Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-Finance Lowest | |
| 2 | L2₹7.4 L+₹45,641 (6.56%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 |
Tender Value
₹7.9 L
EMD Value
₹15,800
Closing Date
22 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Nagtalao
Military Engineer Services AGE I Nagtalao Pin 900120 CO 56 APO
Periodical maintenance to various capacities of capacitor banks and other misc works at Nagtalao under AGE I Nagtalao
2020_MES_349934_1
8128/20-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Nagtalao
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I Nagtalao
₹15,800
Yes
27 Jun 2020
4 Jun 2020
24 Jun 2020
4 Jun 2020
22 Jun 2020
10 Jun 2020
60 days
Amount
Excavation in trenches not exceeding 1.5mtrs wide and not exceeding 1.5 mtr deep in soft /loose soil for laying underground cables complete all as specified and directed
Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25 Cm
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point
M&L for sand cushioning to PVC/ XLPE cables with tibba sand and punning to provide required cover to UG cables. Note :- For the purpose of payment only punned thickness will be measured
Laying only old retrieved stone putty/brick/PCC cover on the cable abutting each other for the cable protection gap between two adjacent patties n.exc 10mm
Material and labour for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for UG cable protection
Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor of size 16 sqmm to 70 sqmm from trenches/duct/pipes, on walls, poles of following unserviceable cable from site to store
M& L for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core
M& L for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 core
M& L for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core
Supply and fix MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA.
Supply and fix MCCB 3 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA.
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 50 KVAR capacity
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 25 KVAR capacity
Supply and fix in repairs 4 pole power contactor MNX-11 of with 2 NO & 2 NC auxilairy contact of 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge.Make: L&T or equivalent in Legrand/Siemens.
S&F Digital Ammeter square dial three phase Class1. all as directed and approved by eng-in-charge.
S/F new push button switch to the existing capacitor pannel all as specified and directed by eng-in-charge.
Supply and fix new indicating lamp neon type complete with contct block & holder assembly all as specified and directed by eng-in-charge
m&L for internal wiring of existing capacitor pannel with 16 Sqmm single core copper wire with color coding all as specified and directed by eng-in-charge.
Dwarka Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .