| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹16,410
Closing Date
4 Jun 2020, 3:00 pmClosed
AGM (EM), FCI RO Punjab
FCI, Regional Office Punjab, Bay No. 34-38, Sec 31A, Chandigarh
Replacement of Old Air Conditioners in FCI Regional Office building, Chandigarh
2020_FCI_561106_1
EE/PB/02/2020
Open Tender
Electrical Works
Item Rate
20 days
FCI, R.O Punjab
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
GM FCI RO Punjab
₹16,410
27 Jul 2020
26 May 2020
5 Jun 2020
26 May 2020
4 Jun 2020
26 May 2020
Amount
S/I/T/C of split type AC 1.5 Ton, 5 Star rating with Inverter Technology. The AC shall be suitable for 230+/_ 10% Volts, 50 HZ Ac Supply. The Cost of as per manufactures Standard i.e for fixing on wall or floor/terrace as per site requirement complete to the entire satisfaction of Engineer . The AC EER not less than 3.55 supply with copper Condenser 1.5 Ton capacity of nominal cooling capacity 4275 killo calories/Hr./12000 BTU/Hr. with permissible variation of +/_10% Room discharge air flow 650 cfm indoor noise level not exceed 50db.refrigent 410A/R32. Make Voltas/Carrier/LG (incl. dismantling of old ACs)
S/I/T/C of window type AC 1.5 Ton, 5 Star rating with Inverter Technology. The AC shall be suitable for 230+/_ 10% Volts, 50 HZ Ac Supply. The Cost of as per manufactures Standard i.e for fixing on wall or in window as per site requirement complete to the entire satisfaction of Engineer . The AC EER not less than 3.55 supply with copper Condenser 1.5 Ton capacity of nominal cooling capacity 4275 killo calories/Hr./12000 BTU/Hr. with permissible variation of +/_10% Room discharge air flow 650 cfm indoor noise level not exceed 50db.refrigent 410A/R32..Make Voltas/Carrier/LG (Incl. dismantling of old ACs)
S/I/T/C of window type AC 1.0 Ton, 5 Star rating with Inverter Technology. The AC shall be suitable for 230+/_ 10% Volts, 50 HZ Ac Supply. The Cost of as permanufactures Standard i.e for fixing on wall or in window as per site requirement complete to the entire satisfaction of Engineer . The AC EER not less than 3.55 supply with copper Condenser 1.5 Ton capacity of nominal cooling capacity 4275 killo calories/Hr./12000 BTU/Hr. with permissible variation of +/_10% Room discharge air flow 650 cfm indoor noise level not exceed 50db.refrigent 410A/R32. Make Voltas/Carrier/LG (incl. dismantling of old ACs)
Providing and fixing of votage stabilizer of(3 stage) with MCB, TDR, Volt meter, ampere meter, copper winding input range 160 to 280 volts, nominal oputput-230 volts+/- 10% including cost of copper wire from stabilizer to AC unit and power pluge to stabilizer upto 6m each with M.S body of 22 gauge sheet (powder coated), complete in all respect. 4KVA of make V-Guard/Microtek
Providing and fixing of powder coated ready made heavy duty outdoor stand for split outdoor as per site requiremnet to the entire satisfaction of enginner incharge.
Less Credit for old dismantled 1.5 ton split AC
Less Credit for dismantled 1.0/1.5 Ton window AC
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .