Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l-1₹2.2 LAccepted-AOC | l-1 | Accepted-AOC Tender accepted and reasonable quoted rate | |
| 2 | l-2₹2.7 L+₹49,580 (22.5%)Rejected-Finance 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | l-2 | Rejected-Finance Higher side quoted amount | |
| 3 | l-3₹3.0 L+₹81,660 (37.1%)Rejected-Finance | l-3 | Rejected-Finance Higher side quoted amount | |
| 4 | l-4₹6.8 L+₹4.6 L (207.9%)Rejected-Finance | l-4 | Rejected-Finance Higher side quoted amount |
Tender Value
₹4 L
EMD Value
₹8,000
Closing Date
1 Sept 2020, 6:00 pmClosed
AGE(I)Dalhousie
AGE(I)Dalhousie
Repair and Maintenance of Lighting Protection System along with Earthing and other E/M work at Bakloh and Dunera Cantt
2020_MES_369752_1
AGE(I)/D-27/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Bakloh
As per tender and NIT doc
8 documents required · 8 mandatory
₹300
AGE(I)Dalhousie
₹8,000
6 Oct 2020
17 Aug 2020
3 Sept 2020
17 Aug 2020
1 Sept 2020
17 Aug 2020
Amount
S&F in replacement of single pointed air termination aluminum rod 12mm dia, 300mm long to fix on wall/ roof/ pipes with suitable mild steel clamps, nuts, bolts and washers as required at site including taking out old unservicebel termination rod complete all as specified and directed.
Taking down unserviceable the existing aluminum/copper strip of any size and type from the ground/ equipment (roof/ down conductor) and removing from site and including making good wall/floor/roof by making necessary platering/riveting as originol credit to contractor complete all as specified and directed.
S&F in replacement Aluminium strip 25x3.15 mm with saddles and fixing screws etc with minimum two number saddles on and including PVC gutties in each one meter of lenth for roof/wall conductors above ground complete all as specified and directed.
All as per Srl item No. 3 here in before but except strip retrieved from item No. 2
Earthing complete in any type of soil hard(rocky soil) /soft with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.50 metres below ground level, connected to galvanised iron strip 25 X 3 mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 No's and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering, perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point including taking out existing unservicable earthing all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron strip 25mm X 3mm size and protection pipe of 40 mm bore galvanised iron light grade.
Earthing complete in any type of soil hard (rocky soil)/soft) with copper plate electrode 60 cms x 60 cms x 3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connected to copper strip 20 X 3 mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and copper strip protected by mild steel galvanised iron pipe, light grade, 25 mm bore including provision of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 No's and with 6 mm dia mild steel bar handle made to shape, galvanised iron medium grade 15 mm bore pipe for watering perforated at bottom 1.75 metres long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point including taking out existing unserviceable earthing all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long copper strip 20mm X 3 mm size and protection pipe of 25 mm bore galvanised iron light grade.
S&F in replacement of single pointed air termination copper rod 12mm dia, 300mm long to fix on wall/ roof/ pipes with copper strip, nuts, bolts and washers as required at site including taking out old unserviceabel termination rod complete all as specified and directed.
S&F in replacement copper strip 20x3.15 mm with saddles and fixing screws etc with minimum two number saddles on and including PVC gutties in each one meter of lenth for roof/wall conductors above ground complete all as specified and directed.
All as per Srl item No. 8 here in before but except copper strip retrieved from item No. 2
S&F in replacement test point terminal block made out of Gun metel or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete all as specifide and directer by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out in any type of soil soft/hard (rocky soil) complete all as specifed.
Removal of excavated material to be distance n.exc 50 metres and depositing where directed at a level n.exc 1.5 metres high from the starting point, all as specified.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified.
malghotra construction co
M/S KEWAL SONS
Vishav Karma Refrigeration and Electric Work
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .