GE KHADAKWASLA
GE KHADAKWASLA
REPAIR AND MAINT OF STREET LIGHTS AND SECURITY AND HIGH MAST LIGHTS ALLIED WORKS ZONE A AT NDA KHADAKWASLA
2025_MES_705343_1
8930/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE KHADAKWASLA
All as per tender documents
9 documents required · 9 mandatory
₹500
GE KHADAKWASLA
₹76,000
Yes
18 Jun 2025
24 Apr 2025
22 May 2025
24 Apr 2025
20 May 2025
8 May 2025
24 Apr 2025 - 8 May 2025
Amount
Repair / maintenance of street / security lights any type, flood lights, post top lanterns, gate ligt ,Garden light or any other external lights in its position fixed on pole /building structure or by taking down to ground, if required, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like electronic driver, connection wires/ cable, MCB etc including refixing the fitting to its original position (if taken down), including repair / maint of street light control timer & junction box all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour and allied expenses only. (ii) Cost of spares electronic driver, connection wire, MCB, timer contactor spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defective street light fittings and will submit the completion report on the same day before 21.30hrs to the JE E/M. (vii) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipments and clothings to his men and department shall not be responsible for any kind of mishap / accident / injury to his men. (iv) The contractor has to rectify the defects / repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him / his rep by the concerned JE E/M. In case the street light is not made functional for whatsoever reason within the specified time limit, an amount of Rs 150/- per such defective street light per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall carry out repair / maint work simultaneously for different zones / pocket / areas like :- (a) Offrs residential area D1, D2, D3, E3 including main road from Bombay stadium to peacock bay, road to LVGH & Kondhana. (v) Vehicle mounted hydraulic ladder shall be provided on contractor's request which will be measured separately under Schedule 'C'. (vi) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (viii The contractor shall maintain sufficient stock of spares / material required for repair / maint of street lights with the concerned JE E/M against the supply only items here-in-below. (ix) The details of street / security lights is enclosed as Appx A to Schedule A for general idea about the location and type of light fittings.
Taking down the existing light fittings on multi mounting brackets from 16/21 mtrs highmast pole by taking on ground repairs/ replacing the defective parts like electronic drivers connection wires and refixing the same to its original position all as directed by Engr-In-Charge. Note: (i) Cost of spares , electronic drivers,connection wires replaced against above mentioned item above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (ii) The defects / repair of the floodlight making them functional after handing over defective floodlights of highmast (iii) Maintaining proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every flood light and getting it authenticated. (iv) Safety of his men engaged for executing the work along with safety equipment and clothes for the men shall be maintained.
Supply only following street light spares of branded make as mentioned in the list of make enclosed with Particular specifications for replacement:- (a) Electronic driver suitable for 90watts LED security light fittings Make should be as per the Existing manufacturer.
(b)Electronic driver for 30/40/ 45 / 48 / 50/60 watts LED road way/Flood light/post top Make should be as per the Existing manufacturer
(c)Electronic driver for 400/300 watts flood lights Make should be as per the Existing manufacturer
(d)Electronic driver for 200 watts flood lights Make should be as per the Existing manufacturer
(e)Electronic driver for 150 watts flood lights Make should be as per the Existing manufacturer
(f) Electronic driver for 100 watts flood lights Make should be as per the Existing manufacturer
(g) MCB SP 230 volts B curve 6 amps.
(h) MCB DP 230 volts C curve 6 amps.
(j) MCB TPN 415 volts C curve 63 amps.
(k) MCB TPN 415 volts C curve 40 amps.
(l)Digital time switch, DIN type daily / weekly with 25 ON/OFF programmes , 16 amps 250 volts AC.
(m)Power contactor 16/18 amps 3 pole.
(n)PVC insulated Copper conductor FRLS grade three core cable 2.5 sqmm, ISI marked.
(o) PVC insulated aluminium conductor two core round cable 4 sqmm, ISI marked.
(p) PVC insulated aluminium conductor two core round cable 6 sqmm, ISI marked.
(q) MCCB 63 Amps 4 pole 415 V 16 KA.
M&L for straight through joint (epoxy) for PVC insulated and sheathed aluminium conductor under ground cable incl freud , thimbles, nut & bolts, washers etc and testing afterjointing for 10 sqmm to 25 sqmm 4 core, complete all as specified and directed
Supply & Laying, jointing & testing of UG LT cables XLPE insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ ducts/ along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed.
All as per item No 20 above but size 16 sqmm 4 core.
All as per item No 20 above but size 10sqmm 4 core.
All as per item No 20 above but size 6 sqmm 4 core.
All as per item No 20 above but size 4 sqmm 3 core.
Excavation in trenches in any type of soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed.
Returning, filiing in incl spreading, leveling watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested as specified.
Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified.
Supply and laying 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e coupler, Tee, elbow clamp for cable protection complete all as specified and directed
Supply and fix in replacement of junction box thermo plast (weather proof) IP 66, on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB DP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed by Engr-In-Charge Make Sintex Cat pat No GSJB-3020 or equivalent make as mentioned in list of makes in PS.
Supply and fix in replacement of junction box thermo plast (weather proof) IP 66, on flood light poles made out of thermoplastic of size 140mm x 140 mm x 95 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB SP 6 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and wahers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed by Engr-In-Charge Make Sintex Cat pat No GSJB-1414 or equivalent make as mentioned in list of makes in PS.
Supply and fix in replacement of Plexo Box IP 65 (weather proof), on Gate/Post top Latern/Bollard As per IEC 61439-3 Suitable for Flush Mounting and Surface Mounting With 100 A Copper Busbar for each phase With 2 Neutral bar, 2 Earthbar and Cable ties for Cable management Fully insulated busbar & shrouded Neutral bars With provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB's as outgoing for fixing the box on post complete with nuts, bolts and wahers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed by Engr-In-Charge Make Legrand Cat pat No 601932 or equivalent make as mentioned in list of makes in PS.
S&F in replacement MCB DB 02 way SPN (single door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including MCB SPN 06 Amp 230V, 50 HZ, complete all as specified and directed.
S&F in repair of GI pipe bracket of 40 mm dia 1.2mtr long bend to shape for street light fitting made out of 40 mm dia GI light grade pipe fixed on pole using new FI clamp including necessary new nut, bolt and washer complete all as specified and directed.
S&F in repairs GI tubing light grade 40 mm dia ISI marked appx 1 mtr to 1.5 mtr long with Flat Iron Base for mounting of Flood light with all fittings incl nut,bolt,washers suitable size all as specified and directed
S& F in replacement of GI tubing light grade 50 mm dia ISI marked for bollard light with all fittings laid in trenches and fixed pole by flat iron clamps, nut,bolt,washers suitable size complete all as specified and directed.
S& F in replacement of GI tubing light grade 80 mm dia ISI marked for bollard light with all fittings laid in trenches and fixed pole by flat iron clamps, nut,bolt,washers suitable size complete all as specified and directed.
Labour for trimming / pruning tree branches overhanging or interfering or obstructing electrical pole or street lights complete all as directed in such a way that the clearance between Street light pole and tree branches should not be less than 1.5 mtrs around the Pole/Fitting complete all as specified and directed.
Material and labour for Tarmac bituminised road cutting by using suitable hydraulic road cutter for a width not exceeding 300 mm and depth 600 mm for laying of 80 MM medium grade GI pipe incl refilling and making good with Tarmac/ PCC duly matching with the existing surface complete all as specified and directed. Note: 1. Quoted rate shall be incl of 80 MM Gi pipe medium grade 2. Quoted rate shall deemed to incl the cost of making good the disturbed surface.
Suply & fixing in replacement of 30 watt LED flood light luminaire Warm white/white in colour with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 complete all as specified and directed
Suply & fixing in replacement of 50 watt LED flood light luminaire Warm white/white in colour with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 complete all as specified and directed
S & F in replacement of 100 watts flood light Warm white/white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed
S & F in replacement of 150 watts flood light Warm white /White in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed
S & F in replacement of 200 watts flood light Warm white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed
Suply & fixing in replacement of 300 watt LED flood light luminaire with separate driver assemble box with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66, with suitable Mounting structure as per site requirement complete all as specified and directed Make Havells- Cat No JETAVALOURFL300WLED757MODNBLTG or equivalent make as mentioned in list of makes in PS.
Supply and Fix in replacement integral LED aviation light comprising housing with polycarbonate enclosure, aviation light is to be fixed on highmast light frame complete all as specified and directed. Make: Bajaj Catpart No: BGAV302LED or equivalent make as mentioned in list of makes in PS.
Supply and Fix in replacemen LED 90watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixing to pole/wall with necessary nut, bolts and washers complete all as specified and directed.
Supply and Fix in replacemen LED 48/50 watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed.
Supply and Fixing in replacement outdoor gate light with 9W LED Bulb WW B22 with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new gate light as per site requirement and fixing arrangements complete all as specified and directed Make Luker Catpart No: LGL102B or equivalent make as mentioned in list of makes in PS.
Supply and Fixing in replacement outdoor gate light with 9W LED Bulb E 27 with Base with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new gate light as per site requirement and fixing arrangements complete all as specified and directed Make Luker Catpart No: LGLA2E27 BK or equivalent make as mentioned in list of makes in PS.
Supply and Fixing in replacement outdoor Spike light 3 W LED with Base with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC for new gate light as per site requirement and fixing arrangements complete all as specified and directed Make Luker Catpart No: LSSPK3 TR or equivalent make as mentioned in list of makes in PS.
Supply and Fix in replacement integral 18/20Watt LED post top lantern black/ copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover and accessorieson on existing GI Pipe of diameter complete all as specified and directed.
Supply & fix in replacement 40 watt LED post top made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection complete all as specified and directed.
Supply and Fixing 1x18 watt WW (3000K) LED bollard Integral decorative LED bollard with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC (1:2:4) type B1 for new bollard as per site requirement and fixing arrangements complete all as specified and directed Make : Luker Catpart No: LOBRD60 or equivalent in havells or philips Note: Quoated rate shall includes PCC work
Supply and Fixing 1x15/18 watt WW (3000K)withE 27 Holder and bulb, bollard Integral decorative LED bollard with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and make suitable PCC PCC (1:2:4) type B1 for new bollard as per site requirement and fixing arrangements all as directed Make Luker Catpart No: LBF012E27 BK or equivalent make as mentioned in list of makes in PS Note: Quoated rate shall includes PCC work
M&L for scrapping down and removing of old deteriorated paint from LT steel tubular poles of any height above ground level , preparing surface for painting , applying two coats of aluminium paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at site including making balck and white strips of 30 cms each upto 1.5 m above PCC muffs with black and white paint and marking of pole No 2 m above PCC muff, letter should not be longer than 6 cm height with 16 cm dia circle around the marked NO complete all as specified and directed
M&L for scrapping down and removing of old deteriorated paint from Post top lantern poles (RCC/GI) /(2 to 3 mtr) height above ground level , preparing surface for painting , applying two coats of black paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at site complete all as specified and directed
M&L PCC 1:3:6 type C-2 ( using 40 mm size graded stone aggregates) Cement concrete in foundations, filling and mass concrete complete all as specifed and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm size graded stone aggregate) as in coping of pole sand including formed work and demolition of existing coping complete all as specifed and directed .
M&L for PCC 1:4:8 type D-2 (using 40 mm size graded stone aggregates) Cement concrete in foundations, filling and mass concrete complete all as specifed and directed.
S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, 300mmX40mmX5mm(thickness) electrolytic grade of adequate rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with 4. RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 25mmx25mmx3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted on wall (at Sudan Dome)and suitable fixing arranement as per site requirement. The overall size of the Busbar panel shall be 350mmx200mmx400mm (LxBxH).including PCC 1:3:6 all as specified and directed.
Dismantling/ taking down the pole upto 16/21 metre height of high mast light by engaging suitable crane and repairing by replacing the unserviceable top pully of pole and other part such as winch motor, steel wire, power cable and servicing ,toping of oil and greasing the gear wheel assembly and hoisting, refixing and connecting up complete all as specified and directed . Note : a) The repair of light fittings and light fitting spares are measured and paid separately. b) Spares such as steel wire, power cable etc will be measured and paid separately under respective items. c) The entire work shall be carried out with well experienced professionals who undertake the high mast poles dismantling /repair works. d) Minor spares such as screws, bolt/nuts, grease etc shall provided by the contractor without any extra cost over and above the quoted rate.
Supply only stainless steel rope twisted of size10mm/6 mm dia with necessary connections proper binding on both sides from bottom drum mast top connecting hook complete all as specified and directed
Supply only gear box oil of grade EP 90/140 in standard packed/sealed container including drain out old gear box and filling up new gear box oil complete all as specified and directed.
Disconnecting electric connection and taking down carefully Fractional motor from highmast housing of any type and capacity as described below: -removing the burnt winding of motor rewinding with super enameled copper winding wire of suitable gauge or of matching size to the exisiting wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and refixing to original position all as directed by Engineer-in-charge.
M&L for Provision of protective cover of 1.20 mtr high and suitable size & shape, made out of plain mild steel wire 3.15mm dia, galvanised class 3, in protection for Bollard light fitting and including necessary fixing arrengements to prevent th light fitting from any damage and theft complete all as specified and directed
Supply and installation of the Outdoor LED strips 8W/220V along with all necessary accessories for a complete and functional installation. Accessories shall include, but are not limited to, compatible aluminum profiles, diffusers, power supplies, controllers,End cap, Drivers , wiring, connectors, and any required mounting hardware. The system shall be designed for outdoor use, meeting or exceeding the required IP 65 rating for the specified environment. This provision also includes installation, testing, commissioning mounting on the ceiling/wall/piller as reqd at the site including taking down of existing u/s complete all as specified and directed
S&F in Hanging LED Downlight lights with LED Bulb 12 W WW E 27 with Base with polycarbonate diffuser all as specified and directed. Make: Luker cat part no. LHLA7ME27 BK or equivalent make as mentioned in list of makes in PS.
Supply & fix in replacement of Hanging LED Downlight lights with LED Bulb 9 W WW E 27 with Base with polycarbonate diffuser all as specified and directed. Make: Luker cat part no. LHL402E or equivalent make as mentioned in list of makes in PS.
Supply & fix in replacement of 1x3watt LED WW outdoor wall light, made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 54 protection complete all as specified and directed. Make : Luker Product code LODARCS-3D or equivalent make as mentioned in list of makes in PS.
Supply & fix in replacement of 2x3watt LED WW outdoor wall light, made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 54 protection complete all as specified and directed. Make : Luker Product code LODARCD-6D or equivalent make as mentioned in list of makes in PS.
Supply and fix 5 W WW LED Solar garden light of lithium ferrous 3.7v 5200mAH battery, automatic on/off using LED sensor IP 65 Protection aluminium body Fixed on and including light post of suitable length and size duly grouted to ground inluding necessary PCC (1:2:4) type B1 work all as specified and directed . Make : Luker Catpart No. LBRSOL600 or equivalent make as mentioned in list of makes in PS.
Supply and fix 30 W LED Solar street light of lithium ferrous 3.7v 5200mAH battery, automatic on/off using LED sensor IP 65 Protection aluminium body Fixed on and including street light bracket of suitable length and size duly all as specified and directed . Make : Luker Catpart No. LBRSOL600 or equivalent make as mentioned in list of makes in PS.
GANGA ENTERPRISES (BID ID -3296125)
Tejas Enterprises (BID ID -3293964)
DARSHAN ENTERPRISES (BID ID -3295936)
KESARI AND SONS (BID ID -3300003)
R. P. Suppliers and Construction Co. (BID ID -3301204)
Sparkh Electricals & Works (BID ID -3298064)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .