forming bottom surface to required level and slope all as specified and directed.
Returing ,fiiling including spreading ,leveling ,watering and well ramming in layers not exe. 2.5 cm soil all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and doepositing where directed at a level not exceeding 1.5 m above the strarting point.
M&L for MS framed bracket of angle iron / Tees /GI pipe cut and bend to shape ,drilled and screw , including bending & welding angle as necessary GI pipe angle iron frame /stand to make structural stand complete all as specified and directed by engr-in-charge
M&L for painting to angle iron /GI pipe frame / stand after cleaning properly removing dirt ,dust ,rubbing with sand papper and applying two coat of synthetic enamell paint over a coat of red oxide primer ,incl marking of MES no the solar water heater complete all as directed by engr -in- charge
M&L for cutting existing GI steel tubing of size upto 80 mm dia and screwing existing steel tubing for alteration or addition ( or lengthening screw on pipe to form connector) of 20 mm bore complete all as directed by engr -in- charge
M&L in replacement for Sub Main wiring with two runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp.complete all as specified and directed by Engineer-in-Charge.
Maintenance & Cleaning of Solar Power Plant 7.5 kWp applying greasing and tightening of terminals and cleaning of all solar plates and maintenance of Solar inverter system monthly once and all as specified and as directed by Engineer-in-charge.
Maintenance & Cleaning of Solar Power Plant 25 kW, applying greasing and tightening of terminals and cleaning of all solar plates and maintenance of Solar inverter system monthly once and all as specified and as directed by Engineer-in-charge..
Notes:- Notes:- The amount of Rs 40880/- against Schedule of Credit shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (g) Any disturbed surface during execution of work shall be made good as existing. Nothing extra shall be paid in this respect. The quoted rate are deemed to be included the same cost.
OM ASSOCIATES (BID ID -3048324)
M/S PARKASH ENTERPRISES (BID ID -3047942)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .