Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC 2 89 BIJOYGARH JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L1 | Accepted-AOC AOC ISSUED | |
| 2 | L2₹12.4 L+₹1.3 L (11.2%)Rejected-Finance | L2 | Rejected-Finance that the bid
is not L1 | |
| 3 | L3₹12.5 L+₹1.3 L (12.0%)Rejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L3 | Rejected-Finance that the bid
is not L1 | |
| 4 | L4₹12.9 L+₹1.8 L (15.8%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L4 | Rejected-Finance that the bid
is not L1 |
| Sl No | Description | Qty | Unit | ALPHA ELECTRICALS L4 | A.K.ENTERPRISE L1 | Sanjay Shaw L2 | M/S R. K. ENTERPRISE L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | EI work:--
Dismantling the existing E.I. work by Co's own tools & tackles and take unnecessary items away from site by maintening normalcy as far as possible as per direction of EIC . | 2 | item | 500 ₹1,000 Lowest | 1,859 ₹3,718 | 2,000 ₹4,000 | 5,000 ₹10,000 |
| 2.00 | A. Distribution wiring:---
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make: Polycab / Havells/Glostar/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 12 mtr. | 8 | pt | 1,492 ₹11,936 | 1,200 ₹9,600 | 1,391 ₹11,128 | 900 ₹7,200 Lowest |
| 3.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make: Polycab / Havells/Glostar/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Anchor Roma/ Legrand/ Schneider) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 12 mtr ( Faculty Room) | 15 | pt | 1,580 ₹23,700 | 1,300 ₹19,500 | 1,472 ₹22,080 | 900 ₹13,500 Lowest |
| 4.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make: Polycab / Havells/Glostar/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with
1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Anchor Roma/ Legrand/ Schneider) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 11 mtr (Inside ART & Seminar room) | 70 | pt | 1,455 ₹1,01,850 | 1,000 ₹70,000 | 1,357 ₹94,990 | 800 ₹56,000 Lowest |
| 5.00 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Polycab / Havells/Glostar/KEI) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Anchor Roma/ Legrand/ Schneider) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. i) On Board | 15 | pt | 240 ₹3,600 | 230 ₹3,450 | 249 ₹3,735 | 90 ₹1,350 Lowest |
| 6.00 | Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
19 mm dia 3 mm thick polythene pipe without earth continuity wire. [3(a)/E-2] | 400 | Mtr | 75 ₹30,000 | 75 ₹30,000 | 85 ₹34,000 | 70 ₹28,000 Lowest |
| 7.00 | Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
25 mm dia 3 mm thick polythene pipe without earth continuity wire | 120 | Mtr | 85 ₹10,200 | 100 ₹12,000 | 111 ₹13,320 | 75 ₹9,000 Lowest |
| 8.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Polycab / Havells/Glostar/KEI) of the following sizes in the prelaid polythene pipe as per GS.
a) 3 x (1.5 sqmm) [1(b) / E- 9] | 50 | Mtr | 60 ₹3,000 | 44 ₹2,200 Lowest | 48 ₹2,400 | 90 ₹4,500 |
| 8.10 | b) 2x(2.5 sqmm)+1x(1.5 sqmm) For computer board & power plag [1(s) / E-9] | 210 | Mtr | 75 ₹15,750 | 60 ₹12,600 Lowest | 65 ₹13,650 | 90 ₹18,900 |
| 8.20 | c) 2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ] | 20 | Mtr | 115 ₹2,300 | 88 ₹1,760 Lowest | 100 ₹2,000 | 98 ₹1,960 |
Tender Value
₹14.0 L
EMD Value
₹27,940
Closing Date
11 Mar 2026, 1:00 pmClosed
EE-II KNHED PWDte.
OFFICE OF THE EXECUTIVE ENGINEER Kolkata North Health Electrical Division, P.W.Dte. KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata700073
Renovation work and Modification of the ART Centre Under Kolkata Medical College and Hospital---(Part A). Electrical Installation Work
2026_WBPWD_1011102_1
WBPWD/EE-II/KNHED/NIQ-86/ 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
Kolkata
Please refer Tender documents.
6 documents required · 6 mandatory
₹27,940
OFFICE OF THE EE KNHED PWDte.
2 Jul 2026
19 Feb 2026
13 Mar 2026
19 Feb 2026
11 Mar 2026
26 Feb 2026
25 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | EI work:--
Dismantling the existing E.I. work by Co's own tools & tackles and take unnecessary items away from site by maintening normalcy as far as possible as per direction of EIC . | 2 | item | - | - |
| 2 | A. Distribution wiring:---
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make: Polycab / Havells/Glostar/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 12 mtr. | 8 | pt | - | - |
| 3 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make: Polycab / Havells/Glostar/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Anchor Roma/ Legrand/ Schneider) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 12 mtr ( Faculty Room) | 15 | pt | - | - |
| 4 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make: Polycab / Havells/Glostar/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with
1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Anchor Roma/ Legrand/ Schneider) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 11 mtr (Inside ART & Seminar room) | 70 | pt | - | - |
| 5 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Polycab / Havells/Glostar/KEI) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Anchor Roma/ Legrand/ Schneider) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. i) On Board | 15 | pt | - | - |
| 6 | Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
19 mm dia 3 mm thick polythene pipe without earth continuity wire. [3(a)/E-2] | 400 | Mtr | - | - |
| 7 | Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
25 mm dia 3 mm thick polythene pipe without earth continuity wire | 120 | Mtr | - | - |
| 8 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Polycab / Havells/Glostar/KEI) of the following sizes in the prelaid polythene pipe as per GS.
a) 3 x (1.5 sqmm) [1(b) / E- 9] | 50 | Mtr | - | - |
| 8.1 | b) 2x(2.5 sqmm)+1x(1.5 sqmm) For computer board & power plag [1(s) / E-9] | 210 | Mtr | - | - |
| 8.2 | c) 2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ] | 20 | Mtr | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
suspension.pdf
Additional Documents • 2.91 MB
BOQ_2482770.xls
BOQ • 0.40 MB
2911_Form.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .