| 1 | L1₹42.5 LAccepted-AOC PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹42.9 L+₹28,282 (0.66%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹43.0 L+₹29,540.80 (0.69%)Rejected-Finance A 46 ARYA NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹47.8 L+₹5.1 L (12.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹47.2 L
EMD Value
₹94,500
Closing Date
1 Jun 2024, 6:00 pmClosed
GE Alwar
Alwar
PROVN OF 02 X BOREWELL WITH SUBMERSIBLE PUMP AND SPL REPAIR OF CONVERSION OF LT OH TO LT UG CABLE AND CONNECTED WORK AT GVTC AT ITARANA CANTT ALWAR
2024_MES_652100_1
8213/E8
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Works
180 days
GE Alwar
As per NIT
3 documents required · 3 mandatory
₹500
GE ALwar
₹94,500
Yes
5 Sept 2024
3 May 2024
3 Jun 2024
3 May 2024
1 Jun 2024
18 May 2024
3 May 2024 - 17 May 2024
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep for laying of pipe and getting out in soft/loose soil incl cutting of roads where reqd, laying of cable, foundation of poles, stays assembley etc complete all as specified & directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified & directed.
Removal of excavated soil to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 mtr above the starting point etc complete all as specified & directed.
M&L brick cover of burnt clay fly ash bldg brick old size brick 'B' class with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjecent bricks bricks not exc 10 mm over UG cable for protection etc complete all as specified & directed.
M&L sand cushioning to PVC UG cable with screened and washed sand punning to provide a required cover etc complete all as specified & directed.
Trial bore holes 150mm dia in any type of strata of bore well if the same is found fit otherwise to fill up the same hole as directed including submitting the strata details both graphically recorded as well as strata results. Note :- The rates quoted shall deemed to include to get survey done for availability/facibility of water as recommended by CGWD before execution of work.
Widening of trial bore by drilling with rotary system upto 450mm dia bore at any depth including all works pertaining to boring etc complete in all respects and all as specified, in alluvium soil / soft strata.
All as per item No 7.00 above but of 200mm dia in hard rock and drilling with DTH system till meeting water strata all as directed.
All as per item No 7.00 above but of 200mm dia in hard rock and drilling with ODEX system till meeting water strata all as directed.
Supply and assembling jointing lowering and fixing in position of ERW MS casing pipe 200mm bore of 5.4mm thickness (minimum) upto required depth below ground level in all strata (including cutting welding as required, painting etc complete ISI marked including MS well cap and also as specified and directed. Make - TATA/Swstik/Jindal/Prakash
Supply, assembling, including jointing lowering and fixing in position ERW MS slotted pipe 200mm bore of 5.4mm thickness ( minimum ) having slots of 1.59 mm wide, 75 mm long assembled and lowered as per location chart approved by the GE including cutting welding as required and painting etc complete all as specified. Note for item Nos 10.00 &11.00 :- Rate quoted by Contractor shall deemed to include for S&F well capacity 200mm bore on top of pipe with locking arrengement till the borewell become functional complete.
Supply and packing with Pea gravel of 8mm to 4.6mm size of approved quality as ordered to packed around the casing/slotted pipe in bore well etc complete all as specified and directed.
Development of tube well by compressed air with compressor of minimum capacity of 150 PSI and 450 CFM all as specified. Note:- (i) Yield test for the bore well by continuously pumping to determine safe pumping yield to be carried out by contractor at site and necessary report to be submitted. (ii) Testing of water for potability, dissolved solids, physical/chemical and bacteriological testing etc from the govt lab shall be carried out by the contractor all as directed and test report shall be submitted. (iii) The rates quoted shall deemed to include the above provisions.
S&F housing clamp 90 cm long 20 cm wide out of 6 mm thick MS plate for 200mm dia casing pipe with necessary MS Bolts, nuts & washers at ground level in PCC (1:2:4 ) type B1 using 20mm graded stone aggregate in block etc complete all as specified and directed.
M&L strata sample box of second class hard wood (Hollock / Bijasal ) of size 40cm x 30cm x 20cm etc complete all as directed by Engineer-in charge.
M&L 50mm bore GI medium grade column pipe in 6 m length with flanged joints duly scewed and welded with pipe suspended in deep well complete with slote for lead, GI flanges, rubber gaskat clamps, bolts, nuts, etc compete all as specified and directed.
Supply, laying, jointing/connecting and testing for 80 mm bore steel tubing galvanised medium grade pipe with all fittings, laid in trenches etc complete all as specified and directed.
S&F non return valve cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc complete ISI marked of size 80 mm bore for submersible pump etc complete all as specified as directed.
S&F sluice valve, cast copper alloy, PN 1.6, of size 80mm dia complete including connecting etc complete all as specified as directed.
Supply, installation, testing and commissining submersible pump set electric driven 3 phase, 415 volt, 50 c/s having discharge upto 14000 Lit / hrs at 200m head 18 stage not less than 20 HP etc complete all as specified as directed. Make- KSB/Kirlosker/CG.
S&F 1100 Volts grade submersible cable flat 3 core with copper conductor 10 sqmm stranded fixed to column pipes with suitable clamps jointing material etc complete all as specified and as directed.
Supply & laying in trenches or passing through pipe/fixed to pole/wall PVC insulated and PVC sheathed armoured heavy duty electrical cable with multistranded aluminium conductor 1100 volts grade 25 Sqmm 3.5 core etc complete all as specified and directed.
M&L GI pipe (light grade) for protection of LT Cable fixed to wall/poles /road crossing including clamps complete of size 40/50mm bore complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate eletrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5meters below normal ground level, connecting to galvanised earth strip 25x4mm by means of bolts, nuts check nuts and washer of galvanised iron or steelupto test point all as shown in electrical plate No 3 of SSR Part-I connected to test point incl PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40mm dia for earth lead protection from earth plate to test point and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified including testing on completion.
M&L providing cement concrete in foundation, filling and mass concrete all including required from work etc complete type B-2 (1:2:4) for sealing bacteriological treatment/surface etc complete all as specified and directed.
M&L connection GI pipe line 80 mm to CI/GI water mains of size 80/100 mm dia with CI/GI joints & fittings and necessary connecting accessories etc complete all as specified and directed.
S&F analog water flow meter cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc complete ISI marked of size 80 mm bore for submersible pump etc complete all as specified and directed.
Taking down old unserserviceable ACSR Conductor and GI wire of any size from LT Poles and removing from site etc complete all as specified and directed.
Taking down old unserserviceable GI Earth wire/Guard wire etc. of any size from LT Poles and removing from site etc complete all as specified and directed.
Dismantling and taking down of old unserviceable pin type/ shackle type insulators and from any height of electric pole, complete all as specified and directed.
Taking down old unserviceable cross -arms/Clamps/nut bolts and Angle section etc from LT Pole any size, etc complete all as specified and directed.
Dismantling and taking down old unserserviceable stay assembly from LT Poles and removing from site etc complete all as directed.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule etc complete all as specified.
M&L for PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in coping/pedestal of poles including providing necessary form work for fair finished exposed concrete surfaces complete all as specified and as directed.
Supply, laying, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core cable laid in trenches/pasing through pipe under road crossing etc all as specified and directed.
All as per item No 36.00 but size 70 Sqmm 3.5 Core.
All as per item No 36.00 but size 35 Sqmm 3.5 Core.
All as per item No 36.00 but size 25 Sqmm 4.0 Core.
All as per item No 36.00 but size 25 Sqmm 2.0 Core.
All as per item No 36.00 but size 16 Sqmm 4.0 Core.
All as per item No 36.00 but size 16 Sqmm 2.0 Core.
Boring of holes under road,pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 80mm dia suitable for 0.4 mpa working pressure.
M&L Galvanized iron tubing, 50 mm bore medium grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI tube complete. Make : Prakash/Jindal/Surya.
Supply & errecting Cable path indicators for LT Cable made of CI plate fixed on MS angle iron size 25x25x5mm and 60 Cm long. and fixing in ground 30 Cm below ground level in PCC 1:3:6 type B-1 using 40mm grade stone aggregate of size 30x30x30cm . Cable path indicators shall be provided at distance of every 30 meters and at cable joints and turning of all cables and incorporated LT 1100 Volts on it. including PCC & earth work complete all as specified and directed.
Supply and fix for pole mounted junction box made out of one piece moulded SMC IP-65 protection having aluminium bus bars 100 Amp single phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance free size 300x200x100 mm fixing on pole with MS flat 25x3mm clamp including nut bolts front openable all as specified and directed. Make : Sintex/Finolex/Universal.
Supply and fix for pole mounted junction box made out of one piece moulded SMC IP-65 protection having aluminium bus bars 100 Amp three phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance free size 300x200x100 mm fixing on pole with MS flat 25x3mm clamp including nut bolts front openable all as specified and directed. Make : Sintex/Finolex/Universal.
S&F 2.5 sq mm PVC insulated & sheathed cable twin core copper conductor cable from street light junction box/feeder piller to street light fittings complete all as specified and directed. Make of cable : Havells/Finolex/Polycab.
Supply and fixing of steel conduit pipe of size 20mm dia (fixed to poles with required size of flat iron 25mm x 3mm clamps, bolts, nuts) from junction box to street light fitting and making necessary connection at street light pole and fixing accessories complete Make of steel conduit : Jindal/Prakash/Surya.
S&F street light bracket made to shape at required angle made out of 40mm dia (light grade) GI tubing of length not less than 1.5m long fixing on wall/pole suitable for holding street light fittings including mild steel flat iron 50 x 6 mm clamp 02 Nos with nuts, bolts & washers complete all as specified and directed.
M&L load line distribution board TPN 4 way vertical type with and including provission for adjustable thermal magnetic (63-100) Amps TP MCCB as incommer and MCB's - SP/DP/TP as out going, suitable for for IP-20 complete of Make : Havells/HPL/C&S.
M&L adjustable thermal magnetic 3 pole MCCB (63-100) Amp 50Hz 415 volts with rupturing cap 25KA of Make : Havells/HPL/C&S.
S&F steel tubular swaged pole 09 meter long type 410 SP-31 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.20 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint over a coat of aluminium red oxide primer to remaining portion of pole and marking pole number and including dismantling and taking down old unserviceable pre-stressed concrete pole 09 metre long all as specified & as directed. Note : Excavation & earthwork, PCC in foundation & coping shall be measured and paid for separately. Make : NTC Kanpur/India tube co/Jindal steel/Bombay tubes.
M&L for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation of stay assembly & poles and similar works complete all as specified.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate in mass concrete for pole all as directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B2 using 20 mm graded stone aggregate in coping concrete for pole all as directed by Engineer-in-Charge.
Fixing only retrived machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15650-2008 of 60mm thickness, M-35 grade with grey cement and no pigment except tiles, including taking down and 25cm thick sand cushioning complete all as specified and directed. (Note:-Sand cushion will be measured and paid separately).
S&F in repair LED street light fitting 120 watt 230V AC outdoor type with high pressure die cast aluminium housing 50mm dia and heat resistant complete with driver, lamp, bracket, clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete. Make : Havells/HPL/Bajaj/Shakti.
DEMROT ELECTRICAL WORKS
M/s ASK Enterprises
M/S GAURI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .