Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC EMAMGANJ DARGAH SHAREEF BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC ok | |
| 2 | L2₹3.5 Cr+₹5.6 L (1.61%)Rejected-Finance 60 27 88 INDUSTRIAL COLONY MALKAPURAM MALKAPURAM VISAKHAPATNAM ANDHRA PRADESH 530011 UDYAM AP 10 0007668 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L2 | Rejected-Finance L2 | |
| 3 | L3₹3.6 Cr+₹10.9 L (3.16%)Rejected-Finance 1503 SECTOR 9 AMBALA CITY HARYANA | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Rajesh Construction Co L2 | Shiv Shakti Industries L1 | SATISH KUMAR GUPTA L3 |
|---|---|---|---|---|---|---|
| 1.00 | Providing and Fixing TOILET CUBICLE - Toilet Cubicle Made Of Heat, Bacteria, Water Chemical, Scratch, Impact and Anti Bacterial Resistant 12Mm Thick ,Solid Compact Laminate Panels Included Doors, Pilasters and Intermediate Panels.Toilet cubicle I Shape (Front Partition) with standard ,dimension of Upto1950mm height x 1200mm width x 1500mm ,depth which includes 550-600mm door size width.Doors 1,Vertical Pilaster 2,U / Door Channels and Top Rail :- SS 304 Grade as per plan,Foot Assembly :- Shoe Box SS 316 Grade 16,Door lock with indicator SS 304 Grade 8,Door Knob SS 304 Grade 8,Self Closing Gravity Hinges SS 304 Grade 24,Coat Hook SS 304 Grade 8,Screws SS 304 Grade as per plan.all work done as per directed by engineer in charge. | 35 | Each | 25,200 ₹8,82,000 | 25,000 ₹8,75,000 Lowest | 25,590 ₹8,95,650 |
| 2.00 | Main LT Panel: Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.
400A FP MCCB, 415 V, 50 Hz. : 2 Nos
400A 4P Contractor 415 V, 50Hz.: 2 Nos With Electro Mechanical Interlocking arrangment
Indication and digital metering
400TP plus N Aluminium sectionalised BUS suitable for 1.1 K V with a fault level with-stand: 20 KA for 1 second. The Earth Bus shall be of AL and run contInuously throughout the width of the panel.
Outgoing :
125A, 4Pole, 50 Hz, MCB : 1 Nos.
63 A, 4Pole, 50 Hz, MCB : 6 Nos.
40 A, 4Pole, 50 Hz, MCB : 4 Nos.
20 A, DPPole, 50 Hz, MCB : 3 No.
Indication lamps (RYB) with control MCB - 03 Sets
Danger notice plate Make : As listed in UHBVNL | 2 | Nos. | 1,47,000 ₹2,94,000 | 1,42,000 ₹2,84,000 Lowest | 1,46,032 ₹2,92,064 |
| 3.00 | Main LT Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.
125A FP MCCB, 415 V, 50 Hz. : 2 Nos
125A 4P Contractor 415 V, 50Hz.: 2 Nos With Electro Mechanical Interlocking arrangment
Indication and digital metering
125TP plus N Aluminium sectionalised BUS suitable for 1.1 K V with a fault level with-stand: 20 KA for 1 second. The Earth Bus shall be of AL and run contInuously throughout the width of the panel.
Outgoing :63 A, 4Pole, 50 Hz, MCB : 3 Nos.
40 A, 4Pole, 50 Hz, MCB : 2 Nos.
20 A, DPPole, 50 Hz, MCB : 3 No.
Indication lamps (RYB) with control MCB - 03 Sets
Danger notice plate
Make : As listed in UHBVNL | 1 | Nos. | 54,000 ₹54,000 | 52,000 ₹52,000 Lowest | 53,818 ₹53,818 |
| 4.00 | Pathway Lighting Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.
Incomer :40A TPN MCCB - 1 NOS :
Outgoing : 16A TPN MCCB - 3 NOS :
Indication lamps (RYB) with control MCB - 03 Sets with Timer and Contactor
Danger notice plate
Make : As listed in UHBVNL | 2 | Nos. | 14,500 ₹29,000 | 14,000 ₹28,000 Lowest | 14,610 ₹29,220 |
| 5.00 | Main LT Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.
250A FP MCCB, 415 V, 50 Hz. : 2 Nos
250A 4P Contractor 415 V, 50Hz.: 2 Nos With Electro Mechanical Interlocking arrangment
Indication and digital metering
250TP plus N Aluminium sectionalised BUS suitable for 1.1 K V with a fault level with-stand: 20 KA for 1 second. The Earth Bus shall be of AL and run contInuously throughout the width of the panel.
Outgoing :63 A, 4Pole, 50 Hz, MCB : 4 Nos.
40 A, 4Pole, 50 Hz, MCB : 4 Nos.
20 A, DPPole, 50 Hz, MCB : 3 No.
Indication lamps (RYB) with control MCB - 03 Sets
Danger notice plate
Make : As listed in UHBVNL | 1 | Nos. | 24,400 ₹24,400 | 23,000 ₹23,000 Lowest | 24,467 ₹24,467 |
| 6.00 | Providing, Fabricating, Assembling, Painting, Hoisting and Erecting in position, including detailing of Primary Steel Structure M.S RHS/SHS/CHS/Plates of thicknesses as per static analysis conforming to IS 4923 / 1161/ 2062 Grade 250MPA in profile. Fabrication of structural elements shall be done using ARC/SAW/MAW/ welding process, including transportation, cutting, threading, machining, all leads and lifts up to all heights, tools and plants and necessary scaffolding etc. required for all operations.
The structural members shall be painted with first coat of Epoxy Primer DFT 30-micron, Final Coat Epoxy Paint 80 microns thick (to be applied in two coats) of which first coat shall be at ground and second coat after erection including touch- up of damaged area of already painted surfaces if any, up to all heights including Designing, Detailing, Providing, Fixing including Fabrication, Assembling and Erection of Roofing Material as per Non-Linear Analysis Maintaining a min Safety Coefficient of 4. Roofing Material Should be PES PVC Coated Fabric with both side PVDF lacquered/Coated, Weight 950 GSM, minimum Tensile Strength 5600/5400 N/5cm, minimum Tear Resistance 1000/900 N, minimum 10/15 years warranty FR Retardant B1.
This work shall include raw material, patterning, forming, cutting, Seaming (Welding), fixing and installation with GI cables thickness as per Analysis, flashing, SS Swage End Grade 304, Galvanized Membrane Plate with Paint as per Spec. etc. complete as per direction of the Engineer-in-Charge.
Clamping and Fixing Plate should be Galvanized
thickness as per design requirement. Seam Width should be Single Stroke and Minimum 50mm wide. Standard Warranty on Roofing Material should be minimum 10/15 Yrs. from Roofing Material Manufacturer/Supplier.
Note:
1. Mode of Measurement: Surface Area of Consumed
Tensile Fabric
Structure proposed by the contractor shall be vetted by
KSCL through NIT/IIT etc. and vendor shall have to work accordingly.
Fabric Make: Ferrari/ Mehler/ Verseidag/ Haytex/ Hiraoka/ Sieon/ Sattler
Fabric Colour: White or as approved by KSCL | 840 | Sqm | 7,000 ₹58,80,000 | 6,750 ₹56,70,000 Lowest | 7,009 ₹58,87,560 |
| 7.00 | SITC of 40W LED Batten having Extruded aluminium housing fitted with Engg. Plastic end caps. With Opal diffuser.LED should be populated on FR4 PCB in which LED’s should be mounted and connection should be in series parallel.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level))=110lumens/watt, Minimum system Lumens 4400 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI)=80, PF)=0.9,THD(10%, and Operating Temperature Range-10 deg C to plus 50deg C, IP20. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver.The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.BCLAB SP 44L LED CW PC SD or Equivalent. | 80 | Nos. | 1,000 ₹80,000 Lowest | 1,050 ₹84,000 | 1,061 ₹84,880 |
| 8.00 | Supply of 40W LED industrial Weatherproof Batten having Extruded aluminium housing fitted with end caps. Luminaire should be Completely prewired with accessories up to terminal block and fixture should have minimum efficacy at System level (Not Chip Level))=120lumens/watt, Minimum system Lumens 4800 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI)=80, PF)=0.9,THD(10%, and Operating Temperature Range-10 deg C to plus 50deg C, IP65,IK07. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver. The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.BIPC 40W XE TYPE or Equivalent. | 36 | Nos. | 2,500 ₹90,000 Lowest | 2,600 ₹93,600 | 2,726 ₹98,136 |
| 9.00 | Tennis court Lighting : Supply and Installation of 320W LED flood light Olymipc type luminaire, LED luminaire having Epoxy powder coated pressure die-cast aluminium housing,Weatherproof gaskets should be provided for LEDs and control gear compartments.Luinaire should be suitable for Side entry mounting for max. 38mm OD pipe bracket.The LED driver acces should be from top for easy maintenance.LEDs should be provided with non-yellowing modular secondary lens optics.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level))=120lumens/watt, Minimum system Lumens 38400 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 5665K ±355K, CRI)=70, PF)=0.9, THD(10%, and Operating Temperature Range-5 deg C to plus 45deg C, IP66. Built in Surge Protection of 4KV and external surge protection of 10kVand an operating Voltage Range of 140 to 270V AC,50Hz.Luminaire Weight should not exceed 1.5kg.The driver used is specially designed to have built-in surge voltage, open/short circuit protections.The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance.
LUMINAIRE MAKE : Phillips / Bajaj / Surya /VAK Lighting.
LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM. | 16 | Nos. | 21,500 ₹3,44,000 | 21,000 ₹3,36,000 Lowest | 21,534 ₹3,44,544 |
| 10.00 | Supply 7 installation of GEYSER 9L .Make Bajaj,havells,Crompton and grieavs,V-guard. | 18 | Each | 10,500 ₹1,89,000 Lowest | 10,500 ₹1,89,000 Lowest | 10,712 ₹1,92,816 |
Tender Value
₹3.6 Cr
EMD Value
₹7.2 L
Closing Date
19 Jan 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Om Prakash Kardam
Head Office
Balance work of Redevelopment of Sport Facilites at Karan Stadium Phase-1
2026_HRY_495384_1
2026F0B0F7A5 51C7 4185 842A C3B9AAD9CADB1767007
Open Tender
Civil Works
Works
120 days
Karnal
2 documents required · 2 mandatory
₹15,000
₹7.2 L
Yes
28 Sept 2026
7 Jan 2026
20 Jan 2026
7 Jan 2026
19 Jan 2026
7 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and Fixing TOILET CUBICLE - Toilet Cubicle Made Of Heat, Bacteria, Water Chemical, Scratch, Impact and Anti Bacterial Resistant 12Mm Thick ,Solid Compact Laminate Panels Included Doors, Pilasters and Intermediate Panels.Toilet cubicle I Shape (Front Partition) with standard ,dimension of Upto1950mm height x 1200mm width x 1500mm ,depth which includes 550-600mm door size width.Doors 1,Vertical Pilaster 2,U / Door Channels and Top Rail :- SS 304 Grade as per plan,Foot Assembly :- Shoe Box SS 316 Grade 16,Door lock with indicator SS 304 Grade 8,Door Knob SS 304 Grade 8,Self Closing Gravity Hinges SS 304 Grade 24,Coat Hook SS 304 Grade 8,Screws SS 304 Grade as per plan.all work done as per directed by engineer in charge. | 35 | Each | - | - |
| 2 | Main LT Panel: Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.
400A FP MCCB, 415 V, 50 Hz. : 2 Nos
400A 4P Contractor 415 V, 50Hz.: 2 Nos With Electro Mechanical Interlocking arrangment
Indication and digital metering
400TP plus N Aluminium sectionalised BUS suitable for 1.1 K V with a fault level with-stand: 20 KA for 1 second. The Earth Bus shall be of AL and run contInuously throughout the width of the panel.
Outgoing :
125A, 4Pole, 50 Hz, MCB : 1 Nos.
63 A, 4Pole, 50 Hz, MCB : 6 Nos.
40 A, 4Pole, 50 Hz, MCB : 4 Nos.
20 A, DPPole, 50 Hz, MCB : 3 No.
Indication lamps (RYB) with control MCB - 03 Sets
Danger notice plate Make : As listed in UHBVNL | 2 | Nos. | - | - |
| 3 | Main LT Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.
125A FP MCCB, 415 V, 50 Hz. : 2 Nos
125A 4P Contractor 415 V, 50Hz.: 2 Nos With Electro Mechanical Interlocking arrangment
Indication and digital metering
125TP plus N Aluminium sectionalised BUS suitable for 1.1 K V with a fault level with-stand: 20 KA for 1 second. The Earth Bus shall be of AL and run contInuously throughout the width of the panel.
Outgoing :63 A, 4Pole, 50 Hz, MCB : 3 Nos.
40 A, 4Pole, 50 Hz, MCB : 2 Nos.
20 A, DPPole, 50 Hz, MCB : 3 No.
Indication lamps (RYB) with control MCB - 03 Sets
Danger notice plate
Make : As listed in UHBVNL | 1 | Nos. | - | - |
| 4 | Pathway Lighting Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.
Incomer :40A TPN MCCB - 1 NOS :
Outgoing : 16A TPN MCCB - 3 NOS :
Indication lamps (RYB) with control MCB - 03 Sets with Timer and Contactor
Danger notice plate
Make : As listed in UHBVNL | 2 | Nos. | - | - |
| 5 | Main LT Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.
250A FP MCCB, 415 V, 50 Hz. : 2 Nos
250A 4P Contractor 415 V, 50Hz.: 2 Nos With Electro Mechanical Interlocking arrangment
Indication and digital metering
250TP plus N Aluminium sectionalised BUS suitable for 1.1 K V with a fault level with-stand: 20 KA for 1 second. The Earth Bus shall be of AL and run contInuously throughout the width of the panel.
Outgoing :63 A, 4Pole, 50 Hz, MCB : 4 Nos.
40 A, 4Pole, 50 Hz, MCB : 4 Nos.
20 A, DPPole, 50 Hz, MCB : 3 No.
Indication lamps (RYB) with control MCB - 03 Sets
Danger notice plate
Make : As listed in UHBVNL | 1 | Nos. | - | - |
| 6 | Providing, Fabricating, Assembling, Painting, Hoisting and Erecting in position, including detailing of Primary Steel Structure M.S RHS/SHS/CHS/Plates of thicknesses as per static analysis conforming to IS 4923 / 1161/ 2062 Grade 250MPA in profile. Fabrication of structural elements shall be done using ARC/SAW/MAW/ welding process, including transportation, cutting, threading, machining, all leads and lifts up to all heights, tools and plants and necessary scaffolding etc. required for all operations.
The structural members shall be painted with first coat of Epoxy Primer DFT 30-micron, Final Coat Epoxy Paint 80 microns thick (to be applied in two coats) of which first coat shall be at ground and second coat after erection including touch- up of damaged area of already painted surfaces if any, up to all heights including Designing, Detailing, Providing, Fixing including Fabrication, Assembling and Erection of Roofing Material as per Non-Linear Analysis Maintaining a min Safety Coefficient of 4. Roofing Material Should be PES PVC Coated Fabric with both side PVDF lacquered/Coated, Weight 950 GSM, minimum Tensile Strength 5600/5400 N/5cm, minimum Tear Resistance 1000/900 N, minimum 10/15 years warranty FR Retardant B1.
This work shall include raw material, patterning, forming, cutting, Seaming (Welding), fixing and installation with GI cables thickness as per Analysis, flashing, SS Swage End Grade 304, Galvanized Membrane Plate with Paint as per Spec. etc. complete as per direction of the Engineer-in-Charge.
Clamping and Fixing Plate should be Galvanized
thickness as per design requirement. Seam Width should be Single Stroke and Minimum 50mm wide. Standard Warranty on Roofing Material should be minimum 10/15 Yrs. from Roofing Material Manufacturer/Supplier.
Note:
1. Mode of Measurement: Surface Area of Consumed
Tensile Fabric
Structure proposed by the contractor shall be vetted by
KSCL through NIT/IIT etc. and vendor shall have to work accordingly.
Fabric Make: Ferrari/ Mehler/ Verseidag/ Haytex/ Hiraoka/ Sieon/ Sattler
Fabric Colour: White or as approved by KSCL | 840 | Sqm | - | - |
| 7 | SITC of 40W LED Batten having Extruded aluminium housing fitted with Engg. Plastic end caps. With Opal diffuser.LED should be populated on FR4 PCB in which LED’s should be mounted and connection should be in series parallel.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level))=110lumens/watt, Minimum system Lumens 4400 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI)=80, PF)=0.9,THD(10%, and Operating Temperature Range-10 deg C to plus 50deg C, IP20. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver.The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.BCLAB SP 44L LED CW PC SD or Equivalent. | 80 | Nos. | - | - |
| 8 | Supply of 40W LED industrial Weatherproof Batten having Extruded aluminium housing fitted with end caps. Luminaire should be Completely prewired with accessories up to terminal block and fixture should have minimum efficacy at System level (Not Chip Level))=120lumens/watt, Minimum system Lumens 4800 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI)=80, PF)=0.9,THD(10%, and Operating Temperature Range-10 deg C to plus 50deg C, IP65,IK07. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver. The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.BIPC 40W XE TYPE or Equivalent. | 36 | Nos. | - | - |
| 9 | Tennis court Lighting : Supply and Installation of 320W LED flood light Olymipc type luminaire, LED luminaire having Epoxy powder coated pressure die-cast aluminium housing,Weatherproof gaskets should be provided for LEDs and control gear compartments.Luinaire should be suitable for Side entry mounting for max. 38mm OD pipe bracket.The LED driver acces should be from top for easy maintenance.LEDs should be provided with non-yellowing modular secondary lens optics.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level))=120lumens/watt, Minimum system Lumens 38400 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 5665K ±355K, CRI)=70, PF)=0.9, THD(10%, and Operating Temperature Range-5 deg C to plus 45deg C, IP66. Built in Surge Protection of 4KV and external surge protection of 10kVand an operating Voltage Range of 140 to 270V AC,50Hz.Luminaire Weight should not exceed 1.5kg.The driver used is specially designed to have built-in surge voltage, open/short circuit protections.The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance.
LUMINAIRE MAKE : Phillips / Bajaj / Surya /VAK Lighting.
LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM. | 16 | Nos. | - | - |
| 10 | Supply 7 installation of GEYSER 9L .Make Bajaj,havells,Crompton and grieavs,V-guard. | 18 | Each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_573874.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .