| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 12 53 CHOPASNI HOUSING BOARD JODHPUR 342008 | JODHPUR | RAJASTHAN | 342008 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹26.1 L+₹9.8 L (60.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | PANKAJ ENTERPRISES L1 | SNEH CORPORATION L2 |
|---|---|---|---|---|---|
| 1.00 | M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (Scale off or equivalent) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 2x10 TR all as specified and as directed(Logistic & BTF ) | 2 | Each Job | 15,000 ₹30,000 | 12,500 ₹25,000 Lowest |
| 2.00 | M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (Scale off or equivalent) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 3x37.5 TR all as specified and as directed(Auditorium) | 1 | Each Job | 20,000 ₹20,000 Lowest | 22,000 ₹22,000 |
| 3.00 | M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (Scale off or equivalent) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 3x 56.5 TR-WSA Shed 3 specified and as directed. | 1 | Each Job | 25,000 ₹25,000 Lowest | 32,000 ₹32,000 |
| 4.00 | Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 10 TR capacity ( BTF,Logistic) | 2 | Each Job | 2,000 ₹4,000 | 1,950 ₹3,900 Lowest |
| 5.00 | Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 37.5 TR capacity (Auditorium) | 2 | Each Job | 2,500 ₹5,000 | 1,950 ₹3,900 Lowest |
| 6.00 | Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 56.5 TR capacity WSA) | 2 | Each Job | 2,500 ₹5,000 | 2,100 ₹4,200 Lowest |
| 7.00 | M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen to maintain adequate pressure in the system, restoring the leaks including S&F replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/ suction/ discharge valves of compressors, gland packages of all angle valves flaring of all connections framing welding etc complete for AC plant Auditourium,WSA,BTF and Logistics | 4 | Each Job | 7,000 ₹28,000 Lowest | 8,500 ₹34,000 |
| 8.00 | Opening the upper sheet / side sheet of Cooling tower Cleaning, servicing of Chiller type AC Plant of any capacity / model / make for access to reserve water tank, cooling fan & cooling fins etc, M&L for washing/cleaning of cooling tower internally/ externally including cooling fins etc with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing all as specified and as directed | 5 | Each Job | 3,000 ₹15,000 Lowest | 4,990 ₹24,950 |
| 9.00 | Servicing, greasing of centrifugal pump set couple type three phase 415 volts, upto 5/7.5 HP at suitable for monoblock pump/AHU/Compressor etc of any model/Make, strip opening and taking out or rotor carefully, cleaning of rotor and stator, with out damage to stator body, changing of bearing, including assembling all dessembled components, packing, testing of motor to its full load capacity at desired RPM/torque after coupling with pumpset etc on site complete all as specified and directed. | 12 | Each Job | 2,000 ₹24,000 Lowest | 4,520 ₹54,240 |
| 10.00 | Servicing, greasing of centrifugal pump set couple type three phase 415 volts, upto 2/3 HP at suitable for monoblock pump/AHU/Compressor etc of any model/Make, strip opening and taking out or rotor carefully, cleaning of rotor and stator, with out damage to stator body, changing of bearing, including assembling all dessembled components, packing, testing of motor to its full load capacity at desired RPM/torque after coupling with pumpset etc on site complete all as specified and directed. | 8 | Each Job | 1,500 ₹12,000 Lowest | 3,580 ₹28,640 |
Tender Value
₹17.5 L
EMD Value
₹34,000
Closing Date
5 May 2025, 6:00 pmClosed
CWE (AF) Jaisalmer
HQ CWE (AF) Jaislmer
REPAIR AND MAINT AND REPLACEMENT OF DEFECTIVE COMPONENTS OF CHILLER PLANTS AT AIR FORCE STATION UTARLAI
2025_MES_698012_3
80337
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE (AF) Utarlai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹34,000
25 Aug 2025
16 Apr 2025
6 May 2025
16 Apr 2025
5 May 2025
23 Apr 2025
Amount
M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (Scale off or equivalent) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 2x10 TR all as specified and as directed(Logistic & BTF )
M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (Scale off or equivalent) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 3x37.5 TR all as specified and as directed(Auditorium)
M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (Scale off or equivalent) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 3x 56.5 TR-WSA Shed 3 specified and as directed.
Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 10 TR capacity ( BTF,Logistic)
Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 37.5 TR capacity (Auditorium)
Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 56.5 TR capacity WSA)
M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen to maintain adequate pressure in the system, restoring the leaks including S&F replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/ suction/ discharge valves of compressors, gland packages of all angle valves flaring of all connections framing welding etc complete for AC plant Auditourium,WSA,BTF and Logistics
Opening the upper sheet / side sheet of Cooling tower Cleaning, servicing of Chiller type AC Plant of any capacity / model / make for access to reserve water tank, cooling fan & cooling fins etc, M&L for washing/cleaning of cooling tower internally/ externally including cooling fins etc with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing all as specified and as directed
Servicing, greasing of centrifugal pump set couple type three phase 415 volts, upto 5/7.5 HP at suitable for monoblock pump/AHU/Compressor etc of any model/Make, strip opening and taking out or rotor carefully, cleaning of rotor and stator, with out damage to stator body, changing of bearing, including assembling all dessembled components, packing, testing of motor to its full load capacity at desired RPM/torque after coupling with pumpset etc on site complete all as specified and directed.
Servicing, greasing of centrifugal pump set couple type three phase 415 volts, upto 2/3 HP at suitable for monoblock pump/AHU/Compressor etc of any model/Make, strip opening and taking out or rotor carefully, cleaning of rotor and stator, with out damage to stator body, changing of bearing, including assembling all dessembled components, packing, testing of motor to its full load capacity at desired RPM/torque after coupling with pumpset etc on site complete all as specified and directed.
Supply & Fixing in replacement of water pressure gauge 96mm dia as per existing pressure for chiller / condenser pipeline testing complete including taking out old /unserviceable gauged complete all as specified and directed.
Supply & Fixing in replacement of water temperature gauge as per existing make and model for chiller / condenser pipeline testing complete including taking out old /unserviceable gauged complete all as specified and directed.
Supply and fix in replacement of Micro processor based PCB card and display unit for 37.5 TR capacity water cooled scroll chiller AC plant control as per OEM including pre-programmed software to control all parameter and chiller unit etc complete including taking down old one all as specified and directed.
Supply and fix in replacement of Micro processor based PCB card and display unit for 56.5 TR capacity water cooled scroll chiller AC plant control as per OEM including pre-programmed software to control all parameter and chiller unit etc complete including taking down old one all as specified and directed.
Supply and fix in replacement of Micro processor based PCB card and display unit for 13 TR capacity water cooled scroll chiller AC plant control as per OEM including pre-programmed software to control all parameter and chiller unit etc complete including taking down old one all as specified and directed.
Supply and fix in replacement of Micro processor based PCB card and display unit for 10 TR capacity water cooled scroll chiller AC plant control as per OEM including pre-programmed software to control all parameter and chiller unit etc complete including taking down old one all as specified and directed.
Supply and fix in replacement of Drier Filter suitable for ductable type AC Plant size 5/8" complete including taking down old one all as specified and directed.
Dismantling of unserviceable centrifugal pump set couple type three phase 415 volts, up to 7.5 HP at suitable for chiller line/ condensing line Compressor etc of any model/Make, strip opening and taking out or rotor carefully, cleaning of rotor and stator, taking out burnt stator winding without damage to stator body, rewinding the eclectic motor by super enameled copper conductor (Wire) including providing insulating Mika paper in stator slots, PVC sleeves, varnish the winding complete, assembling the motor including replacement of studs with nuts, testing of motor to its full load capacity at desired RPM/torque after coupling with pump set etc including transportation to civil workshop and alignment in same vice -versa completeafter replacing accessories as under:- (a) Gland bush , studs, nuts & washers (b) Ball bearing of pump set (c) Re-melting grinding and polishing of pump shaft as per existing size and shape complete. (d) Gland packing, greasing in pump bearings and making its proper alignment etc
Dismantling of unserviceable centrifugal pump set couple type three phase 415 volts, 3 to 5 HP at suitable for chiller line/ condensing line Compressor etc of any model/Make, strip opening and taking out or rotor carefully, cleaning of rotor and stator, taking out burnt stator winding without damage to stator body, rewinding the eclectic motor by super enameled copper conductor (Wire) including providing insulating Mika paper in stator slots, PVC sleeves, varnish the winding complete, assembling the motor including replacement of studs with nuts, testing of motor to its full load capacity at desired RPM/torque after coupling with pump set etc including transportation to civil workshop and alignment in same vice -versa completeafter replacing accessories as under:- (a) Gland bush , studs, nuts & washers (b) Ball bearing of pump set (c) Re-melting grinding and polishing of pump shaft as per existing size and shape complete. (d) Gland packing, greasing in pump bearings and making its proper alignment etc
Dismantling of unserviceable cooling tower motor of size 1 to 3 HP 3 phase 415 volts, strip opening and taking out of rotor carefully, cleaning of rotor and stator, taking out burnt stator winding with out damage to stator body, rewinding the eclectic motor by super enameled copper conductor (Wire) including providing insulating Mika paper in stator slots, PVC sleeves, varnish the winding complete, assembling the motor including replacement of studs with nuts, testing of motor to its full load capacity at desired RPM/torque after coupling with pumpset etc including transportation to civil workshop and vice -versa complete all as specified and directed by Engineer-in-Chrage.
Dismantling of unserviceable cooling tower motor of size 3 to 5 HP 3 phase 415 volts, strip opening and taking out of rotor carefully, cleaning of rotor and stator, taking out burnt stator winding with out damage to stator body, rewinding the eclectic motor by super enameled copper conductor (Wire) including providing insulating Mika paper in stator slots, PVC sleeves, varnish the winding complete, assembling the motor including replacement of studs with nuts, testing of motor to its full load capacity at desired RPM/torque after coupling with pumpset etc including transportation to civil workshop and vice -versa complete all as specified and directed by Engineer-in-Chrage.
Supply & fix in replacement of Micro processor based relay 5 amp to 60 amp including timer as per existing make and model including taking down old one complete all as specified and directed.
S&F in replacement of LP cut off control cut out 12 volt suitable for 10 TR, 37.5 TR & 56.5TR AC plant of capacity including taking down old one complete all as specified and directed.
S&F in replacement of HP cut off control cut out 12 Volt suitable for 10 TR, 37.5 TR & 56.5TR AC plant of capacity including taking down old one complete all as specified and directed.
S&F repair LP sensor 12 volt suitable for Scroll type AC of capacity10 TR, 37.5 TR & 56.5TR including taking down old onecomplete all as specified and directed. Make: - Danfoss / Indo Foss or equivalent make as approved by GE.
S&F repair HP Sensor 12 Volt suitable for 10 TR, 37.5 TR & 56.5TR AC of capacity including taking down old one complete all as specified and directed by Engineer-in-charge. Make: - Danfoss/Indo Foss or equivalent make as approved by GE.
S&F in replacement of 3 Pole contactor 25/40 A as per existing make and model including taking down old one all as specified and directed by Engineer-in-charge.
S&F in replacement of 3 Pole contactor 50/60/80 A as per existing make and model including taking down old one all as specified and directed by Engineer-in-charge.
S&F in replacement of Expansion valve suitable for 37.5 & 56.5 TR AC plant including taking down old one complete all as specified and directed by Engineer-in-charge. Make: - Danfoss or equivalent make as approved by GE.
S&F in replacement of Air release valve 15/20/25mm dia for chiller plant including taking down old one complete all as specified and directed.
S&F in replacement of Single phase preventer Make Minilec /GIC suitable for 37.5 & 56. 5 TR AC plant including taking down old one complete all as specified and directed by Engineer- in - Charge.
S&F in replacement of AHU belt of suitable size as per Existing belt including taking down old one complete all as specified and directed by Engineer-in-charge.
S&F in replacement of inlet/outlet sensors suitable for 10 TR, 37.5 TR & 56.5TR Capacity AC plant including taking down old one complete all as specified and directed by Engineer-in-charge.
M & L cleaning in strainer and filter at main suction pipe line including taking down old one complete all as specified and directed by Engineer-in-charge.
Inspection of packaged type AC plant of any capacity of any type by opening the condenser unit fixed on roof top/ground floor and cooling unit fixed inside the building, and servicing, cleaning/removing the dust and filter, blower, fan motor, compressor, washing/ cleaning the outer surface and testing including making good surface/ ceiling if necessary checking of refrigerant standing pressure complete all as directed by Engineer-in-Charge. .Note: (i) New spare parts/items required in replacement of old defective spare parts/items shall be measured and paid separately under respective items.(ii) Refrigerant required for topping (R22 / R-134/ R410(a)/407 shall be measured and paid for separately (iii) Cost of transportation of air conditioner required being repair/replacement from site to workshop for repair ,and re fix at site after repair shall be deemed included in quoted rates.
S&F in replacement of Blade for condensing fan motor of capacity 7.5TR including taking down old one complete all as specified and directed.
S&F in replacement of Blade for condensing fan motor of capacity 8.5 TR including taking down old one complete all as specified and directed.
S&F in replacement of condenser fan motor of ductable split type AC of 7.5 TR capacity of makeCarrier / Hitachi / Voltas Blue starincluding taking down old unserviceable all as directed by Engineer-in-Charge.
S&F in replacement of condenser fan motor of ductable split type AC of 8.5 TR capacity of makeCarrier / Hitachi / Voltas Blue starincluding taking down old unserviceable all as directed by Engineer-in-Charge.
S&F in replacement of mounting assembly suitable for condensor fan motor of 7.5/8.5 TR capacity including taking down old one all as directed.
S&F in replacement of blower fan motor of ductable split type AC of 7.5/8.5 TR capacity of make Carrier / Hitachi / Voltas Blue star,including taking down old unserviceable all as directed by Engineer-in-Charge.
M & L for Refrigerant gas R 22/R-438/R-134 in company sealed cylinder of capacity all as directed by Engr-in-charge
M & L for Refrigerant gasR-410(a)/407 (a) in company sealed cylinder of capacity all as directed by Engr-in-charge
S & F in replacement of PCB Sensor unit with wire remote control of ductable split AC indoor unit of Capacity 7.5/8.5 TR suitable for ,Hitachi removing old PCB and refix with new PCB of same make, model & capacity and model in the same position complete all as directed by Engr in Charge
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including flushing with nitrogen gas to cold charging line condenser coil and cleaning the blower unit ,filter for package type AC complete all as specified & as directed.
Supply & fix for PVC cable flexible round 4 Core Copper conductor 6 sqmm including taking down old unsv cable complete all as specified and directed.
Supply & fix in replacement of PVC cable flexible round 4 Core Copper conductor 10 sqmm including taking down old unsv cable complete all as specified and directed.
M&L in replacement of Water flow switch for AC plant 13/19/375/56 TR capacity with welding work in pipe line and fixing of MS socket, including control wiring complete including taking down old one complete all as specified and directed.
Supply and fix for FM approved highly flexible thermal insulation elestomeric foam based on synthetic rubber laminated with 12 micron aluminium foil 19mm thick in replacement of thermocoal insulation complete all as specified and directed.
S&F in replacement of compressor for chiller type AC plant electrically / mechanically from the system, removal, lowering to the ground unserviceable reciprocating type compressor Make: Danfoss/ Kirloskar / Tecumseh / Hitachi/ Carrier 13 TR Capacity, operated onR 407c/ R410a/413 gas and 3 phase 415 volts electric supply for repair/replacement.
M&L for replacement of damaged insulation of chilled water pipeline and valves for chilled water piping of 100 mm dia pipe complete all as specified & as directed.
M&L for replacement of damaged insulation of chilled water pipeline and valves for chilled water piping of 65 mm dia pipe complete all as specified & as directed.
M&L for replacement of damaged insulation of chilled water pipeline and valves for chilled water piping of 50 mm dia pipe complete all as specified & as directed.
Supply, fixing & installation in replacement of NRV ISI marked, flanged both edges suitable for 125 mm bore pipe, including rubber joints, nuts, bolts, gaskets & washers, testing complete including taking out old /unserviceable valve complete all as specified and directed by Engineer-in-Charge.
Supply, fixing & installation in replacement of NRV ISI marked, flanged both edges suitable for 100 mm bore pipe, including rubber joints, nuts, bolts, gaskets & washers, testing complete including taking out old /unserviceable valve complete all as specified and directed by Engineer-in-Charge.
M&L for repair for humidifier including cleaning of tank, replacement of heater of 2 KW, painting of tank with corrosion less paint, rewiring of electrical panel as directed by Engineer-in-Charge.
M&L for replacemet of electrical strip heater, finned type, capacity 2 KW consisting of staniness steel sheathing having heat resistent chrome-nickel 80/20 element protected under best insultion to avoid the leakage of current and with screwed type terminal at one end, 240 Volts, AC, 50 Hz, single phase complete all as specified and as directed.
Supply, installation, testing and commissioning in repair of 3 way mising/ diverting actuator valve of size 65 mm dia with proportional cooling only thermostats for the Air Handling Units complete with required controls wiring/ installation kit etc. As per specifications and make existing on site as directed.
M&L for painting of AC plant complete equipments (MS pipes, cooling tower, chiller unit, pumps and motors) with proper color code, removal of rust and old paint and painting of SM/ MES No of machines as per directed by Engineer-in-Charge.
S&F in replacement of air filer for AHU, Filter section consists of 50 mm thick washable HDPE 90% down 10 micron pre-filters, AHU pre filler having HDPE media with aluminium/GI frame & filter as per the existing size of 600mmx600mmx50/40mm complete all as specified and directed.
Supply and fix in replacement of Cooling Tower Sprinkler Assembly such as Sprinkler, Sprinkler Pipe, Elimentor, Tension bar and Turn buckle for Cooling Tower capacity 160/120/100 TR as existing on site complete all as specified and directed.
S&F in replacement of PN 1.6 butterfly valves size 125mm duly insulated with companion flanges, nuts, bolts, gaskets & washers etc. as specified butterfly valves with cast iron body, seat of black nitrile rubber, nylon coaed S.G. iron disc, epoxy power coaed shaft AISI 410 etc. complete all as specified and directed.
S&F in replacement of PN 1.6 butterfly valves size 80mm duly insulated with companion flanges, nuts, bolts, gaskets & washers etc. as specified butterfly valves with cast iron body, seat of black nitrile rubber, nylon coaed S.G. iron disc, epoxy power coaed shaft AISI 410 etc. complete all as specified and directed.
S&F in replacement of PN 1.6 butterfly valves size 65mm duly insulated with companion flanges, nuts, bolts, gaskets & washers etc. as specified butterfly valves with cast iron body, seat of black nitrile rubber, nylon coaed S.G. iron disc, epoxy power coaed shaft AISI 410 etc. complete all as specified and directed.
S&F in replacement of PN 1.6 butterfly valves size 50mm duly insulated with companion flanges, nuts, bolts, gaskets & washers etc. as specified butterfly valves with cast iron body, seat of black nitrile rubber, nylon coaed S.G. iron disc, epoxy power coaed shaft AISI 410 etc. complete all as specified and directed.
S&F of cooling tower PVC honey comb fills in colums of size 600 mm x 300 mm x 150 mm size and min wt 600 gram of capacity 15 TR to 150 TR for the following make: Kool Drop/ MIHIR/ ADVANCE/ HIMGIRI per existing specification and requirement.
S&F in replacement of rotational moulded polyethylene water storage tanks of capacity 1000 litre (cylindrical vertical with closed top) hoisted and fixed in postion complete all as specified and directed.
Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 50mm dia complete all as specified and directed.
Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 65mm dia complete all as specified and directed.
Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 80mm dia complete all as specified and directed.
S&F in repair Y staineer fillter as per existing size and make complete all as specified and directed.
S&F in replacement of GI Pipe medium grade of size 25mm used in AC plant with required accessories and labour with all fittings laid in floors or fixed to walls and ceilings etc complete all as specified and directed.
S&F thermometr humidity meter clock with sensor cable Temperature and Humidity Functions: With temperature range from - 10 deg C to +50 deg C and humidity 10 % sim 99 % RH, temperature and humidity readings show directly all as per directed.
S&F in replacement of MCB TP C 40/32Amps 415 Volts complete all as specified and directed.
SNEH CORPORATION (BID ID -3288441)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .