| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | ₹23.5 L | L1 | Accepted-AOC Work awarded on the Basis of lowest rate quoted by the firm |
| 2 | L2₹24.7 L+₹1.2 L (5.13%)Rejected-AOC | ₹24.7 L+₹1.2 L (5.13%) | L2 | Rejected-AOC not in L1 |
| 3 | L3₹28.7 L+₹5.2 L (22.2%)Rejected-AOC | ₹28.7 L+₹5.2 L (22.2%) | L3 | Rejected-AOC not in L1 |
Tender Value
₹26.2 L
EMD Value
₹52,500
Closing Date
6 Nov 2023, 3:00 pmClosed
Director AMPRI,Bhopal
Near Habibganj Naka, Hoshangbad Road,Bhopal
Street light installation Work
2023_CSIR_171996_1
1(522)2023 Works
Open Tender
Electrical Works
Item Rate
60 days
CSIR-AMPRI
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Director AMPRI
₹52,500
Yes
29 Aug 2024
25 Oct 2023
7 Nov 2023
25 Oct 2023
6 Nov 2023
25 Oct 2023
Amount
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
a) 3.5 X 70 sq.mm ( 38 mm)
a) 3.5 X 300 sq.mm ( 70 mm)
Supplying and laying of following size of XLPE insulated and PVC sheathed aluminum conductor armoured power cable of 1.1 KV grade (ISI Mark ) confirming to IS: 7098 (Part-I) 1988 in the existing RCC / Hume / Metal / PVC pipe/ loose loop connection as reqd.
a) 2 x 10 Sq mm
b) 3.5 x 70 Sq mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying,Installation,testing & commissioning 65 and Above watt LED street light fitting road lighting luminaires with high power LED and unique peanutlens to ensure uniform distribution, higher spacing beteween poles and maintenance free system. With Driver & all accessories i/c connection complete etc. as reqd.( Phiplis/Wipro/crompton/havells)
Fabrication, supplying, installation, testing & commissioning of power coated MV cubical double door outdoor type control panel having hinged & lockable door completely dust & vermin proof of suitable size (but not less 0.5 sq. mtr. front area ) 30 cm deep ( nominal size) fabricated from 2mm MS sheet having suitable space for meter board i/c pdg. suitable CC foundation i/c having provision for mounting the following accessories in individual compartments i/c supplying and fixing the following with connections, interconnections, earthing painting etc. complete as required. a) Incomer: 1)63 Amps, 4 P 25 KA MCCB - 1 No. 2) 100 Amp 4 strip aluminium bus bar b) Outgoing :-1) 32 SPN MCB 230 Volt of 4 Nos.
Fabrication, supplying, installation, testing & commissioning of power coated MV cubical double door outdoor type control panel fedder piller with 400 Amps Bus bar for connecting 300 sq mm Cable having hinged & lockable door completely dust & vermin proof of suitable size (but not less 0.5 sq. mtr. front area ) 30 cm deep ( nominal size) fabricated from 2mm MS sheet having suitable space for meter board i/c pdg. suitable CC foundation i/c having provision for mounting the following accessories in individual compartments i/c supplying and fixing the following with connections, interconnections, earthing painting etc. complete as required.
Supplying, installation, testing and commissioning of hot dip Galvanized octagonal street light pole single section made of 3 mm thick sheet steel plate complete with foundation and grouting nut bolt etc. of following heights.(as per manufacture design). Pole should be finished with flush door for connection including 3x4.0 Sq. mm. PVC insulated FRLS copper conductor cable from flush door to fitting including supplying and fixing of suitable size of 'C' series SP MCB, 4 Pole heavy duty connector, mounted on hylem / mica sheet of thickness not less then 6 mm, connection etc. as required. Pole should be erected on suitable size cement concrete foundation with 1:2:4 (1 cement: 2 Coarse sand : 4 graded stone aggregate of 20mm dia nominal size) with steel reinforcement as per manufacturer recommendation /design and complete with suitable size of foundation bolts, templets , medium class GI PIPE of suitable dia. for cable entry etc.complete as required. (Note :- The name of the manufacture should be Embossed on the body of the pole near flush door)
a) 7 Metre height
Supply and fixing of following duly hot dip galvanised brackets for installation of light fittings on the existing poles –
a)Double Arm Bracket : :0.5 m long Double arm sword type decorative bracket made up of 70 mm dia C Class GI Pipe On the top of the pole as per manufacturer drawing and as approved by Engg-in-Charge.
b)Triple Arm Bracket : :0.5 m long trople arm sword type decorative bracket made up of 70 mm dia C Class GI Pipe On the top of the pole as per manufacturer drawing and as approved by Engg-in-Charge.
Supplying and drawing following size of FRLSPVC insulated Copper Conductor single core cable in existing surface/recess steel/PVC conduitas required
3x1.5 sq mm
Supplying ,installation ,testing and commissioning of Astronimical time switch for following configuration to be mounted in feeder pillers/light DBs for automatic switching On & OFF of street light at sun set and sun rise of Twilight (Auto,ON,Auto OFF,Audo modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c Programming at site complete as required
2 output per phase and suitable for sinle phase supply
3 output(1 output per phase) and suitable for Three phase supply
Dismeantling of pole/street light standard/strut embedded in cement concrete foundation etc with shifting of poles as per director of engineer in charge etc as reuired
SUMIT SWITCHGEARS AND ELECTRICALS
ANUKOM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .