Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
25 May 2021, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_124579_3
Fresh e-NIT No.EDJ/23 of 2021-22 Dated 18-05-2021
Open Tender
Electrical Works
Item Rate
PWD RandB Div Samba
please refer to NIT
3 documents required · 3 mandatory
₹0
Exempted
31 May 2021
18 May 2021
26 May 2021
19 May 2021
25 May 2021
19 May 2021
Amount
Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.
1 x 1.5 sq. mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
1 x 2.5 sq. mm
2 x 2.5 sq. mm
3 x 2.5 sq. mm
1 x 4 sq. mm
2 x 4 sq. mm
3 x 4 sq. mm
1 x 6 sq. mm
2 x 6 sq. mm
3 x 6 sq. mm
1 x 10 sq. mm
2 x 10 sq. mm
1 x 16 sq. mm
2 x 16 sq. mm
Supplying and fixing of Following light fitting along as read.
Supplying and fixing of 10 watt LED batten fitting 2 ft long including connections etc. as required.
Supplying and fixing of surface mounted 18/20 watt LED batten tube fiiting 4 feet long including connections etc as required.
Supplying & fixing Recess/surface mounted LED Luminarie with full diffuser (size 600mm x 600 mm).
Supplying and fixing of mirror light CFL fitting and necessary connection with 9/11W CFL lamp.
Surface/recessed square/round LED Panel 11/12 watt
Surface/recessed square/round LED Panel 8/9 watt
Supplying and fixing of BIS Approved ceiling fan of double ball bearing type, 1200mm sweep with 2.25 mfd condenser and down rod upto 1'-6" long on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire.
Supplying and fixing of following sizes exhaust fan complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.
225 mm sweep exhaust fan
300 mm sweep exhust fan
Supplying and fixing of fan hook (U hook) on ceiling with 4 Each of anchor fastener on both ends with necessary bolts and nuts and mansonry work as required.
Supplying and fixing of following sizes (oscillating type) wall mounting fan on wall with necessary connection.
400 mm Sweep Wall mounting fan
Supplying & fixing of 400 mm sweep pedestal mounting fan including transporting, assembling and putting into service.
Supplying and fixing 5 amps to 32 amps rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Single Pole and Neutral
Double Pole
Triple Pole
Triple Pole and Neutral
Supplying and fixing following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SPN 40 Amp.
SPN 63 Amp
TPN 40 Amp
TPN 63 Amp.
Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolater)
6 way (Double door )
8 way (Double door)
12 way (Double door )
16 way (Double door)
Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts,on surface/recess complete with tinned copper busbar, neutral bus bar, earth bar,din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolater)
4 Way (4+12), (Double door )
6 way ( 4+18), (Double door)
8 way (4+24), (Double door)
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make)
Supplying & fixing of folloiwing Electrical Accessories
PVC Batten (Casing Caping) 1"
PVC Batten (Casing Caping) 3/4"
Deep Box
Fan Box
5/6Amp. 3 pinTop
5/6Amp 2 pin Top
15/16 Amp 3pin Top
Insulation Tape (ISI brand)
Electronic Step Type fan Regulator switch type
Electronic Step Type fan Regulator socket type
Celing Rose
2.2/3/3.5 mfd fan condenser
Batten Holder/ Angel holder
Round sheets
PVC Bend 1"
PVC Bend 1.5"
Providing and fixing of following electrical accessories for replacement as and when required
1200mm x 36/40W fluorescent tube rod
Providing and fitting of LED Bulbs.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mm x 75mm)
3 Module (100mm x 75mm)
4 Module (125mm x 75mm)
6 Module (200mm x 75mm)
8 Module (125mm x125mm)
12 Module ( 200mm x 150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
12 Module
Supplying and fixing following piano type switch/ socket on the existing box/ cover inculding connection etc. as required.
5/6 amp switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Telephone socket outlet
TV Antenna socket outlet
Bell push
Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connections but excluding modular plate etc. as required.
5/6 amp switch
2 way 5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Telephone socket outlet
TV Antenna socket outlet
Bell push
Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supply and fixing of single phase of following rating self pumping priming for pumping water including connections etc as required.
Supplying and fixing of change over switch of following rating.
32 Amp. SP
63 Amp. SP
63 Amp. FP.
100 Amp. FP.
Supplying and replacement of the suitable size and rating of the following parts in the storage water heater and making the geyser in good working condition.
Heating Element
Thermostat with Control
Assembly
Repair of Tank including dismantling and re-installation of gyser.
Supplying, fixing & commissioning of Storage Water Heater (Geyser) of following capacity along with PVC Pipes/connections etc as required.
Overhauling the ceiling fan, supplying and replacing the same size and rating of bearing, condenser, cotter pins, shackle insulator, twin core copper wire and other defective material etc as required for making the fan in good working condition. The job includes dismantling of fan and re-installing the same as required.
Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. overhauling such as cleaning, replacement of same size and rating of bearing condenser, cotter pins, shackle insulator, twin core copper wire and other defective materials required for making the fan in good working condition. Job includes dismantling of fan and re-installing same as required
1200mm / 1400mm sweep ceiling fan
300mm sweep exchaust fan
Wall Fan
Rewinding of the following rating and phase motors for water lifting by using enameled copper wire of required gauage, varnishing oiling greasing etc. overhauling such as cleaning, replacement of same size and rating of bearing, copper wire and other defective materials required for making the moter in good working condition. The cost should inculde the rebate of old enameked copper and material. The workmanship shall be Grade A and up to the satisfaction of the Engineer in charge. Job includes dismantling of motor and re-installing same after repair as required.
3 phase (3HP) motor
1 phase (0.5 HP) motor
1 phase (1 HP) motor
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board inculding drilling holes in cubicle panel, making connection etc. as required.
100 A, 30kA, FPMCCB
200 A, 36kA, FPMCCB
Supply of Distilled water required for the Battries.
Supplying & fixing of following Remote Bells
Bell controlled by Single Remote
Call bell / Ding Dong, Single phase
Supplying & fixing of following PVC Gang Box.
One way (space for 1 No. 5/6 amp switch)
Two way (space for 2 Each 5/6 amp switches)
Three way (space for 3 Each 5/6 amp switches)
Four way (space for 4 Each 5/6 amp switches)
1 + 1 way (space for 1 No. 5/6 Amp Switch + 1 No. 5/6 Amp Socket)
2 + 1 way (space for 2 Each 5/6 Amp Switches + 1 No. 5/6 Amp Socket)
3 + 1 way (space for 3 Each 5/6 Amp Switches + 1 No. 5/6 Amp Socket)
4 + 1 way (space for4 Each 5/6 Amp Switches + 1 No. 5/6 Amp Socket)
2 + 2 way (space for 2 Each 5/6 Amp Switches + 2 No. 5/6 Amp Sockets)
3 + 2 way (space for 3 Each 5/6 Amp Switches + 2 No. 5/6 Amp Sockets)
3+ 3 way (space for 3 Each 5/6 Amp Switches + 3 No. 5/6 Amp Sockets)
1 + 1 way (Space for 1 No. 15/16 Amp switch + 1 No. 15/16 Amp Socket)
Supplying laying, Testing and commissioning of following sizes PVC Aluminium Cable including connections etc as required.
6 Sq.mm Twin Core
10 Sq.mm Twin Core
16 Sq.mm Twin Core
25 Sq.mm Twin Core
35 Sq.mm Twin Core
Supplying, installation, testing and commissioning of following type of 150 AH tubular batteries for inverters etc as required. Note.:- (Rs.1800/Battery has to be deducted for the scrap of old batteries from allotted rate in case of replacement of battery with out of warranty period.
With warranty of 36 months full replacement.
Supplying, installation, testing and commissioning of following type of inverters as required.
Repairing of following type of inverter by replacing PCB.
850 VA to 1050 VA
above 1050 VA to 2000 VA
Repairing of following type of inverter by reparing PCB.
850VA to 1050 VA
above 1050 VA to 2000 VA
Charging of Single Battery including carriage from site of work to shop and again from shop to site of work after charging.
Charging of Double Batteries including carriage from site of work to shop and again from shop to site of work after charging.
Supply and fixing of following LED type Street lights including connections etc as required.
Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required.
(RO +UV) with TDS controller
Servicing of following type of water purifiers as required.
(RO + UV) by way of replacing of candles and mambrane etc. as required
Supplying of Hologen Heater (With 3 Rods)
Supplying of Pillar heater (Gopi)
Supplying of Single Rod Room heater
Supplying of Double Rod Room heater
Supplying of Blower/Heat Convector (Usha)
Repairing of Hologen Heater by replacing its rods.
Labour charges required for rectification of fault in panel boards, all kinds of light fittings, fans, equipment and all electrical accessories etc and making them in good working condition or as required
Electrician
Asstt. Electrician/ Helper
Supplying and fixing Desert Cooler Metal Body with built in Stand. (Heavy Gauge ISI Mark)
Supplying and fixing Plastic Body Cooler (Symphony/Bajaj) 50 Ltr
Supplying and fixing of Angle Iron Stand for Cooler with roller
Supply of electric Kettle of following capacity.
Repair of electric Kettle of following capacity.
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly and having ROHS certification. The earthing pit should be covered with PVC cover. Providing and laying of 25 x 5 mm copper strip from copper rod upto the main panel
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode shall be tested from CPRI. The earthing pit should be covered with PVC cover. Providing and laying of 25 x 5 mm G.I strip from G.I rod upto the main panel
Supplying, installation ,testing and commissioning floor/wall mounted Busbar chamber of following capacity Bus Bar Chamber made up of 1.6 mm thick IP42 sheet steel enclosure duly painted with powder coating complete with following accessories.4NO Aluminium bus bars having current rating of 800 Amp suitable for 415V,3phase,4wire,50HZ A.C.SUPPLY = 1 set
Supplying & fixing of following items for use in Networking system as required
Network switch 24 Port
Network switch 16 Port
Network switch 8 Port
4 U rack
6 U rack
9 U rack
HDMI Cable 3 Mtrs
HDMI Cable 10 Mtrs
HDMI Cable 20 Mtrs
Supply, installation, testing & commissioning of 1.1 KV PVC insulated and PVC sheathed XLPE Power Cable of following size etc. along with providing & fixing of Aluminium thimbles, U Clamps, Insulators etc as required including carriage upto site of work.
50 Sq.mm 3.5 Core Armored
70 Sq.mm 3.5 Core Armored
95 Sq.mm 3.5 Core Armored
120 Sq.mm 3.5 Core Armored
150 Sq.mm 3.5 Core Armored
185 Sq.mm 3.5 Core Armored
240 Sq.mm 3.5 Core Armored
300 Sq.mm 3.5 Core Armored
400 Sq.mm 3.5 Core Armored
Supplying & fixing of L.T termination Kit suitable size for the following.
400 sq. mm 3.5 core Aluminium LT cable
150 sq. mm 3.5 core Aluminium LT cable
Supply, installation, testing & commissioning of Following LED TV's.
32 " Full HD
43 " Full HD Smart
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Repair of Automatic Voltage Stabilizer by way of copper winding etc as required.
Above 3KVA to 5 KVA
Repair of automatic voltage stabilizer by way of replacement of damaged relays/circuits etc as required.
Upto 6 KVA
Servicing of Split/ Window AC
Supply, erection, testing and commissioning of compressor suitable for 2 Ton/1.5 Ton Split type /Window type A.C's with Gas charging and other required accessories to get A.C workable.
Providing and fixing of copper pipe of required size for all type of Split/Window AC's
Dismantling of 1.5 Ton /2 Ton window A.C
Dismantling of 1.5 Ton /2 Ton split A.C
Installation of 1.5 Ton /2 Ton window A.C
Installation of 1.5 Ton /2 Ton split A.C
Replacement of defective motor with new one for 1.5 Ton/2 Ton Split / Window AC
Replacement of defective capacitor with new one for 1.5 Ton/2 Ton Split / Window AC
Providing & fixing of Blades for 1.5 Ton/2 Ton Split / Window AC
Providing & fixing of Blower drum for 1.5 Ton/2 Ton Split AC
Providing & fixing of Blower drum for 1.5 Ton/2 Ton Window AC
Provision of Gas charging of water cooler of all sizes.
Supplying and fixing of wall/floor mounted iron stand for outer unit of Split AC.
Supplying & installation of Automatic Voltage stabilizer.
4 KVA for 1.5 Ton split / window AC's /Water Cooler copper wound floor/Wall mounted
5 KVA for 2.0 Ton split / window AC's copper wound floor/ Wall mounted
Repair of PCB of 1.5 Ton/2.0 Ton Split AC/Window AC
Replacement of PCB with New One of 1.5 Ton/2.0 Ton Split AC/Window AC
Gas charging of 2.0 Ton /1.5 Ton split type /window type A.C alongwith detecting the cause of leakage of gas and repairing the same as required
Supplying, installation, testing & complition of following type/capacity of AC's With Warranty as i). One Year for Complete AC. ii). 5 Year's for compressor replacement.
1.5 Ton Split AC (3 Star) Copper.
1.5 Ton Window AC (3 Star) Copper
Servicing of D.G sets of
D.C office
Conference hall
Minor repair to the servo voltage stabilizer installed at DC office and Divisional office and complex
Repair to the D.G set by way of replacement of exhaust pipe, silencer etc.
Des Raj Dabgotra
SH ASHWANI KUMAR
M/S YASIR IMRAN CONTRACTOR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .