Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹18.6 L+₹20,070 (1.09%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Not Being L1 Bidder | |
| 3 | L3₹19.9 L+₹1.4 L (7.81%)Rejected-Finance PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L3 | Rejected-Finance Not Being L1 Bidder | |
| 4 | L4₹21.7 L+₹3.3 L (17.9%)Rejected-Finance 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L4 | Rejected-Finance Not Being L1 Bidder |
| Sl No | Description | Qty | Unit | SINGH CONST CO L2 | DEV RAJ MAGOTRA L3 | m/s shanti trading company L4 | ARNABH ASSOCIATES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing Air terminations Single pointed aluminium rod 12mm dia and 300mm long with necessary fixing arrangements on roof including taking down of old rusted all as directed. | 100 | Each | 150 ₹15,000 | 150 ₹15,000 | 250 ₹25,000 | 75 ₹7,500 Lowest |
| 2.00 | Supply and fixing Air terminations Single pointed copper rod 12mm dia and 300mm long with necessary fixing arrangements on roof including taking down of old rusted all as directed. | 35 | Each | 250 ₹8,750 | 200 ₹7,000 | 300 ₹10,500 | 145 ₹5,075 Lowest |
| 3.00 | Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 nos 8mm dia 25 mm hexogonal head screw including taking down old rusted as specified and as directed. | 20 | Each | 300 ₹6,000 | 500 ₹10,000 | 500 ₹10,000 | 220 ₹4,400 Lowest |
| 4.00 | Supply and fixing rectangular PVC insulators for copper/aluminium/GI strip complete all as specified and directed. | 525 | Each | 35 ₹18,375 | 10 ₹5,250 | 10 ₹5,250 | 2 ₹1,050 Lowest |
| 5.00 | Supply and fixing solar water heater panel 100/200 LPD (Evacuated Tube Collector)servicing, cleaning, brazing, cutting, opening of glass etc with replacement of end caps & rubber cover complete all as specifed and directed by Engr-in-charge. | 2 | Each Job | 26,000 ₹52,000 | 2,500 ₹5,000 | 17,000 ₹34,000 | 1,250 ₹2,500 Lowest |
| 6.00 | Supply and fixing Heating element capacity 2/3 KW for Solar water heater 1000/500 LPD all as specified and as directed. | 61 | Each | 1,800 ₹1,09,800 | 600 ₹36,600 | 750 ₹45,750 | 510 ₹31,110 Lowest |
| 7.00 | Cleaning, servicing and maintenance of Solar Water Heater System of capacity as installed, comprising draining out water from system, dismantling and cleaning of storage tank internally to remove scale, sludge and sediment deposits, cleaning/descaling of solar collector tubes/panels, headers, pipelines and fittings using approved descaling chemicals, checking and cleaning of NRV, air vent, valves and strainers, replacement of minor consumables such as rubber washers, Teflon tape etc., re-fixing and re-commissioning complete system, testing for proper circulation, leakage and heating efficiency, including all labour, tools, tackles, staging/scaffolding, safety precautions and transportation complete all as specified and directed by Engineer-in-Charge. | 85 | Each Job | 1,000 ₹85,000 | 600 ₹51,000 | 400 ₹34,000 | 200 ₹17,000 Lowest |
| 8.00 | Supply and fixing solar flat plate collector complete all as specified and directed by Engr-in-charge. Make : Recold/Inter solar pvt Ltd | 30 | Each | 2,000 ₹60,000 Lowest | 12,500 ₹3,75,000 | 16,000 ₹4,80,000 | 8,500 ₹2,55,000 |
| 9.00 | S&F vent pipe using medium grade GI tubing 20mm dia fixed to wall/ceiling upto level not less than 15cm from OH tank top level including necessary fittings, fixtures, clamps, etc all as specified and as directed. | 350 | RM | 220 ₹77,000 | 205 ₹71,750 | 120 ₹42,000 Lowest | 150 ₹52,500 |
| 10.00 | S&F medium grade GI tubing 15 mm dia fixed to wall/ceiling including necessary fittings, fixtures, clamps, etc all as specified and as directed. | 250 | RM | 150 ₹37,500 | 160 ₹40,000 | 150 ₹37,500 | 120 ₹30,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
30 Jun 2026, 6:00 pmClosed
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
REPAIR AND MAINT OF EARTHING SOLAR HEATING APPLIANCES LIGHTNING PROTECTION AND ELECTRIC ENERGY METERS OF VARIOUS CENTRAL INSTITUTE AND BLDGS UNDER GE SOUTH UDHAMPUR
2026_MES_771255_1
GE/S(U)-61/2026-27
Open Tender
Electrical and Maintenance Works
Works
270 days
GE SOUTH UDHAMPUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹50,000
Yes
11 Aug 2026
10 Jun 2026
1 Jul 2026
10 Jun 2026
30 Jun 2026
24 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing Air terminations Single pointed aluminium rod 12mm dia and 300mm long with necessary fixing arrangements on roof including taking down of old rusted all as directed. | 100 | Each | - | - |
| 2 | Supply and fixing Air terminations Single pointed copper rod 12mm dia and 300mm long with necessary fixing arrangements on roof including taking down of old rusted all as directed. | 35 | Each | - | - |
| 3 | Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 nos 8mm dia 25 mm hexogonal head screw including taking down old rusted as specified and as directed. | 20 | Each | - | - |
| 4 | Supply and fixing rectangular PVC insulators for copper/aluminium/GI strip complete all as specified and directed. | 525 | Each | - | - |
| 5 | Supply and fixing solar water heater panel 100/200 LPD (Evacuated Tube Collector)servicing, cleaning, brazing, cutting, opening of glass etc with replacement of end caps & rubber cover complete all as specifed and directed by Engr-in-charge. | 2 | Each Job | - | - |
| 6 | Supply and fixing Heating element capacity 2/3 KW for Solar water heater 1000/500 LPD all as specified and as directed. | 61 | Each | - | - |
| 7 | Cleaning, servicing and maintenance of Solar Water Heater System of capacity as installed, comprising draining out water from system, dismantling and cleaning of storage tank internally to remove scale, sludge and sediment deposits, cleaning/descaling of solar collector tubes/panels, headers, pipelines and fittings using approved descaling chemicals, checking and cleaning of NRV, air vent, valves and strainers, replacement of minor consumables such as rubber washers, Teflon tape etc., re-fixing and re-commissioning complete system, testing for proper circulation, leakage and heating efficiency, including all labour, tools, tackles, staging/scaffolding, safety precautions and transportation complete all as specified and directed by Engineer-in-Charge. | 85 | Each Job | - | - |
| 8 | Supply and fixing solar flat plate collector complete all as specified and directed by Engr-in-charge. Make : Recold/Inter solar pvt Ltd | 30 | Each | - | - |
| 9 | S&F vent pipe using medium grade GI tubing 20mm dia fixed to wall/ceiling upto level not less than 15cm from OH tank top level including necessary fittings, fixtures, clamps, etc all as specified and as directed. | 350 | RM | - | - |
| 10 | S&F medium grade GI tubing 15 mm dia fixed to wall/ceiling including necessary fittings, fixtures, clamps, etc all as specified and as directed. | 250 | RM | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
TENDER61.pdf
Tender Documents • 0.85 MB
BOQ_863690.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .