| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.0 L+₹95,465 (3.41%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹31.9 L+₹3.9 L (14.0%)Rejected-Finance 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹33.3 L+₹5.3 L (18.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹33.8 L+₹5.8 L (20.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
6 May 2024, 6:00 pmClosed
Maj Ashwin Awadh
GE (W) Agra
ATTENDING DAY TO DAY COMPLAINTS OF WATER SUPPLY INCLUDING REPAIR AND REPLACEMENT OLD UNSV MISC ITEMS UNDER AGE E/M (W) OF GE (W) AGRA
2024_MES_649759_1
8012/1022/E8
Open Tender
Civil Works
Item Rate
330 days
GE (West) Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (West) Agra
₹98,000
7 Sept 2024
9 Apr 2024
8 May 2024
9 Apr 2024
6 May 2024
23 Apr 2024
Amount
Excavation in trenches in soft/loose soil, n. exc. 1.5 M wide and n.exc 1.5 M in depth, to required level and gradient for laying of pipe etc and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed.
Removing excavated materials (soft/loose soil) to a distance n.exc. 50 M and depositing where directed at a level n.exc. 1.5 M above the starting point complete all as specified and directed.
Taking up or down for 100 mm bore UNSV corroded steel tubing medium grade and connections complete all as specified & directed.
All as per item No-4 above but 80mm bore.
All as per item No-4 above but 50mm bore.
All as per item No-4 above but 40mm bore.
All as per item No-4 above but 25mm bore.
All as per item No-4 above but 20mm bore.
All as per item No-4 above but 15mm bore.
Refixing/relaying for the 100 mm bores old steel tubing in new or old position including new ISI GI fittings after cleaning by suitable chemical, roding, cutting to required length, screwing ends etc. as per site requirement complete including existing connection with required size of Tee or MS clamp with rubber bush all as specified and directed. Note: GI pipe retrieved from item No. 4 here-in-before shall be used after cleaning.
All as per item No-11 above but 80mm bore.Note: GI pipe retrieved from item No. 5 here-in-before shall be used after cleaning.
All as per item No-11 above but 50mm bore.Note: GI pipe retrieved from item No. 5 here-in-before shall be used after cleaning.
All as per item No-11 above but 40mm bore.Note: GI pipe retrieved from item No. 5 here-in-before shall be used after cleaning.
All as per item No-11 above but 25mm bore.Note: GI pipe retrieved from item No.6 here-in-before shall be used after cleaning.
All as per item No-11 above but 20mm bore.Note: GI pipe retrieved from item No. 7 here-in-before shall be used after cleaning.
All as per item No-11 above but 15mm bore.Note: GI pipe retrieved from item No. 8 here-in-before shall be used after cleaning.
Supply , laying and jointing for the 100 mm bore in trenches/on floor/wall, galvanized steel tubing medium grade including ISI marked GI fittings, including cutting to reducing length, screwing and connecting with existing line including fix existing connection with required size of Tee or MS clamp with rubber bush complete all as specified and directed.
All as per item No 18 above but 80 mm bore.
All as per item No-18 above but 50mm bore.
All as per item No-18 above but 40mm bore.
All as per item No-18 above but 25mm bore.
All as per item No-18 above but 20mm bore.
All as per item No-18 above but 15mm bore.
S & F in repair Gate valve 50 mm bore standard of Gun metal globe any colour high pressure, screwed for iron pipe complete all as specified and directed.
All as per item No 25 above but 40 mm bore.
All as per item No 25 above but 25 mm bore.
All as per item No 25 above but 20 mm bore.
All as per item No 25 above but 15 mm bore.
S & F in repair for repairs to leakage of GI medium grade pipe line 200 mm dia size including excavation earth work in any type of soil, cleaning joint and make joint leak free complete all as specified and directed.
All as per item No-30 above but 150 mm bore.
All as per item No-30 above but 100 mm bore.
All as per item No-30 above but 80 mm bore.
All as per item No-30 above but 50 mm bore.
All as per item No-30 above but 40 mm bore.
All as per item No-30 above but 25 mm bore.
All as per item No-30 above but 20 mm bore.
All as per item No-30 above but 15 mm bore.
S & F in for 200 mm x 200 mm size "D" joint made out of CI collar and rubber ring complete all as specified and directed.
All as per item No 39 above but 150 mm x 150 mm "D" Joint.
All as per item No. 39 above but 100 mm x 100mm "D" Joint.
All per item No. 39 above but 80 mm x 80 mm size "D" joint.
All per item No. 39 above but 50 mm x 50 mm size "D" joint.
S&F MS clamps for 150 mm (bore size 25mm) including nuts bolts and washers complete all specified and directed.
All as per item No 44 above but 80mm (bore size 25mm) Pipe.
All as per item No 44 above but 50mm (bore size 20mm) Pipe.
All as per item No 44 above but 40mm (bore size 15mm) Pipe.
M & L in repairs 80mm bore Cast Iron sluice valve both ends flanged PN-1.6 with iron wheel (ISI Marked including nuts, bolts, washer and 3 mm thick rubber insertion sheet complete all as specified and directed.
All as per item No- 48 above but of size 100mm bore
All as per item No- 48 above but of size 150mm bore
All as per item No- 48 above but of size 200mm bore
M & L in repairs 200mm bore Cast Iron Foot valve one ends flanged (ISI Marked including nuts, bolts, washer and 3 mm thick rubber insertion sheet complete all as specified and directed.
All as per item No-52 above but 100 mm bore.
M & L in repairs 80mm bore Cast Iron Non Return valve (NRV) both ends flanged PN-1.6 (ISI Marked including nuts, bolts, washer and 3 mm thick rubber insertion sheet complete all as specified and directed.
All as per item No- 54 above but of size 100mm bore
All as per item No- 54 above but of size 150mm bore
M&L for Mild steel, plain, black sheet 1.25mm thick in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required.
Supply, fabrication and fixing of MS channel/Angle'C' section etc conforming to GDE FE 410- W as hip and jack rafter, purlins,ladder ect where connected to common rafters and running rails fixed with other connecting plates ect including necessary welding, cutting etc and two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with old size sub class 'B' brick straight or curved on plan, exc. 6M mean radius in cement mortor 1:6 for repairing of valve pit/disturbed wall of well complete all as specified and directed.
RAJEEV CONSTRUCTION
M/S OM Enterprises
VARDMAN ENTERPRISES
Balaji Associates
rohan traders
M/s S.M. Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .