Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC | L1 | Accepted-AOC Found reasonable for acceptance | |
| 2 | L2₹20.9 L+₹2.4 L (13.0%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹21.9 L+₹3.4 L (18.6%)Rejected-Finance FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹23.7 L+₹5.2 L (28.0%)Rejected-Finance 364 4 FIRDAUS SHABANA MARKET NEW SABZI MANDI JK COLONY ROAD KANPUR 07 | KANPUR NAGAR | UTTAR PRADESH | 208001 | L4 | Rejected-Finance L1 being accepted |
Tender Value
₹22.1 L
Closing Date
24 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (P) Navy Mandovi
GE (P) Navy Mandovi Military Engineer Services INS Mandovi
As per tender documents
2021_MES_493536_2
8415/E8 GE (P) NAVY MANDOVI
Open Tender
Construction Works
Item Rate
180 days
Mandovi
As per tender documents
8 documents required · 8 mandatory
₹500
GE (P) Navy Mandovi
Exempted
3 Feb 2022
7 Jan 2022
26 Jan 2022
7 Jan 2022
24 Jan 2022
12 Jan 2022
7 Jan 2022 - 11 Jan 2022
60 days
Amount
BUILDING WORKS
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
M & L for providing 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
M & L for providing 4 mm thick asbestos cement plain building boards, fixed to timber framework with screws as in ceiling, flat complete all as specified and directed.
S & F hangers of 6mm dia, GI (upto 1200mm length) adjusting level, fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size and 60mm long and expansion hold fasteners 12.5mm dia and 40mm long complete all as specified and directed.
M & L for preparation of newly plastered ceiling surfaces and applying two coats of distemper oil emulsion, white or tinted, over a coat of alkali resistant primer complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
S & F second class hardwood, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each, with shutters (without taking off shutters from the frames) complete all as specified and directed.
S & F 40 mm thick second class hardwood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; fitted to chowkats complete all as specified and directed.
M & L for preparation of new wooden surfaces of any description exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M & L for providing cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate in lintels upto 1.5m clear span, cills, steps; plinth courses, string courses, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M & L for forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in CM 1:6 complete all as specified and directed.
S & F butt hinges of 100 mm size, medium weight, cold rolled mild steel complete all as specified and directed.
S & F aluminium anodised, barrel tower bolts of extruded section, 150 mm long complete all as specified and directed.
S & F mild steel pressed handles of 150 mm size, oval type, stove enamelled black complete all as specified and directed.
S & F mild steel sliding door bolts, 300 mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S & F 300 mm ordinary rat tail rod pattern springs, mild steel, including roller and roller plate complete all as specified and directed.
S & F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S & F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, of 150 mm overall length of cover plate; fixed to door shutter complete all as specified and directed.
S & F aluminum powder coated window/ ventilator shutter including frame, any type (sliding or open-able) and other similar work etc, fabricated, by using sections, including necessary arrangement to receive 4mm thick sheet glass or wire mesh with aluminium channel beading, stainless steel screws, rollers, maruti lock including the cost of rubber gasket / rubber beading, rollers, maruti lock etc, fixing frames complete all as specified and directed. Note: Weight of rubber gasket / beading rollers, maruti lock will not be measured with weight of aluminium shutter. Note: Sheet glass & wire mesh shall be measured and paid separately.
S & F powder coated aluminium grill of design code No. DG-007 of DURAL GRILL, 7.5 mm thick complete all as specified and directed.
S & F 4 mm thick sheet glass, ordinary quality and glazing with oil putty/ beading in squares exc 0.5 sq. m in each pane complete all as specified and directed.
S & F in repairs aluminium anodized alloy curtain rod, 19 mm dia, decorative type, including a pair of brackets for each window length complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store complete all as specified and directed. Note: Overall measurement along the centre line over fittings and accessories as fixed shall be taken.
S & F PVC (SWR) pipes of 110 mm dia bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F PVC (SWR) bends, any radius, 110 mm bore with access door complete all as specified and directed.
S & F PVC (SWR) junction single (single T) of 110 mm dia bore, equal or unequal, with acess door complete all as specified and directed.
M & L for providing 12 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws in cupboard shelves complete all as specified and directed.
S & F in repairs door closer, hydraulically regulated, designation No. 3, universal type, aluminium (die cast) body, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
Taking down cement plaster of any description on stone/ PCC block /brick wall/ top of chajja etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris to outside of INS Mandovi area including filling of open joints in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finished even & smooth with using extra cement complete all as specified and directed.
M & L for preparation of newly plastered wall surfaces, priming plastered and other surfaces with alkali resistant priming paint, applying 1 mm thick wall care putty and distempering with two coats of distemper oil emulsion, white or tinted, complete all as specified and directed.
M & L for rendering 15 mm (10+5) thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 in two layers i.e first layer 10 mm thick and 5mm thick outer layer mixed with WPC as per manufacturer's instruction and finished surfaces even and smooth without using extra cement complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cost of WPC
M & L for preparation of newly plastered wall surfaces and applying two coats of acrylic emulsion exterior paint over a coat of primer complete all as specified and directed.
M & L for rendering 5 mm thick in cement mortar 1:3 on fair faces of brick work or concrete ceiling surfaces and surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M & L for preperation of old plastered wall surfaces including washing down, rubbing down and stopping of distempered wall surfaces, applying 1 mm thick wall care putty wherever required and applying one coat of oil bound distemper complete all as specified and directed.
M & L for preparation of old plastered ceiling surfaces and applying one coat of white wash complete all as specified and directed.
M & L for preparation of old plastered external surfaces, wall facia, ceiling cornices etc by brooming, scrapping down dust particles, smoke soot, moulds, moss and efforescent salts etc, making surface smooth by applying ready mix putty where required and applying one coat of anti fungal acrylic emulsion exterior grade paint over a coat of primer complete all as specified and directed.
M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and removing debri to a distance exc 250 m and not exc 1000 m spread and levelled complete all as specified and directed.
M & L for screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M & L for glazed ceramic coloured tiles 350 x 250 x 7 mm/ 450 x 350 x 7mm thick, set and jointed in neat cement slurry on floors and pointed in white or colour cement to match complete all as specified and directed.
M & L for granite tile flooring using granite (of any type) tiles, 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed.
M & L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick, walls built in CM 1:6 complete all as specified and directed.
Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and directed.
M & L for providing 18 mm thick marine waterproof plywood, grade BWR, type BB, grade 2 quality, interior grade, commercial type, fixed with screws to timber framed work for kitchen cabinet, cupboard etc, ISI marked and conforming to IS 710 complete all as specified and directed.
M & L for providing 12 mm thick marine waterproof plywood, grade BWR, type BB, grade 2 quality, interior grade, commercial type, fixed with screws to timber framed work for kitchen cabinet, cupboard etc, ISI marked and conforming to IS 710 complete all as specified and directed.
M & L for proividing 1.00 mm thick decorative veneer, type I, of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
M & L for proividing 1.00 mm thick decorative laminate, type I, of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
S & F butt hings of 50 mm size, heavy weight, cold rolled mild steel complete all as specified and directed.
S & F ball catches with 8 mm dia steel ball and brass body and striking plate including letting in complete all as specified and directed.
S & F 100 mm long brass handles, cast type, polished bright, for cupboards/ cabinets complete all as specified and directed.
S & F wooden beading of size 1" x 6mm thick complete all as specified and directed.
S & F powder coated trolley channels, 20 inch long, including all necessary accessories complete all as specified and directed.
S & F venetian blinds, blinds made of approved fibre cloth, including powder coated aluminium sliding tracks of standard medium weight sections and ceramic rollers complete all as specified and directed.
S & F PVC profile, 9 mm thick and of approved design, fixing to walls with line and level including all connected accessories complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, including ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling built in cement mortar complete all as specified and directed.
M & L for precast cement concrete block masonry with solid blocks, exc 10 cm in width, of PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in CM 1:6 complete all as specified and directed.
INTERNAL ELECTRIFICATION
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc to match existing surface complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one light point or fan point controlled by one switch complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for 5 Amps switch socket combination on independent board complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
M & L for point wiring complete with 2.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 2.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one 6 pin 15 Amps socket outlet on independent/metal plug and socket complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
S & F in repairs ceiling rose, 2 to 3 terminal, PVC polycarbonated isolating body complete all as specified and directed.
S & F in repairs switch piano, 5 amp, single pole, one way, flush type, complete all as specified and directed.
S & F in repairs switch socket combination 2 in 1, 6 pin and 5/6 Amps, flush type complete all as specified and directed.
S & F in repairs switch socket combination 2 in 1, 6 pin and 15/16 Amps, flush type complete all as specified and directed.
S & F in repairs LED tube light fitting 1 X 20 watt, 220V AC decorative box type with driver and holder, including LED tube light, connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting duly mounted on PVC block with steel screw complete all as specified and directed.
S & F in repairs sheet metal enclosure for MCB's (D.B), double door, TPN 4 way, 415 Volts, with suitable rated busbar complete all as specified and directed.
S & F in repairs sheet metal enclosure for MCB's (D.B), double door, SPN 8 way, 240 Volts, with suitable rated bus bar, complete all as specified and directed.
S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, 'C' series, complete all as specified and directed.
M & L for submain wiring with 4 runs of 10 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 10 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including 25mm/ 32 mm dia PVC conduit concealed in wall with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: 4 runs of 10 Sqmm cable, one run of 10 Sqmm earth wire and one run of PVC conduit shall be measured as unit run.
S & F in repairs MCB TPN, 50 - 63 Amps, 415 Volts, 'C' series complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground, earth pit not less than 2.25 m below ground level, with top edge of plate not less than 1.5 m below ground level, connected to 4mm dia GI earth wire by means of bolts, nuts, check nuts and washers of galvanised steel including neccessary earthwork and excavation in any strata, PCC chamber in PCC 1:3:6 type C2, 20 mm dia light grade GI pipe for protection of earth strip and GI wire, chamber cover etc all as per electrical plate No. 3 of SSR Part-I including connections with earth testing point complete all as specified and directed. Note: On testing after completion if the desired earth resistance is not obtained, earthing shall be redone at no extra cost.
AIR CONDITIONING
Supply and install hi wall split type air conditioner unit, indoor/outdoor complete with cordless remote control unit and with in built air-ioniser, copper condensor and plasma filter for better indoor air quality with minimum BEE 5 star rating and EER 3.2 rated power range 220-240 volts and 1.5 ton capacity, including all accessories such as extra copper pipe, 3 core wire etc and making good disturbed surface as per existing finish complete all as specified and directed.
Supply and install hi wall split type air conditioner unit, indoor/outdoor complete with cordless remote control unit and with in built air-ioniser, copper condensor and plasma filter for better indoor air quality with minimum BEE 5 star rating and EER 3.2 rated power range 220-240 volts and 2.0 ton capacity, including all accessories such as extra copper pipe, 3 core wire etc and taking down old unsv fittings and depositing to MES store yard complete all as specified and directed.
S & F wall mounted type electronic voltage stabilizer suitable for split AC of upto 2.0 ton capacity complete all as specified and directed.
S & F sheet metal enclosure earth plug and socket, single pole and neutral with two pin including one single pole MCB 20 Amps 240 Volts complete all as specified and directed.
M & L for submain wiring with two runs of 4 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including 25mm/ 32 mm dia PVC conduit concealed in wall with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC conduit shall be measured as unit run.
EXTERNAL ELECTRIFICATION
Supplying, laying, jointing, testing and commissioning of LT XLPE insulated, armoured, heavy duty electric cables with multistranded aluminium conductor of 4 core, 35 Sqmm, shielded core type wrapped with tape screwed galvanized strip, suitable for earthed system for 1100V, AC 50 cycle including centre glands, lugs, jointing materials etc and taking out old unsv cables complete all as specified and directed. Note: Excavation, PCC, covers and protection shall be measured and paid separately under relevant items of this schedule.
Excavating in trenches, not exceeding 1.5 m wide and n exc 1.5 m in depth and getting out in soft disintegrated rock for laying and removing cables of any sizes complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick using excavated soft disintegrated rock complete all as specified and directed.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply and laying fine dry river sand for cable protection in trenches for cable protection complete all as specified and directed. Note : Punned thickness only will be measured & paid.
Supplying and laying un-reinforced precast concrete cable cover for cable protection, class LV, type I, flat, size 250mm x 150mm x 40mm, ISI marked complete all as specified and directed.
SHREE SAI LABOUR CONTRACT CO-OPERATIVE SOCIETY LTD
Ramesh Enterprises
kay pee construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .