Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_129540_1
e-NIT No.EDJ/57 of 2021-22 Dated 05-07-2021
Open Tender
Electrical Works
Item Rate
CAD Talab Tillo
please refer to NIT
2 documents required · 2 mandatory
₹0
Exempted
16 Jul 2021
5 Jul 2021
16 Jul 2021
6 Jul 2021
15 Jul 2021
6 Jul 2021
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in Existing surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
2 x 1.5 sq. mm
2 x 2.5 sq. mm
1x 4 sq mm
2x 4 sq mm
2 x 6 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.
1 x 1.5 sq. mm
Supplying and fixing of surface mounted 18/20 watt LED batten tube fiiting Almunium Housing 4 feet long including connections etc as required.
Supplying and fixing of ceiling fan of double ball bearing type with 2.25 mfd condenser and down rod upto 4' long on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire.
Supplying and fixing of following sizes exhaust fan with PVC blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.
300 mm sweep exhust fan ( with louvers)
Supplying and fixing 5 amps to 32 amps rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Single Pole and Neutral
Supplying and fixing following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SPN 63 Amp
SPN 63 Amp
TPN 40 Amp
TPN 63 Amp.
Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts,on surface/recess complete with tinned copper busbar, neutral bus bar, earth bar,din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolater)
4 way (4 + 12), Double door
6 way ( 4+18), (Double door)
8 way (4+24), (Double door)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make)
Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required.
5/6 amp switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying installation testing and commissioning of XLPE insulated and PVC sheathed / power cable of 1.1 KV grade of following size in ground/.cable tray as per site conditions as required.
150 sq. mm x 3.5 core Armoured.
35 sq. mm x 3.5 core Armoured.
Supply and fixing of following LED type Street lights including connections etc as required. Complete with G.I bracket.
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode shall be tested from CPRI. The earthing pit should be covered with PVC cover.
Providing and laying of 25 x 5 mm G.I strip from G.I rod upto the main panel.
MCCB- 250 Amp- 36 KA- FP ICU=ICS=100%
MCCB- 100 Amp- 30KA- FP ICU=ICS=100%
MCCB- 63 Amp- 25KA- FP ICU=ICS=100%
Aluminium Bus bar 500 amp 4 strip.
Aluminium Bus bar 200 amp 4 strip.
Change over switch 100 amp front operatable
TPN 63 Amp.
TPN 40 Amp.
K K CONSTRUCTION
R.K ELECTRICAL ENGINEERS
RAJAN KUMAR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .