Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC | ₹2.5 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹3.0 Cr+₹51.7 L (21.0%)Accepted-AOC | ₹3.0 Cr+₹51.7 L (21.0%) | L2 | Accepted-AOC Accepted |
| 3 | L3₹3.0 Cr+₹52.4 L (21.3%)Accepted-AOC | ₹3.0 Cr+₹52.4 L (21.3%) | L3 | Accepted-AOC Accepted |
| 4 | L4₹3.1 Cr+₹59.2 L (24.0%)Accepted-AOC | ₹3.1 Cr+₹59.2 L (24.0%) | L4 | Accepted-AOC Accepted |
| 5 | L5₹3.2 Cr+₹71.6 L (29.0%)Accepted-AOC 3 4 520 TO 526 FLAT NO 303 PRAGATHI PRIDE APARTMENT BARKATHPURA HYDERABAD 500027 | HYDERABAD | TELANGANA | 500027 | ₹3.2 Cr+₹71.6 L (29.0%) | L5 | Accepted-AOC Accepted |
Tender Value
₹2.8 Cr
EMD Value
₹5.6 L
Closing Date
15 Sept 2021, 3:00 pmClosed
CCE(RND) SOUTH
PB No 1569, Akbar Road, Secunderabad
PROVISION OF ADDITION AND ALTERATION OF EXISTING HARDWARE STORAGE HANGAR AND CERTAIN CIVIL AND MISCELLANEOUS WORKS AT TECHNICAL HANGAR OF ASL AT RCI, HYDERABAD
2021_DRDO_644092_1
83616/CIV/TH/CON
Limited
Civil Works
Item Rate
450 days
RCI
as Per NIT
2 documents required · 2 mandatory
₹2,000
Yes
CCE(RND)S SECUNDERABAD
₹5.6 L
Yes
12 Nov 2021
18 Aug 2021
16 Sept 2021
18 Aug 2021
15 Sept 2021
27 Aug 2021
19 Aug 2021 - 26 Aug 2021
Amount
SUBHEAD - I : DISMANTLING :
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
SUBHEAD - II : EARTH WORK :
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (a) All kinds of soil.
b)Ordinary rock
c)Hard rock (Blasting prohibited)
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil.
Excavation Work by Mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
a)Ordinary rock
b)Hard rock (Blasting prohibited)
Filling Available Excavated Earth (Excluding Rock) in trenches,Plinth sides of foundatios etc,in layers not exceeding 20cm in depth consolidating each diposited layer by ramming and watering,lead upto 50meter and lead upto 1.5meter
Supplying and filling of approved earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Credit of Hard rock
SUB HEAD - III : ANTI TERMITE TREATMENT WORK:
Supplying chemical emulsion in sealed containers including delivery as specified. (a) Chlorpyriphos/ Lindane emulsifiable concentrate of 20%.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: (i) With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (a) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: (i) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
SUB HEAD - IV : PLAIN AND REINFORCED CEMENT CONCRETE WORK:
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : a) 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position Machine Batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
a) All works upto plinth level.
b) All works above plinth level upto floor V level.
c) Extra for Deduction of not pumping of concrete to site of laying.
Providing and laying in position Ready Mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately)
a) All works upto plinth level.
b) All works above plinth level upto floor V level.
c) Add / Deduct for using extra cement in the items of design mix over and above the specified cement content therein.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
a)Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) including Providing & applying a coat of DAMP PROOF membrane approved on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification ( per 50 kg cement).
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundations, footings, bases of columns etc. for mass concrete.
b) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
c) Suspended floors, roofs, landings, balconies and access platform.
d) Lintels, beams, plinth beams, girders, bressumers and cantilevers
e) Columns, Pillars, Piers, Abutments, Posts and Struts.
f) Stairs, (excluding landings) except spiral-staircases
g) Weather shade, Chajjas, corbels etc., including edges.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
SUB HEAD - V : BRICK WORK:
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : (a) Cement mortar 1:6 (1 cement : 6 coarse sand.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
SUB HEAD - VI : PLASTERING & FINISHING :
Providing of 6mm cement plaster of mix in all surface with (a) cement mortar 1:3 (1 cement : 3 fine sand) at all levels.
Providing of 12 mm cement plaster of mix in all surface with (a) cement mortar 1:6 (1 cement : 6 fine sand) at all levels.
Providing of 15 mm cement plaster on the rough side of single or half brick / C.C wall of mix: (a) 1:6 (1 cement : 6 fine sand) at all levels.
Providing and Applying two coats of oil bound distemper of approved brand and shade over and including one coat of primer, including preparation of surface etc.,complete as directed.& with plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work.
Providing and applying two coats of synthetic enamel paint of approved brand and shade over a coat of primer including preparation of surface and applying approved brand putty on following surfaces at all levels and locations etc., complete. Steel surfaces with zinc chromate primer.
Varnishing with varnish of approved brand and manufacture : (a) Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. Including with French spirit polishing : (b) Two or more coats on new works including a coat of wood filler.
Providing & fixing chicken wire mesh at the junctions of RCC and C.C , 200mm overlapping on both sides with all necessary hardware etc., complete with guage and mesh size - 20swg and 20mm mesh
SUB HEAD - VII : FLOORING WORK:
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Polished Granite stone slabs 18 mm thick in steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying double charged vitrified floor tiles of Size 600x600 mm.(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Made of NITCO Company :Model name -Bermuda or Made of Somany ompany :Model name Celestial /Elegance series or Made of Kajaria company :Model name Super Glossy Nanotech K-6016/6018/6019/6101/6012 & Jhonson Make : Quarzet DK & Quarzet HL Or Equivalent
Providing and laying double charged Vitrified tiles of Size 600x600 mm. (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including routing the joint with white cement & matching pigments etc.Made of NITCO Company :Model name -Bermuda or Made of Somany ompany :Model name Celestial /Elegance series or Made of Kajaria company :Model name Super Glossy Nanotech K-6016/6018/6019/6101/6012 , Jhonson Make : Quarzet DK & Quarzet HL Or Equivalent.
Providing and laying rectified Glazed Non skid Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Make of NITCO Company : Model name Exotica/Maxima series or ,Made of Somany Company : Model name Trecker/Sprinkler series or , Made of Kajaria Company : Model Name GaniliaCrema /Beige/Almono Made of Johnson /Equivalent
Providing and fixing Ist quality Ceramic glazed wall tiles of Size 300x600 conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades as approved by Engineer-in-Charge, in skirting, and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Makes : Johanson , sandex Series or equivalent
SUB HEAD - VIII : WOOD WORK / UPVC WORK :
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
(Profile C) Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing in position collapsible steel shutters with vertical channels and braced with flat iron diagonals, with top and bottom rail of T-iron, with steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 38 mm thick including ISI marked Stainless Steel butt hinges with necessary screws including Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.
Extra for Not Providing and fixing ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc. complete : (a) 125x90x4.00 mm.
Providing and fixing factory made UPVC white colour sliding or openable glazed window upto 1.65 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from roll forming process of requiredlength (shape & size according to uPVC profile), appropriate dimension of uPVCextruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile,zinc alloy (white powder coated) touch locks with hook, zinc alloy body with singlenylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm sizefor fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame & sash shall be mitred cut and fusion welded at all corners, includingdrilling of holes for fixing hardware's and drainage of water etc.
After fixing framethe gap between frame and adjacent finished wall shall be filled with weather proofsilicon sealent over backer rod of required size and of approved quality, all completeas per approved drawing & direction of Engineer-in-Charge. (Single / double glasspanes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance indimension i.e. in depth & width of profile shall be acceptable. Variation inprofile dimension in higher side shall be accepted but no extra payment onthis account shall be made of approved make
a)Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
Providing and fixing glazing in upvc door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the Architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
a)With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (a) Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete : a) 300x16 mm.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : a) 150x10 mm.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : a) 125 mm.
Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. a) Twin rubber stopper.
Providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. comp
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, with necessary accessories and screws etc. complete.
Providing and fixing stainless steel ( Grade 317) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing 12 mm thick toughened glass door with shutter ofapproved brand and manufacture, including providing and fixing top & bottompivot & double acting hydraulic floor spring type fixing arrangement and makingnecessary holes etc. for fixing required door fittings with all accessores, all complete as per directionof Engineer-in-charge
Providing and fixing 12 mm thick toughened glass of approved brand and manufacture, fixing arrangement and making necessary holes etc. for fixing , all complete as per direction of Engineer-in-charge
Supplying and fixing Rolling Shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing & fixing of galvalume sheet of approved colour and manufature on ceiling/ roof supported over aluminium section frame work fixed with dash fastner etc complete as per manufacture specifications and direction of the project engineer including necessary scafolding all as directed by the engineer
Supply and installation horizontal roller blinds made out of imported fabric including of all hardware fitting like cord, rope, brackets etc all complete of Vista make or equivalent.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
SUB HEAD - IX : ROOFING, WATER PROOFING & FALSE CEILING WORK
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (i) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (ii) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
(iii) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (iv) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (v) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm).
Providing and fixing on wall face unplasticised Rigid Single socketed PVC rain water pipes conforming to IS : 13592 Type A, along with injection moulded fittings as required e.g., bends on any angle, sockets, junction, cowls, offsets, access pieces, including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, providing and fixing MS stays & clamps and cutting & making good the holes in floors and walls wherever required etc. all complete. (For Rain water pipe).
(a) 150 mm diameter.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.
wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturer's specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong)
REPAIR OF EXISTING ROOF SHEETS, FIXING OF NEW BOLTS, WASHERS ETC
SUB HEAD - X : SANITARY INSTALLATIONS WORK :
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :Size : 71 x36 x 81 cm (Cat no:- 20101 (s-22)) (a) W.C. pan with ISI marked white solid plastic seat and lid. (Make : Hindware,Jaquar or equivalent)
Providing and fixing white vitreous china flat back smalll urinal of size 26.5 X 31.5 X 44 CM with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the walls and floors wherever required : (a) Single half stall urinal P.V.C. manual flushing cistern (Make : Hindware,Jaquar or equivalent).
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (a) White Vitreous China Table Top Basin (Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. -10001)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in- charge.(Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. -F850015)
Providing and fixing Stainless steel connection for flush pipe of Grade 304 stainless steel connecting with wash basin, W.C. pan.(Make-Alton ALT2005,Havells or equivalent)
Providing and fixing 600 x 300 mm beveled edge Mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete as per the direction of Engineer-in- charge.(Make : Saint Gobain ,Cera or equivalent) model-5567
Providing and fixing toilet paper holder : (a) C.P. brass.(Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. -F880003)
Providing and fixing liquid soap container of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (Make : Jaquar or equivalent)
Providing and fixing CP liquid soap dish (brass) 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 205gms. (Make : Jaquar or equivalent)(Hindware Cat. No. F880011)
Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (a) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.(Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. F880005)
Providing and fixing C.P. brass bib cock with wall flange of approved quality conforming to IS:8931 : (a) 15 mm nominal bore (Make : Jaquar or equivalent)
Providing and fixing C.P. brass Angular stop cock (concealed) of standard design and of approved make conforming to IS:8931 as per the direction of Engineer-in- charge.(Model No, - CON-CHR-059KN) (a)15 mm nominal bore.(Make : Jaquar or equivalent)
Providing and Fixing Health Faucet HINDWARE Cat.No-F160068 or JAQUAR Cat. No. 573 (ALLIED SERIES) or equivalent make KINGSTON-AGR ACS 49/KOHLER Cat. No. 12925IN-CP (HEALTH FAUCET W/WHITE SDSPRAY, M HOSE) with flexible pipe and wall hook with each European W.C. Pan.
Providing and fixing Nahani Trap of size 110 X 75mm. (Make : Birla Aerocon or equivalent)
SUBHEAD - XI : SOIL WASTE AND VENT PIPE AND FITTINGS WORK:
Providing and fixing SWR uPVC pipes (Type-B) confirming to IS 13592 : 1992 complete with all fittings e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including fixing the pipes on wall face with MS galvanized holder bat clamps or suspended below ceiling with MS galvanized hangers/supports and fasteners all as approved by the engineer in charge including Cutting holes in walls, floors excavation, refilling and disposal of surplus earth wherever required and making good . (a) 110 mm dia.
Providing and fixing uPVC deep seal 'P' or 'S' of self cleansing design with or without vent arm with provision for connecting uPVC inlet fitting complete including cost of cutting and making good the walls and floors wherever required. (a) For 110mm inlet and 80mm outlet.
Providing and fixing uPVC threaded waste pipes (I.S:4985-2000) Class - 6 including all fittings e.g bends, junctions, elbows, tees, offsets etc. jointing with screwed joints including cutting holes in walls, floors excavation, refilling and disposal of surplus earth wherever required and making good.
(a) 32 mm nominal bore.
(b) 50 mm nominal bore.
(c) 80 mm nominal bore.
SUBHEAD - XII : EXTERNAL WATER SUPPLY SYSTEM:
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work
Supplying and fixing in position best quality and approved make heavy quality screws down gun metal gate valves with hand wheel of the following sizes fixed to service lines including testing, making good the leakages, if any etc.,
a)25mm nominal bore.
b)20mm nominal bore.
(c) 32 mm nominal bore.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work
(a) 32 mm dia nominal bore
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Providing & Fixing HDPE O.H water storage tank of the approved quality, & of the following capacity including making solid supported base as per instructions & doing all connections as required to make the work complete in all respects as approved by Engineer-in-charge.
Providing & fixing sqare mouth S W Gully trap grade A complete with CI grating brick machinery chamber with water tight C I cover with frame of 300x300 mm (Size inside ) The weight of cover to be not less than 4.5 kg & frame to be not less than 2.70 kg as per standard design.
a)100x100 mm size P type.
SUBHEAD - XIII : EXTERNAL SEWERAGE SYSTEM
Excavating trenches of required width for pipes etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
a)80 mm dia. but not exceeding 300 mm dia
Providing and laying of 150 dia s.w pipe including honching around the pipe in 100mm thick with cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
a)150 mm diametre S.W. pipe
b)100 mm diametre S.W. pipe
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : (a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
SUB HEAD - XIV : ROAD & DRAINS
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
a)All kinds of soil
Supply of approved moorum obtained from outside MOD land filling in layers not exceeding 20cms thick at all heights and depths in foundations, pits, trenches, sewer lines around structures and foundation under floors other places including dressing and levelling watering, consolidation to achieve minimium of 95% proctor density etc., complete as per drawing specifications, payments shall be made for the quantity after deducting the voids.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Providing and laying cement concrete :1:2:4 (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) in pavements, laid to required slope and camber in panels as required including mixing of hardening compound of approved quality as per manufacturers specification in cement concrete, consolidation finishing and tamping complete using steel form work with sturdy MS channel sections, curing, making provision for contraction/expansion, construction & longitudinal joints (10mm wide x 50mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (a) All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
(a) All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a)1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
a)Cement mortar 1:6 (1 cement : 6 coarse sand).
Providing of 12 mm cement plaster of mix in all surface with (a) cement mortar 1:6 (1 cement : 6 fine sand) at all levels.
SUB HEAD - XV : HARD STANDING
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge: (a) All kinds of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Supplying and filling in plinth with river sand under floors, including watering,ramming, consolidating and dressing complete.
Supply and laying of moorum (of plasticity index <6) in road embankment to proper grade and level in layer of 200mm thickness and consolidating with road roller to achieve the modified proctor density of 97%, all complete as per drawing, specficiations and directions of Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.
Providing and laying of hard shoulder in dressing,raming,etc. Completed as per direction of the Engineer-in-charge.
SUB HEAD - XVI : WATER COOLER :
Aquaguard Purechill RO storage Cooler cum Purifier with its one of a kind purification technology (RO),with cooling and storage solution of following specification.Approximate External Diamension (WXDXH) 640X450X1350mm Operating Power Supply 230 ±10% V AC,50Hz b)Filter Catridges-Sediment,Activated Carbon,Carbon Block Running Current in Amps.(Max) 4.5 ± 10% Power in Watts(Max) 700 ± 10 % Water Storage Tank Capacity 80Ltr. Capacity with Comfort Level Water Outlet Temperature at 17°C ± 1° C 60 Ltr Compressor Make Copeland or Tecumseh Refrigerant Freon 22 Stages Details.
1.Particulate Filter
2.Pre Carbon Block Filter
3.Anti Scalant Filter
4.Sediment Filter
5.Reverse Osmosis membrane Filter
6.Post Carbon Block Filter
7.Nano Silver Leaching Filter
RO Membrane Rating 4No.x75 GDP or Equivalent Make.Kent/Eureka forces or equivalent
SUB HEAD - XVII: AIR CONDITIONING
Supply, Installation, testing and Commissioning of double skin floor mounted thermal break air handlig unit. The panels made out of 45 +/- 2 mm thick fabricated out of pre coated 0.6 mm thick GI on outer side and 0.6 mm thick plain GI on inner side with PUF insulation density of 38+/-2 Kg/Cu.m. The framework shall be of internally coved extruded aluminum and thermal break hollow sections. AHU shall comprising aluminum airfoil blade low leakage type SA & F/A dampers suitable for manual/motorized operation. pre filter scetion with 10 & 5 micron filters,coil section with 6/4 row INTERLACED/INTERWINTED design DX Cooling coil to make multi distributers for multiple circuits of VRF as per requirement. Insulated SS 304 stainless steel drain pan, fan section with PLUG type FAN, with EFF1 motor, CFL lamps for filter sections & fan sections with on / off switches for operation from outside, limit switch for the fan section & access door with a view glass, fire retardant flexible canvas connection between fan & AHU panel, internal vibration mounts for fan & motor frame, and supply plenum with aluminum airfoil blade low leakage
S/A damper suitable for manual/motorized operation. scope include all the internal wiring of the unit for lamps & limit switch etc. All the internal wiring of the unit for lamps & door interlock controles etc shall be in the scope of the AHU vendor. VRF communication & copper kit to be included in the scope of AHU.
AHU 1 - 24TR capacity, dehumidifier air qty 9600cfm at 65mm Static pressure, 6/4 Row DX coil Interlaced/Interwined multi circuit design with VRF ODU's 30HP with mixing box .
VRF Outdoor Units
Supply, installation, testing and commissioning of High COP VRV type condensing units (ODU) of minimum COP of Inverter Compressor to be as per the technical specifications. The outdoor unit shall have the multi-step of capacity control to meet load fluctuation and indoor unit individual control. Unit shall be equipped with an oil recovery system to ensure stable operation with long refrigerant piping. System suitable for Cooling with R-410A /407C. Outdoor condensing unit comprising of Hermetic Scroll compressor, Heat Exchanger, propeller / axial fans, refrigerant Circuit, filter driers, sight glass, liquid receivers, accumulators, Safety Devices, Oil Recovery System with complete charge of gas and recommended oil. The outdoor unit shall be fully capable of working in conjunction with multiple indoor units of various capacities as per list of IDUs mentioned in the equipment summary. including office area Refnut joints , outdoor units to be mounted on MS platform with suitable Vibration Isolation pads to avoid vibrations. All the supports and angle base frame structure to be duly black painted with synthetic epoxy paint. This includes required integration kits to inter conncet copper & communication with the AHUs mentioned above
Makes: Daikin//Mistibhushi/Toshiba
Indoor Units
I )Supply, testing & commisioning of Cassette type indoor units comprisisng with pre-filter,fan section with low noise fan multispeed motor, coil section with DX coil, outer cabinet, decorative panel for cassette units,drain water lift-up meachanism, insulation, pipe connections including card less remote , fresh air intake etc. of various capacities as per specifications and drawings.Including Lifting,Shifting, Positioning & Commissioning of the Units
a)2.5TR Casstee Unit
II)Supply of Hi wall split type indoor units comprisisng with pre-filter,fan section with low noise fan multispeed motor, coil section with DX coil, outer cabient, insulation, pipe connections including card less remote etc. of various capacities as per specifications and drawings.
a)1.0 TR Hi wall Split unit
b)1.5 TR Hi wall Split unit
c)2.0 TR Hi wall Split unit
Supply, installation, testing and commissioning of Flange type, Flame proof FLP duct heaters with Mineral Filled AISI SS304/SS321 Sheathed Tubular Heater with GI Helical fins, Tube dia 8.2mm min and Helical Finn dia 25mm min,enclosed in the frame, FLP Terminal box etc,Nickel Chromium Inner Element, Silicon Sealing to Restrict Moisture pickup,Silver brazed mounting plate etc, and heters shall be controlled with PID thyrestor controller based on the humidstat. And this should have saftey thermostat and cutouts & air stat etc all safety controles. The capacities as follows and sizes of the heaters shall be as per the duct sizes and approved drawing.
a) 12 kW Capacity
Supply, Installation, Testing and Commissioning of Hard copper REFRIGERANT PIPING including required refnet Joints of 19swg various sizes with necessary supports, fittings, interconnecting the liquid and suction lines between the aircooled outdoor units and the indoor units. The piping shall be carried out of Hard drawn copper pipes of type 'K with soldered / brazed socket fittings. Isolating valves shall be provided to isolate each compressor, strainers, sight glass and any other component requiring proper operation and maintenance. Both the suction and liquid lines shall be insulated with 19mm thick closed cell insulation of density 70-80 Kg/m3 for above 25mm dia , 13mm thick for pipes below 25mm dia . The insulation finished with treated woven glass fiber reinforced covering and covered with 26G AL cladding for exposed Piping and including making required holes in the wall and re finishing and water tight of holes after laying holes as per the specifications and approved drawings.
iii) 19.1 mm
vii)34.93 mm
viii)41.3 mm
Supply, Installation, Testing and Commissioning of Hard copper REFRIGERANT PIPING including required refnet Joints of 16swg various sizes with necessary supports, fittings, interconnecting the liquid and suction lines between the aircooled outdoor units and the indoor units. The piping shall be carried out of Hard drawn copper pipes of type 'K with soldered / brazed socket fittings. Isolating valves shall be provided to isolate each compressor, strainers, sight glass and any other component requiring proper operation and maintenance. Both the suction and liquid lines shall be insulated with 19mm thick closed cell insulation density 70-80Kg/m3 for above 25mm dia , 13mm thick for pipes below 25mm dia . The insulation finished with treated woven glass fiber reinforced covering for inside Piping and including making required holes in the wall and re finishing and water tight of holes after laying holes as per the specifications and approved drawings.
iii) 12.7mm
vii)25.4 mm
viii)28.6 mm
Supply & Installation PVC drain piping with suitable supports as required & insulated with 6mm thick Nitrile rubber insulation.
Supply, Installation, Testing and Commissioning of CONTROL CABLING of 2C x 1.5 sq.mm flexable copper cable for communication between indoor and outdoor units to be suitably laid in 19 mm PVC conduit as per site requirement.
Supply, Installation, Testing and Commissioning of REMOTE Centralized Controller cabling of 2C x 1 Sq.mm. flexable copper cable to be suitably laid in 19mm PVC conduit as per site requirement.
Supply, Installation, Testing and Commissioning of CONTROL CABLING of 3C x 1.5 sq.mm flexable copper cable for communication between indoor and outdoor units to be suitably laid in 19 mm PVC conduit as per site requirement.
Supply , erection , testing of Factory fabricated GI ducting using class VIII sheets / coil, galvanised hardware & supports, silicon sealant at all joints, Angle iron angle flanges for all the joints, bracing angles where ever required and minimum 5mm thick neoprene rubber gasket
a) 24 Gauge
b) 22 Gauge
c) 20 Gauge
Supply, Fixing, Testing and commissioning of Extruded Aluminum powder coated Continuous Grills & Discreet Grills as per specifications including required wooden frame as per the site conditions.
Supply, Fixing, Testing and commissioning of Extruded Aluminium powder coated removable core type 4 way Diffusers as per specifications
Supply, Fixing, Testing and Commissioning of
a) Duct Dampers
b) Fusible link GI Fire dampers with fusible links
c)Supply, Installation of Aluminum powder coated collar dampers for supply and return air diffusers/ Grills
Supply and fixing of Aluminium powder coated fresh air Louvers with bird screen wire mesh & damper, including standard fixing accessories etc., complete and sizes as per drawing.
Supply and fixing of thermal insulation with 19mm thick Class"O" Al foil faced Nitrile rubber material density 40-60 Kg/cum with fixing accessories etc complete for Supply & Return Air ducting .
Supply and fixing of thermal insulation with 13mm thick Class"O" Al foil faced Nitrile rubber material density 40-60kg/cum with fixing accessories etc complete for Supply & Return Air ducting .
Supply and fixing of Acoustic Insulation with 10mm Open cell nitrile rubber material density 110 to 140 kg/cum for Ducting.
Supply, Installation, Testing and commissisioning of Factory Fabricated 25mm thick PUF panel plenum box with 0.6mm /0.6 mm pre coated / plain GI outer /inner skins as per the drawings at 500 FPM velocity as per site conditions
Supply, Fabrication and intsllation of MS Structural supports/angles for AC out door units / AHU's supporting etc with primer and anamel paint
ELECTRICAL PANEL
a) AHU PANEL
Incoming:
200A,35KA TP+NL MCCB Thermal magnetic Based Release With Indication Lamps-1 No
Metering Incomer :
Busbars :250 A TPN Aluminium Busbars. 1 set
Outgoings :
40A,300mA FP ELCB –6nos
32A,10KA 3P+NL MCB –3nos
16A, 10KA SP MCB –3nos
Starter for 5.5 KW DOL STARTER with 9-13A MPCB 415V and 5.5KW RATED VFD with Bypass Overload,Single phasing, Under voltage and overvoltage, phase reverse protection with necessary internal wiring. Starter should be compatible for BMS also with necessary inputs and outputs provisions, power and control wiring should be carried out as per IS standards- 2No (AHU- 2 nos)
2A 24V DC Power for SMPS –1Nos
Each outgoing with Indication lamps & 4 nos of NO/NC Contractors
b) Isolator Box
Supply, installation, Testing and Commissioning of 1 nos 40A, 4P, 300ma ELCB in enclosed a weather proof box wall mounted suitable for out door application with class protection not less than IP - 65 .and incoming & outgoing cable bottom Entry with sutable Weather Proof glands.
c) ON/OFF Push button Station
Supply, installation, Testing and Commissioning of on /off push button station with enclosure , all Control wiring & termination connectionsas required as per the site condition , fixing arrangement etc complete.,
MV CABLES:
Supply, laying and commissioning of following size 1.1KVgrade PVC insulated armoured Aluminium/Copper conductor cable, neatly dressed & clamped to existing cable trays/Trench.
a)3.5CX70 SQMM XLPE Al armoured cable
b)4CX16 SQMM PVC CU.AR.CABLE
c)4CX6 SQMM PVC CU.AR.CABLE
MV CABLE TERMINATIONS:
Providing Indoor ordinary end terminations for the cable specified above with double compression type steel gland,Bi-metallic lugs using crimping tool,Insulation tape,Identification tags etc., including end termination and Earthing of Gland with 8SWG 'GI Wire
a)3.5CX70 SQMM XLPE Al armoured cable
b)4CX16 SQMM PVC CU.AR.CABLE
c)4CX6 SQMM PVC CU.AR.CABLE
d)4CX4 SQMM PVC CU.AR.CABLE
CABLE TRAY
Supply and Installation of following size 2mm thick GI Perforated type cable tray with top covering GI sheet, coupler plates, bends, elbows, tees etc as required. The scope also includes suitable cable tray supports arrangements on walls/Ceiling/Trench with M.S.Structrual steel / Threaded rods, anchor bolts & nuts wherever required as per site conditions.
a) 100 mm wide x 50 mm deep x 2 mm thick
b) 200 mm wide x 50 mm deep x 2 mm thick
EARTHING
a) Providing G.I. Earth station, with 40mm dia 2500mm long GI pipe including construction of brick pedestal, providing meshed funnel,CI cover and other civil Engineering works,spreading a homogenous mixture of salt, charcoal aroundthe pipe etc, completely as per IS 3043, 1987 or latest revision.
b) Supply and laying of following earth strips/ conductors.
i) Supply and fixing of 50 x 6 MM GI Flat
ii) Supply and fixing of 25 x 6 MM GI Flat
iii) Supply and fixing of 8 swg GI wire
SUBHEAD- XVIII : INTERNAL ELECTRIFICATION:
Lights Points
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 5/6 A modular switch, connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the modular plate switch box including connections, modular plate etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.(AC sockets)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Light/Fan Fixtures
Supply of the following LED Light Fixtures with electronic driver , heat dissipating element including necessary accessories etc., complete on wall/ Ceiling / suspended from ceiling/ recess including all fixing accesssories such as leads,Teak wood round block, downrods, MS clamps, nuts, GI chain and bolts etc complete as required.
Supply of 28W high efficient LED 595mmX595mm recessed light fixture, CRCA Housing, Luminaire system efficacy >125lm/W, System Lumens 3600lm, IP20 protection, IK02, surge protection 4 kV, driver efficiency >85%, power factor > 0.95, THD ≤10%,LED used to be SMD LED, MacAdam<5 LED Type for better color matching & to avoid color shift with LED binning as per ANSI standard,colour rendering index CRI >80, temperature range 0 to 45 degree centigrade, CCT: 6500K, Lifetime of LED 50K hours @L70 B50 @45 degree ambient, photo biological safety report as per IEC 62471, Voltage range 140-270V AC, Ripple<5%, Electricals insulatuation Class-1, EMI/EMC Complaince similar to Philips Cat No: Full Glow RC380B LED36S / Equivalent Make of Wipro.
Supply of 11W high efficient LED dwonlighter, PDC Housing, Luminaire system efficacy 110lm/W, System Lumens 1200lm, IP20 protection, IK02, surge protection 2.5 kV, driver efficiency >85%, power factor > 0.95, THD ≤10%, MacAdam<5 LED Type for better color matching & to avoid color shift with LED binning as per ANSI standard,colour rendering index CRI >80, temperature range 0 to 45 degree centigrade, CCT: 6500K, Lifetime of LED 50K hours @L70 B50 @45 degree ambient, photo biological safety report as per IEC 62471, Voltage range 130-320V AC, EMI/EMC Complaince similar to Philips Cat NoDN296B LED12S / Equivalent Make of Wipro.
Supply of 16W high efficient LED batten, CRCA Housing, Luminaire system efficacy 125lm/W, System Lumens 2000lm, IP20 protection, IK02, surge protection 4 kV, driver efficiency >85%, power factor > 0.95, THD ≤10%, MacAdam<5 LED Type for better color matching & to avoid color shift with LED binning as per ANSI standard,colour rendering index CRI >80, temperature range 0 to 45 degree centigrade, CCT: 6500K, Lifetime of LED 50K hours @L70 B50 @45 degree ambient, photo biological safety report as per IEC 62471, Voltage range 140-270V AC, Ripple<5%, Electricals insulatuation Class-1, EMI/EMC Complaince:BN308 LED20S L120 / Equivalent Make of Wipro.
Supply of 70W high efficient LED High bay light fixture, PDC LM6 Housing, Luminaire system efficacy 150lm/W, System Lumens 10000lm, IP65 protection, IK08, surge protection 4 kV, driver efficiency >90%, power factor > 0.95, THD ≤10%,LED used to be SMD LED, MacAdam<5 LED Type for better color matching & to avoid color shift with LED binning as per ANSI standard,colour rendering index CRI >80, temperature range -10 to 55 degree centigrade, CCT: 5700K, Lifetime of LED 50K hours @L70 B50 @45 degree ambient, photo biological safety report as per IEC 62471, Voltage range 120-270V AC, Electricals insulatuation Class-1 Philips Cat No: BY515,Equivalent Make of Wipro.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Ceiling Fans & Wall Mounted Fans
Supply of 1200 mm sweep 5star rated Ceiling fan with standard down rod, all accessories Electrical connections. Including fixing materials as required.
Supply of 600 mm sweep 5star rated Wall Mounted Air circualted fan with support rods all accessories Electrical connections. Including fixing materials as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Exhaust Fans
Supply of heavy duty Exhaust fans with Non Metallic blades following size sweep with gravity louvres shutters Exhaust fans with Metallic blades of following.
300mm Sweep 1400rpm
Supply of Exhaust fans with PVC blades following size sweep with gravity louvres shutters Exhaust fans of following
200mm Sweep 900rpm
Installation of exhaust fan in the existing opening, including making good the damage,connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
4 way (4 +12), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current breaker with Overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 A, Four Pole, RCBO, 30mA.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5A - 32A, Single pole, MCB, 10kA
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
8 way, Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, RCBO having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 A DP RCBO, 30mA
Supplying,installation,testing an d commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.d.
400 mm width X 50 mm depth X 2.0 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
SUBHEAD- XIX : POWER WIRING
Providing and fixing Cubical panel borad with following rating and breaking capacity of MCCB with TMD based release and No. and 1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
125 A, 25 KA,TPMCCB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
8 way (4 + 24), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current breaker with Overload (RCBO), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 A, Four Pole, RCBO, 100mA.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5A - 32A, Single pole, MCB, 10kA
Supplying and fixing 63 A rating, 240 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63A, Single pole, MCB, 10kA
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
SUBHEAD- XX : UPS WIRING
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
8 way (4 + 24), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current breaker with Overload (RCBO), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 A, Four Pole, RCBO, 100mA.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5A - 32A, Single pole, MCB, 10kA
Supplying and fixing 63 A rating, 240 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63A, Single pole, MCB, 10kA
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 16 sq. mm earth wire
SUBHEAD-XXI : SHOP ELECTRICALS
ELCTRICAL PANEL
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/Galvanised steel enclosure for main frame and 1.6mm thick partitions and after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.The panel shall be got fabricated from manufacturers as per CPRI Approved. Indoor panels shall have IP-4X degree of protection and outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
MAIN PANEL
INCOMER
ACB, with Electrically Draw out with 800Amps, 50kA, FP,. - 1 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 1No.
0 - 800A Digital Ammeter- 1 No.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 1 No.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 1000A with 50 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
OUTGOINGS
200A, 35KA FP MCCB (Microprocesssor release)- 1No
125A, 25KA FP MCCB (Thermal Magnetic release)- 15Nos
63A, 16KA FP MCCB (Thermal Magnetic release)- 3Nos
40A, 16KA FP MCCB (Thermal Magnetic release)- 3Nos
40A, 10KA FP MCB - 2Nos
32A, 25KA FP MCCB with TVSS - 1set
1 Lot of control wiring.1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
UPS PANEL
INCOMER
MCCB, with Microprocesssor based release 125Amps, 36kA, FP,. - 1 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 1No.
0 - 125A Digital Ammeter- 1 No.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 1 No.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 160A with 36 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
OUTGOINGS
63A, 16KA FP MCCB(Thermal Magnetic release)- 2Nos
40A, 16KA FP MCCB (Thermal Magnetic release)- 2Nos
40A, 10KA FP MCB - 1Nos
32A, 25KA FP MCCB with TVSS - 1set
1 Lot of control wiring.1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
Providing and fixing Cubical panel borad with following rating and breaking capacity of MCCB/ACB withTMD based release - 1 No. and 1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
125A, 25 KA,FPMCCB
Supply of following size 1.1KVgrade XLPE insulated armoured aluminium/Copper conductor underground cable, The cable shall conform to IS 7098 Part-1.
3.5C X 300 Sq.mm Aluminium
3.5C X 240 Sq.mm Aluminium
3.5C X 70 Sq.mm Aluminium
4C X 16 Sq.mm copper
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE/ copper conductor cable of 1.1 kV grade as required.
3½ X 300 sq. mm (70 mm)
3½ X 240 sq. mm (62 mm)
3½ X 70 sq. mm (38 mm)
4 X 16 sq. mm (28mm)
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
Providing and fixing 25 mm X 3 mm G.I. strip on Cable tray recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm Copper strip on surface or in recess for connections etc. as required.
SUBHEAD-XXII : TELEPHONE/LAN CONDUTING
Supply and laying of 25mm dia. Medium class PVC conduit concealed in wall/ ceiling/floor including all accessories such as junction boxes, conduit bends, etc completed as required for Telephone & Lan etc.,
Supply and laying of 25mm dia. Medium class PVC conduit With GI WIRE concealed in wall/ ceiling/floor including all accessories such as junction boxes, conduit bends, etc completed as required for Telephone & Lan etc.,
Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and plug in type telephone socket .
Supply and installation of the following Krone connectors in junction box complete as required.
a)20 pair
Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wire conforming to DOT Specification
Supply and fixing of LAN outlet (RJ48) with anodised GI box with front plate and plug in type LAN socket .
Supply,Installation & Testing of 24-Port Fast Ethernet managed L2 switch
Supply and laying of CAT6 UTP Unarmoured cable conforming to latest Standards.
SUB HEAD-XXIII : SPECIAL EARTHING
Supply Installation, Testing & Commissioning of UL Listed Copper Bonded Steel Earth rod made of low carbon steel with min 250 micron of coating of 99.99% pure copper. A copper bonded rod shall have a 17.2 mm dia., and 10 ft. length. The rods shall be vertically installed as per approved drawing (depending on the site conditions). The earth rod shall be placed in an augured hole of dia 125mm and typically backfilled with an earth enhancement compound.The copper bonded earth rod shall comply the requirements of IEC 62561-2 and tested as per UL 467.
Supply & Installation of RoHS certified, eco-friendly, Earth Enhancing Compound, complying IEC 62561-7. The compound is available with non-hazardous characteristics and low resistivity value that shall be less than 0.12Ω-m, typically placed around the rod in an augured hole of dia. 125 mm. The earth enhancement compound shall be tested as per IEC 62561-7 from NABL accredited lab. An earth enhancement compound shall be a waterproof bag of 10Kg.
Supply Installation, Testing & Commissioning of 50 x 6 mm copper strip for earthing system to make connections with riser and equipment terminal as required.
Exothermic L Joint:- Provision of exothermic weld connecting copper strip of 50x6 mm. to copper strip of 50x6 mm. with Vertical Copper bonded steel Earth Rod of 17 mm dia.; including exothermic- L-type mould and accessories for weld connection conforms IEEE 837 with 400gms of Exothermic Weld Powder.
Exothermic T Joint:- Provision of exothermic weld connecting copper strip of 50x6 mm. to copper strip of 50x6 mm. with Vertical Copper bonded steel Earth Rod of 17 mm dia.; including exothermic- Tee-type mould and accessories for weld connection conforms IEEE 837 with 300gms of Exothermic Weld Powder.
Exothermic Straight Joint:- Provision of exothermic weld connecting copper strip of 50x6 mm. to copper strip of 50x6 mm. including exothermic- straight-type mould and accessories for weld connection conforms IEEE 837 with 400gms of Exothermic Weld Powder.
Exothermic L Joint:- Provision of exothermic weld connecting copper strip of 50x6 mm. to copper strip of 50x6 mm..; including exothermic mould and accessories for weld connection conforms IEEE 837 with 400gms of Exothermic Weld Powder.
Supplying and laying 65mm dia standred Length (As per Equipement Supplier)Electrode Capsule Filled with earth enhancing compound sealed at both ends and brazed lead for connection at one end Suitable for direct intallation at site at depth 2.5mtrs earth Enhanacement Compound at depth 2.0mtrs around electrode capsule brick chamber & CI Cover Complete with eco friendly maintenance Free Single pipe Earth Electrode Model GAL-802.5 Consist of 77mm dia 3.4mm thick, 2.5mtr Long with 40x10mm MS flat fixed at top as terminal top and bottom with MS flange the entrie construction processed with hot dip galvanization as per IS standard and all inner annualr space filled with highly conductive and non-corrosive nature crystalline material along with galaxy moisture booster backfilled compound 2x20kg bags will be supplied.
SUB HEAD-XXIV : LIGHTNING PROTECTION SYSTEM
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Supply and laying of following size strips including all necessary inter connections between earth station and equipment. supports for strips as applicable .
32 X 5mm Aluminium strip with DMC Insulated Supports
50 X5mm GI strip laid in ground
Supply and installation of vertical air termination with 40 mm dia copper hollow sphere with spikes, fixed on 1000mm length 25mm dia Copper tube including all fixing accessories..
Supply and installation of Test link fuse as required complete set
SUB HEAD-XXV : FIRE ALARM SYSTEM
Supply,Testing and commissioning of the following number of Loops Microprocessor based addressable type (EN / UL approved) Fire alarm control panel with Zonal Indications, supervised inputs, supervised and non-supervised outputs,Zener barriers, two way media converter / Signal booster for in / out network connectivity with OF cableand with battery Power pack as per specifications.
a) 1 - Loop
Supply installation, testing and commissioning of analog addressable type multi sensor (smoke/ Heat) photo electric detectors with base and LED indication lamp along with all fixing accessories.
Supply, installation, testing and commissioning of Single ended reflector type addressable Beam smoke detector with all required accessories etc., complete.
Supply installation, testing and commissioning of reponse indicators with LED indication lamp along with all fixing accessories.
Supply, Installation, Testing and commissioning of anologue addressable loop sounders along with all fixing accessories.
Supply, Installation, Testing and commissioning of fault isolators along with all fixing accessories.
Supply,Installation,Testing and commissioning of anologue addressable type monitor module along with all fixing accessories.
Supply,Installation,Testing and commissioning of addressable control module along with all fixing accessories.
Supply, Installation,Testing and commissioning of anologue addressable ordinary Manual call point with push type along with all fixing accessories.
Supply and laying of 25mm dia medium class FRLS PVC conduit concealed in wall /ceiling / above false ceiling including bends,elbows, junction boxes, saddles, spacers etc., and other material required for fixing complete as per requirement.
Supply,laying,testing of twisted pair 1.5sq mm shielded FR insulated copper conductor flexible wire in existing PVC conduit.
Supply, fixing and installation of fire exit signage's self illuminating light fixtures displaying exit with an arrow towards the exit door.
NIMMA NARAYAN ENGINEERS & CONTRACTORS
SREE LAKSHMI CONSTRUCTIONS
RMK Projects
SAI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .