Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2 201 KALAKANOOTHPATTI ADIYANTHU DINDIGUL 624 003 | DINDIGUL | TAMIL NADU | 624003 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹1.9 L
EMD Value
₹1,950
Closing Date
15 Mar 2023, 3:00 pmClosed
BDO, BP Panchayat Union Office Dindigul
BDO, BP Panchayat Union Office Dindigul
SIDS 2021-22 Package 4
2023_RDTN_289484_1
3080/2022/A10 SIDS 2021-22 Package 4
Open Tender
Civil Works
Works
270 days
School Building Repair
SIDS 2021-22 Package 4
4 documents required · 4 mandatory
₹0
₹1,950
Yes
Panchayat Union Office Dindigul
17 Mar 2023
18 Feb 2023
15 Mar 2023
18 Feb 2023
15 Mar 2023
18 Feb 2023
20 Feb 2023
Amount
Part 1: Repairs to Panchayat Union Elementary School Tiled Roof Building South Facing @ Malaipatty H/o Balakrishnapuram Estimate Amount Rs. 1.95 lakhs
Chipping and Roughening the damaged Cement concrete including cost and conveyance of all material to site and all labour charges etc,completed
Removing the existing mangalore Tiles over flat tiles with out roof timber including all labour charges etc., complete and carefully stacking the tiles for re-use., as per standard specification
Supply and delivery of New Magalore Tiles , Ceiling tiles and ridge tiles including cost and conveyance of all materials to site etc., complete.,
Mangolore Tiles
Ceiling Tiles
Ridge Tiles
Roofing with Best Mangalore tiles Over One course of celing tiles including all labour charges etc., (Using Old & Supplied Tiles)
Brick work in c.m 1:5 mix using country bricks including cost & conveyance of all materials to site and all labour charges etc., complete.
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Providing Granolithic pattern floor finish with c.c 1:2:4 mix using 10 to 12mm ISS metal including cost & conveyance of all materials to site and all labour charges etc., complete.
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). Old Surface
Painting two coats with ready mixed Plastic emulsion of first class quality paint and of approved colour over a priming coat including through scrapping clean removal of dirt etc. complete and including necessary plaster of paris, putty wherever required.
Painting Old Wood Work with one coat of best synthetic enamel paint of approved quality colour including ordinary scrapping and preparation of surface ( the colour and quality should be got approved by the executive engineer before use) the rate including cost of brushes, high scaffolding charges finishing neatly etc, complete complying with standard specification and as directed by the departmental officer
Painting two coats with black board paint including cost & conveyance of all materials to site and all labour charges etc., complete.
Wiring with 2 x 1.5 sq.m (22/0.3) PVC insulated unsheathed SC Cu. Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box in flush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light point/fan point(for electronic regulator) - S.D.No: 20
Wiring with 2 x 1.5 sq.m (22/0.3) PVC insulated unsheathed SC Cu. Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with 150 x 100 x 113 TW switch box for 5A 3pin non inter locking CS plug with painting of suitable colour with continuos earth wire connection of 14 SWG TC wire for open PVC plug - S.D.No: 36
Supply and fixing of 1200mm (48") AC ceiling fan with stepped electronic 300 W regulator with 1 meter down rod on the existing clamp. - S.D.no: 107
Supply and run of 2 of 1.50 sq.mm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V on 7/20 GI bearer wire for service connection mains. - S.D.No: 64
Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting - S.D.No: 88
Supply and fixing of 16 Amps DPIC Switch of 500V with fuse and neutral (Side Handle) on suitable TW Board, with earth connection only. - S.D.No: 142
Supply and fixing of TNEB meter Board suitable for 32A Single phase service connection with 32A fuse unit(500V) 32A neutral link and earth link (1"x1/8" Copper flat) on TW plank of size 375mmx300mmx19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit - SD No: 125
Repairs to Existing Demaged Country Wood Doors Etc, completed
Repairs to Existing Demaged Country Wood Window Etc, completed
Construction of Rainwater Harvesting structure arrangement with PVC Pipe and Pit
Provision for Name Board Painting and lettering Charges
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
MOHANAVALLI CONTRACTOR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .