Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹15.0 L+₹1.8 L (13.4%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹15.4 L+₹2.2 L (16.8%)Rejected-Finance | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical NO remark in WLR and not enlisted in category b i | |
| 5 | Rejected-Technical | - | Rejected-Technical DD not uploded |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
22 Jul 2021, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli BANGALORE-13
8559PROVISION OF CONSULTANCY FOR REPAIR OF EARTHING INFRASTRUCTURE AT AFS JALAHALLI UNDER AGE EM WEST OF GE M AF JALAHALLI BANGALORE
2021_MES_442429_2
8559E8
Open Tender
Electrical and Maintenance Works
Item Rate
121 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹29,000
24 Aug 2021
21 Jun 2021
24 Jul 2021
22 Jun 2021
22 Jul 2021
30 Jun 2021
22 Jun 2021 - 28 Jun 2021
Amount
Material and labour for detailed study and recommendation for carrying out Soil Resistivity Test in 4 (Four) Directions at various location within the 25 mtr radius complete all as specified in following general condition including misc works required for the soil resistivity test as per IS (Indian electricity rules) requirement. Note - General condition (i) Field Audit Team to be deployed at site duly observing the safety rules as prescribed as per testing regulations. (ii) Safety procedures and any other action / precaution such as health check up to be undertaken by the firm before commencing the work in the area. (iii) The detailed study/analysis and design reports of existing building earthing infrastracture shall be furnish in Auto Cadd formet and also recommend the quantity of earth electrode with connected accessories for required value of earth resistence as per AFO 24/19 and OEM specified values as per following details :- (a) Power Earthing (PS) - Less than 1 Ohm (b) Signal Earthing (SG) - Less than 1 Ohm (c) Equipment Earthing (EQ) - Less than 1 Ohm for AFNET Equipment room and Less than 3 OHM for L-2 Locations (d) Lightning Arrester (LA)- Less than 5 Ohms (e) Labour charge for disconnecting/Connecting of earth strip from / to the earth electrode and required any hardware such as bolts, nuts etc for breaking of concrete or any other civil required to drive the spike / probes during testing shall be includes quoted rates of items. (f) Study of existing building earthing infrastructure at AFS Jalahalli and remedial action to overcome deficiencies in accordance with following standard:- (i) BS -7430 clause 8.5 (ii) Indian standard code of practice for earthing IS : 3043-1987 (reaffirmed 2006) (iii) IS/IEC 62305-3 of 2010 IS: protection against lightning. (iv) IEEE 1100-2205 - IEEE recommended practices for powering and ground electronics equipment. Ohms (v) National building code of India 2016- Volume 2 part- 8 :- Building services section 2 electrical and allied installations. The quoted rates of items included all above including submission report in soft and hard copy in approved manner of Engr in charge
Material and labour for detailed study and recommendation for carrying out Soil Resistivity Test in 8(Eight) Directions at various location within the 25 mtr radius complete all as specified in following general condition including misc works required for the soil resistivity test as per IS (Indian electricity rules) requirement. Note - General condition (i) Field Audit Team to be deployed at site duly observing the safety rules as prescribed as per testing regulations. (ii) Safety procedures and any other action / precaution such as health check up to be undertaken by the firm before commencing the work in the area. (iii) The detailed study/analysis and design reports of existing building earthing infrastracture shall be furnish in Auto Cadd formet and also recommend the quantity of earth electrode with connected accessories for required value of earth resistence as per AFO 24/19 and OEM specified values as per following details :- (a) Power Earthing (PS) - Less than 1 Ohm (b) Signal Earthing (SG) - Less than 1 Ohm (c) Equipment Earthing (EQ) - Less than 1 Ohm for AFNET Equipment room and Less than 3 OHM for L-2 Locations (d) Lightning Arrester (LA)- Less than 5 Ohms (e) Labour charge for disconnecting/Connecting of earth strip from / to the earth electrode and required any hardware such as bolts, nuts etc for breaking of concrete or any other civil required to drive the spike / probes during testing shall be includes quoted rates of items. (f) Study of existing building earthing infrastructure at AFS Jalahalli and remedial action to overcome deficiencies in accordance with following standard:- (i) BS -7430 clause 8.5 (ii) Indian standard code of practice for earthing IS : 3043-1987 (reaffirmed 2006) (iii) IS/IEC 62305-3 of 2010 IS: protection against lightning. (iv) IEEE 1100-2205 - IEEE recommended practices for powering and ground electronics equipment. Ohms (v) National building code of India 2016- Volume 2 part- 8 :- Building services section 2 electrical and allied installations. The quoted rates of items included all above including submission report in soft and hard copy in approved manner of Engr in charge
M/S SRI BALAJI ENTERPRISES
Forge Engineering & Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .